• Title/Summary/Keyword: Stress Recovery

Search Result 666, Processing Time 0.023 seconds

A simple energy recovery circuit with current-fed type for plasma display panel (PDP) (간단한 전류원 형태의 구조를 갖는 새로운 PDP 에너지 회수 회로)

  • Yi, Kang-Hyun;Han, Sang-Kyoo;Choi, Seong-Wook;Kim, Chong-Eun;Moon, Gun-Woo
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.376-379
    • /
    • 2005
  • High efficiency and low cost sustain driver for plasma display panel (PDP) with current fed is proposed. Main concept of the proposed circuit is using the current source to charge and discharge panel. As a result, all power switches can achieve the zero voltage switching (ZVS) and every auxiliary switch can also do the zero current switching (ZCS). Moreover, since the inductor current can compensate the discharge current, the current stress of all power switches can be reduced considerably. Furthermore, it has features as a simpler structure, less mass, less cost, and lower electromagnetic interference than prior circuit.

  • PDF

Half-Bridge Zero Voltage Switching Converter with Three Resonant Tanks

  • Lin, Bor-Ren;Lin, Wei-Jie
    • Journal of Power Electronics
    • /
    • v.14 no.5
    • /
    • pp.882-889
    • /
    • 2014
  • This paper presents a zero voltage switching (ZVS) converter with three resonant tanks. The main advantages of the proposed converter are its ability to reduce the switching losses on the power semiconductors, decrease the current stress of the passive components at the primary side, and reduce the transformer secondary windings. Three resonant converters with the same power switches are adopted at the low voltage side to reduce the current rating on the transformer windings. Using a series-connection of the transformer secondary windings, the primary side currents of the three resonant circuits are balanced to share the load power. As a result, the size of both the transformer core and the bobbin are reduced. Based on the circuit characteristics of the resonant converter, the power switches are turned on at ZVS. The rectifier diodes can be turned off at zero current switching (ZCS) if the switching frequency is less than the series resonant frequency. Therefore, the reverse recovery losses on the rectifier diodes are overcome. Experiments with a 1.6kW prototype are presented to verify the effectiveness of the proposed converter.

A study on the characteristics of end region flow field for partially cavitating hydrofoil (익형에 발생하는 부분 캐비테이션 후연영역 유동장 특성 연구)

  • 문철진;김시영
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.12 no.1
    • /
    • pp.53-61
    • /
    • 1988
  • Most of the recent for the flow field hydrofoil in partially cavitating condition are the ones which are linearized, and the problem of cavity end region for hydrofoil is not verified. This paper deals with a study on characteristics of end region flow field for partially cavitating hydrofoil by using a characteristics of shear turbulence flow and nonlinear cavity flow theory. The results obtained as follows : 1) Shear layer thickness is decreased gradually going to the end section of hydrofoil. When attack angle is large, it is appeared largely at the region of partial cavitation after its collapsing. 2) The fluctuation velocity of a second-degree relative direction have minimum value at the front of hydrofoil or at the end of hydrofoil. The difference for the validity of attack angle is appeared largely at the surrounding of .chi.$_{e}$ point. 3) The fluctuation velocity of transverse direction decrease from the maximum thickness of cavitation to the end of hydrofoil, but it undergoes largely the effect of pressure recovery. The difference is larger at the region of partial cavitation after its collapsing than at the of hydrofoil. 4) The distribution of Reynolds stress have maximum values at the region of partial cavitation after its collapsing and the end of foil, and the larger attack angle, the larger the distribution of value.e.

  • PDF

Experiences on Transfer of Critically Ill Patients from Intensive Care Units to General Wards - Focus Group Interview on Nurses' View - (간호사가 인식하는 중환자실 환자의 병동으로의 전실경험 - 포커스 그룹 연구방법 적용 -)

  • Son, Youn-Jung;Suh, Yeon-Ok;Hong, Sung-Kyung
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.16 no.1
    • /
    • pp.92-102
    • /
    • 2009
  • Purpose: Relocation stress is a common phenomenon in patients discharged from an intensive care unit(ICU) to a ward. Therefore, nurses need to be aware of the problems that can arise during the transfer process. The aim of this study was to identify nurses' experiences in transferring critically ill patients from the ICU to a ward. Method: Focus group interviews were done with 13 nurses from wards and ICU, which participated in receiving and sending of ICU patients. The debriefing notes and field notes were analyzed using the consistent comparative data analysis method. Result: Seven major categories were identified in the analysis of the data. These were 'mixed feeling about transfer', 'lack of transfer readiness', 'increase in family burden', 'uncertainty with unfamiliar environment', 'difficulty in decision making', 'difference of perception of the relationships between patients and health care providers', 'need for continuity of nursing care'. Conclusion: Transferring out of the critical care area should be presented to the patient and family as a positive step in the recovery process. However, a more universal method of passing information from nurse to nurse is needed to assist in a smooth transition.

  • PDF

Selection of the Optimum Seaming Condition for Spin Drum Using Statistical Method (통계적 기법을 이용한 스핀드럼의 시밍 최적조건 선정)

  • Kim, Eui-Soo;Lee, Jung-Min;Kim, Byung-Min
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.25 no.1
    • /
    • pp.99-107
    • /
    • 2008
  • There are being a lot of studies for achievement of high speed Dehydration, high-strength and Lightweight of washing machine in the latest washing machine business. It is essential that strength of mechanical press-Joining (MPJ) for spin drum is improved to attain that target. MPJ of spin drum is composed of seaming and caulking process. Because Seaming process of MPJ has various design factors such as thickness, bending radius, seaming width, caulking press width and the dynamic factor such as multistage plastic working, elastic recovery, residual stress, the optimum conditions can't be easily determined. Using a design of experiment (DOE) based on the FEM (Finite Element Method), which has several advantages such as less computing, high accuracy performance and usefulness, this study was performed investigating the interaction effect between the various design factor as well as the main effect of the each design factor during drum MPJ and proposed optimum condition using center composition method among response surface derived from regression equation of simulation-based DOE.

A Novel Switched Capacitor High Step-up dc/dc Converter Using a Coupled Inductor with its Generalized Structure

  • Hamkari, Sajjad;Moradzadeh, Majid;Zamiri, Elyas;Nasir, Mehdi;Hosseini, Seyed Hossein
    • Journal of Power Electronics
    • /
    • v.17 no.3
    • /
    • pp.579-589
    • /
    • 2017
  • In this study a new high step-up dc-dc converter is presented. The operation of the proposed converter is based on the capacitor switching and coupled inductor with a single active power switch in its structure. A passive voltage clamp circuit with two capacitors and two diodes is used in the proposed converter for elevating the converter's voltage gain with the recovered energy of the leakage inductor, and for lowering the voltage stress on the power switch. A switch with a low $R_{DS}$ (on) can be adopted to reduce conduction losses. In the generalized mode of the proposed converter, to reach a desired voltage gain, capacitor stages with parallel charge and series discharge techniques are extended from both sides of secondary side of the coupled inductor. The proposed converter has the ability to alleviate the reverse recovery problem of diodes with circuit parameters. The operating principle and steady-states analyses are discussed in detail. A 40W prototype of the proposed converter is implemented in the laboratory to verify its operation.

Distribution Model Based on Computer Simulation for Internal Temperature and Moisture Content in Press Drying of Tree Disks (원판(圓板)의 열판건조(熱板乾燥)에서 컴퓨터 시뮬레이션에 의한 내부온도(內部溫度)와 함수율(含水率) 분포모형(分布模型))

  • Yeo, Hwan-Myeong;Jung, Hee-Suk
    • Journal of the Korean Wood Science and Technology
    • /
    • v.22 no.2
    • /
    • pp.61-70
    • /
    • 1994
  • This study was executed to find the applicability of press drying of tree disk by investigating the shrinkage and drying defect and to form appropriate model by comparing the actual moisture content(MC) and internal temperature in respect of drying time with calculated values based computer simulation to which was applied finite difference method. In press drying disk, heating period, constant drying rate period maintained plateau temperature at 100$^{\circ}C$ and falling drying rate period were significantly distinguished. Actual MC and internal temperature were analogous to those calculated at comparing points. Heat transfer model formed by Fourier's law using specific heat of moist wood and conduction coefficient considering fractional volume of each element of wood cell wall, bound water, free water and air showed applicability as basic data to developing heat expansion, shrinkage and drying stress during press drying. Also mass transfer model formed by Fick's diffusion law using water vapor diffusion coefficient showed applicability. Longitudinal shrinkage was developed by pressure of hot press and tangential shrinkage was restrained by hygrothermal recovery. The heart check, surface check and ring failure were occurred differently in species, but V-shaped crack didn't develop.

  • PDF

A Secondary Resonance Soft Switching Half Bridge DC-DC Converter with an Inductive Output Filter

  • Chen, Zhang-yong;Chen, Yong
    • Journal of Power Electronics
    • /
    • v.17 no.6
    • /
    • pp.1391-1401
    • /
    • 2017
  • In this paper, a secondary resonance half-bridge dc-dc converter with an inductive output filter is presented. The primary side of such a converter utilizes asymmetric pulse width modulation (APWM) to achieve zero-voltage switching (ZVS) of the switches, and clamps the voltage of the switch to the input voltage. In addition, zero current switching (ZCS) of the output diode is achieved by a half-wave rectifier circuit with a filter inductor and a resonant branch in the secondary side of the proposed converter. Thus, the switching losses and diode reverse-recovery losses are eliminated, and the performance of the converter can be improved. Furthermore, an inductive output filter exists in the converter reduce the output current ripple. The operational principle, performance analysis and design equation of this converter are given in this paper. The analysis results show that the output diode voltage stress is independent of the duty cycle, and that the voltage gain is almost linear, similar to that of the isolation Buck-type converter. Finally, a 200V~380V input, 24V/2A output experimental prototype is built to verify the theoretical analysis.

Small Punch Creep Behavior Analysis for Assessment of Creep Properties (크리프 물성 평가를 위한 소형 펀치 크리프 해석)

  • Im, Jiwoo;Kim, Bum-Joon;Kim, Moon-K;Lim, Byeong-Soo
    • Korean Journal of Metals and Materials
    • /
    • v.48 no.11
    • /
    • pp.965-973
    • /
    • 2010
  • The small punch creep (SPC) test has recently received much attention as a new alternative to the conventional uniaxial creep test because it needs only a miniature-sized specimen directly detached from an operating system or component without any serious sampling damages. However, it is difficult to obtain the equivalent uniaxial creep data directly from the SPC data. As a specimen is deformed by a punch in the SPC test, the test result is sensitive to the friction between them. Finite element analyses with various friction coefficients was performed and showed a tendency of increased SPC life with an increased friction coefficient. The necking position predicted by the SPC simulation with a proper friction coefficient showed good agreement with that observed from the real SPC test. Finally, a noble method to convert the SPC load and displacement rate into the equivalent uniaxial creep stress and strain rate, respectively, was established in this study.

Zero-Voltage and Zero-Current Switching Interleaved Two-Switch Forward Converter

  • Chu, Enhui;Bao, Jianqun;Song, Qi;Zhang, Yang;Xie, Haolin;Chen, Zhifang;Zhou, Yue
    • Journal of Power Electronics
    • /
    • v.19 no.6
    • /
    • pp.1413-1428
    • /
    • 2019
  • In this paper, a novel zero-voltage and zero-current switching (ZVZCS) interleaved two switch forward converter is proposed. By using a coupled-inductor-type smoothing filter, a snubber capacitor, the parallel capacitance of the leading switches and the transformer parasitic inductance, the proposed converter can realize soft-switching for the main power switches. This converter can effectively reduce the primary circulating current loss by using the coupled inductor and the snubber capacitor. Furthermore, this converter can reduce the reverse recovery loss, parasitic ringing and transient voltage stress in the secondary rectifier diodes caused by the leakage inductors of the transformer and the coupled inductance. The operation principle and steady state characteristics of the converter are analyzed according to the equivalent circuits in different operation modes. The practical effectiveness of the proposed converter was is illustrated by simulation and experimental results via a 500W, 100 kHz prototype using the power MOSFET.