Advantage of Distally Based Superficial Sural Artery Flap in the Soft Tissue Defect of the Lower Leg, Ankle, Foot (하퇴부와 족관절 및 족부의 피부 결손에 대한 역행성 표재 비복동맥 피판을 이용한 재건의 장점)

  • Ha, Dae-Ho;Kim, Sang-Soo;Chun, Churl-Hong;Kim, Dong-Churl;Choi, Yu-Sun;Kim, Kyeong-Jin
    • Archives of Reconstructive Microsurgery
    • /
    • v.10 no.2
    • /
    • pp.118-123
    • /
    • 2001
  • Introduction : We report advantages of distally based superficial sural artery flap in the soft tissue defect in lower leg, ankle and foot. They are easier and less complicated technique than others. Material & Method : Total 26 patients were operated and their soft tissue defect site were 10 cases of anterior tibial surface, 6 cases of Achilles tendon area, 3 cases of lateral and medial surface of tibia, 3 cases of foot dorsum surface, 3 cases of sole, 1 case of medial aspect of ankle. Average pedicle distance was 12.8 cm(range $8{\sim}21cm$) and follow up period was mean 18 months. Result : We obtained 24 cases of excellent and good results. The two cases were reported low complication rate, which were one case of skin necrosis covered full thickness skin graft, and the other case of infection. Conclusion : The advantage of distally based superficial sural artery flap in soft tissue defect are long distant pedicle, short operation time, easy elevation of pedicle, constant and reliable blood supply and good cosmetic result with thin-thickness flap.

  • PDF

Study on Surface-defect Passivation of InP System Quantum Dots by Photochemical Method (광화학적 방법을 통한 InP계 양자점 표면결함 부동태화 연구)

  • Kim, Doyeon;Park, Hyun-Su;Cho, Hye Mi;Kim, Bum-Sung;Kim, Woo-Byoung
    • Journal of Powder Materials
    • /
    • v.24 no.6
    • /
    • pp.489-493
    • /
    • 2017
  • In this study, the surface passivation process for InP-based quantum dots (QDs) is investigated. Surface coating is performed with poly(methylmethacrylate) (PMMA) and thioglycolic acid. The quantum yield (QY) of a PMMA-coated sample slightly increases by approximately 1.3% relative to that of the as-synthesized InP/ZnS QDs. The QYs of the uncoated and PMMA-coated samples drastically decrease after 16 days because of the high defect state density of the InP-based QDs. PMMA does not have a significant effect on the defect passivation. Thioglycolic acid is investigated in this study for the effective surface passivation of InP-based QDs. Surface passivation with thioglycolic acid is more effective than that with the PMMA coating, and the QY increases from 1.7% to 11.3%. ZnS formed on the surface of the InP QDs and S in thioglycolic acid show strong bonding property. Additionally, the QY is further increased up to 21.0% by the photochemical reaction. Electron-hole pairs are formed by light irradiation and lead to strong bonding between the inorganic and thioglycolic acid sulfur. The surface of the InP core QDs, which does not emit light, is passivated by the irradiated light and emits green light after the photochemical reaction.

Defect Assessment for Integrity Evaluation of CANDU Pressure Tubes (CANDU 압력관 건전성평가를 위한 결함해석)

  • 김영진;석창성;박윤원
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.3
    • /
    • pp.731-740
    • /
    • 1995
  • The objective of this paper is to develop defect assessment technology for integrity evaluation of CANDU pressure tubes. In fracture mechanics analysis, three-dimensional and two-dimensional (line-spring model) finite element analyses were performed to obtain the stress intensity factor for axial and circumferential surface cracks. In leak before break (LBB) analysis, heat transfer analyses for through-wall cracks were performed by considering the cooling effect and the LBB application time was computed. It was shown that the analytical results obtained in this study provide less-conservative but accurate solution for defect assessment of CANDU pressure tubes.

A study on the reduction of blow hole defects in aluminum sand casting (알루미늄 사형주조에서 기공 결함 감소를 위한 연구)

  • Lee, Dong-Youn;Lee, Chun-Kyu
    • Design & Manufacturing
    • /
    • v.14 no.4
    • /
    • pp.52-57
    • /
    • 2020
  • In this study attempted to prevent defects due to blow holes among defects of sand casting products. It was intended to reduce the defect rate by reducing the blow hole of the inner surface. Currently, expectations and requirements for the quality level of non-ferrous aluminum casting in the casting industry are increasing. In addition, the shape is complex and the shrinkage precision is required. Among them, the test prototype is expensive to manufacture the mold, and the production time is also long, and the product is manufactured by sand casting. At this time, the highest defect rates are defects caused by shrinkage defects, surface defects, and blow holes.. At this study, the manufacturing time was shortened by using the shape of the fluid movement path in advance. Also, it is possible to reduce defects due to blow holes.

Evaluation of Defect Types for Characteristic Database Construction of Large Sewage Box Culverts (대형 하수박스암거의 속성 데이터베이스 구축을 위한 결함유형 평가)

  • Han, Sangjong;Song, Homyeon
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.31 no.6
    • /
    • pp.619-628
    • /
    • 2017
  • As the 3D laser scanning technology capable of databaseing large sewage box culverts becomes possible, it is necessary to develop a standardization manual that can clearly distinguish the structural and operational defect types of box culver and analyze the defect data. In this study, we collected and analyzed defects in sewage box culverts of 14,827m in total by selecting three districts in Korea. The major defects were surface damages, and their defect densities were $2.17m^2/m$, $0.27m^2/m$ and $0.10m^2/m$ for aggregate exposure, Steel reinforcement exposure, and Steel reinforcement projecting. In order to support the decision of the box culverment management, it was divided into five grades and each defect code and defect score were allocated. The results of this study are useful for the diagnosis of the sewage box culverts in Korea and it is expected to support a decision making for management.

Reconstruction for the Soft Tissue Defect of Heel using Free Lateral Arm Neurosensory Flap (유리 외측 상박 감각신경 피판술을 이용한 종부 연부조직 결손의 재건)

  • Kim, Dong-Churl;Kim, Sang-Soo;Ha, Dae-Ho;Yoo, Hee-Jun;Lee, Dong-Hoon
    • Archives of Reconstructive Microsurgery
    • /
    • v.8 no.1
    • /
    • pp.15-21
    • /
    • 1999
  • Soft tissue defect on heel area of the foot present difficult problems particularly because of anatomic property of plantar surface of the foot. There is a paucity of available local tissue in the foot for coverage. In addition to having little expandable tissue, the foot's plantar surface has a unique structure, making its replacement especially challenging. Plantar skin is attached to the underlying bone by fibrous septa, preventing shear of the soft-tissue surfaces from the underlying skeleton. Plantar surface of foot is in constant contact with the environment. Protective sensibility also would be maintained or restored in the ideal reconstruction. So the ideal flap for reconstruction of the heel should include thin, durable hairless skin with potential for reinnervation. The aim of this article is to present a clinical experience of free lateral arm neurosensory flap for reconstruction of the heel. From March 1995 to December 1997, a total 16 lateral arm free flaps were performed to soft tissue defects on the weight-bearing area of the hindfoot. we used tibial nerve as recepient nerve in 11 and calcaneal branch of tibial nerve in 5 for restoration of sensibility of flap. All cases survived completely. A static two-point discrimination of 14 to 34mm was detected in the flap. Radial nerve palsy which was caused by hematoma in donor site occured in one case, but recorverd in 3 weeks later completely. In conclusion, the lateral arm free flaps are versatile, reliable and sensible cutaneous flap and especially indicated for soft tissue defect on plantar surface of the hindfoot which are not good indications for other better-known flaps.

  • PDF

Comparison of Resorbable and Nonresorbable Membrane for Guided Bone Regeneration in Implant Dehiscence Defects (매식체 주위 열개형 골 결손부의 골 재생시 흡수성 막과 비흡수성 막의 비교)

  • Kwon, Tae-Hoon;Chung, Chin-Hyung;Yim, Sung-Bin
    • Journal of Periodontal and Implant Science
    • /
    • v.30 no.2
    • /
    • pp.323-335
    • /
    • 2000
  • The purpose of this study was to examine the frequency of dehiscence bone defect on peri-implant and to compare the difference between resorbable membrane and nonresorbable membrane in bone regeneration on peri-implant. Amomg the patients, 22 patientswho have recieved an implant surgery at the department of Periodontics in Dankook University Dental Hospital showed implant exposure due to the dehiscence defect and 27 implants of these 22 patients were the target of the treatment. $Gore-Tex^{(R)}$ and $Bio-mesh^{(R)}$ were applied to the patients and treated them with antibiotics for five days both preoperatively and postoperatively. Reentry period was 26 weeks on average in maxilla and 14 weeks on average in mandible. The results were as follows : 1. Dehiscence bone defect frequently appeared in premolar in mandible and anterior teeth in maxilla respectively. 2. Among 27 cases, 2 membrane exposures were observed and in these two cases, regenerated area was decreased. 3. In non-resorbable membrane, bone surface area $9.25{\pm}4.84$ preoperatively and significantly increased to $11.48{\pm}7.52$ postoperatively.(P<0.05) 4. In resorbable membrane, bone surface area was $14.80{\pm}8.25$ preoperatively and meaningfully widened to $17.61{\pm}10.67$ postoperatively.(P<0.05) 5 . The increase of bone surface area in non-resorbable membrane was $2.23{\pm}3.38$ and the increase of bone surface area in resorbable membrane was $2.80{\pm}3.00$ ;therefore, there was no significant difference between these two membranes(P<0.05). This study implies that the surgical method using DFDB and membrane on peri-implant bone defect is effective in bone regeneration regardless the kind of the membrane, and a similar result was shown when a resorbable membrane was used.

  • PDF

On the Surface Defect Analysis of an Aluminum Tube for an OPC Drum using n SEM and EDX (SEM/EDX를 이용한 OPC 드럼용 Al 튜브의 표면결함 분석에 관한 연구)

  • Kim, Chung-Kyun
    • Tribology and Lubricants
    • /
    • v.23 no.4
    • /
    • pp.143-148
    • /
    • 2007
  • The surface defects of an aluminum tube for an OPC drum have been analyzed using a scanning microscopy(SEM) and an energy dispersive X-ray analyze.(EDX). The SEM/EDX system, which may provide good information on the surface defects and their distributions, provides an optical diameter of an impurity and a chemical composition. These are strongly related on the coated film thickness and quality of an OPC drum, which is a key element of a toner cartridge for a laser printer. The experimental results show that the local deformations, scratch wear, and flaws are produce the non-uniform coating layers, which may be removed by a manufacturing process of an aluminum tube. The major parameters on the coating quality of an OPC drum are the impurities of an aluminum tube such as silicon, oxygen, calcium, carbon, sulphur, chlorine, and others. These impurities may be removed by an ingot molding, extrusion and drawing, quality control, and packing processes with a strict manufacturing technology.

SEM/EDX Analysis on the Composition and Surface Defect in a Pin Bushing Bearing for an Automotive Engine (자동차 엔진용 핀부싱 베어링의 SEM/EDX 이용 성분.결함분석에 관한 연구)

  • Kim, Chung-Kyun
    • Tribology and Lubricants
    • /
    • v.23 no.5
    • /
    • pp.195-200
    • /
    • 2007
  • This paper presents the friction induced scuffing and wear defects analysis of a pin bushing bearing based on the chemical composition using a scanning microscopy (SEM) and an energy dispersive X-ray analyzer (EDX). The SEM/EDX system, which may provide good information on the surface thermal defects and chemical compositions, provides impurities such as an aluminum, a silicon, a ferrous component and an oxygen, especially. The EDX measured results show that the oxygen may reduce the strength and a hardness of a pin busing, which may lead to a scuffing and a seizure on the rubbing contact surface. The current technology fabricated by a sintering for a pin bushing bearing should be modified or changed to reduce the oxygen composition and the impurities in pin bushing materials.