Thermal Stability Test Evaluation of Applying the Artificial-Crack of Water-Leakage Repair Materials Used in the Maintenance of Concrete Structure  

Kim, Soo-Youn (Department of Convergence Institute of Biomedical Engineering and Bio materials Program of Architecture Doctoral Course, Seoul National University of Science and Technology)
Kim, Byoung-ll (Department of Civil Engineering, Seoul National University of Science and Technology)
Oh, Sang-Keun (Department of Civil Engineering, Seoul National University of Science and Technology)
Publication Information
Journal of the Korean Recycled Construction Resources Institute / v.4, no.3, 2016 , pp. 322-329 More about this Journal
Abstract
This study is about the method to control the quality of material used to repair leakage and crack of concrete structure and suggests the "Temperature Stability Test Method" as a follow-up study. In the result of performance evaluation for 45 samples of 15 types in 5 series, the temperature stability test showed different material changes including rolling down, volume change, and color change as they are frozen and melt repeatedly in the somewhat extreme conditions at low($-20^{\circ}C$) and high($60^{\circ}C$) temperatures, where 13 samples (approx. 29%) and 32 samples (approx. 71%) showed leakage, respectively, in the permeability test to evaluate leakage. This result shows the enough importance of setting the quality control criteria of leakage repair material currently used to maintain concrete structures considering the temperature conditions, and proves the applicability of the Temperature Stability Test Method as a standard test method to ensure long-term durability of concrete structure.
Keywords
Concrete structure; Water-leakage; Repair material; Thermal stability; Artificial-crack;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 ISO TR 16475. (2011). Guidelines for the repair of water-leakage cracks in concrete structures, International Organization for Standardization, 2nd Ed., Switzerland.
2 ISO TR 16475. (2011). Guidelines for the repair of water-leakage cracks in concrete structures, ISOTC71, Switzerland.
3 Jung, W.S., Ali Khan, M., Jeon, Y.H. (2010). A study on the geochemical behaviors of FE (ll) and As (V) in underground environment, Korean Soc. Eng. Geol., 337-340 [in Korean].
4 Kim, S.Y., Han, Y.J., Oh, K.W., Kim, B.l., Oh, S.K. (2016a). Studies on the testing evaluation of thermal stability of waterproofing repair materials used in concrete structure cracks and joints areas, Architectural Institute of Korea, 981-982 [in Korean].
5 Kim, S.Y., Oh, S.K., Kim, B.l. (2016b). Artificial-crack-behavior test evaluation of the water-leakage repair materials used for the repair of water-leakage cracks in concrete structure, MDPI AG Appl. Sci., 253, doi:10.3390/app6090253, Switzerland.   DOI
6 KS F 4935. (2008). Sealer of injection type for water leakage maintenance of adhesive flexible rubber asphalt series, Korean Agency for Technology and Standards [in Korean].
7 Kwon, S.W., Oh, M.H., Kwat, K.S., Oh, S.K. (2006). Sealer of injection type for water leakage maintenance of adhesive flexible rubber asphalt series, The Korea Institute of Building Construction, 6(1), 87-91 [in Korean].   DOI
8 Oh, S.K. (2002). A new approach on waterproofing and water-leakage repair technology of concrete structure, Korea Concrete Institute, 101-118 [in Korean].
9 Oh, S.K., Cho, S.M., Song, J.Y., Park, J.S., Kim, S.Y., Lee, J.H., An, K.W. (2014). Apartment house basement waterproofing construction method optimization suggestions and new technology research, Korea Land & Housing Corporation, 47-143 [in Korean].
10 Oh, S.K., Lee, J.Y., Park, K.B., Oh, J.S. (2012). Water-leakage maintenance technology and case of architecture as structure, Korea Infrastructure Safety & Technology Corporation [in Korean].