• Title/Summary/Keyword: Strategy for storage

Search Result 409, Processing Time 0.024 seconds

A Study on the Economic Analysis for Installation Method of Storage Tank in LPG Filling Station (LPG 충전소 저장탱크의 설치방법에 따른 경제성 분석에 관한 연구)

  • Huh, Yong-Jeong;Lim, Ju-Yeon;Youm, Moo-Youl;Leem, Sa-Hwan
    • Journal of the Korean Institute of Gas
    • /
    • v.20 no.1
    • /
    • pp.23-28
    • /
    • 2016
  • "Eco-friendly" automobile has been a symbol of the Low Carbon, Green Growth strategy that Korea government decided to pursue. In line with the recent policy trend, a number of new LPG stations are being constructed. However, communities where mass storage are installed have been suffered from risk of serious accidents. In this work, economic analyses for different installation methods has been performed to prevent accidents in LPG filling station. The review shows that the underground storage is beneficial for the maintenance and the effective land use.

Li- and Na-ion Storage Performance of Natural Graphite via Simple Flotation Process

  • Laziz, Noureddine Ait;Abou-Rjeily, John;Darwiche, Ali;Toufaily, Joumana;Outzourhit, Abdelkader;Ghamouss, Fouad;Sougrati, Moulay Tahar
    • Journal of Electrochemical Science and Technology
    • /
    • v.9 no.4
    • /
    • pp.320-329
    • /
    • 2018
  • Natural graphite is obtained from an abandoned open-cast mine and purified by a simple, eco-friendly and affordable beneficiation process including ball milling and flotation process. Both raw graphite (55 wt %) and its concentrate (85 wt %) were electrochemically tested in order to evaluate these materials as anode materials for Li-ion and Na-ion batteries. It was found that both raw and purified graphites exhibit good electrochemical activities with respect to lithium and sodium ions through completely different reaction mechanisms. The encouraging results demonstrated in this work suggest that both raw and graphite concentrates after flotation could be used respectively for stationary and embedded applications. This strategy would help in developing local electrical storage systems with a significantly low environmental footprint.

Fabrication of Porous Electrodes for Zinc-Ion Supercapacitors with Improved Energy Storage Performance (아연-이온 전기화학 커패시터의 에너지 저장 성능향상을 위한 다공성 전극 제조)

  • An, Geon-Hyoung
    • Korean Journal of Materials Research
    • /
    • v.29 no.8
    • /
    • pp.505-510
    • /
    • 2019
  • Zn-ion supercapacitors (ZICs) show high energy densities with long cycling life for use in electronic devices. Porous Zn electrodes as anodes for ZICs are fabricated by chemical etching process using optimized conditions. The structures, morphologies, chemical bonding states, porous structure, and electrochemical behavior are examined. The optimized porous Zn electrode shows a root mean square of roughness of 173 nm and high surface area of $153{\mu}m^2$. As a result, ZIC using the optimized porous Zn electrode presents excellent electrochemical performance with high specific capacitance of $399F\;g^{-1}$ at current density of $0.5A\;g^{-1}$, high-rate performance ($79F\;g^{-1}$ at a current density of $10.0A\;g^{-1}$), and outstanding cycling stability (99 % after 1,500 cycles). The development of energy storage performance using synergistic effects of high roughness and high surface area is due to increased electroactive sites by surface functionalization of Zn electrode. Thus, our strategy will lead to a rational design and contribute to next-generation supercapacitors in the near future.

Identity-based Provable Data Possession for Multicloud Storage with Parallel Key-Insulation

  • Nithya, S. Mary V.;Rhymend Uthariaraj, V.
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.15 no.9
    • /
    • pp.3322-3347
    • /
    • 2021
  • Cloud Storage is the primary component of many businesses on cloud. Majority of the enterprises today are adopting a multicloud strategy to keep away from vendor lock-in and to optimize cost. Auditing schemes are used to ascertain the integrity of cloud data. Of these schemes, only the Provable Data Possession schemes (PDP) are resilient to key-exposure. These PDP schemes are devised using Public Key Infrastructure (PKI-) based cryptography, Identity-based cryptography, etc. PKI-based systems suffer from certificate-related communication/computational complexities. The Identity-based schemes deal with the exposure of only the auditing secret key (audit key). But with the exposure of both the audit key and the secret key used to update the audit key, the auditing process itself becomes a complete failure. So, an Identity-based PDP scheme with Parallel Key-Insulation is proposed for multiple cloud storage. It reduces the risk of exposure of both the audit key and the secret key used to update the audit key. It preserves the data privacy from the Third Party Auditor, secure against malicious Cloud Service Providers and facilitates batch auditing. The resilience to key-exposure is proved using the CDH assumption. Compared to the existing Identity-based multicloud schemes, it is efficient in integrity verification.

Research about Factor Affecting the Continuous Use of Cloud Storage Service : User Factor, System Factor, Psychological Switching Cost Factor (클라우드 스토리지 서비스의 지속적 사용의도에 영향을 미치는 요인 연구 : 사용자 요인, 시스템 요인, 심리적 전환비용)

  • Jun, Chang-Joong;Lee, Jung-Hoon;Jeon, In-Sook
    • The Journal of Society for e-Business Studies
    • /
    • v.19 no.1
    • /
    • pp.15-42
    • /
    • 2014
  • Cloud storage service has the potential to be a core infrastructure for the future mobile and Internet service; thus related service providers have been investing in it and trying to attract as many users as possible. In addition, those need to find out what motivates the users to keep using their service not only to attract new customers but also to secure their subscribers. Therefore, this study will examine its relationship with user's motivation based on the extended TAM model with external variables for objective research about continuous use of cloud storage service. As a result, it was found that personal innovativeness, self efficacy, functional attributes, and psychological switching cost influence the continuous use of cloud storage service. Also, it is expected they can guide service providers to the right track when setting up their business strategy in the future.

Advanced Fast-Forward/Backward Algorithm for VOD Server (VOD서버를 위한 개선된 Fast-Forward/Fast-Backward 알고리즘)

  • Jin-Uok Kim;Soo-Mok Jung
    • Journal of the Korea Computer Industry Society
    • /
    • v.5 no.2
    • /
    • pp.293-300
    • /
    • 2004
  • In this paper, we devise both methods supporting interactive VCR-like functions for MPEG stream and minimizing the storage space. Specifically, we proposed both methods to efficiently stripe MPEG stream into multiple disks, and an access strategy to retrieve the distributed streams over the disks. To accurately locate the streams to be referred to, we introduce a table indexing the location. When client request Fast Forward(FF)/Fast Backward(FB), VOD(Video on Demand) server refer to this index table supporting FF/FB functions. Experimental result shows that the proposed method can reduce the additional storage space needed when VOD server services FF/FB functions.

  • PDF

DC-Link Active Power Filter for High-Power Single-Phase PWM Converters

  • Li, Hongbo;Zhang, Kai;Zhao, Hui
    • Journal of Power Electronics
    • /
    • v.12 no.3
    • /
    • pp.458-467
    • /
    • 2012
  • Single phase converters suffer from ripple power pulsating at twice the line frequency. The ripple power is usually absorbed by a bulky capacitor bank and/or a dedicative LC resonant link, resulting in a low power density and a high cost. An alternative solution is using a dc link active power filter (APF) to direct the pulsating power into another energy-storage component. The main dc link filter capacitor can then be reduced substantially. Based on a mainstream dc APF topology, this paper proposed a new control strategy incorporating both dual-loop control and repetitive control. The circuit parameter design is also re-examined from a control point of view. The proposed APF scheme has better control performance, and is more suited for high power applications since it works in CCM and with a low switching frequency.

Control Strategy for Hybrid Module with Energy Storage for Island Mode (에너지 저장 장치를 갖는 태양광 하이브리드 모듈의 제어 전략)

  • Choi, Bong-Yeon;Jang, Jin-Woo;Lee, Soon-Ryung;Kim, Young-Ho;Won, Chung-Yuen
    • Proceedings of the KIPE Conference
    • /
    • 2013.07a
    • /
    • pp.477-478
    • /
    • 2013
  • This paper presents the control mehtod of a photovoltaic(PV) hybrid generation with energy storage system(ESS). To stabilize power control between PV generation system with ESS and local load, the proposed control method performs grid-connected and islanding operations. Through the simulation results the theoretical analysis of proposed method is verified.

  • PDF

Bi-Directional Multi-Level Converter for an Energy Storage System

  • Han, Sang-Hyup;Kim, Heung-Geun;Cha, Honnyong;Chun, Tae-Won;Nho, Eui-Cheol
    • Journal of Power Electronics
    • /
    • v.14 no.3
    • /
    • pp.499-506
    • /
    • 2014
  • This paper proposes a 3 kW single-phase bi-directional multi-level converter for energy storage applications. The proposed topology is based on the H-bridge structure with four switches connected to the DC-link. A simple phase opposition disposition PWM method that requires only one carrier signal is also suggested. The switching sequence to balance the capacitor voltage is considered. The topology can be extended to a nine-level converter or a three-phase system. The operating principle of the proposed converter is verified through a simulation and an experiment.

DC Microgrid Operational Method for Enhanced Service Reliability Using DC Bus Signaling

  • Hwang, Pyeong-Ik;Jang, Gilsoo;Pyo, Gi-Chan;Han, Byung-Moon;Moon, Seung-Il;Ahn, Seon-Ju
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.2
    • /
    • pp.452-464
    • /
    • 2015
  • This paper proposes a DC microgrid operational strategy and control method for improved service reliability. The objective is to supply power to as many non-critical loads as possible, while providing an uninterrupted power supply to critical loads. The DC bus signaling method, in which DC voltage is an information carrier, is employed to implement the operational strategy in a decentralized manner. During grid-connected operation, a grid-tied converter balances the power of the microgrid by controlling the DC voltage. All loads are connected to the microgrid, and operate normally. During islanded operation, distributed generators (DGs), a backup generator, or an energy storage system balances the power. However, some non-critical loads may be disconnected from the microgrid to ensure the uninterrupted power supply to critical loads. For enhanced service reliability, disconnected loads can be automatically reconnected if certain conditions are satisfied. Control rules are proposed for all devices, and detailed microgrid operational modes and transition conditions are then discussed. Additionally, methods to determine control parameter settings are proposed. PSCAD/EMTDC simulation results demonstrate the performance and effectiveness of the proposed operational strategy and control method.