• Title/Summary/Keyword: Similar Evaluation Function

Search Result 245, Processing Time 0.031 seconds

A Study on Developing a Child Hospital Gown (어린이용 환자복 디자인 개발 방법에 대한 연구)

  • 서동애;천종숙
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.21 no.5
    • /
    • pp.854-864
    • /
    • 1997
  • This study was initiated to develop a uniform design suitable for child inpatients. The experimental hospital inpatient uniform design was developed based on the results of the prior studies. The panel was composed of 5 experienced nurses and 5 clothing specialists. They evaluated the function of the experimental inpatient uniforms developed in this study. The experimental hospital gown design was reformed based on the panel's evaluation.1'hen the child inpatients performed the wear test for the reformed experimental hospital gown. The results of the study are as follows; 1. The child inpatient hospital gown design of the most hospitals were similar to the adult patient's uniform : the V-neckline shirts with full length set-in sleeves. The bottom was full length pull-on pants. The fabric was white cotton with blue hospital logo and stripe print in most cases. 2. The panel's specialty affected the evaluation of the uniform design. The nurses concerned about the durability after washing and ease for medical treatment. The clothing specialists cared about the features related to the clothing construction and ease for physical movement of body. 3. The most preferred hospital inpatient uniform design by the panels was the shirts or one- piece gown with three-quarter length sleeve and overarm seam opening. 4. The researchers developed one-piece dress gown for the children under two years old. Three different size pajamas were developed for children 2∼5 years old,5∼8 years and 8∼12 years old.

  • PDF

Evaluation of a Possibility of Estimation of Reaction Force of Surgical Robot Instrument using Sliding Perturbation Observer (슬라이딩 섭동 관측기를 이용한 수술용 로봇 인스트루먼트의 반력 추정 가능성 평가)

  • Yoon, Sung-Min;Lee, Min-Cheol;Kim, Chi-Yen;Kang, Byeong-Ho
    • The Journal of Korea Robotics Society
    • /
    • v.7 no.1
    • /
    • pp.20-28
    • /
    • 2012
  • In spite of the difficulties and uncertain characteristic of cable driven method, surgical robot instrument has adopted it as driving mechanism for various reasons. To overcome the problem of cable system, previous research applied SMCSPO (sliding mode control with sliding perturbation observer) algorithm as robust controller to control the instrument and found that the value of SPO (sliding perturbation observer) followed force disturbance, reaction force loaded on the tip very similarly. Thus, this paper confirms that the perturbation observer is sufficient estimator which finds out the mount of loaded force on the surgical robot instrument. To prove the proposition, simulation using the similar model with an actual instrument and experimental evaluation are performed. The results show that it is possible to substitute SPO for sensors to measure the reaction force. This estimated reaction force will be used to realize haptic function by sending the reaction force to a master device for a surgeon. The results will contribute to create surgical benefit such as shortening the practice time of a surgeon and giving haptic information to surgeon by using it as haptic signal to protect an organ by making force boundary.

Measurement uncertainty evaluation in FaroArm-machine using the bootstrap method

  • Horinov, Sherzod;Shaymardanov, Khurshid;Tadjiyev, Zafar
    • Journal of Multimedia Information System
    • /
    • v.2 no.3
    • /
    • pp.255-262
    • /
    • 2015
  • The modern manufacturing systems and technologies produce products that are more accurate day by day. This can be reached mainly by improvement the manufacturing process with at the same time restricting more and more the quality specifications and reducing the uncertainty in part. The main objective an industry becomes to lower the part's variability, since the less variability - the better is product. One of the part of this task is measuring the object's uncertainty. The main purpose of this study is to understand the application of bootstrap method for uncertainty evaluation. Bootstrap method is a collection of sample re-use techniques designed to estimate standard errors and confidence intervals. In the case study a surface of an automobile engine block - (Top view side) is measured by Coordinate Measuring Machine (CMM) and analyzed for uncertainty using Geometric Least Squares in complex with bootstrap method. The designed experiment is composed by three similar measurements (the same features in unique reference system), but with different points (5, 10, 20) concentration at each level. Then each cloud of points was independently analyzed by means of non-linear Least Squares, after estimated results have been reported. A MatLAB software tool used to generate new samples using bootstrap function. The results of the designed experiment are summarized and show that the bootstrap method provides the possibility to evaluate the uncertainty without repeating the Coordinate Measuring Machine (CMM) measurements many times, i.e. potentially can reduce the measuring time.

AN EVALUATION FORMULA FOR A GENERALIZED CONDITIONAL EXPECTATION WITH TRANSLATION THEOREMS OVER PATHS

  • Cho, Dong Hyun
    • Journal of the Korean Mathematical Society
    • /
    • v.57 no.2
    • /
    • pp.451-470
    • /
    • 2020
  • Let C[0, T] denote an analogue of Wiener space, the space of real-valued continuous functions on the interval [0, T]. For a partition 0 = t0 < t1 < ⋯ < tn < tn+1 = T of [0, T], define Xn : C[0, T] → ℝn+1 by Xn(x) = (x(t0), x(t1), …, x(tn)). In this paper we derive a simple evaluation formula for Radon-Nikodym derivatives similar to the conditional expectations of functions on C[0, T] with the conditioning function Xn which has a drift and does not contain the present position of paths. As applications of the formula with Xn, we evaluate the Radon-Nikodym derivatives of the functions ∫0T[x(t)]mdλ(t)(m∈ℕ) and [∫0Tx(t)dλ(t)]2 on C[0, T], where λ is a complex-valued Borel measure on [0, T]. Finally we derive two translation theorems for the Radon-Nikodym derivatives of the functions on C[0, T].

Effect of Analytical Method on the Pharmacokinetic Evaluation of Bromosulfophthalein: Comparison of HPLC and UV Spectroscopy Method (Bromosulfophthalein의 체내동태 평가에 미치는 분석법의 영향: HPLC 법과 UV 흡광광도법의 비교)

  • Oh, Ju-Hee;Cha, You-Kyoung;Lee, Young-Joo
    • Journal of Pharmaceutical Investigation
    • /
    • v.38 no.6
    • /
    • pp.399-403
    • /
    • 2008
  • The aim of this study was to evaluate the difference of analytical methods for the pharmacokinetic study of bromosulfophthalein (BSP), an indicator of hepatobiliary function. The plasma and bile concentrations of BSP after intravenous administration were measured according to custom UV spectroscopy and HPLC, respectively. Plasma concentration of BSP measured by UV spectroscopy was similar to that measured by HPLC. There was no significant difference in the distribution volume, total body clearance, area under the curve and mean residence time of BSP between different analytical method groups. However, bile concentration of BSP measured by UV spectroscopy was overestimated compared with concentration measured by HPLC method. Biliary clearance of BSP obtained from UV spectroscopy method was almost 3 times higher than that obtained from HPLC method. Thus, a feasibility of UV spectroscopy method for high throughput pharmacokinetic evaluation of BSP was limited to the study based on the plasma concentration of BSP, not bile concentration.

Measuring Recreational Benefits of Chilgap Reservoir Using TCM (TCM을 이용한 칠갑저수지의 레크리에이션 편익 분석)

  • Hong, Seungjee;Kim, Dae-Sik
    • Journal of Korean Society of Rural Planning
    • /
    • v.22 no.3
    • /
    • pp.97-106
    • /
    • 2016
  • The study attempts to estimate the recreational benefits of Chilgap multi-purpose reservoir using the on-site survey sample of 130 visitors. The individual travel cost method is used for measuring the recreational benefits of Chilgap multi-purpose reservoir and a zero-truncated negative binomial model is used to elicit the travel demand function. The price elasticities of visit demand are ranged from 0.29 to 0.39. Recreational benefits are ranged from 119 to 156 thousand won per visit and are ranged from 292 to 383 thousand won per annual. When the number of annual visitors to Chilgap reservoir is appled, then the recreational benefits are ranged from 2.7 to 3.6 billion won. This study could contribute to the advancement of post-construction evaluation in the public construction field similar to Chilgap reservoir.

Numerical Analysis of Fusible Filler Behavior for Self-Interconnection Process (자기 접속 프로세스에 대한 볼륨 입자 거동에 대한 수치해석 연구)

  • Gwon, Hyeok-Rok;Lee, Jeong-Hui;Kim, Jong-Min;Lee, Seong-Hyeok
    • Proceedings of the KWS Conference
    • /
    • 2006.10a
    • /
    • pp.178-180
    • /
    • 2006
  • The present article aims to develop a numerical method for numerical analysis of fusible filler behavior for self-interconnection process. The CIP(Cubic Interpolated Propagation) method is used for determination of interfaces and the CSF(Continuum Surface Force) model is adopted for evaluation of curvature. To validate these models, first, the present study performs the numerical simulation for a droplet formation and it simulates the interactions among fusible fillers inside resin under the operating condition. As a result, similar tendency is found compared to the experimental observation. This study would be a first step towards finding the optimum condition for self-interconnection process.

  • PDF

Evaluation of Physical Properties and Adsorption Capacity of Regeneration GAC (재생 활성탄의 물성 및 흡착능 평가)

  • Mun, Ji-Young;Chae, Seon-Ha;Wang, Chang-Keun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.23 no.4
    • /
    • pp.407-416
    • /
    • 2009
  • The objective of this study was to evaluate the variation of physical properties and adsorption capacity after regeneration of Granular Activated Carbon (GAC). It was found that the loss rate of regenerated carbon was related to the usage time of GAC. The correlations between iodide number and loss rate also determined. Effective size and uniformity coefficient for regenerated GAC were within a similar range compared to virgin GAC. This result indicated that the function as media is recovered. Although iodide number and specific surface area for regenerated GAC were not completely recovered compared to that of virgin GAC, cumulative pore volumes of regenerated GAC were increased. Removal efficiency of organic matter in regenerated GAC was resulted the same or slightly higher than that of virgin GAC. This result indicates that the number of mesopore responsible for removal of organic matter was increased after regeneration.

Development of Modeling Method for 3-D Positioning of IKONOS Satellite Imagery (IKONOS 위성영상의 3차원 위치 결정 모형화 기법 개발)

  • 진경혁;홍재민;유환희;유복모
    • Proceedings of the Korean Society of Surveying, Geodesy, Photogrammetry, and Cartography Conference
    • /
    • 2004.11a
    • /
    • pp.269-274
    • /
    • 2004
  • Recent adoption of the generalized sensor model to IKONOS and Quickbird satellite imagery have promoted various research activities concerning alternative sensor models which can replace conventional physical sensor models. For example, there are the Rational Function Model(RFM), the Direct Linear Transform(DLT) and the polynomial transform. In this paper, the DLT model which uses just a few number of GCPs was suggested. To evaluate the accuracy of the proposed DLT model, the RFM using 35 GCPs and the bias compensation method(Fraser et al., 2003) were compared with it. Quantitative evaluation of 3B positioning results were performed with independent check points and the digital elevation models(DEMs). In result, a 1.9- to 2.2-m positioning accuracy was achieved for modeling and DEM accuracy is similar to the accuracy of the other model methods.

  • PDF

Quantitative Evaluation on Laser Performance for Endovenous Photocoagulation (레이저를 이용한 하지정맥류 치료의 정량화 연구)

  • Ahn, Minwoo;Nguyen, Van Phuc;Oh, Junghwan;Kang, Hyun Wook
    • Journal of Biomedical Engineering Research
    • /
    • v.35 no.3
    • /
    • pp.62-67
    • /
    • 2014
  • The purpose of the study was to identify the effect of laser parameters on photocoagulation to maximize safety and efficacy during varicose vein treatment. CW and pulsed modes at 1470 nm were initially compared as a function of power on bovine liver tissue. In the pulsed mode, various parameters including repetition rate, duty cycle, and irradiation time were compared to evaluate tissue response during thermal treatment. The results demonstrated that CW and pulsed modes yielded almost similar coagulation development possibly due to shorter irradiation time of 5 sec. Regardless of laser mode, both repetition rate and duty cycle presented constant coagulation rate whereas longer irradiation time facilitated coagulation process.