• 제목/요약/키워드: Sensor-type Measurement Technology

검색결과 213건 처리시간 0.023초

Development of Integration Pressure Sensor Using Piezoresistive Effect of Chemical Vapor Deposition (CVD) Produced Multilayer Graphene (CVD공정으로 제작된 멀티레이어 그래핀의 압저항 효과를 이용한 직접화된 압력센서 개발)

  • Dae-Yun Lim;Tae Won Ha;Chil-Hyoung Lee
    • Journal of Sensor Science and Technology
    • /
    • 제32권6호
    • /
    • pp.470-474
    • /
    • 2023
  • In this study, a diaphragm-type pressure sensor was developed using multi-layer(four-layer) graphene produced at 1 nm thickness by thermally transferring single-layer graphene produced by chemical vapor deposition (CVD) to a 6" silicon wafer. By measuring the gauge factor, we investigated whether it was possible to produce a pressure sensor of consistent quality. As a result of the measurement, the pressure sensor using multilayer graphene showed linearity and had a gauge factor of about 17.5. The gauge factor of the multilayer graphene-based pressure sensor produced through this study is lower than that of doped silicon, but is more sensitive than a general metal sensor, showing that it can be sufficiently used as a commercialized sensor.

Experimental Study on Non-contact Type Inspection System for Wing Rib Thickness Measurement (윙립 두께 측정용 비접촉식 검사 시스템에 관한 실험적 연구)

  • Lee, In-Su;Kim, Hae-Ji;Ahn, Myung-Sub
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • 제13권6호
    • /
    • pp.104-110
    • /
    • 2014
  • This paper presents a non-contact inspection system for automatically measuring the thickness of an aircraft wing rip product. In order to conduct the inspection of the wing rib thickness automatically, a non-contact laser displacement sensor, end-effector, and a robot were selected for use. The non-contact type inspection system was evaluated by measuring the measurement deviation of the rotation direction of a C-type yoke end-effector and the transfer direction of a V-slim end-effector. In addition, the non-contact inspection system for wing rib thickness measurements was validated through thickness measurements of a web, flange, and stiffener.

Excitation and Measurement Points Selection to Identify Structural Parameters for Model Tuning (모델보정을 위한 구조물 매개변수 규명시 가진점 .측정점의 선정)

  • Park, Nam-Gyu;Park, Yun-Sik
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • 제24권5호
    • /
    • pp.1271-1280
    • /
    • 2000
  • A sensor placement technique to identify structural parameter was developed. Experimental results must be acquired to identify unknown dynamic characteristics of a targeting structure for the comparison between analytical model and real structure. If the experimental environment was not equipped itself properly, it can be happened that some valuable information are distorted or ill-condition can be occurred. In this work the index to determine exciting points was derived from the criterion of maximizing parameter sensitivity matrix and that to choose measurement points was from that of preserving the invariant of sensitivity matrix. This idea was applied to a compressor hull structure to verify its performance. The result shows that the selection of measurement and excitation points using suggested criteria improve the ill-conditioning problem of inverse type problems such , as model updating.

A Study on the Design of a Planar Loop Sensor for Partial Discharge Diagnosis of 22.9 kV XLPE Power Cables

  • Lim, Kwang-Jin;Yang, Sang-Hyun;Shin, Dong-Hoon;Park, Noh-Joon;Park, Dae-Hee
    • Journal of Electrical Engineering and Technology
    • /
    • 제3권4호
    • /
    • pp.559-565
    • /
    • 2008
  • This study designed a new type of loop antenna that is able to detect partial discharges based on microstrip line technology. In the diagnosis of power cables, partial discharge signals are generally produced at a frequency range less than 100MHz because high frequency PD signals are lost along a propagation path in such cables. The new type of loop antenna sensor has been studied using simulation software known as CST microwave studio version 5.0. In partial discharge measurement experiments, a commercial HFCT sensor was used as a reference sensor. Several experiments were made over HFCT and loop antenna sensors for detecting partial discharges on 22.9kV MV XLPE cable. In this study, we showed the loop antenna designed in this study that can be applied as a commercial HFCT sensor.

Micro-scale Thermal Sensor Manufacturing and Verification for Measurement of Temperature on Wafer Surface

  • Kim, JunYoung;Jang, KyungMin;Joo, KangWo;Kim, KwangSun
    • Journal of the Semiconductor & Display Technology
    • /
    • 제12권4호
    • /
    • pp.39-44
    • /
    • 2013
  • In the semiconductor heat-treatment process, the temperature uniformity determines the film quality of a wafer. This film quality effects on the overall yield rate. The heat transfer of the wafer surface in the heat-treatment process equipment is occurred by convection and radiation complexly. Because of this, there is the nonlinearity between the wafer temperature and reactor. Therefore, the accurate prediction of temperature on the wafer surface is difficult without the direct measurement. The thermal camera and the T/C wafer are general ways to confirm the temperature uniformity on the heat-treatment process. As above ways have limit to measure the temperature in the precise domain under the micro-scale. In this study, we developed the thin film type temperature sensor using the MEMS technology to establish the system which can measure the temperature under the micro-scale. We combined the experiment and numerical analysis to verify and calibrate the system. Finally, we measured the temperature on the wafer surface on the semiconductor process using the developed system, and confirmed the temperature variation by comparison with the commercial T/C wafer.

A Compact Low-Power Shunt Proximity Touch Sensor and Readout for Haptic Function

  • Lee, Yong-Min;Lee, Kye-Shin;Jeong, Taikyeong
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제16권3호
    • /
    • pp.380-386
    • /
    • 2016
  • This paper presents a compact and low-power on-chip touch sensor and readout circuit using shunt proximity touch sensor and its design scheme. In the proposed touch sensor readout circuit, the touch panel condition depending on the proximity of the finger is directly converted into the corresponding voltage level without additional signal conditioning procedures. Furthermore, the additional circuitry including the comparator and the flip-flop does not consume any static current, which leads to a low-power design scheme. A new prototype touch sensor readout integrated circuit was fabricated using complementally metal oxide silicon (CMOS) $0.18{\mu}m$ technology with core area of $0.032mm^2$ and total current of $125{\mu}A$. Our measurement result shows that an actual 10.4 inches capacitive type touch screen panel (TSP) can detect the finger size from 0 to 1.52 mm, sharply.

Flow Velocity and Mass Measurement Sensor of Constant Temperature Type (정온도형 유속 및 유량 측정센서)

  • Park, Se-Kwang;Kim, Hyoung-Pyo
    • Journal of Sensor Science and Technology
    • /
    • 제1권1호
    • /
    • pp.35-41
    • /
    • 1992
  • A constant temperature type of flow sensor using a solid state micromachining technology was developed for measuring the velocity of gas or liquid. It was designed to detect only the heat convection related to flow velocity. Other heat transfer terms and common mode interferences are canceled by differentiating both reference and exposed flow sensor. It employs the principle that the change of current through the sensing element can be used to measure the flow velocity. An experimental study of the behavior on this flow sensor was performed in a narrow tube(diameter : 8mm) for city water. The relation between power consumption of the flow sensor and square-root of flow velocity is almost linear in the low velocity range(0-200 cm/sec).

  • PDF

Study on Development of Automation System for Non-Contact Counting of ID Card (비접촉 ID카드 계수를 위한 자동화 시스템 개발)

  • Kang, Dae-Hwa;Hong, Jun-Hee;Guo, Yang-Yang;Lee, Hyok-Won
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • 제22권4호
    • /
    • pp.652-657
    • /
    • 2013
  • In this study, we developed a counting method for non-contact ID cards using an optical fiber displacement sensor instead of the traditionally used friction counting method. The proposed method has the advantage of high speed and automated measurement. For counting non-contact ID cards, an H-type optical fiber sensor, jig part, and counting program are developed separately to build the system and adjust it. Through the experimental test results, it was confirmed that counting is possible with one type of international ID card and one type of financial security card based on ISO7810. Furthermore, by applying the proposed method to 100 ID cards 100 times repeatedly, it was confirmed that it has high accuracy and an error ratio of 0%. We experimentally demonstrated that the proposed counting method for non-contact ID cards using an optical fiber displacement sensor can perform measurements with high accuracy and high speed.

Disposable Strip-Type Biosensors for Amperometric Determination of Galactose

  • Gwon, Kihak;Lee, Seonhwa;Nam, Hakhyun;Shin, Jae Ho
    • Journal of Electrochemical Science and Technology
    • /
    • 제11권3호
    • /
    • pp.310-317
    • /
    • 2020
  • A development of disposable strip-type galactose sensor for point-of-care testing (POCT) was studied, which was constructed using screen-printed carbon electrodes. Galactose levels were determined by the redox reaction of galactose oxidase in the presence of potassium ferricyanide as an electron transfer mediator in a small sample volume (i.e., less than 1 µL). The optimal performance of biosensor was systematically designated by varying applied potential, operating pH, mediator concentration, and amount of enzyme on the electrode. The sensor system was identified as a highly active for the galactose measurement in terms of the sensitivity (slope = 4.76 ± 0.05 nA/µM) with high sensor-to-sensor reproducibility, the linearity (R2 = 0.9915 in galactose concentration range from 0 to 400 µM), and response time (t95% = <17 s). A lower applied potential (i.e., 0.25 V vs. Ag/AgCl) allowed to minimize interference from readily oxidizable metabolites such as ascorbic acid, acetaminophen, uric acid, and acetoacetic acid. The proposed galactose sensor represents a promising system with advantage for use in POCT.

Motion recognition LED lamp technology using infrared ray sensor

  • Zouhaier, Muhamud
    • Korean Journal of Artificial Intelligence
    • /
    • 제4권1호
    • /
    • pp.1-3
    • /
    • 2016
  • These days, citizens are interested in the energy. IT technology needs to develop and to make use of energy effectively and to save energy. In this study, motion recognition LED lamp was used to have good energy efficiency and to be made of environment friendly material. The purpose of development of the lamp was to add motion recognition to LED lamp. In this study, infrared ray sensor's distance measurement was used to develop LED lamp. Most of the lamps were used under dark environment, so that infrared ray sensor was used to perceive movement under dark environment. And, LED lamp with good efficiency and less power consumption was used to increase efficiency. Citizens were interested in perception of the movement to distinguish from conventional type of the lamps.