• 제목/요약/키워드: Superimposition range

검색결과 11건 처리시간 0.028초

안면 입체영상 중첩시 중첩 기준 범위 설정에 따른 적합도 차이 (VALIDITY OF SUPERIMPOSITION RANGE AT 3-DIMENSIONAL FACIAL IMAGES)

  • 최학희;조진형;박홍주;오희균;최진휴;황현식;이기헌
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제31권2호
    • /
    • pp.149-157
    • /
    • 2009
  • Purpose: This study was to evaluate the validity of superimposition range at facial images constructed with 3-dimensional (3D) surface laser scanning system. Materials and methods: For the present study, thirty adults, who had no severe skeletal discrepancy, were selected and scanned twice by a 3D laser scanner (VIVID 910, Minolta, Tokyo, Japan) with 12 markers placed on the face. Then, two 3D facial images (T1-baseline, T2-30 minutes later) were reconstructed respectably and superimposed in several manners with $RapidForm^{TM}2006$ (Inus, Seoul, Korea) software program. The distances between markers at the same place of face were measured in superimposed 3D facial images and measurement were done all the 12 makers respectably. Results: The average linear distances between the markers at the same place in the superimposed image constructed by upper 2/3 of the face was $0.92{\pm}0.23\;mm$, in the superimposed image constructed by upper 1/2 of the face was $0.98{\pm}0.26\;mm$, in the superimposed image constructed by upper 1/3 of the face and nose area was $0.99{\pm}0.24\;mm$, in the superimposed image constructed by upper 1/3 of the face was $1.41{\pm}0.48\;mm$, and in the superimposed image constructed by whole face was $0.83{\pm}0.13\;mm$. There were no statistically significant differences in the liner distances of the makers placed on the area included in superimposition range used for partial registration methods but there were significant differences in the linear distances of the markers placed on the areas not included in superimposition range between whole registration method and partial registration methods used in this study. Conclusion: The results of the present study suggest that the validity of superimposition is decreased as superimposition range is reduced in the superimposition of 3D images constructed with 3D laser scanner for the same subject.

Evaluation of the marginal and internal gaps of three different dental prostheses: comparison of the silicone replica technique and three-dimensional superimposition analysis

  • Park, Jin-Young;Bae, So-Yeon;Lee, Jae-Jun;Kim, Ji-Hwan;Kim, Hae-Young;Kim, Woong-Chul
    • The Journal of Advanced Prosthodontics
    • /
    • 제9권3호
    • /
    • pp.159-169
    • /
    • 2017
  • PURPOSE. The purposes of this study were to evaluate the marginal and internal gaps, and the potential clinical applications of three different methods of dental prostheses fabrication, and to compare the prostheses prepared using the silicone replica technique (SRT) and those prepared using the three-dimensional superimposition analysis (3DSA). MATERIALS AND METHODS. Five Pekkton, lithium disilicate, and zirconia crowns were each manufactured and tested using both the SRT and the two-dimensional section of the 3DSA. The data were analyzed with the nonparametric version of a two-way analysis of variance using rank-transformed values and the Tukey's post-hoc test (${\alpha}=.05$). RESULTS. Significant differences were observed between the fabrication methods in the marginal gap (P < .010), deep chamfer (P < .001), axial wall (P < .001), and occlusal area (P < .001). A significant difference in the occlusal area was found between the two measurement methods (P < .030), whereas no significant differences were found in the marginal gap (P > .350), deep chamfer (P > .719), and axial wall (P > .150). As the 3DSA method is three-dimensional, it allows for the measurement of arbitrary points. CONCLUSION. All of the three fabrication methods are valid for measuring clinical objectives because they produced prostheses within the clinically acceptable range. Furthermore, a three-dimensional superimposition analysis verification method such as the silicone replica technique is also applicable in clinical settings.

Three-dimensional evaluation of the transfer accuracy of a bracket jig fabricated using computer-aided design and manufacturing to the anterior dentition: An in vitro study

  • Park, Jae-Hyun;Choi, Jin-Young;Kim, Seong-Hun;Kim, Su-Jung;Lee, Kee-Joon;Nelson, Gerald
    • 대한치과교정학회지
    • /
    • 제51권6호
    • /
    • pp.375-386
    • /
    • 2021
  • Objective: To evaluate the accuracy of a one-piece bracket jig system fabricated using computer-aided design and manufacturing (CAD/CAM) by employing three-dimensional (3D) digital superimposition. Methods: This in vitro study included 226 anterior teeth selected from 20 patients undergoing orthodontic treatment. Bracket position errors from each of the 40 arches were analyzed quantitatively via 3D digital superimposition (best-fit algorithm) of the virtual bracket and actual bracket after indirect bonding, after accounting for possible variables that may affect accuracy, such as crowding and presence of the resin base. Results: The device could transfer the bracket accurately to the desired position of the patient's dentition within a clinically acceptable range of ± 0.05 mm and 2.0° for linear and angular measurements, respectively. The average linear measurements ranged from 0.029 to 0.101 mm. Among the angular measurements, rotation values showed the least deviation and ranged from 0.396° to 0.623°. Directional bias was pronounced in the vertical direction, and many brackets were bonded toward the occlusal surface. However, no statistical difference was found for the three angular measurement values (torque, angulation, and rotation) in any of the groups classified according to crowding. When the teeth were moderately crowded, the mesio-distal, bucco-lingual, and rotation measurement values were affected by the presence of the resin base. Conclusions: The characteristics of the CAD/CAM one-piece jig system were demonstrated according to the influencing factors, and the transfer accuracy was verified to be within a clinically acceptable level for the indirect bracket bonding of anterior teeth.

Temperature-Dependent Thermal and Chemical Stabilities as well as Mechanical Properties of Electrodeposited Nanocrystalline Ni

  • Zheng, Liangfu;Peng, Xiao
    • Metals and materials international
    • /
    • 제24권6호
    • /
    • pp.1293-1302
    • /
    • 2018
  • Nanocrystalline (NC) Ni electrodeposits (EDs) with a mean grain size of $34{\pm}12nm$ has been investigated, from room temperature to $800^{\circ}C$ under a purge gas of argon, by both non-isothermal and isothermal differential scanning calorimetry measurements, in combination with characterization of temperature-dependent microstructural evolution. A significant exothermic peak resulting from superimposition of recrystallization and surface oxidation occurs between 340 and $745^{\circ}C$ at a heating rate of $10^{\circ}C/min$ for the NC Ni EDs. The temperatures for recrystallization and oxidation increase with increasing the heating rate. In addition, recrystallization leads to a profound brittle-ductile transition of the Ni EDs in a narrow range around the peak temperature for the recrystallization.

치과용 모형 스캐너의 지대치 중첩 과정이 최종 가상 모형에 미치는 영향 (Effect of abutment superimposition process of dental model scanner on final virtual model)

  • 유범영;손큰바다;이규복
    • 대한치과보철학회지
    • /
    • 제57권3호
    • /
    • pp.203-210
    • /
    • 2019
  • 목적: 본 연구는 치과용 모형 스캐너를 이용하여 단일 전장관과 3본 고정성의치 모형을 스캔하는 과정에서 지대치의 중첩 과정이 최종 가상 모형에 미치는 영향을 알아보려 하였다. 재료 및 방법: 평가를 위해 단일 전장관과 3본 고정성의치를 위한 석고 모형을 제작하였다. 그리고 Pindex system을 이용하여 핀 작업된 모형을 제작하였다. 기준 스캔 데이터(CAD Reference Model)와 실험 스캔 데이터(CAD Test Model)를 획득하기 위해서 치과용 모형 스캐너(E1, 3Shape A/S, Copenhagen, Denmark)를 이용했다. 기준 스캔 데이터는 지대치를 분할한 후 탈착하지 않고 스캔하였다. 그리고 실험 스캔 데이터는 분할된 지대치를 분리하여 스캔 후, 기준 스캔 데이터에 중첩되었다(n = 20). 마지막으로 3차원 검사 소프트웨어(release 2018.0.0; Geomagic control X; 3D Systems)를 이용하여 root mean square (RMS)를 분석하였고, 통계 분석은 Mann-Whitney U test를 사용하였다 (${\alpha}=.05$). 결과: 단일 전장관 지대치의 RMS 평균은 $10.93{\mu}m$, 3본 고정성의치 지대치의 RMS 평균은 $6.9{\mu}m$가 나왔다. 두 그룹의 RMS 평균값은 통계적으로 유의한 차이를 보여줬다 (P < .001). 또한 두 그룹의 양(positive)과 음(negative)의 오류는 단일 전장관 지대치는 $9.83{\mu}m$, $-6.79{\mu}m$, 3본 고정성의치 지대치는 $6.22{\mu}m$, $-3.3{\mu}m$의 평균값이 나왔다. 두 그룹의 양과 음의 오류 평균값은 통계적으로 모두 3본 고정성의치 지대치가 단일 전장관 지대치보다 통계적으로 유의하게 낮은 값을 보여주었다 (P < .001). 결론: 핀 작업된 모형의 스캔 과정에서 지대치의 개수가 증가하여도 지대치의 중첩에 의한 오류는 증가하지 않았다. 또한 단일 전장관 지대치에서 유의하게 높은 오류를 보였지만 임상적으로 허용 가능한 스캔 정확도의 범위에 있다.

적층가공 방식으로 제작한 전치와 구치 임시보철물의 적합도 비교 (Comparative evaluation of the fitness of anterior and posterior interim crowns fabricated by additive manufacturing)

  • 박영대;강월
    • 대한치과기공학회지
    • /
    • 제43권4호
    • /
    • pp.153-159
    • /
    • 2021
  • Purpose: The purpose of this study was to assess the fitness of anterior and posterior interim crowns fabricated by three different additive manufacturing technologies. Methods: The working model was digitized, and single crowns (maxillary right central incisor and maxillary right first molar) were designed using computer-aided design software (DentalCad 2.2; exocad). On each abutment, interim crowns (n=60) were fabricated using three types of additive manufacturing technologies. Then, the abutment appearance and internal scan data of the interim crown was obtained using an intraoral scanner. The fitness of the interim crowns were evaluated by using the superimposition of the three-dimensional scan data (Geomagic Control X; 3D Systems). The one-way analysis of variance and Tukey posterior test were used to compare the results among groups (α=0.05). Results: A significant difference was found in the fitness of the interim crowns according to the type of additive manufacturing technology (p<0.05). The posterior interim crown showed smaller root mean square value than the anterior interim crown. Conclusion: Since the fitness of the posterior interim crown produced by three types of additive manufacturing technology were all within clinically acceptable range (<120 ㎛), it can be sufficiently used for the fabrication of interim crowns.

Optimization of forensic identification through 3-dimensional imaging analysis of labial tooth surface using open-source software

  • Arofi Kurniawan;Aspalilah Alias;Mohd Yusmiaidil Putera Mohd Yusof;Anand Marya
    • Imaging Science in Dentistry
    • /
    • 제54권1호
    • /
    • pp.63-69
    • /
    • 2024
  • Purpose: The objective of this study was to determine the minimum number of teeth in the anterior dental arch that would yield accurate results for individual identification in forensic contexts. Materials and Methods: The study involved the analysis of 28 sets of 3-dimensional (3D) point cloud data, focused on the labial surface of the anterior teeth. These datasets were superimposed within each group in both genuine and imposter pairs. Group A incorporated data from the right to the left central incisor, group B from the right to the left lateral incisor, and group C from the right to the left canine. A comprehensive analysis was conducted, including the evaluation of root mean square error (RMSE) values and the distances resulting from the superimposition of dental arch segments. All analyses were conducted using CloudCompare version 2.12.4 (Telecom ParisTech and R&D, Kyiv, Ukraine). Results: The distances between genuine pairs in groups A, B, and C displayed an average range of 0.153 to 0.184mm. In contrast, distances for imposter pairs ranged from 0.338 to 0.522 mm. RMSE values for genuine pairs showed an average range of 0.166 to 0.177, whereas those for imposter pairs ranged from 0.424 to 0.638. A statistically significant difference was observed between the distances of genuine and imposter pairs(P<0.05). Conclusion: The exceptional performance observed for the labial surfaces of anterior teeth underscores their potential as a dependable criterion for accurate 3D dental identification. This was achieved by assessing a minimum of 4 teeth.

리튬 디실리케이트 최종 결정화 과정이 CAD/CAM으로 제조된 수복물의 적합도에 미치는 영향 (Influence of final crystallization process on precision of fit of monolithic CAD/CAM-generated restorations by lithium disilicate: A comparative study)

  • 김재홍;김기백
    • 대한치과기공학회지
    • /
    • 제41권4호
    • /
    • pp.271-278
    • /
    • 2019
  • Purpose: To quantify the effect of the crystallization process on lithium disilicate ceramic crowns that are fabricated using a computer-aided design/computer-aided manufacturing(CAD/CAM) system, and to determine whether they are clinically acceptable by comparing values before and after the crystallization process. Methods: The maxillary first molar was selected as the abutment for the experiments. Ten working models were prepared. Marginal and internal gap of 4 groups of lithium disilicate crowns(n=10) fabricated with conventional method. Comparison was performed using the silicone replica technique and 3D superimposition analysis. The marginal and internal gaps of the restoration were measured before and after the crystallization process of this prosthesis. The average value of each part(the average of values measured before and after the crystallization) was statistically analyzed using paired t-test(α=0.05). Results: The results from the second phase of this research, which compared the average value of the gap between the marginal and internal fits of the lithium disilicate single crown before and after the crystallization process, indicated that the marginal gap was larger and the internal gap was smaller after the crystallization process, and this difference was statistically significant (P<0.05) in all the parts evaluated. Conclusion: While the shrinkage that occurs during crystallization does affect the marginal and internal fit of the prosthesis, it cannot be concluded to be a major effect because the resultant distortion was within the clinically acceptable range.

국산 치과용 구강스캐너(e-scanner)와 모델스캐너의 정확도 비교 (Comparison of the accuracy of domestic dental intra-oral scanner(e-scanner) and model scanner)

  • 김부섭;김정호
    • 대한치과기공학회지
    • /
    • 제41권2호
    • /
    • pp.53-61
    • /
    • 2019
  • Purpose: The purpose of this study is to evaluate the discrepancy of scan process in dental intra oral scanner by comparing model scanner and anticipate possibility to introduce intra oral scan technique. Methods: 3D superimposition test was conducted to compare the scan discrepancy. The scanners used in this study are the e-oral scanner, the D750 model scanner, and the high precision CMM(3D Coordinate Measuring Machine). The standard of accuracy verification is ISO 5725-1; trueness and precision. Master model was manufactured by dental stone and scanned 5 times by intra oral, model scanner. Reference data was scanned 5 times by high accuracy CMM to evaluate the trueness. Results: Trueness of D750 scanner were $7.4{\mu}m$ $5.1{\mu}m$ $6.8{\mu}m$ at an abutment, an occluasal, a specific area. and trueness of e-scanner were $20.2{\mu}m$ $27.4{\mu}m$ $37.8{\mu}m$ at an abutment, an occluasal, a specific area. Precision of D750 scanner was $7.04{\mu}m$, e-scanner was $15.95{\mu}m$. Conclusion: When conducting in vitro test, The mean difference of trueness between e-scanner and D750 were $12.8{\mu}m$ at an abutment area, $22.3{\mu}m$ at an occlusal area, $31.0{\mu}m$ at a specific area and $8.91{\mu}m$ in precision. The scan discrepancies are within the range of clinical acceptance.

3D 프린팅 및 밀링 방법으로 제작된 임시 보철물 적합도 비교 분석 (Marginal and internal fit of interim crowns fabricated with 3D printing and milling method)

  • 손영탁;손큰바다;이규복
    • 구강회복응용과학지
    • /
    • 제36권4호
    • /
    • pp.254-261
    • /
    • 2020
  • 목적: 본 연구의 목적은 서로 다른 제작 방법인 절삭 가공과 적층 가공 기술로 제작된 임시 보철물의 변연 및 내면 적합도를 평가하는 것이다. 연구 재료 및 방법: 상악 우측 제1대구치를 도재 수복을 위한 지대치 모형으로 준비하였다. 석고를 이용하여 총 40개의 실험 모형으로 복제하였고, 각각의 실험 모형을 구강 스캐너를 사용하여 스캔 데이터를 획득하였다. 3종의 3D 프린터(Meg-printer 2; Megagen, Zenith U; Dentis 그리고 Zenith D; Dentis) 및 1종의 밀링 장비(imes-icore 450i; imes-icore GmbH)를 사용하여 각 그룹당 10개의 임시 보철물을 제작하였다. 임시 보철물의 내면에 실리콘을 채우고 모형에 적합하여 중합이 완료된 후, 실리콘으로 내면이 복제되어 있는 실험 모형을 구강 스캐너를 사용하여 스캔 데이터를 획득하였다. 3차원 검사 소프트웨어(Geomagic control X; 3D Systems)를 이용하여 변연 간격, 절대 변연 간격, 섐퍼, 축벽, 교두, 교합 영역의 적합도를 분석하였다. 통계 분석은 제작 방법의 차이를 비교하기 위해서 Kruskal-Wallis test를 사용하여 검증하였으며, 사후 검정을 위해서 Mann-Whitney U-test and Bonferroni correction method을 사용하였다(α = 0.05). 결과: 3종의 3D 프린터와 1종의 밀링 장비에서 제작된 임시 보철물의 절대 변연 간격은 유의한 차이를 보이지 않았다(P = 0.812). 축벽, 교합 간격에서 밀링 장비와 3D 프린터 사이에 유의한 차이를 보였다(P < 0.001). 결론: 3종의 3D 프린터로 제작된 임시 보철물의 변연 적합도는 모두 임상적 허용 범위(< 120 ㎛)에 있었으므로, 적합도 측면에서 본다면 임시 보철물 제작을 위해서 충분히 사용될 수 있다.