In this research, we proceeded with research on plasma resistance of the cleaning process of APS(Atmospheric Plasma Spray)-Y2O3 coated parts used for semiconductor and display plasma process equipment. CF4, O2, and Ar mixed gas were used for the plasma environment, and respective alconox, surfactant, and piranha solution was used for the cleaning process. After APS-Y2O3 was exposed to CF4 plasma, the surface changed from Y2O3 to YF3 and a large amount of carbon was deposited. For this reason, the plasma corrosion resistance was lowered and contamination particles were generated. We performed a cleaning process to remove the defect-inducing surface YF3 layer and carbon layer. Among three cleaning solutions, the piranha cleaning process had the highest detergency and the alconox cleaning process had the lowest detergency. Such results could be confirmed through the etching amount, morphology, composition, and accumulated contamination particle analysis results. Piranha cleaning process showed the highest detergency, but due to the very large thickness reduction, the base metal was exposed and a large number of contaminated particles were generated. In contrast, the surfactant cleaning process exhibit excellent properties in terms of surface detergency, etching amount, and accumulated contamination particle analysis.
최근 페로브스카이트 반도체 물질에 대한 연구가 이루어지고 있고, 이 물질에 대한 표면 처리를 이용한 특성 평가는 후속 연구들의 기반이 된다. 따라서, 본 논문에서는 상압분위기에서 플라즈마가 형성되는 상압플라즈마 장비로 산소 플라즈마를 생성하여 공기중에 약 6개월정도 노출시킨 페로브스카이트 박막을 표면 처리한 결과에 대해 연구하였다. 6개월간 노출시킨 이유는 페로브스카이트 박막은 유기물과 무기물로 이루어져 있기 때문에 공기 중에 노출되면, 산소나 수증기와의 반응을 통해 표면이 변화된다. 따라서, 이러한 변화를 원래 막으로의 복원이 가능한지 알아보기 위함이다. 산소플라즈마 분위기에서 1초부터 1200초까지 공정 시간을 변화시켜 가면서 표면 형상과 원소들 비율을 분석하였다. 이러한 결과는 페로브스카이트 막이 시간에 따라 변화가 일어나더라도 플라즈마 처리를 통해 이를 해결하는 방안을 제공한다.
Objectives: The aims of this study are to investigate how X-rays are emitted to surrounding parts during the ion implantation process, to analyze these emissions in relation to the properties of the ion implanter equipment, and to estimate the resulting exposure dose. Eight ion implanters equipped with high-voltage electrical systems were selected for this study. Methods: We monitored X-ray emissions at three locations outside of the ion implanters: the accelerator equipped with a high-voltage energy generator, the impurity ion source, and the beam line. We used a Personal Portable Dose Rate and Survey Meter to monitor real-time X-ray levels. The SX-2R probe, an X-ray Features probe designed for use with the RadiagemTM meter, was also utilized to monitor lower ranges of X-ray emissions. The counts per second (CPS) measured by the meter were estimated and then converted to a radiation dose (𝜇Sv/hr) based on a validated calibration graph between CPS and μGy/hr. Results: X-rays from seven ion implanters were consistently detected in high-voltage accelerator gaps, regardless of their proximity. X-rays specifically emanated from three ion implanters situated in the ion box gap and were also found in the beam lines of two ion implanters. The intensity of these X-rays did not show a clear pattern relative to the devices' age and electric properties, and notably, it decreased as the distance from the device increased. Conclusions: In conclusion, every gap, in which three components of the ion implanter devices were divided, was found to be insufficiently shielded against X-ray emissions, even though the exposure levels were not estimated to be higher than the threshold.
대나무 활성탄에 $TiO_2$의 코팅을 실시하여 이를 광촉매조건에서 16종의 주요 PAHs를 전처리하고 이를 PAHs 분해미생물에 의한 생분해과정에 적용하여 보다 효율적인 PAHs 처리 기술을 개발하고자 하였다. 대나무 활성탄에 anatase $TiO_2$의 성공적인 코팅이 가능하였으며 이를 이용한 메틸렌블루 용액의 광분해도 측정한 결과 $TiO_2$/AC 촉매가 첨가된 경우 가장 높은 촉매능을 보였다. PAHs 분해미생물이 없는 상태에서 naphthalene, acenaphthylene, acenaphthene 및 fluorene의 경우 각각 9.8, 76.2, 74.1 및 40.5%의 제거효율을 나타내었으나 고분자 PAHs는 $TiO_2$ 처리구에서 높은 잔류농도(400-1,000 ${\mu}g$/L)를 나타내었다. 한편 위의 전처리조건을 거친 후 분해미생물을 1주일간 처리할 경우 전반적인 PAHs가 340 ${\mu}g$/L 이하의 낮은 농도를 나타내었다. 여기서 phenanthrene, anthracene, fluoranthene 및 pyrene은 $TiO_2$의 처리구의 경우 대조구에 비해 각각 29.3, 61.4, 27.0 및 44.3%의 제거율을 나타내었다. $TiO_2$를 AC에 침착한 경우는 분해미생물이 AC 표면에 거의 생물막을 형성하지 못하는 모습이 관찰되었다. 따라서 $TiO_2$를 처리할 경우 분해미생물은 주로 부유상태(planktonic status)에서 PAHs를 분해하는 것으로 사료된다. 향후 보다 적절한 전처리조건을 확립할 경우 보다 효율적인 난분해성의 PAHs 처리기술의 개발이 가능할 것으로 전망된다.
현대의 반도체 산업에서 공정 중 가장 큰 비중을 차지하며, 가장 많은 자본과 인력을 소비하는 것이 바로 세정 공정이다. 세정공정은 소자의 작동에 영향을 미치고 기능을 저하시킬 수 있는 이물질 입자들을 제거하는 것이다. 특히 소자를 식각하기 위한 Photoresist(PR) 과정이 끝날 때마다 항상 세정 과정이 포함되어야 했다. 또한, Photoresist(PR) 공정 중 생성된 HDI-PR(high dose implanted photoresist)은 세정 과정에서 제거가 힘들기 때문에 현대의 고밀도 집적회로 세정 공정에서는 건식 세정과 습식 세정을 혼용하여 여러 단계의 세정 공정을 거치게 된다. 이 논문에서는 기존 플라즈마 방식으로 대표되는 건식 세정과 약액으로 대표되는 습식 세정을 동시에 사용하는 방식을 사용하여 약액활성화 방법(Plasma Liquid-Vapor Activation; PLVA)을 제안하여 실험을 실시하였고 HDI-PR을 활성화된 용액에 담근 후 Nano-Indenter를 이용하여 표면강도와 탄성계수를 측정했다. Nano-indenter는 특정한 기하학적 형태를 가지는 Tip을 표면에 압입한 후 압입하중과 압입깊이를 측정함으로서 시료의 표면강도와 탄성계수를 측정하였다. 그 결과 plasma로 활성화된 PR stripper 용액으로 strip한 후의 시료의 표면 강도가 크게 줄어든 것을 확인하였다. 이는 이후 물리적 표면 세정 공정을 후 공정으로 사용한다면 보다 효율적인 HDI-PR을 제거할 수 있을 것으로 사료된다.
다양한 전자부품에 활용되는 금속 잉크 기술은 전자부품산업의 주요 기술로 자리매김하였으며 이에 대한 연구 개발이 점차 증가하고 있다. 그 중에서 실버 잉크는 뛰어난 전도성과 안정성을 가지고 있어서 전자부품산업에 오랫동안 이용되어 왔으며 최근에는 입자 크기를 나노 크기로 분산시킨 실버 나노 잉크를 개발하여 디스플레이, 전자태그, 반도체와 연성회로 기판 등에 사용되는 전자소재로써 각광받고 있다. 그러나 이러한 전자산업기기의 첨단화는 제품의 생산량과 소비량을 증가시켜 제조 공정 중에 발생되는 환경오염 물질과 사용하고 버려지는 제품들에 의해 심각한 환경 문제를 가져올 것으로 예상된다. 따라서 본 연구에서는 습식환원법에 의해 제조된 실버나노 잉크의 제조 공정이 환경에 미치는 영향을 전과정평가(life cycle assessment, LCA) 기법을 이용하여 평가하였다. 전과정 평가 소프트웨어로는 GaBi 6를 사용하였고, 유관기관으로부터 받은 실버 나노 잉크의 제조 공정 데이터를 참고하여, 인벤토리를 구축하였으며 전과정목록분석(international organization for standardization, ISO) 14040, 14044 규격의 4단계에 걸쳐 LCA를 수행하였다.
첨단산업기술인 반도체, LCD 등 제조의 핵심공정인 클린룸은 생산제품의 성능 및 품질에 절대적인 영향을 미치는 가장 중요한 공정이다. 그러나 국내는 방화공학적인 측면에서 과학적이고 종합안전대책에 대한 체계적인 연구가 제대로 이루어지지 않고 있다. 본 연구는 LCD 제조공정 클린룸에 설치하는 제연시스템의 성능 및 문제점을 파악하여 이에 대한 개선방안을 도출하기 위하여 여러 시나리오를 고려한 화재시뮬레이션과 피난시뮬레이션을 통하여 분석하였다. LCD 제조공정의 클린룸 화재 및 연기확산에 대하여 분석한 결과 화재시 공조기의 연동정지는 반드시 필요하며 연기의 부력을 고려하여 FAB 상부에 배연을 할 수 있도록 하여야 한다. 또한 대규모 클린룸의 경우 화재특성상 스프링클러헤드의 집열 성능이 떨어지므로, 조기반응형 헤드의 설치 및 작동시간을 빠르게 하기 위한 보조장치를 설치하여야 한다. 특히, 대공간 클린룸은 자동화 공정으로 거주밀도가 낮지만, 복잡한 생산장비의 배치와 방진복을 착용하고 근무해야하는 환경특성 때문에 화재시 피난안전성능 확보가 어렵기 때문에 공정 내 위험요소의 철저한 관리 및 주기적인 교육과 훈련이 필요하며, 방재선진국의 기준에 준하는 수준의 국내 관련기술 기준을 정립할 필요가 있다.
The Electrostatic Charge Prevention Technology is a core factor that highly influences the yield of Ultra High Resolution Flat Panel Display and high-integrated semiconductor manufacturing processes. The corona or x-ray ionizations are commonly used in order to eliminate static charges during manufacturing processes. To develop such a revolutionary x-ray ionizer that is free of x-ray radiation and has function to control the volume of ion formation simultaneously is a goal of this research and it absolutely overcomes the current risks of x-ray ionization. Under the International Commission on Radiological Protection, it must have a leakage radiation level that should be lower than a recommended level that is $1{\mu}Sv/hour$. In this research, the new generation of x-ray ionizer can easily control both the volume of ion formation and the leakage radiation level at the same time. In the research, the test constraints were set and the descriptions are as below; First, In order not to leak x-ray radiation while testing, the shielding box was fully installed around the test equipment area. Second, Implement the metallic Ring Electrode along a tube window and applied zero to ${\pm}8kV$ with respect to manage the positive and negative ions formation. Lastly, the ion duty ratio was able to be controlled in different test set-ups along with a free x-ray leakage through the metallic Ring Electrode. In the result of experiment, the maximum x-ray radiation leakage was $0.2{\mu}Sv/h$. These outcome is lower than the ICRP 103 recommended value, which is $1{\mu}Sv/h$. When applying voltage to the metallic ring electrode, the positive decay time was 2.18s at the distance of 300 mm and its slope was 0.272. In addition, the negative decay time was 2.1s at the distance of 300 mm and its slope was 0.262. At the distance of 200 mm, the positive decay time was 2.29s and its slope was 0.286. The negative decay time was 2.35s and its slope was 0.293. At the distance of 100 mm, the positive decay time was 2.71s and its slope was 0.338. The negative decay time was 3.07s and its slope was 0.383. According to these research, the observation was shown that these new concept of ionizer is able to minimize the leakage radiation level and to control the positive and negative ion duty ratio while ionization.
TFT-LCD 산업은 반도체와 유사한 공정기술을 갖는 대규모 장치 산업으로 일종의 Giant Microelectronics 산업이다. 습식 에칭(Wet Etching)은 전체 TFT 공정에서 비교적 큰 비중을 차지하고 있지만 발표된 연구사례는 부족한 실정이다. 그 주요 원인은 반응이 일어나는 에칭액(Etchant) 성분이 기업의 비밀로 간주되어 외부에 발표되는 사례가 거의 없기 때문이다. 최근 대면적 LCD 제조를 위하여 사용되는 알루미늄(Al)과 구리(Cu)는 습식 에칭을 진행하기에 매우 까다로운 물질이다. 저 저항성 재료인 Cu는 습식 에칭 공정에서만 가능하며 높은 속도와 낮은 실패율, 적은 소비전력으로 Al 에칭 대용으로 사용하고 있다. 그리고 에칭액으로 사용하는 과산화수소($H_2O_2$)의 이상 반응으로 추가적인 배관 및 전기적인 안전장치가 필요하다. 본 논문에서는 과산화수소의 이상 반응을 제한하지는 못하나 이상 반응 발생 시 설비의 피해를 최소화 할 수 있는 방법을 제안한다. 또한 최근에 알루미늄 에칭설비에서 구리 에칭설비로 변경하는 사례가 많아 구리 에칭설비에 대한 하드웨어 인터록을 제안하고 안전 등급이 높은 안전 PLC로 구현하여 이상 반응에 대한 대비책을 강구하는 방안을 제안한다.
광학영상화검층은 광원과 CMOS 영상 센서를 이용하여 시추공벽을 이미지로 구현하는 물리검층 기술로 지하의 불연속면에 대한 여러 가지 원위치 정보를 고분해능으로 제공한다. 최근 시추공영상화검층은 지반침하 모니터링, 암반 무결성 평가, 응력으로 인한 단열 변화 탐지, 극지에서의 빙하 연대측정 등 그 활용범위가 매우 다양해졌다. 현재 국내외로 많이 이용되고 있는 시추공영상화검층 시스템은 장비 사양에 따라 한계점을 가지고 있어 적용 범위에 대한 검증과 여러 가지 시추공 환경에 대한 적절한 품질관리가 필요하다. 그러나 광학영상화검층의 자료로 도출되는 이미지는 원위치 정보로 정확도, 구현도, 신뢰성에 대한 검증에 직접적인 비교 확인이 어렵다. 본 논문에서는 신뢰성 있는 고품질 자료 취득 방법과 자료 처리 방법을 확인하기 위해 시추공 환경과 유사한 모듈화 된 균열모형시추공을 설계·제작하여 현재까지 보고되지 않은 실험에 대한 결과를 얻고자 하였다. 검출기 자기계 방향 확인의 정확성을 검증하고, 노출시간에 따른 색상의 구현도 및 균열의 분해능 관계, 정확한 간극 측정을 위한 자료 처리 방법 등을 제시하였다. 다양한 시추공 환경을 모사한 균열모형시추공 실험을 통해 고분해능의 신뢰성 높은 광학영상화검층의 자료 취득 및 해석이 가능할 것으로 기대된다.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.