• Title/Summary/Keyword: Support Device

Search Result 1,021, Processing Time 0.021 seconds

Adjacent Terminal Device Detection Technique for User Mobility Support on Home Entertainment System (홈 엔터테인먼트 시스템에서 사용자 이동성 지원을 위한 인접 터미널 장치 탐색 기법)

  • Kim, Sang-Wook;Jung, E-Gun
    • Journal of Korea Multimedia Society
    • /
    • v.12 no.1
    • /
    • pp.156-167
    • /
    • 2009
  • Computing environment is evolving rapidly to ubiquitous environment. It thus makes people access and utilize any resource on the move and makes location of objects rise to the rank of the most important information. However provision of location information is too restrictive in small environments such as a home or building. In this paper we propose a home entertainment system which supports user mobility based on sensor networks and distributed devices. The proposed system estimates a user location by using signal strength received from Bluetooth ad-hoc networks. This estimated location information can tell which device a user can take advantage of while moving. In order to prove possibility of user mobility support, the system is implemented on our UPnP A/V framework home entertainment system to provide content streaming and the result shows that a provision of service for mobile users could be possible in small ubiquitous computing environments.

  • PDF

A Study on the Heating of Lipiodol during Lymphangiography (림프관 조영술 시 리피오돌의 가온에 관한 고찰)

  • Kang, Rae-Wook;Kim, Jae-Seok
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.5
    • /
    • pp.597-602
    • /
    • 2020
  • The study was conducted to improve the efficiency of the test and to reduce the exposure dose of patients and operators by analyzing the difference in the moving speed of Lipiodol according to the temperature during lymphography. The device for injecting Lipiodol at a constant pressure was self-made, and after inserting Lipiodol into the Connecting Tube, the moving speed of the contrast agent was photographed at temperatures of 26℃, 36℃, and 46℃ using a heat transfer device. Lipiodol movement time from the Support Catheter to 20cm was measured and analyzed, and statistical significance was confirmed. In the 46℃ environment, the average moving time was 11 seconds, at 36℃ the average was 13 seconds, and at 26℃ the average was 17 seconds. Lipiodol showed a significant difference in moving time with increasing temperature (p<.001), and it was confirmed that the higher the temperature, the faster the moving speed. In the case of lymphangiography, when heated to a certain temperature (46 degrees) rather than injecting Lipiodol at room temperature, the injection speed can be increased and the speed of movement in the lymphatic vessel can be improved.

The Protocol on WS-ECA Framework (WS-ECA 프레임워크 프로토콜)

  • Lee, Won-Suk;Park, Jong-Hun;Lee, Kyu-Chul
    • Journal of Internet Computing and Services
    • /
    • v.8 no.6
    • /
    • pp.55-73
    • /
    • 2007
  • Importance of coordination among heterogeneous devices is significantly increasing to meet the challenges presented by the evolvement of the ubiquitous computing environment. The web services technology is going up as a promising solution to support the inter-operability between such heterogeneous devices via well-defined protocol. Currently, ECA(Event-Condition-Action) rule based framework for coordinating devices is proposed, it is called as WS-ECA(Web Services-ECA) framework. This framework was basically based on the web services and proposed the ECA based rule language, And this also proposed the framework that could enable the device coordination based on proposed rule language. In this paper, we propose the protocol among the components of WS-ECA framework to support dynamic feature for ubiquitous environment, and we also propose WSDL extension to support service and event descriptions these are provided in components of this framework.

  • PDF

DisplayPort 1.1a Standard Based Multiple Video Streaming Controller Design (디스플레이포트1.1a 표준 기반 멀티플 비디오 스트리밍 컨트롤러 설계)

  • Jang, Ji-Hoon;Im, Sang-Soon;Song, Byung-Cheol;Kang, Jin-Ku
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.48 no.11
    • /
    • pp.27-33
    • /
    • 2011
  • Recently many display devices support the digital display interface as display market growth. DisplayPort is a next generation display interface at the PC, projector and high definition content applications in more widely used connection solution development. This paper implements multiple streams based on the behavior of the main link that is suitable for the display port v1.1a standard. The limit point of Displayport, interface between the Sink Device and Sink Device is also implemented. And two or more differential image data are enable to output the result through four Lanes stated in display port v1.1a, of two or more display devices without the addition of a separate Lane. The Multiple Video Streaming Controller is implemented with 6,222 ALUTs and 6,686 register, 999,424 of block memory bits synthesized using Quartus II at Altera Audio/Video Development board (Stratix II GX FPGA Chip).

Development of Self-propelled Explosive Subsoiler (2) - Construction of Prototype and Performance Evaluation - (자주식 심토환경 개선기 개발(2) - 본체 제작 및 성능 평가 -)

  • Lee, Dong-Hoon;Park, Woo-Pung;Kim, Sang-Cheol;Lee, Kyou-Seung
    • Journal of Biosystems Engineering
    • /
    • v.34 no.6
    • /
    • pp.404-410
    • /
    • 2009
  • This study was carried out to develop a self-propelled type explosive subsoiler for improving the root zone soil conditions in orchard and other forest fields. Prototype was designed to be able to inject air and other soil improving material such as lime into soil at the same time, and thus improve the air permeability and drainage of orchard soils to promote the root growth of tree for high quality fruit production. Soil penetration device of explosive subsoiler is composed of air hammer, penetration rob and air injection nozzle. To support the soil penetration device of explosive subsoiler to penetrate vertically, modified Scott-Russel mechanism was used. Timing control device for simultaneous injection of soil improving material with air was attached to the out side wall of air cylinder and as the cylinder move, the soil improving material was injected into soil at the same time. Turning radius of prototype was 2.2-2.3 m with good mobility in sloped land. It took approximately 1 minute for lime injection system to reach the optimum pressure of 9.9 kg/$cm^2$, average 10-20 seconds were required to rupture soil with the depth of 50 cm and 2-3 seconds were required for explosion, so all in all about 1 minute and 20 seconds were required for one cycle of explosion. Maximum soil rupture depth and diameter were 50 cm and 3-4 m respectively depending on the soil type and soil moisture content. For final design of explosive subsoiler inclination angle of lime hopper was increased from 60 degree to 70 degree and the shape of hopper was changed from rectangular cone to circular cone to solve the clogging problem of lime at out let. Agitating system operated by compressed air was attached to the metering device of the prototype, thus more than 90 cc of lime was discharged per cycle from metering device without clogging problems.

A Novel Kinematic Design of a Knee Orthosis to Allow Independent Actuations During Swing and Stance Phases (회전기 및 착지기 분리 구동을 가능케 하는 새로운 무릎 보장구의 기구부 설계)

  • Pyo, Sang-Hun;Kim, Gab-Soon;Yoon, Jung-Won
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.17 no.8
    • /
    • pp.814-823
    • /
    • 2011
  • Nowadays many neurological diseases such as stroke and Parkinson diseases are continually increasing. Orthotic devices as well as exoskeletons have been widely developed for supporting movement assistance and therapy of patients. Robotic knee orthosis can compensate stiff-knee gait of the paralyzed limb and can provide patients consistent assistance at wearable environments. With keeping a robotic orthosis wearable, however, it is not easy to develop a compact and safe actuator with fast rotation and high torque for consistent supports of patients during walking. In this paper, we propose a novel kinematic model for a robotic knee orthosis to drive a knee joint with independent actuation during swing and stance phases, which can allow an actuator with fast rotation to control swing motions and an actuator with high torque to control stance motions, respectively. The suggested kinematic model is composed of a hamstring device with a slide-crank mechanism, a quadriceps device with five-bar/six-bar links, and a patella device for knee covering. The quadriceps device operates in five-bar links with 2-dof motions during swing phase and is changed to six-bar links during stance phase by the contact motion to the patella device. The hamstring device operates in a slider-crank mechanism for entire gait cycle. The kinematics and velocity/force relations are analyzed for the quadriceps and hamstring devices. Finally, the adequate actuators for the suggested kinematic model are designed based on normal gait requirements. The suggested kinematic model will allow a robotic knee orthosis to use compact and light actuators with full support during walking.

Analysis on sEMG Signals of Contents Using Finger Tapping Device (Finger Tapping 기기를 활용한 콘텐츠의 sEMG 신호 분석)

  • Han, Sang-bae;Byeon, Sang-kyu;Kim, Jae-hoon;Shin, Sung-Wook;Chung, Sung-taek
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.19 no.6
    • /
    • pp.153-160
    • /
    • 2019
  • In this paper, we would like to support anyone who can rehabilitate conveniently and happily by implementing rehabilitation device and game contents that can improve the motor ability of fingers. So we developed a Finger Tapping Device that can measure finger-regulation ability, accuracy, and agility and implemented tracking, visual response, finger-regulation on game contents by utilizing this device. The verification of usability was confirmed by analyzing sEMG signals during the execution of three types of game contents after attaching sEMG to the flexor digitorum poundus, which is most involved in finger movement. As a result of the experiment, activation of the flexor digitorum poundus was performed during execution of every game contents. Furthermore, we confirmed that there is a difference in agility by measuring the reaction time for each finger according to the visual response.

IRRADIATION DEVICE FOR IRRADIATION TESTING OF COATED PARTICLE FUEL AT HANARO

  • Kim, Bong Goo;Park, Sung Jae;Hong, Sung Taek;Lee, Byung Chul;Jeong, Kyung-Chai;Kim, Yeon-Ku;Kim, Woong Ki;Lee, Young Woo;Cho, Moon Sung;Kim, Yong Wan
    • Nuclear Engineering and Technology
    • /
    • v.45 no.7
    • /
    • pp.941-950
    • /
    • 2013
  • The Korean Nuclear-Hydrogen Technology Development (NHTD) Plan will be performing irradiation testing of coated particle fuel at HANARO to support the development of VHTR in Korea. This testing will be carried out to demonstrate and qualify TRISO-coated particle fuel for use in VHTR. The testing will be irradiated in an inert gas atmosphere without on-line temperature monitoring and control combined with on-line fission product monitoring of the sweep gas. The irradiation device contains two test rods, one has nine fuel compacts and the other five compacts and eight graphite specimens. Each compact contains about 260 TRISO-coated particles. The irradiation device is being loaded and irradiated into the OR5 hole of the in HANARO core from August 2013. The device will be operated for about 150 effective full-power days at a peak temperature of about $1030^{\circ}C$ in BOC (Beginning of Cycle) during irradiation testing. After a peak burn-up of about 4 atomic percentage and a peak fast neutron fluence of about $1.7{\times}10^{21}\;n/cm^2$, PIE (Post-Irradiation Examination) of the irradiated coated particle fuel will be performed at IMEF (Irradiated Material Examination Facility). This paper reviews the design of test rod and irradiation device for coated particle fuel, and discusses the technical results for irradiation testing at HANARO.

The test methods of Lifting performance and Environmental resistance tests using power assist device for a fireman to rescue humans (인명구조용 소방대원 근력지원장치의 양중성능 및 내환경 시험 방법)

  • Lee, Minsu;Park, Chan;Lee, Seonmin;Lee, Dongeun
    • Journal of the Society of Disaster Information
    • /
    • v.13 no.3
    • /
    • pp.358-365
    • /
    • 2017
  • As the damage caused by disasters increases rapidly around the world, it is necessary to develop the technology for equipment to reduce human injury. Therefore in the support of fire safety and 119 rescue and rescue technology research and development project, in the "Development of a power assist device for a fireman to rescue humans(2015 ~ 2018)" for life saving restoration, we are developing equipment that satisfies the lifting performance considering the disaster environment and the disaster response scenario(Amount of load over 100 kg, height of over 1 m, height over middle 60 cm, speed over 0.2 m/s). In this study, we propose a lifting performance and environmental test method to evaluate the usefulness of the power-assisted device and analyze and verify detailed specifications of the device through dynamics analysis of the lifting performance test. This study suggests that the proposed test method can be applied practically to evaluate whether a stable performance of a power-assisted device is achieved.

Effects of High Frequency Warm Needling of LI4 Acupoint on the Carrageenan-induced Arthritis in Rats (합곡(合谷)(LI4)의 고주파 온침 자극이 흰쥐의 족과(足踝) 관절염(關節炎)에 미치는 효과)

  • Park, Sang-Yeon;Kwon, Oh-Sang;Choi, Won-Jong;Kim, Jae-Hyo;Kim, Kyung-Sik;Sohn, In-Chul;Ahn, Seong-Hun
    • Korean Journal of Acupuncture
    • /
    • v.26 no.2
    • /
    • pp.61-74
    • /
    • 2009
  • Objectives: The warm needling technique is a method which combines the effects of acupuncture with those of moxibustion. The purpose of this study was to find the stimulus effects of a high frequency warm needling device when stimulating acupoint $LI_4$ on the carrageenan-induced arthritis. Methods: This study was to observe the effects to edema reaction, WBF(weight bearing force), NO concentration, nNOS expression after the electro high frequency stimulus of high frequency warm needling device on LI4 with insulated acupuncture needle. Results: The effect of the high frequency warm needling device is to rise up the temperature in proportion to the current intensity. After stimulating on the acupoint $LI_4$ of the carrageenan-induced arthritis in rats with the high frequency warm needling device, it significantly reduced edema in the rat's foot. In addition, WBF, NO concentration of spinal cord (nmol/mg), and nNOS relative expression were reduced. Conclusions: The above results support the idea that stimulus by the high frequency warm needling device on $LI_4$ produces a potent analgesic effect in the arthritis pain model of the rat. Moreover, stimulus by the high frequency warm needling device modulates endogenous NO through the suppression of nNOS protein expression.

  • PDF