• Title/Summary/Keyword: Short Circuit Current

Search Result 1,004, Processing Time 0.021 seconds

A comparative study of electrical properties of arachidic acid LB films in the Al/LB/Al and Au/LB/Au electrode structure (Al/LB/Al, Au/LB/Au 전극 구조에서 arachidic acid LB막의 전기적 특성에 관한 비교 연구)

  • 오세중;김정수
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.44 no.10
    • /
    • pp.1311-1316
    • /
    • 1995
  • The electrical properties of the Langmuir-Blodgett (LB) films layered with arachidic acid were studied at the room temperature. The sample was formed with 2 different structure ; One was Al/LB/Al and the other was Au/LB/Au. The precise structure of Al/LB/Al was considered as Al/Al$_{2}$O$_{3}$/LB/Al, because the natural oxide layer was formed on surface of lower Al electrode. The electrical conductivity of Al/Al$_{2}$O$_{3}$/LB/Al structure was determined the value of 3.5 * 10$^{-14}$ S/cm from the measurement of current-voltage (I-V) characteristics. The sample with the structure of Au/LB/Au was made to eliminate the influence of oxide layer in the electrical properties of the LB films. The short circuit current was observed in this sample from the I-V characteristics. To verify the reason of short circuit current generation, copper decoration method was employed to the 15 layers of LB films deposited on the Al and Au electrode each. The defects were shown on the films deposited with Au electrode. This results means that the defects on the LB films which layered with the Au electrode were contributed to the short circuit current. Several films (15, 31, 51, 71L) were deposited on the Au electrode and measured the size of defects with the copper decoration method. The size of defects becomes smaller as the film layer was increased. We conclude that the existence of defects affects the short circuit current generation.

  • PDF

Analysis on Insulation and Protection Characteristics of Grid Connected ESS in Ground/Short-Circuit Fault (지/단락실증시험에서 MW급 계통연계형 ESS 절연/보호시스템 성능 분석에 관한 연구)

  • Kim, Jin-Tae;Lee, Seung-Yong;Park, Sang-Jin;Cha, Han-Ju;Kim, Soo-Yeol
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.6 no.2
    • /
    • pp.119-122
    • /
    • 2020
  • With recent ESS (Energy Storage System) fire accident, the fault protection performance is becoming more important. However, there has never been any experiments with the protection performance on the faults in the ESS system level. In this study, the effect of AC ground fault and IGBT (Insulated Gate Bipolar mode Transistor) short-circuit failure on MW class ESS was performed experimentally for the first time in the world. First of all, the effect of the AC single line ground fault on battery was analyzed. Moreover, the transient voltage was investigated as a function of the battery capacity and the power level. Finally, the breaking capability and insulation performance of ESS were examined under PCS short-circuit fault condition. Through the tests, it was found that ESS protection system safely blocked the faulty current regardless of the faults, whereas the electronic parts such as IGBT and MC (Magnetic Contactor) were broken by the fault current. Also, the electrical breakdown in ESS resulted from the transient voltage during the protection process.

Controlling the Residual Flux in Transformer to Prevent the Distortion of Short-circuit Current (단락 전류 왜형방지를 위한 변압기 잔류자속제어)

  • Oh, Seung-Ryle;Park, Ji-Hun;Park, Jong-Wha
    • Proceedings of the KIEE Conference
    • /
    • 2006.11a
    • /
    • pp.237-239
    • /
    • 2006
  • The residual flux(${\psi}_r$) in transformer's iron cores cause the distortion of short-circuit current occasionally. And some considerable distortion effect on the validation of test results. To prevent this situation, there needs some suitable control of residual flux through the pretest. This paper deals with the how to control the residual flux in pretest and the comparison between the two test results which were obtained by different test method.

  • PDF

The Stydy on Short-circuit Current of Polymeric Material Sandwitched by Two Different Kinds of Metal (이종금속으로 샌드위치된 고분자의 단락전류에 관한 연구)

  • 이덕출;이능헌
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.35 no.2
    • /
    • pp.67-76
    • /
    • 1986
  • It is observed that an appreciable short-circuit current (Is) flows by the time variation of temperature without applying external field in M1(metal)-P(polymer)-M2(metal)system. In M1-P-M2(A1) system, Is flows in the direction from the electrode(A1) having a lower workfunction to the counter electrode(M1) during heating and its magnitude increases as the thickness of polymer is decreased and as the heating rate is raised. The sign of Is is reversed in lower temperature region (under glass transition temperature) when the direction of temerature variation is changed during heating and cooling. From these experimental results, we can sugest that Is flows in the external short-circuit during the space charge distribution formed around both interfacial surfaces (M1-P and P-M2) is continuously maintained in the non-equilibrium state but not in equilibrium state.

  • PDF

Effect of Ca on Droplet Transfer Phenomena in GMA Welding (GMAW 용적이행 현상에 미치는 Ca의 영향)

  • 안영호;방국수;이종봉;장내웅
    • Journal of Welding and Joining
    • /
    • v.12 no.4
    • /
    • pp.76-84
    • /
    • 1994
  • Droplet transfer modes due to welding conditions and the effect of Ca in welding wire on droplet transfer were investigated. Droplet transfer mode in CO$_{2}$ welding was classified into 2 modes, that is, short circuit and globular transfer, with increasing welding current and voltage. With increasing Ca content in wire, repulsive pressure due to vaporization of Ca was considerably increased. In short circuit transfer region, arcing time was increased and droplet transfer cycle was decreased, with increasing Ca content. In globular transfer region, welding condition for globular transfer was lower current region, with increasing Ca content.

  • PDF

The Cross Section Analysis CSA based on the Short Circuit Conditions of the Low Voltage Bare Wires (저압용 나전선의 단락조건에 의한 단면 분석)

  • Shong, Kil-Mok;Kim, Dong-Ook;Kim, Dong-Woo;Kim, Young-Seok;Choi, Chung-Seog
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.2094-2096
    • /
    • 2005
  • In this paper, we studied the cross section analysis based on the short circuit conditions of the low voltage bare wires. The copper wires prepared for the experiment were 1.2mm 1.6mm and 2.0mm in diameter. Through the cross section analysis(CSA), it was confirmed that the dendrite structure grew at the angle of about $40^{\circ}$ or $60^{\circ}$ when the fusing current was applied to the wires. The larger the fusing current is, the more decreased the growth angle of the dendrite structure is. It was confirmed that the dendrite structure was arranged like the columnar structure. In this paper, the characteristics analysis of short circuit was carried out in the range of transient duration.

  • PDF

Comparative Analysis on Current Limiting Characteristics of Hybrid Superconducting Fault Current Limiters (SFCLs) with First Half Cycle Limiting and Non-Limiting Operations

  • Kim, Jin-Seok;Lim, Sung-Hun;Kim, Jae-Chul
    • Journal of Electrical Engineering and Technology
    • /
    • v.7 no.5
    • /
    • pp.659-663
    • /
    • 2012
  • The application of large power transformer into a power distribution system was inevitable due to the increase of power demand and distributed generation. However, the decrease of the power transformer's impedance caused the short-circuit current of the power distribution system to be increase thus, the higher short-circuit current exceeded the cut-off ratings of the protective devices such as circuit breaker. To solve these problems, several countermeasures have been proposed to protect the power system effectively from higher fault current and the superconducting fault current limiter (SFCL) has been expected to be the promising countermeasure. In spite of excellent current limiting performances of the SFCL, on the other hand, the efforts to apply the SFCL into power system has been delayed due to both the limited spaces for the SFCL's installation and its long recovery time after the fault removal. In order to solve these problems, a hybrid SFCL, which can perform either first half cycle limiting of first half cycle non-limiting operation, has been developed by corporation of LSIS (LS Industrial System) and KEPCO (Korea Electric Power Corporation). In this paper, we tried to requirements hybrid SFCL by PSCAD/EMTDC. Simulation results of our analysis of the hybrid SFCL is that its accompanied the characteristics both the limit the fault current and quick recovery caused by the less impact from superconductor.

Current Source Type Pulse Generator with Improved Output Voltage Waveform for High Voltage Capacitively Coupled Plasma System (고전압 용량성 결합 플라즈마 시스템의 개선된 전압 파형 출력을 위한 펄스 전류 발생장치 회로)

  • Chae, Beomseok;Min, Juhwa;Suh, Yongsug;Kim, Hyunbae
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.24 no.3
    • /
    • pp.153-160
    • /
    • 2019
  • This study proposes a current source-type pulse generator to improve output voltage and current waveforms under a capacitively coupled plasma (CCP) system. The proposed circuit comprises two parallel-connected current source-type converters. These converters can satisfy the required output waveforms of plasma processing. The parallel-connected converters operate without reverse current fault by applying a time-delay control technique. Conventional voltage source converters based on pulse power supply exhibit drawbacks in short-circuit current, and problems occur when they are applied to a CCP system. The proposed pulse power supply based on a current source converter fundamentally solves the short-circuit current problem. Therefore, this topology can improve the voltage and current accuracy of a CCP system.

A Study on Fault Current Calculation of ±750[V] DC Distribution Grid (±750[V] 직류배전망의 고장전류 산정에 관한 연구)

  • Lee, Kyung-Min;Park, Chul-Won
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.10
    • /
    • pp.1286-1291
    • /
    • 2018
  • In recent years, the proliferation of DER (distributed energy resources) is progressing rapidly. In particular, research on LVDC distribution grid with various advantages has begun. In order to commercialize this LVDC grid, direct current protection method should be established by analysis of DC faults. Recently, the development of HSCB (high-speed circuit breaker) for new ${\pm}750[V]$ LVDC grid has been researched. This paper deals with the calculation of the maximum short-circuit fault current of the HSCB as a part of the development of HSCB for the LVDC distribution grid. First, modeling using PSCAD was carried out for PV array with BESS on the Gochang Power Test Center system. Next, to calculate the rated capacity of HSCB, fault currents were calculated and the characteristics were analyzed through fault simulations. Thus, this study results can help to establish short-circuit capacity calculation of HSCB and protection plan for DC protection relay system.

Research on the Influence of Inter-turn Short Circuit Fault on the Temperature Field of Permanent Magnet Synchronous Motor

  • Qiu, Hongbo;Yu, Wenfei;Tang, Bingxia;Yang, Cunxiang;Zhao, Haiyang
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.4
    • /
    • pp.1566-1574
    • /
    • 2017
  • When the inter-turn short circuit (ITSC) fault occurs, the distortion of the magnetic field is serious. The motor loss variations of each part are obvious, and the motor temperature field is also affected. In order to obtain the influence of the ITSC fault on the motor temperature distribution, firstly, the normal and the fault finite element models of the permanent magnet synchronous motor (PMSM) were established. The magnetic density distribution and the eddy current density distribution were analyzed, and the mechanism of loss change was revealed. The effects of different forms and degrees of the fault on the loss were obtained. Based on the loss analysis, the motor temperature field calculation model was established, and the motor temperature change considering the loop current was analyzed. The influence of the fault on the motor temperature distribution was revealed. The sensitivity factors that limit the motor continuous operation were obtained. Finally, the correctness of the simulation was verified by experiments. The conclusions obtained are of great significance for the fault and high temperature demagnetization of the permanent magnet analysis.