• 제목/요약/키워드: Surface marker method

검색결과 80건 처리시간 0.027초

Simulation of Viscous Flow around the Moving Underwater Vehicle

  • Kwag, Seung-Hyun
    • 한국해양공학회:학술대회논문집
    • /
    • 한국해양공학회 2001년도 추계학술대회 논문집
    • /
    • pp.202-206
    • /
    • 2001
  • A three dimensional incompressible Navier-Stokes code based on the third derivative upwind is employed to simulate the flow around the underwater vehicle advancing on the calm water. Computations are carried out in the range of Froude numbers 0.4 to 0.7. The wave resistance, lift, moment and the pressure distribution on the body are calculated. Computations are performed in a rectangular grid system based on the Marker & Cell method. For validation, computation results are compared with existing experimental results.

  • PDF

천해수역에 위치한 3차원 해저돌출물 주위 점성유동장의 수치시뮬레이션 (A Numerical Simulation of a Viscous Flow behind a Sea-botton Isolated Ridge in Shallow Water)

  • 이영길;;이무근
    • 한국해양공학회지
    • /
    • 제6권1호
    • /
    • pp.29-42
    • /
    • 1992
  • 자유표면하에 잠긴 복잡한 3차원 물체 주위의 흐름을 해소하기 위한 수치계산법이 TUMMAC(Tokyo Univ. Modified Marker And Cell)법을 기초로 하여 개발되었다. 임의물체의 no-slip 3차원 물체표면조건을 보다 간단히 처리하기 위하여 "porosity"라는 개념이 도입되었으며, 담수성에 잠겨 있는 해저돌출물 주위의 유동을 계산하여 그 응용성을 검토하였다. 돌출물 후방의 복잡한 와동들의 상호간섭이 잘 시뮬레이션 되었다.시뮬레이션 되었다.

  • PDF

Determination of Tyrosinase mRNA in Melanoma by Reverse Transcription-PCR and Optical Mirror Resonance Biosensor

  • Taeboo Choe;Park, Inchul;Seokil Hong
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • 제7권4호
    • /
    • pp.212-215
    • /
    • 2002
  • Tyrosinase transcript In the blood Is known as the marker of malignant melanoma and it has been often determined by using reverse transcription-polymerase chain reaction (RT-PCA) . However, after the PCR process, the quantification of amplified CDMA by the gel electrophoresis is not reliable and time-consuming. for this reason, we tried to quantify the PCR product using a cuvette-type biosensor, where the oligonucleotide probe was immobilized on the cuvette surface and the single strand CDMA, the denatured PCH product, was then hybridized onto the immobilized probe to give a response signal. The response was Immediate and takes 15 min to obtain a stable signal. The biosensor was much more sensitive comparing to the gel electrophoresis method. The quantification of PCR product using a cuvette-type biosensor was feasible and rapid.

HMD 환경에서 사용자 손의 자세 추정을 위한 MLP 기반 마커 분류 (Marker Classification by Sensor Fusion for Hand Pose Tracking in HMD Environments using MLP)

  • 록콩부;최은석;유범재
    • 한국정보처리학회:학술대회논문집
    • /
    • 한국정보처리학회 2018년도 추계학술발표대회
    • /
    • pp.920-922
    • /
    • 2018
  • This paper describes a method to classify simple circular artificial markers on surfaces of a box on the back of hand to detect the pose of user's hand for VR/AR applications by using a Leap Motion camera and two IMU sensors. One IMU sensor is located in the box and the other IMU sensor is fixed with the camera. Multi-layer Perceptron (MLP) algorithm is adopted to classify artificial markers on each surface tracked by the camera using IMU sensor data. It is experimented successfully in real-time, 70Hz, under PC environments.

In Situ Single Cell Monitoring by Isocyanide-Functionalized Ag and Au Nanoprobe-Based Raman Spectroscopy

  • Lee, So-Yeong;Jang, Soo-Hwa;Cho, Myung-Haing;Kim, Young-Min;Cho, Keun-Chang;Ryu, Pan Dong;Gong, Myoung-Seon;Joo, Sang-Woo
    • Journal of Microbiology and Biotechnology
    • /
    • 제19권9호
    • /
    • pp.904-910
    • /
    • 2009
  • The development of effective cellular imaging requires a specific labeling method for targeting, tracking, and monitoring cellular/molecular events in the living organism. For this purpose, we studied the cellular uptake of isocyanide-functionalized silver and gold nanoparticles by surface-enhanced Raman scattering (SERS). Inside a single mammalian cell, we could monitor the intracellular behavior of such nanoparticles by measuring the SERS spectra. The NC stretching band appeared clearly at ${\sim}2,100cm^{-1}$ in the well-isolated spectral region from many organic constituents between 300 and 1,700 or 2,800 and $3,600cm^{-1}$. The SERS marker band at ${\sim}2,100cm^{-1}$ could be used to judge the location of the isocyanide-functionalized nanoparticles inside the cell without much spectral interference from other cellular constituents. Our results demonstrate that isocyanide-modified silver or gold nanoparticle-based SERS may have high potential for monitoring and imaging the biological processes at the single cell level.

Reliability of Quantifying Maximal Mouth Opening and Lateral Mandibular Shift in Individuals With and Without Temporomandibular Disorder Using Three-dimensional Ultrasound-based Motion Analysis

  • Oh, Jae-seop;Kim, Si-hyun;Kyung, Moon-su;Park, Kyue-nam
    • 한국전문물리치료학회지
    • /
    • 제26권3호
    • /
    • pp.99-105
    • /
    • 2019
  • Background: Although magnetic resonance imaging is accurate, it is expensive to measure the movement of temporomandibular joint. The three-dimensional (3D) motion analysis system is an inexpensive measurement tool. Objects: This study examined the reliability of quantifying the mouth opening and lateral mandibular shift and differences between individuals with and without temporomandibular disorder (TMD) using the hygienic method of surface markers on the skin with 3D ultrasound-based motion analysis. Methods: This study included 24 subjects (12 with and 12 without TMD). Temporomandibular joint motion during mouth opening was recorded using two surface markers with 3D ultrasound-based motion analysis. An intraclass correlation coefficient [ICC (3,k)] was used to confirm the intrarater reliability of quantifying kinematic temporomandibular joint motion, and an independent t-test was used to evaluate differences in maximal mouth opening and lateral mandibular shift between the two groups. Results: Assessment of mouth opening and lateral mandibular shift showed excellent test-retest reliability with low standard error of measurement. The lateral mandibular shift and opening-lateral mandibular shift ratio were significantly increased in the TMD group during maximum mouth opening (p<.05). However, no significant difference in maximal mouth opening was observed between the groups with and without TMD (p>.05). Conclusion: This hygienic and simple surface marker method can be used to quantify the mouth opening and lateral mandibular shift at the end-range of mouth opening. The TMD group showed an increased lateral mandibular shift movement at the end-range of mouth opening. The lateral mandibular shift movement can be regarded as a symptom in the diagnosis and treatment of TMD.

Liposome-Based Assay for Phospholipase C

  • 임수정;고유찬;이은옥;김종국
    • Bulletin of the Korean Chemical Society
    • /
    • 제18권7호
    • /
    • pp.761-766
    • /
    • 1997
  • Phospholipase C from Clostridium perfringens is known to catalyze the hydrolysis of phospholipids in biological membranes. In this study, a simple and sensitive method for assaying phospholipase C was developed by using liposomes entrapping calcein as a fluorescent marker. Phospholipase C-induced lysis of liposomes was determined by measuring the fluorescence intensity of calcein released out from liposomes, Various liposomes with different compositions were prepared by reverse-phase evaporation method to investigate the effect of liposomal composition on the lytic activity of phospholipase C. The calcein-entrapping efficiency of liposomes was affected by the chain length of fatty acid in phosphatidylcholine constituting liposomes. The lytic activity of phospholipase C was the highest against liposomes prepared with eggPC. The lytic activity decreased with increasing chain length of fatty acid in phosphatidylcholine. Incorporation of cholesterol more than 20% into the liposomal bilayer inhibited the phospholipase C-induced lysis. The lysis of liposomes was more greatly increased by the addition of 10 mM of calcium. The lytic activity of phospholipase C was also affected by the surface charge of liposomes. Taken together, it was concluded that reverse-phase evaporation vesicles composed of dipalmitoylphosphatidylcholine and cholesterol in the molar ratio of 9 : 1 allowed to detect the lowest concentration of phospholipase C (0.10 μg/assay volume). This study suggested that the use of liposomes can provide a simple, sensitive and inexpensive method for assaying phospholipase C.

선체주위 기포거동에 관한 기초적 연구 (A Basic Research of Air Bubble Locus around the Ship Hull)

  • 김호은;이영길
    • 대한조선학회논문집
    • /
    • 제37권4호
    • /
    • pp.48-55
    • /
    • 2000
  • 선박의 저항을 줄이기 위하여 발생시킨 기포의 거동을 알기 위해, 선체주위의 기포거동에 과한 기초적 연구를 수행하였다. 본 연구에서는 선체주위에 발생된 기포의 거동에 대하여, 기포의 크기와 발생위치를 변화시켜가며 수치계산 및 실험을 수행하여, 선체주위의 기포거동에 관한 특성을 연구하고자 하였다. 기포의 거동방정식은 기포의 부력을 고려한 Kawakita의 것을 사용하였다. 수치계산은 MAC(Marker And Cell)법을 기초로 한 유한차분법(Finite Difference Method)을 사용하였으며, 실험은 Series 60선형에 대하여 회류수조에서 수행되었다. 실험과 계산은 서로 비교하여 보았다.

  • PDF

Comparison of Serum Fucose Levels in Leukoplakia and Oral Cancer Patients

  • Rai, Narendra Prakash;Anekar, Jayaprasad;Shivaraja, Shankara YM;Divakar, Darshan Devang;Al Kheraif, Abdulaziz Abdullah;Ramakrishnaiah, Ravikumar;Sebastian, Roopa;Raj, AC;Al-Hazmi, Ali;Mustafa, habil Mohamed
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제16권17호
    • /
    • pp.7497-7500
    • /
    • 2015
  • Background: Tumor markers, designated as a broad group of substances produced by malignancies, could be in the form of biochemical substances, immunological substances, cell surface changes and genetic alterations. Cancer, a disorder of cellular behavior is characterized by alteration of serum glycoproteins. L-fucose, a hexose, which is the terminal sugar in most of the plasma glycoproteins, may be useful as a tumor marker for the detection, monitoring and prognostic assessment of malignancies. The aim of the study was to ascertain the role of serum fucose as a biomarker for early detection of oral cancer and to compare serum fucose levels in healthy controls, leukoplakia and oral cancer patients. Materials and Methods: The study included 60 (100.0%) subjects, who were grouped as 20 (33.3%) control subjects, 20 (33.3%) squamous cell carcinoma patients and 20 (33.3%) leukoplakia patients. Fucose estimation was done using UV-visible spectrophotometry based on the method as adopted by Winzler using cysteine reagent. The results were analyzed statistically using ANOVA with Bonferroni post hoc tests. Results: Results showed a high significance in serum fucose in oral squamous cell carcinoma (OSCC) and leukoplakia subjects compared to normal controls. There was a gradual increase in the values noted from control to leukoplakia and to squamous cell carcinoma. Conclusions: Estimation of serum fucose may be a reliable marker and can be used as an effective diagnostic biomarker in oral squamous cell carcinoma patients.

현미경, Flow Cytometer, HPLC 색소자료 및 원격탐사를 이용한 이어도 관측기지 주변수의 식물플랑크톤 연구 (Phytoplankton in the Waters of the Ieodo Ocean Research Station Determined by Microscopy, Flow Cytometry, HPLC Pigment Data and Remote Sensing)

  • 노재훈;유신재;이정아;김현철;이재학
    • Ocean and Polar Research
    • /
    • 제27권4호
    • /
    • pp.397-417
    • /
    • 2005
  • Phytoplankton community structure and distribution pattern in the surface water around the Ieodo Ocean Research Station were investigated during seven cruises carried out from July, 2003 to October, 2004. Samples were analyzed using various tools including a microscope, flow cytometer, and HPLC. Satellite images were used to analyze spatio-temporal phytoplankton biomass distribution. SeaWiFS chlorophyll a (chl a) images showed that spring blooms occurred in April-May near the Ieodo Station, and these waters were under the influence of Changjiang Dilute Water during July-October. Also, during the July-October period, HPLC pigments data showed increasing zeaxanthin concentrations, a marker pigment of cyanobacteria whereas increasing concentrations of various other pigments such as fucoxanthin, peridinin, prasinoxanthia alloxanthin, 19'-hexanoyloxyfucoxanthin and chlorophyll b were noted during spring blooms. Such pigment marker data were consistent with picoplankton data analyzed by flow cytometer and nano-microplankton analyzed by microscope. The pigment-CHEMTAX method was used to drive the phytoplankton group apportioned chi a. Diatoms, chlorophytes, dinoflagellates, and cryptophytes comprised 25.8, 20.7, 15.9, and 14.1%, respectively, of the total chl a in May. Average cyanobacteria concentrations in July-October contributed 25.4% of the total concentration. This was the highest percent contribution and was followed by chlorophytes, diatoms, and prymnesiophytes. This study discusses results from various methods, similarities and differences in the results among those methods, and the application range of the results from different analytical methods. Also, the study reveals a detailed phytolpankton community structure in the waters around the Ieodo Station, and suggests future monitoring considerations in relation to cell morphology, ecology and diversity factors according to taxonomic groups.