• Title/Summary/Keyword: Source Level

Search Result 3,888, Processing Time 0.028 seconds

PD Source Detection of Oil Transformer Using Three-dimensional Construction (3차원 해석에 의한 유입변압기 PD발생점 탐지)

  • Yoon, Chul-Sub;Choi, Gil-Soo;Lee, Eun-Suk
    • Proceedings of the KIEE Conference
    • /
    • 1998.07c
    • /
    • pp.1036-1038
    • /
    • 1998
  • The while, PD source detection in the oil TR was the level of the planar source detection. and it is to respected scientific research. The planar source detection technique had limits which have difficulties finding out the point of deterioration generation. In this study, our purpose is a development of PD source detection technique with Three-Dimensional using a principle and a technique of the planar source location.

  • PDF

Quantitative Assessment of Nonpoint Source Load in Nakdong River Basin

  • Kwon, Heon-Gak;Lee, Jae-Woon;Yi, Youn-Jeong;Cheon, Se-Uk
    • Journal of Environmental Science International
    • /
    • v.23 no.1
    • /
    • pp.7-23
    • /
    • 2014
  • This study estimates unit for the nonpoint source(NPS), classified according to the existing Level-1(large scale) land cover map, by monitoring the measurement results from each Level-2(medium scale) land cover map, and verifies the applicability by comparison with previously calculated units using the Level-1 land cover map. The NPS pollutant loading for a basin is evaluated by applying the NPS pollutant unit to Dongcheon basin using the Level-2 land cover map. In addition, the BASINS/HSPF(Better Assessment Science Integrating point & Non-point Sources/Hydrological Simulation Program-Fortran) model is used to evaluate the reliability of the NPS pollutant loading computation by comparing the loading during precipitation in the Dongcheon basin. The NPS pollutant unit for the Level-2 land cover map is computed based on precipitation measured by the Sangju observatory in the Nakdong River basin. Finally, the feasibility of the NPS pollutant loading computation using a BASINS/HSPF model is evaluated by comparing and analyzing the NPS pollutant loading when estimated unit using the Level-2 land cover map and simulated using the BASINS/HSPF models.

Floating Power Supply Based on Bootstrap Operation for Three-Level Neutral-Point-Clamped Voltage-Source Inverter

  • Nguyen, Qui Tu Vo;Lee, Dong-Choon
    • Proceedings of the KIPE Conference
    • /
    • 2011.11a
    • /
    • pp.3-4
    • /
    • 2011
  • This paper presents a survey of floating power supply based on bootstrap operation for three-level voltage-source inverters. The floating power supply for upper switches is achieved by the bootstrap capacitor charged during on-time of the switch underneath. Hence, a large number of bulky isolated DC/DC power supplies for each gate driver are reduced. The Pspice simulation results show the behavior of bootstrap devices and the performance of bootstrap capacitor voltage.

  • PDF

Evaluating the Performance Quality of Open Source Database Management Systems (오픈소스 DBMS의 성능 품질 평가)

  • Min, Meekyung
    • Journal of Korean Society for Quality Management
    • /
    • v.45 no.4
    • /
    • pp.933-942
    • /
    • 2017
  • Purpose: The purpose of this paper is to evaluate the performance quality of the open source DBMSs. Performance quality is defined as processing time for Join queries. Query processing time is measured and compared in the most widely used open source DBMSs and commercial DBMS. Methods: By varying the number of tuples of two relations to be joined, the average processing time(seconds) of a Join query in each DBMS was obtained experimentally. ANOVA and Tukey HSD test were used in order to compare the performance quality of DBMSs. Results: There was a significant difference between the performance qualities of the three DBMSs at all experimental levels where the number of tuples was 100, 1,000, 2,000, 10,000, and 50,000. As a result of the Tukey HSD test, two open source DBMSs (MariaDB, MySQL) were classified in the same group only at the tuple level of 100. The commercial DBMS (MS-SQL Server) belonged to another group. At level of more than 1,000 tuples, all three DBMSs belonged to different groups. Conclusion: Within the open source DBMS group, MariaDB showed the better performance quality except for a small number of tuples. Thus the results show that MariaDB can be the alternative to MySQL which is currently most widely used. Between open source DBMS and commercial DBMS groups, MS-SQL Server always shows the best performance quality, but the less number of tuples, the less the difference.

Design and Implementation of a Multi Level Three-Phase Inverter with Less Switches and Low Output Voltage Distortion

  • Ahmed, Mahrous E.;Mekhilef, Saad
    • Journal of Power Electronics
    • /
    • v.9 no.4
    • /
    • pp.593-603
    • /
    • 2009
  • This paper proposes and describes the design and operational principles of a three-phase three-level nine switch voltage source inverter. The proposed topology consists of three bi-directional switches inserted between the source and the full-bridge power switches of the classical three-phase inverter. As a result, a three-level output voltage waveform and a significant suppression of load harmonics contents are obtained at the inverter output. The harmonics content of the proposed multilevel inverter can be reduced by half compared with two-level inverters. A Fourier analysis of the output waveform is performed and the design is optimized to obtain the minimum total harmonic distortion. The full-bridge power switches of the classical three-phase inverter operate at the line frequency of 50Hz, while the auxiliary circuit switches operate at twice the line frequency. To validate the proposed topology, both simulation and analysis have been performed. In addition, a prototype has been designed, implemented and tested. Selected simulation and experimental results have been provided.

A Study on the Predition of Train Noise Propagation from a Level Railroad (평탄부 선로에서 철도소음의 전파예측에 관한 연구)

  • 주진수;박병전
    • Journal of KSNVE
    • /
    • v.8 no.1
    • /
    • pp.187-194
    • /
    • 1998
  • In order to predict the train noise propagation from a level railroad, this paper presents the model of train noise source and the prediction model based on the results by using the sound intensity method. The prediction model gives the effects of geometric attenuation, ground attenuation, and barrier attenuation of noise. There are several principal assumption in developing model: (a) the train noise is primarily rolling noise; (b) the rail head and wheels are in good condition; (c) the height of source is 10cm above track; (d) the directivity pattern of train noise sources is a dipole source. Calculated results based on this model are compared with available field data and good agreement has been obtained.

  • PDF

Investigation on Radiation Characteristics of 42″ AC-PDP (42″ AC-PDP의 방사특성에 대한 연구)

  • Lim Heon-Yong;Kim Min-Seok;Park Dongwook;Lee Jeong-Hae
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.15 no.9
    • /
    • pp.841-847
    • /
    • 2004
  • EMI emission characteristics of 42" AC-PDP panel are investigated in this paper. First, EMI emission source was modeled the scan electrode and the sustain electrode to a simple electric and magnetic dipole type radiator. Second, EMI emission source was modeled as reconfigured the scan electrode and the sustain electrode. The primary source of EMI emission was investigated using FEM calculation of the wave impedance and 3 dB beam width. The third. the EMI emission level was estimated using the measured sustain electrode current. Also, EMI emission level of 42" AC-PDP was measured. The results show that the calculated EMI emission level from the simple electric dipole model was shown to agree with that from the corresponding FEM simulation.

Leg-By-Leg-Based Finite-Control-Set Model Predictive Control for Two-Level Voltage-Source Inverters

  • Zhang, Tao;Chen, Xiyou;Qi, Chen;Lang, Zhengying
    • Journal of Power Electronics
    • /
    • v.19 no.5
    • /
    • pp.1162-1170
    • /
    • 2019
  • Finite-control-set model predictive control (FCS-MPC) is a promising control scheme for two-level voltage-source inverters (TL-VSIs). However, two main issues arise in the classical FCS-MPC method: an exponentially-increasing computational time and a low steady-state performance. To solve these two issues, a novel FCS-MPC method has been proposed for n-phase TL-VSIs in this paper. The basic idea of the proposed method is to carry out the FCS-MPC scheme of TL-VSIs for one leg by one leg, like a "pipeline". Based on this idea, the calculations are reduced from exponential time to linear time and its current waveforms are improved by applying more switching states per sampling period. The cases of three-phase and five-phase TL-VSIs were tested to verify the effectiveness of proposed method.

Vertical System Testing Method For Efficient Error Tracing (효과적인 오류 추적을 위한 수직적 시스템 시험 방법)

  • Seo, Kwang-Ik;Choi, Eun-Man
    • Journal of the Korea Society of Computer and Information
    • /
    • v.13 no.2
    • /
    • pp.19-29
    • /
    • 2008
  • In case of unit testing, White-box test can be used to closely check source code and to analyze logic and statement errors. On the other hand, in case of function testing of system level, Black-box test can be mainly used to compare actual and expected results by inputting test data because the scale of function is large. This Black-Box test in system testing level has problem in tracing errors in source code when we find errors. Moreover applying White-box test is not easy for system testing level because the levels of test target are different. Therefore this paper suggests the vertical test method of a practical and integrated system level which can checks up to source code level using White-box test style although it aims to test the highly abstract level like a system function. In addition, the experiment explains how to apply the vertical test by displaying an example which traces from UML specification model to the source code and also shows efficiency of error trace.

  • PDF

Modeling and Experimental Validation of 5-level Hybrid H-bridge Multilevel Inverter Fed DTC-IM Drive

  • Islam, Md. Didarul;Reza, C.M.F.S.;Mekhilef, Saad
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.2
    • /
    • pp.574-585
    • /
    • 2015
  • This paper aims to improve the performance of conventional direct torque control (DTC) drives proposed by Takahashi by extending the idea for 5-level inverter. Hybrid cascaded H-bridge topology is used to achieve inverter voltage vector composed of 5-level of voltage. Although DTC is very popular for its simplicity but it suffers from some disadvantages like- high torque ripple and uncontrollable switching frequency. To compensate these shortcomings conventional DTC strategy is modified for five levels voltage source inverter (VSI). Multilevel hysteresis controller for both flux and torque is used. Optimal voltage vector selection from precise lookup table utilizing 12 sector, 9 torque level and 4 flux level is proposed to improve DTC performance. These voltage references are produced utilizing a hybrid cascaded H-bridge multilevel inverter, where inverter each phase can be realized using multiple dc source. Fuel cells, car batteries or ultra-capacitor are normally the choice of required dc source. Simulation results shows that the DTC drive performance is considerably improved in terms of lower torque and flux ripple and less THD. These have been experimentally evaluated and compared with the basic DTC developed by Takahashi.