• Title/Summary/Keyword: Speed up test

Search Result 707, Processing Time 0.054 seconds

Analysis of time-saving effects on increasing the speed through the trial run test in Gyeongbu line (틸팅시제열차 경부선 증속시험운행을 통한 시간단축효과분석)

  • Han, Seong-Ho;Lee, Su-Gil
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.1935-1942
    • /
    • 2011
  • We have tested the developed Korean tilting train in main exisiting commercial line for speed-up on cuve section to achive reduction effects of running time. We have conducted a trial run test to speed-up 30km/h on curves in Gyeongbu line successfully. Normal current train have been operated 110km/h in 600m radius. Yet, tilting train was tested 135km/h(maximum operation line speed) in same sections. We confirmed that the dynamic runing stability of train was safety by regarding wheel load and lateral force.

  • PDF

A Study on Engine Valve and Seat Insert Wearing Depending on Speed Change (속도변화에 따른 엔진 밸브 및 시트 인서트의 마모에 관한 연구)

  • 전경진;홍재수
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.11 no.6
    • /
    • pp.14-20
    • /
    • 2003
  • The minimization of valve and seat insert wear is a critical factor in the pursuit of engine performance improvement. In order to achieve this goal, we have developed a new simulator, which can generate and control high temperatures up to $900^{\circ}C$ and various speeds up to 80Hz during motion, just like an actual engine. The wear simulator is considered to be a valid simulation of the engine valve and seat insert wear process with various speeds during engine activity. The objective of this work focuses on the different degrees of wear from two different test speeds (10Hz & 25Hz). For this study, the temperature of the outer surface of the seat insert was controlled at $350^{\circ}C$, the cycle number was 2.1$\times$106, and the test load was 1960N. The wear depth and surface roughness were measured before and after the testing using a confocal laser scanner. It was found that a higher speed (25Hz) causes more wear than a lower speed (10Hz) under identical test conditions (temperature, cycle number and test load). In the wear mechanism adhesive wear, shear strain and abrasive wear could be observed.

Application of a standardized exercise test by measuring serum lactate concentration in Thoroughbred racehorses (더러브렛 경주마에서 혈청 젖산농도 측정에 의한 표준운동능력검사의 적용)

  • Mun, Kyu-whan;Kim, Joon-gyu;Kim, Byung-sun;Um, Young-ho;Yang, Il-suk
    • Korean Journal of Veterinary Research
    • /
    • v.39 no.6
    • /
    • pp.1081-1090
    • /
    • 1999
  • To establish the protocol of a standardized exercise test for evaluating exercise intolerance and degree of fitness in Thoroughbred racehorses, we examined serum lactate concentrations related to exercise intensities using the high speed treadmill. Twelve clinically healthy Thoroughbred racehorses with or without previous training or racing history were assigned to two gorups, fit and unfit group, respectively. The protocol used for the standardized exercise test was consisted of two stages : stage of warm-up and that of acceleration. During the warm-up, the horses exercised 5 min at 1.8m/s and 3 min 3.4m/s without inclination. At the acceleration stage, exercise test was performed at 10% slope and the speed was increased from the initial 5m/s to the maximal speed which each tested horse could keep up with. The speed was increased with incremental steps of 1 m/s every minute. During the last 15 sec of each step, blood samples were collected for serum lactate determination. $V_{max}$(maximal treadmill speed which tested horses could keep up with) of the fit group ($10.93{\pm}0.33m/s$, mean${\pm}$SE, n = 6) was higher than that of the unfit group ($9.52{\pm}0.23m/s$, mean${\pm}$SE, n = 6). Serum lactate concentrations increased exponentially according to exercise intensities. $V_{La4}$(speed producing a serum lactate concentration of 4mmol/l) of the fit group, $6.45{\pm}0.26m/s$, was higher than that of the unfit group, $5.45{\pm}0.23m/s$. $La_{peak}$(peak plasma lactate concentration during the exercise test) was lower in the fit group ($20.34{\pm}1.62mmol/l$ at 1 min after maximal intensity exercise) than in the unfit group ($24.78{\pm}1.09mmol/l$ at 2 min after maximal exercise step). $t_{50%}$(time required for the recovery of lactate concentration to be one-half of $La_{peak}$ after maximal exercise) of the unfit group and the fit group were 40.0 and 18.0 min, respectively. Therefore, the protocol of the incremental standardized exercise test utilized in this study seems to be reliable for the assessment of fitness and exercise intolerance for the Thoroughbred racehorses.

  • PDF

The study of a primary role of Back up Breaker and Making Switch for Short Circuit Test (단락시험에서 후비보호차단기와 투입스위치의 중요 역할)

  • Kim, Sun-Koo;Kim, Seon-Ho;Kim, Won-Man;Roh, Chang-Il;Lee, Dong-Jun;Jung, Heung-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.915-916
    • /
    • 2007
  • There are many equipments for the Short Circuit Test, for example Short Circuit Generator, Induction Motor, Sequence Timer, Exciter, CLR, Back Up Breaker, Making Switch and TRV etc. Especially Back up Breaker and Making Switch are very important equipments to test the short circuit test. A role of a Back up Breaker is to break high-voltage and high-current for short circuit test and a Making Switch should be operated always same speed/time and kept electrical-mechanical characteristics to make the voltage and current of short circuit test. This study introduces to the short circuit test also to kinds, principal movements and compare them of Back up Breaker and Making Switch.

  • PDF

A Development of Pulley-type Tensioning Device for a High Speed Railway (고속용 풀리형식 장력조정장치 개발)

  • Cho, Yong-Hyeon;Kwon, Sam-Young;Park, Young;Lee, Ki-Won
    • Proceedings of the KSR Conference
    • /
    • 2006.11b
    • /
    • pp.723-730
    • /
    • 2006
  • In the electrical railway, the tension ascension of contact wire is essential to speed up of train and current collection performance of catenary largely depends on the tension. The tension variation rate of the tensioning device used in existing line limits within 5%, and the tension variation rate of the spring-type tensioning device installed at the section where tensioning length is short bounds within 15%. So it is urgent for us to localize it for high speed line, which the tension variation rate is limited within 3%. Therefore in this study, a pulley-type tensioning device for high speed line is developed. To verify the performance of developed device, a performance test, overload test and failure test is carried out under the code of the Kyung-Bu High Speed line. And it is secured durability performance through a fatigue test.

  • PDF

고속철도 교량 신축이음장치의 내구성 실험

  • 김병석;곽종원;신호상;김영진;박성용;장익순
    • Proceedings of the KSR Conference
    • /
    • 1998.11a
    • /
    • pp.24-29
    • /
    • 1998
  • To absorb the deformation of ,external live load, thermal gradient, shrinkage and creep in bridge structures and general structures, expansion joint has to be established. Especially expansion joint for high-speed railway bridge has to accomodate the static and dynamic forces and it not only has the durability of itself but also maintain the durability of structure by preventing the leakage of water. The actual used product of expansion joint for high-speed railway bridge is only ones made in France, Germany and Japan. In this study, the development process and test results of developed expansion joint are introduced which has the functional operation and durability enough to apply to high-speed railway bridges, roadway bridges and general structures. The tests consist of fatigue-durability test of 3 million times by high-speed rail load, leakage test and jack-up test for verifying the possibility of exchanging it. The performance of developed expansion joint satisfy the specification of Korea High Speed Rail Construction Authority.

  • PDF

Effect of Shearing Speed on High Speed Shear Properties of Sn1.0Ag0.5Cu Solder Bump on Various UBM's (다양한 UBM층상의 Sn0Ag0.5Cu 솔더 범프의 고속 전단특성에 미치는 전단속도의 영향)

  • Lee, Wang-Gu;Jung, Jae Pil
    • Korean Journal of Metals and Materials
    • /
    • v.49 no.3
    • /
    • pp.237-242
    • /
    • 2011
  • The effect of shearing speed on the shear force and energy of Sn-0Ag-0.5Cu solder ball was investigated. Various UBM (under bump metallurgy)'s on Cu pads were used such as ENEPIG (Electroless Nickel, Electroless Palladium, Immersion Gold; Ni/Pd/Au), ENIG (Electroless Nickel, Immersion Gold; Ni/Au), OSP (Organic Solderability Preservative). To fabricate a shear test specimen, a solder ball, $300{\mu}m$ in diameter, was soldered on a pad of FR4 PCB (printed circuit board) by a reflow soldering machine at $245^{\circ}C$. The solder bump on the PCB was shear tested by changing the shearing speed from 0.01 m/s to 3.0 m/s. As experimental results, the shear force increased with a shearing speed of up to 0.6 m/s for the ENIG and the OSP pads, and up to 0 m/s for the ENEPIG pad. The shear energy increased with a shearing speed up to 0.3 m/s for the ENIG and the OSP pads, and up to 0.6 m/s for the ENEPIG pad. With a high shear speed of over 0 m/s, the ENEPIG showed a higher shear force and energy than those of the ENIG and OSP. The fracture surfaces of the shear tested specimens were analyzed, and the fracture modes were found to have closer relationship with the shear energy than the shear force.

Research on Configuration Optimization of Overlap Section in Overhead Catenary System for High-speed Railway (전차선로 속도향상에 따른 오버랩 구간(Overlap section) 경간 구성 기법)

  • Choi, Tae-su;Choi, Kyu-Hyoung
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.6
    • /
    • pp.975-980
    • /
    • 2017
  • Overhead catenary system of electric railway has overlap sections which devide and tighten trolley wire supplying electric power to train, where current collection performances may become worse according to railway speed-up. Current collection tests conducted at 400 km/h test-bed section of Honam high-speed railway show that balanced line arrangement at overlap section is needed to secure current collection without arc generation between trolley wire and train current collection device. This paper proposes a design procedure of the overlap section to allow for tension increase and uplift of the trolley wires according to railway speed-up. By applying the proposed procedure to the overhead catenary system of Honam high-speed railway, it is suggested that the minimum span length should be 33.2 m for railway speed-up to 350 km/h and 43.7 m for speed-up to 400 km/h.

Technique of Measuring Wind Speed and Direction by Using a Roll-rotating Three-Axis Ultrasonic Anemometer (II) (롤 회전하는 3축 초음파 풍속계를 활용한 풍향 풍속 측정기법(II))

  • Chang, Byeong Hee;Lee, Seunghoon;Kim, Yang won
    • Journal of Wind Energy
    • /
    • v.9 no.4
    • /
    • pp.9-15
    • /
    • 2018
  • In a previous study, a technique for measuring wind speed and direction by using a roll-rotating three-axis ultrasonic anemometer was proposed and verified by wind tunnel tests. In the tests, instead of a roll sensor, roll angle was trimmed to make no up flow in the transformed wind speeds. Verification was done in point of the residual error of the rotation effect treatment. In this study, roll angle was measured from the roll motor encoder and the transformed wind speed and direction on the test section axis were compared with the ones provided to the test section. As a result, up to yaw $20^{\circ}$ at a wind speed of 12 m/sec or over, the RMS error of wind speed was within the double of the ultrasonic anemometer error. But at yaw $30^{\circ}$, it was over the double of the ultrasonic anemometer error. Regardless of wind speed, at yaw $20^{\circ}$ and $30^{\circ}$, the direction error was within the double of the ultrasonic anemometer error. But at yaw $10^{\circ}$ or less, it was within the error of the ultrasonic anemometer itself. This is a very favorable characteristic to be used for wind turbine yaw control.

A Study on a Sensitivity Analysis of Design Parameters for the Speed-up of Overhead Rigid Conductor System (강체전차선로 고속화를 위한 설계파라미터 민감도 분석 연구)

  • Lee, Kiwon;Cho, Yong Hyeon;Kwon, Sam-Young;Park, Young
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.2
    • /
    • pp.453-458
    • /
    • 2017
  • R-Bar (Overhead Rigid Conductor system) has been lately used for the speed of over 200km/h in Europe, while it has been developed and used for the max. speed of 120km/h in Korea. Because R-Bar has advantages of reduction of tunnel cross sectional area and maintenance, its development for more high-speed is urgent in Korea having many mountain area. Therefore a sensitivity analysis of design parameters for the speed-up of R-Bar has performed in this study. For the analysis, we have developed a program for the prediction of dynamic characteristics between a pantograph and R-Bar. The program was evaluated with the actual test result and a current collection performance according to the parameters such as a distance between brackets, a stiffness of bracket and of R-Bar rail was predicted with the program.