• Title/Summary/Keyword: Square-wave voltammetry

Search Result 75, Processing Time 0.047 seconds

Detection of chlorine in tap water using a metal gold electrode (금속 Au 전극을 이용한 먹는 물 속 염소 이온 검출)

  • Ly, Suw-Young;Choa, Sung-Hoon
    • Analytical Science and Technology
    • /
    • v.24 no.3
    • /
    • pp.219-224
    • /
    • 2011
  • Voltammetric analysis of Cl(I) ion was performed using a metal gold (Au) electrode (AE) and a carbon nanotube electrode (CNTE). After the examination, the AE was found to have more sensitively detected Cl(I) than CNTE. The optimum analytical conditions for the cyclic voltammetry (CV) and the square wave (SW) stripping voltammetry were performed using AE. The detection limit of $6.5\;{\mu}g/L$ Cl(I) was attained. The developed techniques were compared with the common Cl meter and applied to water systems.

Bismuth Coated Carbon Fiber Microelectrode with Gallic Acid n-Propyl Ester for Trace Copper Analysis (비스무스코팅 탄소섬유전극과 갤릭산 착물을 사용한 구리 이온의 흔적량 분석)

  • Ly, Suw-Young;Lee, Chang-Hyun;Jung, Young-Sam
    • Journal of Environmental Science International
    • /
    • v.16 no.10
    • /
    • pp.1111-1118
    • /
    • 2007
  • A bismuth-coated carbon fiber microelectrode was prepared using cyclic voltammetry (CV). An analytical application was performed for the copper analysis with Square Wave Stripping Voltammetry (SWSV). Gallic acid n-propyl ester (PG) was used for the complex formation with a copper ion, and electrochemical measurements were performed with a pre-amplifier of a low-current module for nano am per detection. The effects of various parameters on the response were optimized. Analytical working ranges of $0.03-25.9\;{\mu}gl^{-1}$ and $0-25\'mgl^{-1}$ Cu(II) were obtained. The relative standard deviation at $13\;mgl^{-1}$ Cu was 0.9% (n = 12) in optimum conditions. The detection limit was found to have been $0.019\;{\mu}gl^{-1}$, with a 30-sec accumulation time. The developed methods were applied to a copper assay in water samples.

Determination of Heavy Metals in Sea Salt Using Anodic Stripping Voltammetry

  • Kim, Yong Hoon;Kim, Giyoung
    • Food Engineering Progress
    • /
    • v.21 no.2
    • /
    • pp.180-186
    • /
    • 2017
  • Salt, as food, is the most essential element for human survival due to its significant physiological functions. Here, we report the simultaneous detection of Pb and Cd in sea salt by square wave anodic stripping voltammetry (SWASV). Stripping voltammetric measurements were conducted using a manufactured rotating disk electrode system (MRDES). The detection limit was $3.6{\pm}0.18{\mu}gL^{-1}$ for Pb and $3.9{\pm}0.37{\mu}gL^{-1}$ Cd in NaCl solution. When the pH increased from 5.5 to 8.5, the peak currents of Pb and Cd decreased. At a pH of 8.3, the ratio of the current drop compared with that at a pH of 5.5 was 0.6 for Pb and 0.73 for Cd. The concentrations corrected by the current drop are in agreement with the concentrations obtained with ICP (inductively coupled plasma). This system demonstrates the reliable detection of heavy metals in aqueous media and, at a high $Na^+$ concentration, the successful application for the determination of Pb and Cd in sea salts.

Study on Electrode Selection for Electrochemical Detection of Cadmium and Lead (카드뮴과 납 전기화학적 검출을 위한 전극선정에 관한 연구)

  • Kim, Hak-Jin;Kim, Ki-Young;Moh, Chang-Yeon;Cho, Han-Keun
    • Journal of Biosystems Engineering
    • /
    • v.33 no.6
    • /
    • pp.404-409
    • /
    • 2008
  • Excessive presence of heavy metals in environment affects plants and fruits grown in the contaminated area. Rapid on-site monitoring of heavy metals can provide useful information for efficiently characterizing heavy metal-contaminated sites and for minimizing the exposure of the contaminated food crops to humans. This study reports on the evaluation of gold and glassy carbon (GC) electrodes with mercury or bismuth as a coating material for simultaneous determination of cadmium (Cd) and lead (Pb) in 0.1 M $HNO_3$ solution by anodic stripping voltammetry (ASV). The use of a square-wave voltammetric potential between a working electrode and a reference electrode caused Cd and Pb ions deposited on the electrode surface to be oxidized, thereby generating electric currents at different potentials. The mercury-coated gold electrode was not sensitive enough to detect the usable range of Cd concentrations (1 to 100 ppb). The GC electrodes with mercury or bismuth displayed well-defined, sharp and separate current peaks for Cd and Pb ions when the square-wave voltammetric potentials were applied. The peak currents measured with both mercury- and bismuth- coated GC electrodes were linearly proportional to Cd and Pb concentrations in the range of 1 to 200 ppb in 0.1 M $HNO_3$ with strong linear relationships between concentration and peak current ($R^2$ > 0.95), indicating that both of Cd and Pb ions could be quantitatively measured.

A Study on Detection Characteristics of Cadmium and Lead for Bi Nanopowder-Labeled Electrode (비스무스 나노분말 표지 전극의 카드뮴/납 검출특성에 관한 연구)

  • Lee, Gyeoung-Ja;Kim, Hyoun-Jin;Lee, Hi-Min;Lee, Sang-Hoon;Lee, Min-Ku;Lee, Chang-Kyu
    • Journal of Powder Materials
    • /
    • v.15 no.5
    • /
    • pp.393-398
    • /
    • 2008
  • Trace analysis of Cd and Pb at surface modified thick film graphite electrode with Bi nanopowder has been carried out using square-wave anodic stripping voltammetry (SWASV) technique. Bi nanopowder synthesized by gas condensation (GC) method showed the size of $50{\sim}100$ nm with BET surface area, $A_{BET}=6.8m^{2}g^{-l}$. For a strong adhesion of the Bi nanopowder onto the screen printed carbon paste electrode, nafion solution was added into Bi-containing suspension. From the SWASV, it was found that the Bi nanopowder electrode exhibited a well-defined responses relating to the oxidations of Cd and Pb. The current peak intensity increased with increasing concentration of Cd and Pb. From the linear relationship between Cd/Pb concentrations and peak current, the sensitivity of the Bi nanopowder electrode was quantitatively estimated. The detection limit of the electrode was estimated to be $0.15{\mu}g/l$ and $0.07{\mu}g/l$ for Cd and Pb, respectively, on the basis of the signal-to-noise characteristics (S/N=3) of the response for the $1.0{\mu}g/l$ solution under a 10 min accumulation.

Determination of Trace Level Mercury in Bio-Materials by Square Wave Anodic Stripping Voltammetry (네모파 산화전극벗김 전압전류법을 이용한 생체시료 중의 미량 수은 분석)

  • Kim Il Kwang;Park Sung Woo;Han Jong Hyun;Kim Youn Geun;Chun Hyun Ja;Park Kyung Ok
    • Journal of the Korean Chemical Society
    • /
    • v.37 no.5
    • /
    • pp.477-482
    • /
    • 1993
  • The determination of trace level mercury in bio-materials has been investigated by the square wave anodic stripping voltammetry (ASV)-technique at glassy carbon electrode. Prior to analysis, the bio-materials were digested with HNO3/H2SO4 mixture and KMnO4 was added to complete the oxidation. The detection limit of the mercury varied greatly with deposition time, deposition potential, pH and stirring rate. When deposition is carried out for 240 sec with 400 rpm stirring at -1.0 volts vs. Ag/AgCl, the detection limit was below $0.5\;ppb\;(2.5{\times}10^{-9} M)$. The method is recommended for trace level mercury analysis of biomaterials because this procedure is time saving and has higher sensitivity.

  • PDF

Determination of Bio-Accumulated Trace Mercury by Anodic Stripping Square Wave Voltammetry at Glassy Carbon Electrode (유리질 탄소전극에서 양극벗김 네모파 전압-전류법에 의한 생체내 미량 수은의 정량)

  • Kim, Il Kwang;Chun, Hyun Ja;Jeong, Seung Il;Beck, Seung Hwa;Han, Wan Soo
    • Journal of the Korean Chemical Society
    • /
    • v.45 no.4
    • /
    • pp.298-303
    • /
    • 2001
  • The trace-level mercury in bio-materials has been determinated by the anodic stripping square wave voltammetry (ASSWV)-technique at glassy carbon electrode. Prior to the analysis, the bio-materials were digested with $HNO_3/H_2SO_4$ mixture and KMnO4 was added to complete an oxidation process of the mixture. The detection limit of the mercury varied greatly with deposition time, deposition potential, pH and stirring rate. When the deposition was carried out for 240 sec on 400 rpm stirring at -1.0 volts vs. Ag/AgCl, the detection limit was below 0.5 ppb ($2.5{\times}10^{-9}M$). The accumulated mercury was high in the kidney and liver, and low in the brain according to the determination of mercury accumulation for a white rat by this method.

  • PDF

Determination of Trace Level Germanium(IV) by Square Wave Anodic Stripping Voltammetry (네모파 산화전극 벗김 전압전류법을 이용한 게르마늄의 미량분석)

  • Il Kwang Kim;Hyun Ja Chun;Seung Il Jeong;Sung Woo Park;Jae Hoon You
    • Journal of the Korean Chemical Society
    • /
    • v.37 no.11
    • /
    • pp.943-950
    • /
    • 1993
  • The determination of trace level germanium in 5.0 ${\times}\;10^{-2}$ M perchloric acid supporting electrolyte solution containing 8.0 ${\times}\;10^{-2}$ M catechol has been investigated by the square wave anodic stripping voltammetry. The optimum conditions in determination of germanium were as follows: deposition time; 120 sec, deposition potential; -0.9 volts vs. Ag/AgCl and frequency; 100 Hz. The determination of germanium was possible regardless of coexistent ion such as copper, lead and silicon. Calibration curve was shown a good linearlity in the range of 0.40 ppb to 2.0 ppm and the detection limit was 0.080 ppb. This method was useful for trace level germanium due to the short analysis time and higher sensitivity.

  • PDF

Quantitative Analysis of Skin Lotion Containing Rutin by Voltammetric Method Using Graphite Electrode (흑연전극을 사용한 전압전류법을 이용하여 스킨로션 중 루틴성분의 정량분석)

  • Kang, Myung-Kyu;Won, Bo-Ryoung;Lee, Dong-Kuk;Ly, Suw-Young;Park, Soo-Nam
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.35 no.4
    • /
    • pp.325-331
    • /
    • 2009
  • We studied square-wave stripping voltammetry (SWV) to analyze quantitatively rutin contained in transparent skin-lotion using graphite electrode. The optimum analytical conditions for quantitative analysis of rutin were determined and the linear range was obtained of $1\;{\sim}\;8\;{\mu}g/mL$. The relative standard deviation of fifteen times repetition measurement for $0.1\;{\mu}g/mL$ of rutin was 0.080 and the detection limit was $0.01\;{\mu}g/mL$, respectively. We considered that this study could be used for quantitative analysis of active components contained in cosmetics.

Analysis of Lead Ions in a Waste Solution Using Infrared Photo-Diode Electrode

  • Ly, Suw-Young;Lee, Hyun-Kuy;Kwak, Kyu-Ju;Ko, Jun-Seok;Lee, Jeong-Jae;Cho, Jin-Hee;Kim, Ki-Hong;Kim, Min-Seok;Lee, So-Jung
    • Toxicological Research
    • /
    • v.24 no.3
    • /
    • pp.227-233
    • /
    • 2008
  • To detect lead ions using electrochemical voltammetric analysis, Infrared Photo-Diode Electrode(IPDE) was applied via cyclic and square wave stripping voltammetry. Lead ions were deposited at 0.5 V(versus Ag/AgCl) accumulation potential. Instrumental measurements systems were made based on a simple and compact detection system. The stripping voltammetric and cyclic voltammetric optimal parameters were searched. The results yielded a cyclic range of $40{\sim}240mgl^{-1}$ Pb(II) and a square wave stripping working range of $0.5{\sim}5.00mgl^{-1}$ Pb(II). The relative standard deviation at 2 and 4 $mgl^{-1}$ Pb(II) was 0.04% and 0.02%(n=15), respectively, using the stripping voltammetric conditions. The detection limit was found to be 0.05 $mgl^{-1}$ with a 40 sec preconcentration time. Analytical interference ions were also evaluated. The proposed method was applied to determine lead ions in various samples.