• Title/Summary/Keyword: Strength Evaluation

Search Result 4,870, Processing Time 0.032 seconds

Soundness evaluation of friction stir welded A2024 alloy by non-destructive test (비파괴검사에 의한 A2024 마찰교반용접부의 건전성 평가)

  • Ko, Young-Bong;Kim, Gi-Beom;Park, Kyeung-Chae
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.37 no.2
    • /
    • pp.135-143
    • /
    • 2013
  • Friction Stir Welding (FSW) was developed, it is successfully commercialized in the field of transportation vehicles. In this study, we analyzed the defects of A2024-T4 alloy using non-destructive test of radiograph, ultrasonic, electrical conductivity and destructive test of microstructure observation, tensile strength. As the results of experiment, mapping of defects was obtained. Fine defects which were not detected in radiograph test were detected in ultrasonic test, and it enabled efficient detection of defects by difference of sound pressure and color. The values of electrical conductivity was decreased as amount of defects was increasing. Joint efficient of defect-free weldment that found by non-destructive and destructive test was 91%. Therefore it was considered that non-destructive test of friction stir welded A2024-T4 Alloy was an efficient method.

Evaluation of Dynamic Deformation Behaviors in Metallic Materials under High Strain-Rates Using Taylor Bar Impact Test (Taylor 봉 충격시험을 통한 고 변형률속도하 금속재료의 동적변형거동 평가)

  • Bae, Kyung Oh;Shin, Hyung Seop
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.40 no.9
    • /
    • pp.791-799
    • /
    • 2016
  • To ensure the reliability and safety of various mechanical systems in accordance with their high-speed usage, it is necessary to evaluate the dynamic deformation behavior of structural materials under impact load. However, it is not easy to understand the dynamic deformation behavior of the structural materials using experimental methods in the high strain-rate range exceeding $10^4\;s^{-1}$. In this study, the Taylor bar impact test was conducted to investigate the dynamic deformation behavior of metallic materials in the high strain-rate region, using a high-speed photography system. Numerical analysis of the Taylor bar impact test was performed using AUTODYN S/W. The results of the analysis were compared with the experimental results, and the material behavior in the high strain-rate region was discussed.

Experimental Investigations on Micro End-milling Cutting Characteristics Comparison and Tool Wear Behavior of AlN-hBN Composites Sintered by Hot-pressing (열간가압소결에 의해 제조된 AlN-hBN 복합재료의 마이크로 엔드밀링 절삭특성 비교와 공구마모에 관한 실험적 연구)

  • Beck, Si-Young;Shin, Bong-Cheol;Cho, Myeong-Woo;Cho, Won-Seung
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.17 no.4
    • /
    • pp.104-111
    • /
    • 2008
  • The objective of this study is to evaluate micro end-milling characteristics and tool wear behavior of AlN-hBN composites. First, AlN based composites with hBN contents in the range of 10 to 20vol% were prepared by hot-pressing. Vickers hardness and flexural strength of the prepared composite specimens were measured and compared according to the vol% of hBN variations. Then, cutting force variations were measured and analyzed using a tool dynamometer during the micro end-milling experiments; and machined surface shapes and roughness were investigated using a 3D non-contact type surface profiler. After micro end-milling, worn tools were investigated using a tool microscope and SEM images. From the experimental results, it can be observed that the cutting forces decreased, and surface qualities were improved with increasing hBN contents. At low content of hBN, tool chipping was observed; and tool wear rate decreased with increasing hBN contents. The results of this study insist that proper machining conditions, including tool wear behavior investigation, should be determined for the micro end-milling of AlN-hBN composites for its further application.

Microwave Measurement of Complex Permittivity of Dielectric Resonators (초고주파 유전체공진기의 복소유전율 측정)

  • Kim Jeong-Phill;Park, Wee-Sang
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.27 no.11
    • /
    • pp.9-19
    • /
    • 1990
  • A theoretical analysis and measurement technique to determine the complex permittivity and permeability of cylindrical and ring type dielectric resonators is given. The resonant frequency, unloaded quality factor and physical dimensions of dielectric resonator placed between two parallel conducting plates are used to evaluate the complex permittivity and permeability. This process is repeated for other higher-order modes to expand the evaluation at higher resonant frequencies. The nature of each mode is identified by measuring the variations of field strength along the azimuthal and longitudinal direction. An error analysis taking into account various error sources reveals that $TE_{0np}$ or quasi-TE modes yield the least amount of measurement error, which is less than $0.5{\%}$for the real part, $4{\%}$for the imaginary part of complex permittivity.

  • PDF

Modified difficult index adding extremely difficult for fully impacted mandibular third molar extraction

  • Kim, Jae-Young;Yong, Hae-Sung;Park, Kwang-Ho;Huh, Jong-Ki
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.45 no.6
    • /
    • pp.309-315
    • /
    • 2019
  • Objectives: The aim of this study was to evaluate the validity of the existing classification and difficulty index of impacted mandibular third molars in clinical situations and propose a more practical classification system. Materials and Methods: This study included 204 impacted mandibular third molars in 154 patients; panoramic x-ray images were obtained before tooth extraction. Factors including age, sex, and pattern of impaction were investigated. All impacted third molars were classified and scored for spatial relationship (1-5 points), depth (1-4 points), and ramus relationship (1-3 points). All variables were measured twice by the same observer at a minimum interval of one month. Finally, the difficulty index was defined based on the total points scored as slightly difficult (3-4 points), moderately difficult (5-7 points), very difficult (8-10 points), and extremely difficult (11-12 points). Results: The strength of agreement of the total points scored and difficulty index were 0.855 and 0.746, respectively. Most cases were classified as moderately difficult (73.0%). Although only 13 out of 204 cases (6.4%) were classified as extremely difficult, patients classified as extremely difficult were the oldest (P<0.05). Conclusion: For difficulty classification, the authors propose one more difficult category beyond the existing three-step difficulty index: the clinician should consider the patient's age in the difficulty index evaluation.

The effects of lumbar extensors strengthening program on low back muscle power and mass, pain, return to work of patients who took laser operation for herniated lumbar disc (요부신전강화 운동프로그램이 단순추간판탈출증 수술환자의 요부근육 및 통증 그리고 사회복귀에 미치는 영향)

  • Hwang, Seong-Soo;Kim, Myung-Joon
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.10 no.2
    • /
    • pp.45-56
    • /
    • 2004
  • OBJECTIVE: The objective of this study was to know the effects of the postoperative lumbar extensor strengthening exercise program on back muscles strength and volume, pain, and the time of return to work. METHODS: A prospective controlled trial of lumbar extensor exercise program in patients who underwent microdiscectomy or percutaneous endoscopic discectomy for prolapsed lumbar intervertebral disc. Seventy-five patients were randomized into exercise group (20 male, 15 female) and non-exercise group (18 male, 22 female). Six weeks after surgery, patients in exercise group undertook a 12-week lumbar extension exercise (MedX) program. Assessment of spinal function was performed in all patients on postoperative 6 weeks, 18 weeks. The assessment included measures of lumbar extensor power, muscle mass of erector spinalis. All patients completed the visual analog scale (VAS) for evaluation of pain, and return to work. RESULTS: In muscle power, there were statistically significant improvements between pre and post test on muscle power in exercise group. But there were not statistically significant difference on muscle power in non-exercise group. In muscle mass, there were statistically significant difference between pre and post test on muscle mass in exercise group. But there were not statistically significant difference on muscle mass in non-exercise group. In the pain, there were statistically significant decrease between pre and post test on both group. But there were not statistically significant difference on fatty tissue and obesity in non-exercise group. The percentages of return to work in postoperative 4 months were significantly greater in the exercise group than in the non -exercise group. CONCLUSIONS: Postoperative lumbar extensor strengthening exercise program appears to be more beneficial to the patients who underwent operation for prolapsed lumbar intervertbral disc.

  • PDF

Evaluation on Fatigue Behavior of EP(Engineering Plastic) Friction Pendulum Bearing System (EP가 적용된 마찰 진자형 지진격리받침의 피로거동분석)

  • Choi, Jung-Youl;Park, Hee-Soo;Chung, Jee-Seung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.6 no.4
    • /
    • pp.703-708
    • /
    • 2020
  • As the risk of earthquakes increases recently, earthquake-resistant designs were getting interest. For this reason, this study applies that Friction pendulum-type seismic isolator is a device that attenuates seismic energy by friction and pendulum motion. The friction pendulum-type seismic isolator of this study is very easy to transport, install and maintain with light weight of metal by applying the slider using high strength engineering plastic. In addition, there is an advantage that the corrosion resistance is very excellent compared to the existing metal parts. However, there is concern about long-term durability by replacing metal materials. In this study, the frictional pendulum-type seismic isolator with EP was applied to compressive-shear test, repeated fatigue test, and ultimate load test after fatigue test, and analyzed the deformation and shear or properties after the test. As the results, the adequacy of long term fatigue durability was experimentally proven.

Study on the Development of Home Care Nursing Intervention Protocol for Stroke Patients (뇌졸중 환자의 가정간호중재 프로토콜 개발)

  • Yoo Ji-Soo
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.7 no.1
    • /
    • pp.122-136
    • /
    • 2000
  • Stroke patient needs rehabilitation after receiving an acute treatment in a hospital. When stroke patient gets involved in an early discharge program, home care nurse plays a pivotal role to make them to gain a full strength and to come back to his/her prior life before he/she is sick. In spite of the importance of home care nursing intervention protocol for home care nurses to perform home care nursing autonomously, home care nursing intervention protocol for stroke patient is rarely developed. Therefore this study was conducted to develop home care nursing protocol that is applicable for stroke patients in home care nursing area. 41 home care nursing charts for stroke patients registered in home care nursing agencies from December 1st 1994 to August 31st 1999 at Y hospitals in Seoul and Won-Ju city were analyzed. 44 home care nurses who were having over three years' experience on stroke patients were participated in this study as a user validity validation group. The results of this study are as follows. 1. 28 nursing diagnoses were selected on the basis of evaluation of nursing diagnoses of stroke patients presented in a previous literature and case studies on home care nursing. 2. 17 nursing diagnoses were classified through the frequency analysis of home care nursing charts for 41 stroke patients who had received home care nursing. The order of sequence was like these: impaired skin integrity, risk for infection, nutritional deficit, impaired physical mobility, constipation, knowledge deficit, ineffective airway clearance, anxiety in family members, risk for aspiration, self care deficit, altered urinary elimination, ineffective individual coping, social isolation, risk for injury, self-esteem disturbance, impaired verbal communication, fatigue of family caregiver. 3. Based on validation on expert and user validities, 44 nursing interventions which were above ICV=.80 were chosen. 4. Nursing intervention protocols which showed above ICV=.90 were developed and were like these; pressure ulcer care, position change, preventive care for circulatory dysfunction, tube care : catheter, vital sign monitor, constipation/impaction management, artificial airway management, suction of airway secretion, environmental management : safety, and fall prevention.

  • PDF

A Study of Establishment of Softwaresystem Configuration for Improving Health Information Sharing (의료정보 공유기능 향상을 위한 소프트웨어시스템 기반구성 방법에 관한 연구)

  • Han, Soon-Hwa;Ju, Se-Jin
    • Journal of Digital Contents Society
    • /
    • v.15 no.1
    • /
    • pp.11-18
    • /
    • 2014
  • The strength of our country is based on high-speed networks to build a nationwide health information network to improve the quality of health care is needed. However, nature of the medical services in the hospital medical record form, so that all departments characterize each medical department, a common format that can be used for all disease is a very difficult challenge. This study is one of the ways to improve this priority issue on health information sharing medical information system(PACS/HIS) information linkage between the problem of information, compatibility and security issues derived. The problem is derived from the requirements of theorem 3 to 6 items. This is effective in order to improve sharing of medical information for the purpose of designing the software system. Sharing of medical information software system design are derived from stakeholders, requirements analysis, architecture design, software framework, configuration, architecture evaluation process. This study is based on the medical information standardization environmental diagnosis of a medical information system design. Software design philosophy is based on a new framework for deriving the function and mechanism made up.

Measurement System for Performance Evaluation of Acoustic Materials in a Small Water Tank (소형수조에서 음향재료의 반향음감소와 투과손실 측정시스템 구성)

  • Shin, Mi-Ru;Cho, Jung-Hong;Lee, Kyung-Teak;Kim, Jea-Soo;Jeon, Jae-Jin;Ham, Il-Bea;Kang, Chang-Gi
    • The Journal of the Acoustical Society of Korea
    • /
    • v.30 no.2
    • /
    • pp.63-72
    • /
    • 2011
  • Since the detection probability is critically dependent on the target strength (TS) in active sonar and on the radiated noise level (RNL) in passive sonar, the acoustic materials for echo reduction (ER) and transmission loss (TL) are widely used for the stealth of underwater targets. In this paper, a measurement system based on the small water tank, for the frequency range of greater than 30 kHz, is developed and verified using reference targets. In order to design the water tank and the geometry of test samples, a program is developed to calculate the arrival time of interfering signals due to the reflection from water tank walls and also due to the diffraction from the edge of the test samples. Considering all the interfering signals, an optimal experimental configuration for water tank and test samples is designed and used throughout the experiment. Next, the signal processing algorithms to estimate ER and TL are developed based on the measured propagation loss reflecting the geometric spreading characteristics of the transducer. Finally, a set of reference targets such as aluminium plate and perfectly reflecting plate are used in a small water tank to verify the developed measurement system.