Browse > Article

Analysis of In-situ Temperature Measurement at Gonjiam Cold Storage Cavern  

Lee Gyu-Sang (농업기반공사, 농어촌연구원 수리시험연구실)
Lee Chung-In (서울대학교 지구환경시스템공학부)
Publication Information
Tunnel and Underground Space / v.15, no.3, 2005 , pp. 169-176 More about this Journal
Abstract
The decreasing pattern of underground temperature measured at 'Gonjiam cold storage cavern' during 7 years which was the first commercial scale underground food storage cavern in Korea was analyzed. The variation of energy consumption was discussed by comparing the consumed energy at the initial operation stage with that at later stage, when the temperature distribution reached a stabilized condition. The point to be considered at the design stage was also discussed by comparing the required refrigerator capacity at the initial operation stage with that at later stage. The extra energy to freeze the groundwater contained in pore space was discussed by analyzing the changing pattern of the rock temperature. The variation of measured rock temperature was compared with the estimated temperature using a numerical code, FLAC. The accuracy of the numerical estimation was discussed by comparing the heat flux measured by the operation time of the refrigerator with that estimated numerically.
Keywords
temperature distribution heat; flux; FLAC; freezing storage; latent heat of freezing;
Citations & Related Records
연도 인용수 순위
  • Reference
1 농업기반공사, 2003, 곤지암 지하저장 터미널 운영백서
2 이규상, 이정인, 2004, 지하암반 냉동저장고 주변의 온도분포 예측을 위한 수치해석, 터널과 지하공간 14, 287-294
3 원성필, 2003, 냉동공학, 보성간, 91-142
4 안대영, 1994, 농수축산물 지하저장시설 형태별 경제성 비교와 실례, 곡물엘리베이터와 농수축산물 지하암반 저장시설 특별 심포지엄 자료집, 농어촌진흥공사, 173-195
5 냉동물제조수산업현동조합, 1994, 냉동식품의 이론과 실제, 유림문화사, 448-455
6 신중호, 박연준, 김호영, 박찬, 1999, 아치형 냉동저장공동주의 암반의 열전도 특성 및 열물성 평가, 터널과 지하공간, 9, 27-35