Browse > Article
http://dx.doi.org/10.5307/JBE.2008.33.6.404

Study on Electrode Selection for Electrochemical Detection of Cadmium and Lead  

Kim, Hak-Jin (School of Biosystems Engineering, Pusan National University)
Kim, Ki-Young (National Academy of Agricultural Science)
Moh, Chang-Yeon (National Academy of Agricultural Science)
Cho, Han-Keun (Department of Biosystems Engineering, Chungbuk National University)
Publication Information
Journal of Biosystems Engineering / v.33, no.6, 2008 , pp. 404-409 More about this Journal
Abstract
Excessive presence of heavy metals in environment affects plants and fruits grown in the contaminated area. Rapid on-site monitoring of heavy metals can provide useful information for efficiently characterizing heavy metal-contaminated sites and for minimizing the exposure of the contaminated food crops to humans. This study reports on the evaluation of gold and glassy carbon (GC) electrodes with mercury or bismuth as a coating material for simultaneous determination of cadmium (Cd) and lead (Pb) in 0.1 M $HNO_3$ solution by anodic stripping voltammetry (ASV). The use of a square-wave voltammetric potential between a working electrode and a reference electrode caused Cd and Pb ions deposited on the electrode surface to be oxidized, thereby generating electric currents at different potentials. The mercury-coated gold electrode was not sensitive enough to detect the usable range of Cd concentrations (1 to 100 ppb). The GC electrodes with mercury or bismuth displayed well-defined, sharp and separate current peaks for Cd and Pb ions when the square-wave voltammetric potentials were applied. The peak currents measured with both mercury- and bismuth- coated GC electrodes were linearly proportional to Cd and Pb concentrations in the range of 1 to 200 ppb in 0.1 M $HNO_3$ with strong linear relationships between concentration and peak current ($R^2$ > 0.95), indicating that both of Cd and Pb ions could be quantitatively measured.
Keywords
Cadmium; Lead; Anodic Stripping Voltammetry (ASV); Bismuth; Glassy carbon electrode;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Cooper, J., J. A. Bolbot, S. Saini and S. J. Setford. 2007. Electrochemical method for the rapid on site screening of cadmium and lead in soil and water samples. Water Air Pollut. 179:183-195   DOI
2 Jung, M. C. 2001. Heavy metal contamination of soils and waters in and around the Imcheon Au-Ag mine, Korea. Appl. Geochem. 16(11-12):1369-1375   DOI   ScienceOn
3 Kachoosangi, R. T., C. E. Banks, X. Ji and R. G. Compton. 2007. Electroanalytical determination of cadmium (II) and lead (II) using an in-situ bismuth film modified edge plane pyrolytic graphite electrode. Anal. Sci. 23:283-289   DOI   ScienceOn
4 Banks, C. E., M. E. Hyde, P. Tomcik, R. Jacobs and R. G. Compton. 2004. Cadmium detection via boron-doped diamond electrodes: surfactant inhibited stripping voltammetry. Talanta 62:279-286   DOI   ScienceOn
5 Wan Ngah, W. S. and M. A. K. M. Hanafiah. 2008. Removal of heavy metal ions from wastewater by chemically modified plant wastes as adsorbents: A review. Bioresource Technol. 99(10):3935-3948   DOI   ScienceOn
6 Wang, J., J. Lu, S. B. Hocevar and P. A. M. Farias. 2000. Bismuth-coated carbon electrodes for anodic stripping voltammetry. Anal. Chem. 72:3218-3222   DOI   ScienceOn
7 Hanrahan, G., D. G. Patil and J. Wang. 2004. Electrochemical sensors for environmental monitoring: design, development and applications. J. Environ. Monit. 6(8):657-664   DOI   ScienceOn
8 Kim, H. J., J. W. Hummel, K. A. Sudduth, and P. P. Motavalli. 2007. Simultaneous analysis of soil macronutrients using ion-selective electrodes. Soil Sci. Soc. Am. J. 71(6):1867-1877   DOI   ScienceOn
9 McGaw, E. A. and G. M. Swain. 2006. A comparison of boron-doped diamond thin-film and Hg-coated glassy carbon electrodes for anodic stripping voltammetric determination of heavy metals in aqueous media. Anal. Chim. Acta 575:180-189   DOI   ScienceOn