• 제목/요약/키워드: Structure Stability

검색결과 4,017건 처리시간 0.038초

Pseudo-static stability analysis of wedges based on the nonlinear Barton-Bandis failure criterion

  • Zhao, Lianheng;Jiao, Kangfu;Zuo, Shi;Yu, Chenghao;Tang, Gaopeng
    • Geomechanics and Engineering
    • /
    • 제20권4호
    • /
    • pp.287-297
    • /
    • 2020
  • This paper investigates the stability of a three-dimensional (3D) wedge under the pseudo-static action of an earthquake based on the nonlinear Barton-Bandis (B-B) failure criterion. The influences of the mechanical parameters of the discontinuity surface, the geometric parameters of the wedge and the pseudo-static parameters of the earthquake on the stability of the wedge are analyzed, as well as the sensitivity of these parameters. Moreover, a stereographic projection is used to evaluate the influence of pseudo-static direction on instability mode. The parametric analyses show that the stability coefficient and the instability mode of the wedge depend on the mechanical parameter of the rock mass, the geometric form of the wedge and the pseudo-static state of the earthquake. The friction angle of the rock φb, the roughness coefficient of the structure surface JRC and the two angles related to strikes of the joints θ1 and θ2 are sensitive to stability. Furthermore, the sensitivity of wedge height h, the compressive strength of the rock at the fracture surface JCS and the slope angle α to the stability are insignificant.

풍화된 변성암 사면의 안정대책 사례 (Case of slope stability in weathered metamorphic rock)

  • 김재홍;박철숙;전제성;홍원표
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2008년도 춘계 학술발표회 초청강연 및 논문집
    • /
    • pp.1400-1405
    • /
    • 2008
  • Execute surface of the earth geological survey for stability analysis of stealing cutting sides and investigated wide area nature of soil structure. Inflected DIPS that measure discontinuity's direction that develop to slope and is slope stability a wide use program for Stereographic Projection Method analysis that utilize geometrical correlation of stealing four sides and discontinuity surface. It is principle that angle of internal friction that is basis element of stability estimation applies direct shear test result on joint side, Examination is impossible by case execution, suppose by 30 angles that apply more conservatively in base rock slope sides usually and achieved analysis. When analyze, consider discontinuity's various adult that develop in research slope, after conduct first each discontinuity different assay falling into fault, joint, executed stability estimation which synthesize whole discontinuity data. When ailment element is recognized as analysis result, wished to present stability countermeasure way of most suitable to take into account of execution, stability, economic performance.

  • PDF

콘크리트 구조물의 유지보수에 사용되는 누수보수재료의 인공 균열을 이용한 온도 안정성 시험평가 (Thermal Stability Test Evaluation of Applying the Artificial-Crack of Water-Leakage Repair Materials Used in the Maintenance of Concrete Structure)

  • 김수연;김병일;오상근
    • 한국건설순환자원학회논문집
    • /
    • 제4권3호
    • /
    • pp.322-329
    • /
    • 2016
  • 본 연구에서는 콘크리트 구조물의 누수 균열 보수에 사용되는 재료에 대한 품질관리 방안으로 선행연구에 이어 후속 연구로 "온도 안정성 시험방법"을 제안하였다. 제안된 시험방법을 이용하여 5계열의 15 종류, 총 45개의 시험편을 대상으로 성능 평가한 결과 온도 안정성 시험에서는 저온($-20^{\circ}C$), 고온($60^{\circ}C$)의 다소 가혹 조건의 온도에서 얼었다 녹았다가 반복되면서 흘러내림, 체적변화, 색의 변화 등 다양한 재료 변화가 나타났고, 이에 대한 누수 여부 판별을 위하여 투수 시험한 결과 약 29%인 13개의 시료는 누수 되지 않았고, 약 71%인 32개 시료에서 누수되는 결과가 확인되었다. 이러한 결과는 현재 콘크리트 구조물의 유지보수에 사용되는 누수보수재료에 대한 온도 환경이 고려된 품질관리 기준 설정에 대한 필요성을 충분히 인식 할 수 있었으며, 콘크리트 구조물의 장기 내구성 확보를 위한 본 시험 방법인 "온도 안정성 시험방법"에 대한 표준적인 시험방법으로서의 활용 가능성을 확인하였다.

VI-GNSS 지하구조물 현장정보 네트워크 아키텍쳐 설계 (Design of Network Architecture in Underground Structure Field Information Based on VI-GNSS)

  • 전흥수;장용구;오창균;김민관
    • 한국지리정보학회지
    • /
    • 제18권1호
    • /
    • pp.64-73
    • /
    • 2015
  • 최근 들어, 건설현장에서의 안전사고에 대한 예방 및 신속한 대응과 함께 현장관리의 효율화를 위해서 IT와의 통합적 활용이 요구되고, 작업자의 안전 확보와 원활한 작업지시 그리고 시공의 효율성 등을 구현하기 위한 건설현장지원시스템의 구축이 필요하다. 본 연구에서는 현재 VI-GNSS(Voice Integrated-Global Navigation Satellite System)통합기술 기반의 지하구조물 건설현장지원시스템(USFSS, Underground Structure Field Support System)구축을 위하여 시스템 간 정보 전송 및 관리를 위해 데이터 및 음성정보에 대한 정보 표준화와 네트워크 아키텍쳐를 설계하였다. 이를 통하여 구축된 시스템별 정보의 안정성 테스트에서 데이터 전송 안정성의 경우 지하구조물 내 작업자 및 이동차량 시스템과 현장서버시스템에서는 각각 약 98%, 현장서버시스템과 관제시스템사이의 안정성은 약 100%를 확보할 수 있었다. 또한, 음성 전송 안정성 테스트에서 FRS(Family Radio Station)무선시스템을 통한 지하구조물 건설현장과 현장 주변 현장사무소까지의 음성 전송의 경우 1km 거리 구간을 기준으로 약 99%의 신뢰성을 확보하였다.

근대건축의 구조시스템과 건축적 특성에 관한 연구 (A Study on The Structural Systems of Modern Architecture and Architectural Characteristics)

  • 조성현
    • 한국디지털건축인테리어학회논문집
    • /
    • 제10권1호
    • /
    • pp.49-56
    • /
    • 2010
  • The purpose of this study is to examine the relationship between the structural system used in modern architecture and the form and spatial composition of the buildings. The principle in stabilization of structures is closely related to the architectural form. That is, in order to stabilize a building, a special type of structural system is required and consequently shows up with consistent characteristics in the architectural form. Modern architecture can be classified into skeleton structure, trusses structure, and space structure according to the structural characteristics. Skeleton structure is then divided into a perpendicular form and tapered form. Trusses structure is categorized as dome-shaped structure and slab-shaped structure, and space structure can be divided into compressible space structure and tensile space structure. When classifies the modern building with the aspect of architectural effect, there is a possibility of trying to divide with effect of production, and its expression. Effect of production mean structural system and effect of expression mean space and plan.

The Influence of Hydrotalcite Intercalated with Benzoate on UV Stability of Acrylic Coating

  • Nguyen, Thuy Duong;Nguyen, Anh Son;Thai, Thu Thuy;Pham, Gia Vu;To, Thi Xuan Hang;Olivier, Marie-Georges
    • Corrosion Science and Technology
    • /
    • 제19권1호
    • /
    • pp.16-22
    • /
    • 2020
  • It is important to realize that benzoate was intercalated into hydrotalcite (HTC-Bz) by the co-precipitation method. In this case, acrylic coating with 0.5 wt% HTC-Bz was deposited on carbon steel using the spin coating method. Next, the HTC-Bz structure was characterized by Field emission scanning electron microscopy (FESEM), X-ray diffraction (XRD), and Fourier transform infrared spectroscopy (FT-IR). In fact, an ultraviolet vision spectroscopy (UV-Vis) was used to determine the benzoate content in HTC-Bz, and the UV absorption ability of HTC-Bz. Using electrochemical techniques, water contact angle measurement, and thermal-gravimetric analysis, we compared the protective properties before and after QUV test, hydrophobicity and the thermal stability of acrylic coating containing HTC-Bz. The obtained results showed that HTC-Bz with a plate-like structure was successfully synthesized; benzoate was intercalated into the interlayer of hydrotalcite with a concentration of 28 wt%. Additionally, it was noted that HTC-Bz has an UV absorption peak at 225 nm. In conclusion, the addition of HTC-Bz enhanced the UV stability, hydrophobicity and the thermal stability of acrylic coating.

사면의 지반 열화로 인한 안정성 평가에 관한 연구 (A Study on the Evaluation of Stability due to Ground Deterioration of Slope)

  • 한영철
    • 한국지반공학회논문집
    • /
    • 제34권12호
    • /
    • pp.83-92
    • /
    • 2018
  • 사면 구조물은 시간이 경과함에 따라 대상지반에서 각종 열화 현상이 진행되어 내구성의 저하로 인한 붕괴가 발생할 수 있으며, 사용 연한을 감소시키는 결과를 초래하게 된다. 이러한 지반 열화에 따른 사면안정에 대한 접근방안은 지반의 물리적 특성 및 기하학적인 구조에 국한하여 분석하는 기존의 한계 평형 해석과는 또 다른 개념이라 할 수 있다. 본 연구에서는 사면의 열화 특성과 관련하여 각종 문헌 조사를 통하여 비교분석을 수행하고, 전단강도 저감에 대한 최적의 제안식들로서 지수함수, 로그함수 및 역쌍곡선 함수를 제시하고, 열화에 취약한 양산 단층대의 셰일층에서 붕괴가 발생한 경부고속철도 절토사면을 대상으로 사례분석을 실시하였다. 본 연구에서는 사례분석을 통하여 향후 열화로 인한 사면 안전성과 관련하여 정량적인 평가를 위한 최적의 강도 저하 곡선을 도출하고 한계평형해석에 의한 안정해석을 할 수 있는 접근 방법을 제시하였다.

Variable structure control for matched and unmatched uncertainty with quadratic criterion

  • Rhee, Bond-Jae;Park, Ju-Hyun;Won, Sangchul
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1997년도 한국자동제어학술회의논문집; 한국전력공사 서울연수원; 17-18 Oct. 1997
    • /
    • pp.458-463
    • /
    • 1997
  • In this paper, we propose a variable structure control approach for the system with matched and unmatched uncertainty. By using time-varying sliding mode, the reaching mode is removed, and the design methodology represents a realistic design approach with quadratic criterion for systems incorporating both matched and unmatched uncertainties. The criterion contains states and linear part of input for all time. The practical application of the control strategy is presented in the design of a stability augmentation system for an aircraft is presented.

  • PDF

강인성과 응답 성능을 고려한 슬라이딩모드 퍼지 제어기 설계에 관한 연구 (A New Design Method of Sliding Mode Fuzzy Controller with Robust and fast Performance)

  • 박창우;이장욱
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 1998년도 추계종합학술대회 논문집
    • /
    • pp.425-428
    • /
    • 1998
  • This paper proposes a new fuzzy controller using variable structure control theory. In this paper, after the time-varying fuzzy sliding surface is designed, the fuzzy rules are defined based on the variable structure control theory. This design method makes the fuzzy controller design more structured and can guarantee the stability and robustness of the fuzzy controller and overcome the shortcoming of the variable structure system. Through computer simulation and experiment of nonlinear inverted pendulum system, this thesis demonstrate that system has the robustness against disturbance and modelling error, and the tracking performance of it is improved.

  • PDF

안정한 비최소 위상 시스템의 견실한 적응제어 (Robust adaptive control for a stable nonminimum phase system)

  • 최종호;김호찬
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1988년도 한국자동제어학술회의논문집(국내학술편); 한국전력공사연수원, 서울; 21-22 Oct. 1988
    • /
    • pp.255-260
    • /
    • 1988
  • A robust adaptive control method for a stable nonminimum phase SISO system with unmodelled dynamics is proposed. The robust parameter estimation method of the system with bounded output noise and unmodelled dynamics is employed and a parallel structure is proposed to improve the robustness of adaptive control system. The local stability of the proposed system is shown. Computer simulations are done in order to compare the performance of the proposed structure with the basic structure on various circumstance.

  • PDF