• Title/Summary/Keyword: Spacers

Search Result 250, Processing Time 0.028 seconds

Natural Convection in the Annulus between a Horizontal Conducting Tube and a Cylinder with Spacers (수평전도관(水平傳導管)과 원통(圓筒)사이에 격판(隔板)을 가진 환상공간(環狀空間)에서의 자연대류(自然對流))

  • Lee, Sang-Hoon;Lee, Bum-Chul;Kwon, Sun-Sok
    • Solar Energy
    • /
    • v.7 no.2
    • /
    • pp.86-97
    • /
    • 1987
  • Natural convection in the annulus between a horizontal conducting tube and a cylinder with spacers has been studied by 2-dimensional numerical method with finite difference techniques. The effects of Rayleigh number, conductivities of conducting tube and spacer, and position of spacers were studied analytically. In case of vertical spacers, the maximum local Nusselt number appears at ${\theta}{\approx}50^{\circ}$ in a conducting tube and ${\theta}{\approx}30^{\circ}$ in an outer cylinder, The local Nusselt numbers show positive values on the lower spacer, but negative values on the surface of the upper spacer. In case of horizontal spacers, the flow over the spacer is more active than that of under the spacer as the Rayleigh number increases. The maximum local Nusselt appeares at ${\theta}=180^{\circ}$ in a conducting tube and at ${\theta}=0^{\circ}$ in an outer cylinder. The local Nusselt numbers show positive values on the upward surface, but negative values on the downward surface of spacer. As the dimensionless conductivity increases, the mean Nusselt number remarkably increases at $K_w/K_f<48$ and show almost even at $K_w/K_f{\ge}48$. The mean Nusselt number of a conducting tube with vertical spacers is 5.12 percent less and with horizontal spacers is 11.33 percent less than that of a conducting tube without spacer at $Ra=10^4$, Pr = 0.7 and $K_w/K_f=48$.

  • PDF

Countermeasures to prevent contact between phases on overhead lines (가공송전선로 상(相)간 혼촉으로 인한 고장 예방 대책)

  • Park, Yoon-Seok;Kim, Yong-Rak;Kim, Ho-Ki;Kim, Won-Jin;Choi, Jin-Sung
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.109-110
    • /
    • 2007
  • Most transmission lines pass through mountainous terrain and deep valleys, to avoid populated areas. Accordingly, the impact of climate changes, environmental conditions and system expansion have caused an increase in transmission line system fault rates. KEPCO has developed and applied phase-spacers to reduce contact faults between phases. Contact between phases represented 9% of total line faults before the devices were installed. Phase-spacers have reduced faults by up to 3.4% since the phase-spacers were installed in 2005. Also, recently developed devices provide additional economic benefits as they cost about a third of the price as similar devices introduced in foreign countries. Phase-spacers are an effective way to prevent phase contact accidents by maintaining physical space between phases. These spacers will be implemented in areas where contacts are likely to occur. They are expected to reduce accident rates and improve power quality.

  • PDF

Synthesis and Liquid Crystalline Properties of Hyperbranched Aromatic Polyesters Consisting of Azoxybenzene Mesogens and Polymethylene Spacers

  • Park, Young-Suk;Lee, Jun-Woo;Jin, Jung-Il
    • Bulletin of the Korean Chemical Society
    • /
    • v.23 no.9
    • /
    • pp.1201-1210
    • /
    • 2002
  • A new series of hyperbranched aromatic polyesters containing azoxybenzene mesogens and polymethylene spacers were prepared by polymerizing AB2 type monomers that have the isophthaloyl dicarboxylic acid terminal at one end and the p-oxyp henol terminal at the other end. The monomers contain a built-in azoxybenzene mesogen that is linked to the terminal groups through polymethylene spacers. The polyesters prepared were characterized by solution viscosity, differential scanning calorimetry, X-ray diffractometry and polarizing microscopy. All of the polyesters were found to be thermotropic (nematic). Their glass-transition temperatures and mesophase temperature ranges were very sensitive to the length of the two spacers existing in the repeating unit. The degree of branching of one of the polyesters was determined by the NMR spectroscopy and found to be 0.56.

Application of spacers for increasing OCC solid content in wet pressing process (I) (스페이서 사용에 의한 OCC 압착공정의 고형분 증대 (I))

  • Hwang, In-Young;Lee, Young-Ho;Jung, Jae-Gwon;Sung, Yong-Joo;Seo, Yung-Bum
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.44 no.4
    • /
    • pp.1-7
    • /
    • 2012
  • The increase of OCC solid content after wet pressing will save drying energy greatly. We applied spacers, which used to increase draining rate and bulk in fiber furnishes, to increase the OCC solid contents. MDF fibers (fibers for making medium density fiberboard) and diatomaceous earth were used as spacers, and added 10% by weight to the OCC fiber furnish. Application of high wet pressing pressure to the mixed furnish of spacers and refined OCC did not deteriorate bulk and drainage rate, but their solid contents were increased to 0.5-1.5% without loss of compressive strength when compared to those of unrefined OCC, which is the furnish normally used for mill commercial practice. It is believed that the spacers caused the rate of solid content increase faster in the mixed furnish with OCC at high wet pressing pressure area than the unrefined OCC furnish did. Little amount of starch addition (0.5%) to the spacers helped to keep the strength properties.

Three-dimensional Analysis for Three-phase Spacers in Gas Insulated System (3차원 전계해석 기법을 이용한 GIS 삼상 일괄형 스페이서 고찰)

  • Kang, J.S.;Lee, B.W.;Kang, S.M.;Oh, I.S.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07c
    • /
    • pp.1620-1622
    • /
    • 2003
  • Recently, as the technology for the development of high voltage power apparatus using SF6 gas has made remarkable progress, it became possible to develop more compact power apparatus adopting single body substation system. In these gas insulated power apparatus, it is impossible to achieve perfect and safe insulation using only SF6 gas, because some solid insulation parts should be installed to support current-carrying conductor parts for electrical and mechanical safety. When spacers were installed in SF6 gas insulation system, they were exposed to severe electrical intensification which could reduce system insulation performance and restrict the rated operating voltage So, it is necessary to clarify the dielectric characteristics of spacers by analytically and experimentally, in order to design and develop more compact and optimum gas insulated systems. In this paper, the field distribution of three-phase spacers were investigated using three dimensional electrostatic field analysis tool adopting BEM method. And the obtained results were compared to the conventional two dimensional computations. According to these three dimensional calculations, it was possible to find out weak points in the spacer more clearly and these results could be applied to design more compact and optimum three phase spacer developments.

  • PDF

Kissing of Sub-conductors due to Magnetic Forces in a 154 kV Bundled Overhead Transmission Line (154 kV 복도체 가공송전선로에서 전자력에 의한 소도체간 접촉)

  • Kim, Sang-Beom;Noh, Hee-Won;Kim, Young-Hong;Ko, Kwang-Man;Park, Jong-Hyuk;Kim, Sang-Soo
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.2 no.3
    • /
    • pp.383-389
    • /
    • 2016
  • Kissing of sub-conductors due to magnetic forces has been investigated in a 154 kV bundled overhead transmission line. With increasing ampacity of the conductors and enlarging the distance between spacers, lager magnetic force was measured. When the phase ampacity was 2,000 amps and the distance between two adjacent spacers was 68 m, for instance, the conductors became unstable and vibrated with a frequency of several herts. Furthermore, when the ampacity was 2,250 amps and the distance between spacers was 136 m, the two sub-conductors were contacted. Analysing the magnetic forces with distance of spacers, the safe distance of spacers to avoid contact of sub-conductors was presented. The change of the safe distance is discussed due to various parameters, such as residual stresses and wind pressures, in the real transmission lines.

Phylogenic Relationship of Rubus Cultivated in Korea Revealed by Chloroplast DNA Spacers (Chloroplast DNA Spacers로 분석한 국내 Rubus 재배종의 계통학적 유연관계)

  • Eu, Gee-Suck;Park, Myoung-Ryoul;Baek, So-Hyeon;Yun, Song-Joong
    • Korean Journal of Medicinal Crop Science
    • /
    • v.18 no.4
    • /
    • pp.266-272
    • /
    • 2010
  • There is a considerable difference in morphological traits between Bokbunja cultivated in Korea (KCB) and Korea native Rubus coreanus, contrary to the conviction that the cultivated Bokbunja is the domestication of R. coreanus. To infer the phylogenetic relationship of KCB with other Rubus species, we compared the chloroplast DNA spacers of KCB with those of several Rubus species including black raspberry, R. occidentalis. The three chloroplast DNA spacers, atpB~rbcL, trnL~trnF, and trnT~trnL, were amplified using the specific primer pairs and converted to Single Strand Conformational Polymorphism (SSCP) markers. The SSCP makers of the chloroplast DNA spacers showed a considerable variation both within and among Rubus species. In the phylogenetic tree generated by the SSCP markers, KCB accessions were located in the same clade with R. occidentalis, but R. coreanus accessions in the different clade. Also, in the phylogenetic tree by the nucleotide sequences of the chloroplast DNA spacer trnL~trnF, KCB located in the same clade with R. occidentalis but not with R. coreanus. These results suggest that the three KCB accessions share higher similarity with R. occidentalis than with R. coreanus in the three chloroplast DNA spacers.

A study on measures against subspan oscillation by twin spacers in 345kV overhead transmission lines(II) (345kV 가공선로에서 진동발생 다발 소경간에 대한 진동저감 대책(II))

  • Lee, H.K.;Han, H.J.;Park, C.K.;Choi, W.K.
    • Proceedings of the KIEE Conference
    • /
    • 2008.04b
    • /
    • pp.200-202
    • /
    • 2008
  • The oscillation is very dangerous in bundled transmission lines, especially 345kV 4 bundle transmission lines are very weak for subspan oscillations. In some cases, subspan oscillations are continuously occurred in the same subspan. In order to develop the control method of the above subspan oscillation, this paper suggests a method of applying twin spacers to the subspans. We have carried out some tests to analyze the oscillation phenomena after installing twin spacers on 34sky real lines, and we got a good effect for controling subspan oscillations.

  • PDF

Substrate-Assembling Technique using Adhesive Patterned Spacers for Flexible Liquid Crystal Displays

  • Kang, Jae-Hyun;Bae, Kwang-Soo;Yi, Seung-Woo;Kim, Jae-Hoon;Yu, Chang-Jae
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2009.10a
    • /
    • pp.218-220
    • /
    • 2009
  • We proposed an enhanced substrate-assembling technique using adhesive patterned spacers for flexible liquid crystal displays (LCDs). The negative photoresister was used for the rigid columnar spacers and the strong substrate-bonding agent. The proposed technique is expected to be a good candidate for manufacturing method of flexible LCDs.