• 제목/요약/키워드: Storage flux

검색결과 162건 처리시간 0.027초

누설자속 측정 시스템 개발을 위한 요소기술 (Core-Tcchnology for MFL Inspection System)

  • 원순호;조경식
    • 연구논문집
    • /
    • 통권30호
    • /
    • pp.159-168
    • /
    • 2000
  • In this research, MFL inspection system has been studied for the inspection of storage tank floor. The reference specimens having 20%, 40%, 60% and 80% slot's are fabricated using the carbon steel plates of a 6mm and 10mm thick. Powerful permanent magnets and Hall effect sensors are used to this application. Also, this paper presents a newly developed MFL scanning system. Conclusively, it is shown that our system is able to detect metal loss like a slot.

  • PDF

분할된 핀붙이 전열면상에서의 얼음의 용융 (Melting of ice on the heating plate with split fins)

  • 홍희기;김무근
    • 설비공학논문집
    • /
    • 제12권1호
    • /
    • pp.67-74
    • /
    • 2000
  • One of the important application of a contact melting process is a latent thermal energy storage owing to its high heat flux. In some previous works, the split fins have been employed in order to enhance the melting speed. In the present work, the close contact melting was experimentally investigated using an ice as specimen for both split and non-split fins. It was shown that the contact melting by split fins increases the melting rate compared to that of non-split ones.

  • PDF

아이스슬러리형 빙축열 시스템을 이용한 냉각 시스템의 성능에 관한 실험적 연구 (Characteristic Analysis of the Cooling System Using Ice Slurry Type Heat Storage System)

  • 이동원;김정배
    • 에너지공학
    • /
    • 제20권1호
    • /
    • pp.30-35
    • /
    • 2011
  • 2중관형과 판형 열교환기에 에틸렌 클리콜-물 수용액으로 만들어진 아이스슬러리를 적용하는 경우의 유동 및 열적 특성을 규명하기 위하여 실험을 수행하였다. 아이스슬러리의 질량유속과 얼음 분율은 각각 800에서 3500 kg/$m^2s$과 0에서 25%이었다. 실험을 통해, 압력강하와 열전달율은 질량유속과 얼음 분율에 따라 증가하였다. 그러나 얼음 분율의 효과는 높은 질량유속 영역에서는 크지 않은 것으로 나타났다. 낮은 질량유속에서는 압력강하와 열전달율의 급속한 증가가 질량 유속에 관계되는 것으로 나타났다.

Temperature change around a LNG storage predicted by a three-dimensional indirect BEM with a hybrid integration scheme

  • Shi, Jingyu;Shen, Baotang
    • Geosystem Engineering
    • /
    • 제21권6호
    • /
    • pp.309-317
    • /
    • 2018
  • We employ a three-dimensional indirect boundary element method (BEM) to simulate temperature change around an underground liquefied natural gas storage cavern. The indirect BEM (IBEM) uses fictitious heat source strength on boundary elements as basic variables which are solved from equations of boundary conditions and then used to compute the temperature change at other points in the considered problem domain. The IBEM requires evaluation of singular integration for temperature change due to heat conduction from a constant heat source on a planar (triangular) region. The singularity can be eliminated by a semi-analytical integration scheme. However, it is found that the semi-analytical integration scheme yields sharp temperature gradient for points close to vertices of triangle. This affects the accuracy of heat flux, if they are evaluated by finite difference method at these points. This difficulty can be overcome by a combination of using a direct numerical integration for these points and the semi-analytical scheme for other points distance away from the vertices. The IBEM and the hybrid integration scheme have been verified with an analytic solution and then used to the application of the underground storage.

곤지암 지하암반 저장고 온도계측 결과 분석 (Analysis of In-situ Temperature Measurement at Gonjiam Cold Storage Cavern)

  • 이규상;이정인
    • 터널과지하공간
    • /
    • 제15권3호
    • /
    • pp.169-176
    • /
    • 2005
  • 경기도 광주군에 건설된 상업적 규모의 지하암반 저장고인 '곤지암 지하암반 저장고' 에 대한 약 7년간 운영중에 측정된 결과를 분석하였다. 운영 초기 에 투입되었던 에너지와 저장고 주변의 온도가 안정화된 이후의 에너지를 비교하여 에너지 소비의 변화경향을 분석하였다. 초기 냉동기 설계에 필요한 용량과 저장고 운영에 필요한 냉동기 용량을 비교하여 초기 냉동시스템 설계 시 고려할 점에 대해 논하였다. 7년간 암반 내 지중온도 변화 양상을 분석하여, 암반 내 지하수가 동결될 때에 소요되는 추가적인 에너지에 대해 논하고, 현재 암반온도 분포 상황을 초기의 온도분포를 예측한 FLAC 수치해석 결과와 비교하였다. 냉동기 가동시간에 따른 투입된 열유량과, 2차원, 3차원 수치해석에 의한 열유량을 비교하여 수치해석에 의한 열유량 예측의 정확성에 대해 논하였다.

저장탱크 바닥면 검사를 위한 누설자속 탐상 시스템 개발 (Development of MFL Testing System for the Inspection of Storage Tank Floor)

  • 원순호;조경식;이종오;장홍근;주광태
    • 비파괴검사학회지
    • /
    • 제22권1호
    • /
    • pp.38-44
    • /
    • 2002
  • 누설자속법은 신뢰성과 경제성을 충족시키면서 정성적인 결과를 제공하는 비파괴시험법이다. 특히 저장탱크바닥판의 검사에 효과적으로 적용될 수 있음을 보여주었다. 이전에 저장탱크 qkekrvis의 검사에 사용되었던 초음파탐상법은 검사속도가 느리고, 적용에 따른 어려움으로 국부검사에 한정되어 왔다. 본 연구팀은 이러한 초음파탐상의 단점을 극복하고자 누설자속탐상법을 개발하였다. 개발된 시스템의 주요부분은 누설자속 발생부, 어레이센서, crawler 및 운용프로그램으로 구성되어 있고, 최종적으로 개발된 시스템이 6mm강판에서 ${\psi}3.2mm,\;d\;1.2mm$와 같은 인공결함을 검출할 수 있음을 보여주었다.

액화수소 저장탱크의 수평요동이 증발 특성에 미치는 영향에 대한 연구 (A Study on the Effect of Evaporation of Liquid Hydrogen Tank Related to Horizontal Sinewave)

  • 오승준;권준영;윤정환
    • 한국수소및신에너지학회논문집
    • /
    • 제34권2호
    • /
    • pp.155-161
    • /
    • 2023
  • Recently, a study on alternative and renewable energy is being conducted due to energy depletion and environmental problems. In particular, a hydrogen has the advantage of converting and storing the remaining energy into water-electrolyzed hydrogen through renewable energy generation. In general, due to reasons such as insulation problems, a study on high-pressure hydrogen storage tanks and related parts has recently been conducted. However, in the case of liquid hydrogen, the volume can be reduced by about 800 times or more compared to high-pressure hydrogen gas, so the study on this is needed as a technology that can increase energy density. In this study, the evaporation characteristics were analyzed under fixed heat flux conditions for liquid hydrogen storage tanks and the change in thermal stratification according to sloshing was analyzed. The heat flux condition was fixed at 250 W/m2 and the horizontal resonance frequency of the primary mode was applied to the storage tank. As a result, it was confirmed that the thermal stratification phenomenon decreased compared to the case where the slashing was not present due to forced convection when the slashing was present.

접지층에서 대기난류의 역할과 에너지 평형 (Role of Atmospheric Turbulences and Energy Balances in the Atmospheric Surface Layer)

  • 권병혁;김근희;김광호;강동환
    • 한국습지학회지
    • /
    • 제11권1호
    • /
    • pp.105-113
    • /
    • 2009
  • 연안습지 생태계에서 열에너지 교환 과정은 매우 중요하다. 지표 열에너지 평형을 이루는 요소인 순복사플럭스, 현열 플럭스, 잠열 플럭스 그리고 토양열 플럭스를 전라남도 고흥에 위치한 수평적으로 균질하다고 판단되는 지역인 고흥만 간척지에서 관측하고 분석하였다. 열의 수송을 평가하기 위해서 5회의 집중관측 기간에 대기 난류를 측정하였고, 특히 갈대로 덮여있는 간척지에서 지표층 열에너지 수지를 분석하기 위해서는 물과 매우 미세한 입자로 구성된 토양 그리고 계절에 따라 색깔과 밀도가 변하는 식생캐노피를 고려하였다. 순복사 플럭스, 현열 플럭스, 잠열 플럭스, 토양열 플럭스를 기존의 에너지 수지방정식에 적용하여 식생과 토양과 같은 지표면 특성에 따른 열 플럭스의 특징을 조사하여 습지의 기온조절 효과에 대해 알아보았다. 에너지 수지비로 식생 성장기에는 주로 잠열 플럭스에 의해 열이 대기로 전달되는 것을 알 수 있었다. 또한 식생층은 열을 저장하여 기온의 일교차를 줄이는 역할을 한다. 여름철에 집중관측지의 기온이 주변 지역의 기온보다 보다 낮고 겨울철에는 다소높게 나타난 결과는 식생층을 포함하는 연안습지가 열환경을 조절함을 보여주었다.

  • PDF

Design and Analysis of a Material Efficient Sinusoidal Consequent-Pole High-Speed Axial-Flux Machine

  • Kumar, Sunil;Kwon, Byung-il
    • 전기전자학회논문지
    • /
    • 제22권3호
    • /
    • pp.759-766
    • /
    • 2018
  • This paper presents a high-speed axial-flux machine which utilizes the idea of sinusoidal shaped pole combined with a consequent iron-pole. The target of the proposed machine is the cost reduction of the relatively expensive Samarium-Cobalt (SmCo) permanent magnet (PM) material and the torque per PM volume improvement by using sinusoidal consequent-pole rotor. The effectiveness of the proposed machine is validated by comparing it with conventional consequent-pole and with conventional PM machines using 3-D finite element method (FEM) simulations. The comparison and analysis is done in terms of back electro-motive force (back-EMF) harmonic contents, torque per PM volume and torque ripple characteristics. The simulation results show that the proposed machine is suitable and cost-effective for high-speed and high torque per PM volume applications. Furthermore, due to the consequent pole, the magnetic flux saturation and the overload current torque-capability are also presented and discussed in the paper.

침엽수림에서 토양열 플럭스의 공간 변화 (Spatial Variability of Soil Heat Fluxes in a Conifer Forest)

  • Yun-Ho Park;Byong-Lyol Lee;Kyung-Sook Cho
    • 한국농림기상학회지
    • /
    • 제5권2호
    • /
    • pp.81-86
    • /
    • 2003
  • 침엽수림에서 토양열 플럭스의 공간변화를 미기상 관측을 통해 조사하였다. 일평균 최대 하향단파복사(R $s_{dn}$ )와 순복사 (Rn)는 약 260W $m^{-2}$ 와 180 W $m^{-2}$ 였다. 7월 중순에서 8월 중순 사이의 일평균 토양열 플럭스는 대체로 순복사의 10% 였다. 연구기간동안 측정된 토양열 플럭스 ( $G_{6}$)와 계산된 토양열 플럭스 (G)와의 오차는 2% 이내였다. 열 저류항에 의한 최대 플럭스의 지연이 관측되었다. 이러한 열 저류항을 고려하지 않을 경우, 약 10에서 15W $m^{-2}$ 의 오차가 발생 할 수 있다.