• Title/Summary/Keyword: Sub-module test

Search Result 67, Processing Time 0.025 seconds

Reliability Analysis of A System Based on the Execution Characteristics of sub-Modules (동작 특성 기반의 시스템 신뢰도 분석)

  • Na, Yun-Ji;Ko, Il-Seok;Cho, Yong-Hwan
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.27 no.2C
    • /
    • pp.143-149
    • /
    • 2002
  • Complexity of the hardware system grows larger, the fault testing becomes more difficult. As we divide system into the functional sub-modules and analyze reliability of a sub-modules on the system, We improve the system test performance. And the analysing results help us to set up the effective strategies for the system test. Also describing the system to a formalized sub-modules, we can analyze the logical accuracy and the characteristics of system. So we can predict the reliability of the system based on execution characteristics. In this paper we propose a reliability analysis method of a system based on the execution characteristics of sub-module.

Gas Pulsation Analysis in a T-Shaped Suction Passage of a CO2 Twin Rotary Compressor (CO2 트윈 로타리 압축기의 흡입관로에서의 가스맥동 해석)

  • Kim, Woo-Young;Ahn, Jong-Min;Kim, Hyun-Jin;Cho, Sung-Oug
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.8
    • /
    • pp.549-555
    • /
    • 2011
  • For a $CO_2$ one-stage twin rotary compressor, a T-shaped suction port was used to effectively supply the suction gas stream into two individual suction chambers of the twin cylinders. Suction gas pulsations were observed in the pressure sensor signals and these were simulated by using the acoustic modeling of Helmholz resonators in parallel. The module of acoustic modeling was combined to a computer simulation program for the compressor performance. Validation of the simulation program has been carried out for a bench model compressor in a compressor calorimeter. Cooling capacity and the compressor input power were reasonably well compared between the simulation and the calorimeter test. Particularly, good agreement on P-V diagram between the simulation and the test was obtained.

Mitigation of Potential-Induced Degradation (PID) for PERC Solar Cells Using SiO2 Structure of ARC Layer (반사방지막(ARC)의 SiO2 구조에 따른 PERC 태양전지 PID 열화 완화 상관관계 연구)

  • Oh, Kyoung Suk;Park, Ji Won;Chan, Sung Il
    • Current Photovoltaic Research
    • /
    • v.8 no.4
    • /
    • pp.114-119
    • /
    • 2020
  • In this study, Mitigation of Potential-induced degradation (PID) for PERC solar cells using SiO2 Structure of ARC layer. The conventional PID test was conducted with a cell-level test based on the IEC-62804 test standard, but a copper PID test device was manufactured to increase the PID detection rate. The accelerated aging test was conducted by maintaining 96 hours with a potential difference of 1000 V at a temperature of 60℃. As a result, the PERC solar cell of SiO2-Free ARC structure decreased 22.11% compared to the initial efficiency, and the PERC solar cell of the Upper-SiO2 ARC structure decreased 30.78% of the initial efficiency and the PID reliability was not good. However, the PERC solar cell with the lower-SiO2 ARC structure reduced only 2.44%, effectively mitigating the degradation of PID. Na+ ions in the cover glass generate PID on the surface of the PERC solar cell. In order to prevent PID, the structure of SiNx and SiO2 thin films of the ARC layer is important. SiO2 thin film must be deposited on bottom of ARC layer and the surface of the PERC solar cell N-type emitter to prevent surface recombination and stacking fault defects of the PERC solar cell and mitigated PID degradation.

Manufacturing and Performance Test of Valve for MMC STATCOM (MMC STATCOM의 Valve 제작 및 시험)

  • Lee, Doo-Young;Park, Yong-Hee;Jeong, Jong-Kyou;Kim, June-Sung
    • Proceedings of the KIPE Conference
    • /
    • 2015.07a
    • /
    • pp.510-511
    • /
    • 2015
  • MMC(Modular Multilevel Converter)형 STATCOM 개발을 위해서는 시스템을 이루는 핵심 구성 요소인 Valve의 설계 및 신뢰성 검증이 매우 중요하다. Valve란 다수의 Sub-module을 직렬로 연결, 조합한 것이며 시스템의 용량에 따라 모듈의 직렬 개수가 정해진다. 그러므로 Valve의 최적 설계 및 제어가 시스템의 성능을 개선할 수 있는 주요 항목으로 작용한다. 본 논문에서는 이러한 Valve를 제작한 내용과 시험 설비를 통해 수행된 제품의 운전 특성에 대해서 기술하였다.

  • PDF

Study on Sn-Ag-Fe Transient Liquid Phase Bonding for Application to Electric Vehicles Power Modules (전기자동차용 파워모듈 적용을 위한 Sn-Ag-Fe TLP (Transient Liquid Phase) 접합에 관한 연구)

  • Byungwoo Kim;Hyeri Go;Gyeongyeong Cheon;Yong-Ho Ko;Yoonchul Sohn
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.30 no.4
    • /
    • pp.61-68
    • /
    • 2023
  • In this study, Sn-3.5Ag-15.0Fe composite solder was manufactured and applied to TLP bonding to change the entire joint into a Sn-Fe IMC(intermetallic compound), thereby applying it as a high-temperature solder. The FeSn2 IMC formed during the bonding process has a high melting point of 513℃, so it can be stably applied to power modules for power semiconductors where the temperature rises up to 280℃ during use. As a result of applying ENIG surface treatment to both the chip and substrate, a multi-layer IMC structure of Ni3Sn4/FeSn2/Ni3Sn4 was formed at the joint. During the shear test, the fracture path showed that cracks developed at the Ni3Sn4/FeSn2 interface and then propagated into FeSn2. After 2hours of the TLP joining process, a shear strength of over 30 MPa was obtained, and in particular, there was no decrease in strength at all even in a shear test at 200℃. The results of this study can be expected to lead to materials and processes that can be applied to power modules for electric vehicles, which are being actively researched recently.

The Effects of Preclinical Objective Structured Clininal Examination(OSCE) on Knowledge, Nursing Students Confidence in Core Fundamental Nursing Skills and Self-Efficacy (임상실습 전 객관화된 구조화 임상수행평가(OSCE)가 간호대학생의 지식, 핵심기본간호술 자신감 및 자기효능감에 미치는 효과)

  • Son, Yu-Lim;Park, Pil-Nam;Ko, Soon-Hee
    • Journal of Korean Clinical Health Science
    • /
    • v.5 no.2
    • /
    • pp.850-863
    • /
    • 2017
  • Purpose. The purpose of this study was to investigate effects of preclinical OSCE(Objective Structured Clinical Evaluation) on knowledge, confidence in their Core fundamental nursing skills and self-efficacy in nursing students. Method. The research design was a one group pretest-posttest design and it was done to assess changes in knowledge, confidence in core fundamental nursing skills and self-efficacy from pre to the post-test which was given after the OSCE. Data were collected from March 5 to April 7, 2016 from 37 nursing students who were taking the 15-hours using OSCE learning module at one Gyeongbuk-do, P-city. This practicum was composed of 4 core fundamental nursing skills and 5 other fundamental nursing skills. The knowledge consisted of a 10-item by researchers and the confidence of core fundamental nursing skills consisted of an 9-item NRS and the self-efficacy consisted of a 17-item 5-point scale and measured in both the pretest and posttest. The collected data were analyzed with SPSS IBM 20.0 program for the frequency, percentage, x2-test, and paired t-test. Rusult. The results showed that although scores of knowledge of OSCE learning module were significanlty increased from 5.22 to 7.03(t=5.30, p<.001). There were significantly increased in scores of confidence in core fundamental nursing skills from 5.13 to 7.27(t=10.01, p<.001), In the sub-scales of each core fundamental nursing skills was scored the highest. otherwise, there was no significant difference in self-efficacy(t=1.42, p=.161). Conclusions. Based on the results, this study suggests that OSCE module development activities for nursing students in nursing education-learning in order to improve nursing skills.

The Study on the Embedded Active Device for Ka-Band using the Component Embedding Process (부품 내장 공정을 이용한 5G용 내장형 능동소자에 관한 연구)

  • Jung, Jae-Woong;Park, Se-Hoon;Ryu, Jong-In
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.28 no.3
    • /
    • pp.1-7
    • /
    • 2021
  • In this paper, by embedding a bare-die chip-type drive amplifier into the PCB composed of ABF and FR-4, it implements an embedded active device that can be applied in 28 GHz band modules. The ABF has a dielectric constant of 3.2 and a dielectric loss of 0.016. The FR-4 where the drive amplifier is embedded has a dielectric constant of 3.5 and a dielectric loss of 0.02. The proposed embedded module is processed into two structures, and S-parameter properties are confirmed with measurements. The two process structures are an embedding structure of face-up and an embedding structure of face-down. The fabricated module is measured on a designed test board using Taconic's TLY-5A(dielectric constant : 2.17, dielectric loss : 0.0002). The PCB which embedded into the face-down expected better gain performance due to shorter interconnection-line from the RF pad of the Bear-die chip to the pattern of formed layer. But it is verified that the ground at the bottom of the bear-die chip is grounded Through via, resulting in an oscillation. On the other hand, the face-up structure has a stable gain characteristic of more than 10 dB from 25 GHz to 30 GHz, with a gain of 12.32 dB at the center frequency of 28 GHz. The output characteristics of module embedded into the face-up structure are measured using signal generator and spectrum analyzer. When the input power (Pin) of the signal generator was applied from -10 dBm to 20 dBm, the gain compression point (P1dB) of the embedded module was 20.38 dB. Ultimately, the bare-die chip used in this paper was verified through measurement that the oscillation is improved according to the grounding methods when embedding in a PCB. Thus, the module embedded into the face-up structure will be able to be properly used for communication modules in millimeter wave bands.

Thermal and telemetry module design for satellite camera

  • Kong, Jong-Pil;Yong, Sang-Soon;Heo, Haeng-Pal;Kim, Young-Sun;Youn, Heong-Sik
    • Proceedings of the KSRS Conference
    • /
    • 2002.10a
    • /
    • pp.229-234
    • /
    • 2002
  • Under the hostile influence of the extreme space environmental conditions due to the deep space and direct solar flux, the thermal control in space applications is especially of major importance. There are tight temperature range restrictions for electro-optical elements while on the other hand there are low power consumption requirements due to the limited energy sources on the spacecraft. So, we usually have strong requirement of thermal and power control module in space applications. In this paper, the design concept of a thermal and power control module in the MSC(Multi-Spectral Camera) system which will be a payload on KOMPSATII is described in terms of H/W & S/W. This thermal and power control module, called THTM(Thermal and Telemetry Module) in MSC, resides inside the PMU(Payload Management Unit) which is responsible for the proper management of the MSC payload for controlling and monitoring the temperature insides the EOS(Electro-Optic System) and gathering all the analog telemetry from all the MSC sub-units, etc. Particularly, the designed heater controller has the special mode of "duty cycle" in addition to normal closed loop control mode as usual. THTM controls heaters in open loop according to on/off set time designed through analysis in duty cycle mode in case of all thermistor failure whereas it controls heaters by comparing the thermistor value to temperature based on closed loop in normal mode. And a designed THTM provides a checking and protection method against the failure in thermal control command using the test pulse in command itself.

  • PDF

Preparation and Properties of Hollow Fiber Membrane for CO2/H2 Separation (이산화탄소/수소 분리용 중공사형 기체분리막의 제조 및 특성)

  • Hyung Chul Koh;Mi-jin Jeon;Sang-Chul Jung;Yong-Woo Jeon
    • Membrane Journal
    • /
    • v.33 no.4
    • /
    • pp.222-232
    • /
    • 2023
  • In this study, a hollow fiber support membrane was prepared by a non-solvent induced phase separation (NIPS) method using a polysulfone (PSf). The prepared hollow fiber support membrane was coated with PDMS and Pebax to prepare a hollow fiber composite membrane. The prepared composite membrane was measured for permeance and selectivity for pure CO2, H2, O2 and N2. Gas separation performance of the module having the highest selectivity (CO2/H2) among the prepared composite membrane modules was measured according to the change in stage cut using simulated gas. The composition of the simulated gas used at this time was 70% CO2 and 30% H2. In the 1 stage experiment, it was possible to obtain values of about 60% of H2 concentration and 12% of H2 recovery. In order to overcome the low H2 concentration and recovery, 2 stage serial test was performed, and through this, it was possible to achieve 70% H2 concentration and 70% recovery. Through this, it was possible to derive a separation process configuration for CO2/H2 separation.

Performance Test Circuit and Control Method for Submodule of MMC-HVDC System (MMC-HVDC 시스템용 서브모듈 성능시험회로와 제어기법)

  • Jo, Kwang-Rae;Seo, Byuong-Jun;Park, Kwon-Sik;Kim, Hak-Soo;Heo, Jin-Yong;Nho, Eui-Cheol
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.24 no.6
    • /
    • pp.452-458
    • /
    • 2019
  • This study proposes a new test circuit and control method for the submodules of modular multilevel converter (MMC)-based HVDC systems. The test current of conventional submodule test circuits cannot provide the DC offset components or may have some distortion in the linearized current with the DC offset. The proposed scheme can provide not only the DC component but also linearized current without distortion. Therefore, the submodule test current waveform is relatively similar to that of a real submodule consisting of an MMC-based HVDC system. The validity of the proposed circuit and control method is verified through a simulation and experiment.