• 제목/요약/키워드: Sound Insulation Measurement

검색결과 86건 처리시간 0.027초

실험실 실험을 통한 벽체 차음성능 측정의 신뢰성 향상을 위한 실험적 연구 (An Experimental Study to Improve Measurement Reliability for the Airborne Sound Insulation Performance by Laboratory Test)

  • 김항;박현구;구희모;김선우
    • 한국소음진동공학회논문집
    • /
    • 제24권1호
    • /
    • pp.35-44
    • /
    • 2014
  • Sound pressure levels in the receiving room while testing airborne sound insulation performance are varied by the measuring points. This may increase the measurement error, then decrease the measurement reliability. With this reason the research has carried out on the method to reduce deviations of sound pressure level in the ISO type rectangular laboratory focusing on the measurement of airborne sound insulation performance. Tests were made to see the effect of sound absorption in the receiving room, loudspeaker locations, microphones locations and flanking transmission path. Consequently, it was resulted that sound absorption in the receiving room and the loudspeaker location have influence on the sound level deviations especially in the low frequency. The microphone location was very important to get measurement reliability. The effective measuring point, which the sound level difference with average sound pressure level is within 2 dB, could yield most reliable average sound pressure level. Therefore it is necessary to find the effective measuring points in the receiving room. Flanking transmission path should be sealed using sound absorber or magnet etc. to prevent from lowering the sound insulation performance.

차음성능 측정에 있어서의 암소음의 영향의 저감 (1) (Recuction of the Influence of Background Noise in Sound Insulation Measurement)

  • 염성곤;다치바나히데끼
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 춘계학술대회논문집
    • /
    • pp.495-498
    • /
    • 2004
  • In the sound insulation measurements, the influence of background (extraneous) noise is often serious problem and how to reduce its effect and to improve the signal-to-noise(S/N) ratio is an important theme. As the background noise, such extraneous noises as road traffic noise and machine noise often disturb the measurement. In laboratory measurements on specimens with high sound insulation performances, even the internal noise of the measurement system can become a problem. To improve the signal-to-noise ratio and to improve the measurement accuracy, various kinds of digital signal processing techniques can be applied. In this paper, four kinds of digital signal processing techniques are applied and their effectiveness is examined by a simple sound insulation measurement.

  • PDF

현장에서의 창의 차음성능 측정방법에 관한 실험적 연구 (An Experimental Study on the Field Measurement Methods of the Sound Insulation Performance of Window)

  • 이옥균;박현구;최형욱;송혁;김선우
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 춘계학술대회논문집
    • /
    • pp.600-605
    • /
    • 2000
  • The aim of this study is to compare the sound insulation performances of window depending on the measurement methods through the field test and analyze the factors that affect the sound insulation performances. Four measurement methods which are specified in the Koran Standard 2235 and the International Standard 140-5 were selected for the study; the outdoor sound source method which is classified the l000mm method and the 10mm method, the indoor sound source method, and the ISO method. The result of this study is that the sound insulation performance of the windows was the best when measured according to the ISO method and the worst the indoor sound source method. Through the study it was found that the main factors affecting the sound insulation performance of the windows were the correction of the specimen's area and the equivalent sound absorption area of the receiving room.

  • PDF

공동주택 단지 내 주민공동시설의 소음 방지를 위한 공기전달음 차단 성능 현장 조사 (Field Measurement of Airborne Sound Insulation for Noise Reduction about Community Facilities in an Apartment Complex )

  • 성요한;김진식;김혜원;조성준
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2023년도 봄 학술논문 발표대회
    • /
    • pp.249-250
    • /
    • 2023
  • The objective of this study is to evaluate the airborne sound insulation performance between housing units and community facilities during the construction phase. Community facilities adjacent to housing units can lead to noise problems, hence it is necessary to minimize noise transmission during the design phase. However, flanking noise transmitted through gaps of structures, windows, pipes, and other openings may result in substandard sound insulation performance falling below the design standards. Therefore, It is crucial to measure airborne sound insulation in the field during the construction phase. The measurement was conducted using the survey method for the field measurement of the airborne sound insulation in accordance with KS F ISO 10052:2021. Although the noise standards caused by community facilities in apartment complexes are not specified in current laws and regulations, desired noise level was set based on international guidelines for indoor noise. First, the level of noise generated in community facilities was estimated, and then the sound insulation performance was evaluated to determine whether the desired noise level was achieved.

  • PDF

경량충격음 차단성능 실험실 측정방법 고찰 (A Survey on the Laboratory Measurements of Impact Sound Insulation of Floors)

  • 송민정;장길수;고성석;김선우
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 추계학술대회논문집
    • /
    • pp.976-979
    • /
    • 2004
  • The KS of 'Laboratory Measurement of Impact Sound Insulation of Floors' is not established yet. To establish this KS, present conditions of domestic laboratory test facilities for measuring impact sound insulation of floors in laboratory and current researches were reviewed As a result the outline of 'Laboratory Measurement of Impact Sound Insulation of Floors' is suggested.

  • PDF

차음성능 측정에 있어서의 암소음의 영향의 저감 (2) (Recuction of the Influence of Background Noise in Sound Insulation Measurement)

  • 염성곤;다치바나 히데끼
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 추계학술대회논문집
    • /
    • pp.441-444
    • /
    • 2004
  • In the sound insulation measurements, the influence of background (extraneous) noise is often serious problem and how to reduce its effect and to improve the signal-to-noise(S/N) ratio is an important theme. As the background noise, such extraneous noises as road traffic noise and machine noise often disturb the measurement. In laboratory measurements on specimens with high sound insulation performances, even the internal noise of the measurement system can become a problem. To improve the signal-to-noise ratio and to improve the measurement accuracy, various kinds of digital signal processing techniques can be applied. In this paper, four kinds of digital signal processing techniques are applied and their effectiveness is examined through field measurements.

  • PDF

공동주택 경량바닥충격음 측정불확도 추정에 관한 연구 (A Study on Estimation of Uncertainty in Measurement of Light Impact Sound Insulation of Floors)

  • 고종철;이종인;김현배;이철
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 춘계학술대회논문집
    • /
    • pp.1409-1416
    • /
    • 2006
  • In measuring, uncertainty in measurement is essential to improve measuring reliability. Currently, however, in measuring impact sound insulation of floors, there are no guidelines to estimate uncertainty in measurement. In addition, the concept of uncertainty in rating is required to recognize the relation between measuring and rating. Therefore, through this paper, the efforts have been made to establish uncertainty in measurement and rating of light impact insulation of floors. The result of estimating of uncertainty in measurement and rating in our laboratory is considered reliable, considering ${\pm}0.46{\sim}1.44dB$ of uncertainty in measurement and 1 dB of uncertainty in rating.

  • PDF

공동주택에서 중공 슬래브 바닥의 차음 특성에 관한 연구 (A Study on the Characteristics of Sound Insulation at the Circular Voided Concrete Floor in the Multi-Housing)

  • 손철수
    • 한국주거학회논문집
    • /
    • 제11권1호
    • /
    • pp.171-181
    • /
    • 2000
  • The purpose of the resent research is to investigate the characteristics of sound insulation at the circular voided concrete slab in the multi-housing. In order to do this research, the method for field measurement of floor impact sound level was used following the Korea Standard F2810-1996. For the multi-housing, three kinds of circular voided concrete slabs are used to measure the characteristics of sound insulation.The results are as follows; 1.The main factor affecting the characteristics of sound insulation at the circular voided concrete slab in the multi-housing is sound-absorbing materials in the circular tube. 2. The main factor to effect the difference of sound pressure level is circular tube in the concrete slab. 3. The forms of circular tubes effect the characteristics of sound insulation at the circular tube. 4. Sound Pressure Level resulting from the piping direction of circular tubes in little different to octave band level.More study will be needed about the depth and distance of sound insulation materials, and the components of sound insulation materials for the multi-housing.

  • PDF

표준중량충격원을 이용한 건축물의 바닥 충격음 차단성능 측정불확도 평가 (Evaluation of uncertainty in measurement of floor impact sound insulation of buildings using standard heavy impact source)

  • 이용봉;권혁제;김창환;조만희;김항;정성수
    • 한국음향학회지
    • /
    • 제42권2호
    • /
    • pp.143-151
    • /
    • 2023
  • 본 논문은 표준 중량충격원을 이용한 건축물의 바닥충격음 차단성능을 측정하는 경우 측정불확도를 평가하는 방법을 다루었다. 반복 측정의 영향 이외에도 측정 위치의 영향, 가진 위치의 영향, 음압측정에 사용된 장비의 영향 및 충격원의 영향 등을 고려하였다. 평균 최대 바닥충격음 레벨 측정의 수학적 모델을 제시하고 요인별 불확도 평가방법을 제안하였으며, 제안한 방법을 실제 측정 결과에 적용하여 평균 최대 바닥충격음 레벨 및 측정불확도를 평가하였다.

공항 인근 건물(호텔)에서의 벽체구조의 차음성능에 관한 연구 (An experimental study on sound insulation of building elements of the hotel near airport)

  • 이성호;정갑철;양관섭
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 춘계학술대회논문집
    • /
    • pp.579-585
    • /
    • 2002
  • This study has measured and evaluated the sound insulation of building elements of the hotel near airport. That measurement was made in both the actual site and laboratory. The differences of sound insulation performance in between granite and double glass were measured. Moreover, the difference of sound insulation was analyzed. For the measurement, this study has tried several methodologies, and analyzed the differences respectively. The results from this analysis were applied to produce a design guides for sound insulation to prevent external noise and to make more silent indoor space which satisfied the standard rate of noise.

  • PDF