• 제목/요약/키워드: Screw-in force

검색결과 239건 처리시간 0.023초

Additional Surgical Method Aimed to Increase Distractive Force during Occipitocervical Stabilization : Technical Note

  • Antar, Veysel;Turk, Okan
    • Journal of Korean Neurosurgical Society
    • /
    • 제61권2호
    • /
    • pp.277-281
    • /
    • 2018
  • Objective : Craniovertebral junctional anomalies constitute a technical challenge. Surgical opening of atlantoaxial joint region is a complex procedure especially in patients with nuchal deformity like basilar invagination. This region has actually very complicated anatomical and functional characteristics, including multiple joints providing extension, flexion, and wide rotation. In fact, it is also a bottleneck region where bones, neural structures, and blood vessels are located. Stabilization surgery regarding this region should consider the fact that the area exposes excessive and life-long stress due to complex movements and human posture. Therefore, all options should be considered for surgical stabilization, and they could be interchanged during the surgery, if required. Methods : A 53-year-old male patient applied to outpatients' clinic with complaints of head and neck pain persisting for a long time. Physical examination was normal except increased deep tendon reflexes. The patient was on long-term corticosteroid due to an allergic disease. Magnetic resonance imaging and computed tomography findings indicated basilar invagination and atlantoaxial dislocation.The patient underwent C0-C3-C4 (lateral mass) and additional C0-C2 (translaminar) stabilization surgery. Results : In routine practice, the sites where rods are bound to occipital plates were placed as paramedian. Instead, we inserted lateral mass screw to the sites where occipital screws were inserted on the occipital plate, thereby creating a site where extra rod could be bound.When C2 translaminar screw is inserted, screw caps remain on the median plane, which makes them difficult to bind to contralateral system. These bind directly to occipital plate without any connection from this region to the contralateral system.Advantages of this technique include easy insertion of C2 translaminar screws, presence of increased screw sizes, and exclusion of pullout forces onto the screw from neck movements. Another advantage of the technique is the median placement of the rod; i.e., thick part of the occipital bone is in alignment with axial loading. Conclusion : We believe that this technique, which could be easily performed as adjuvant to classical stabilization surgery with no need for special screw and rod, may improve distraction force in patients with low bone density.

치과 임플랜트 지대나사의 풀림 현상에 관한 연구 (A STUDY ON THE ABUTMENT SCREW LOOSENINE OF DENTAL IMPLANTS)

  • 강윤모;임주환;조인호
    • 대한치과보철학회지
    • /
    • 제34권1호
    • /
    • pp.1-14
    • /
    • 1996
  • Abutment screw loosening of dental implant is a major problem in the treatment of dental implant. The purpose of this study was to examine the effect on the prevention of screw loosening according to tightening method and using of washer. In the first experiment, using a implant fixture and precisely fabricated temporary cylinder, the loosening torque was measured by tightening the screw 5 times repeatedly. In the second experiment, the fabricated crown and implant fixture was tightened by the screw that is attatched washer and then the loosening torque was measured after loading it 1800, 12600 times under the force of 150N. The results were as follows. 1. The highest loosening torque appeared after tightening 3 times repeatedly(p<0.01). 2. When the washer was used, the loosening torque was increased significantly under the loading 1800 times(p<0.01), 3. When the washer was used, the loosening torque was increaed under the loading 12600 times, but it is statistically not significant(p<0.01). The first experiment results mean that 3 times repeated tightening screw is most effective clinically. The second results mean that washer is effective in prevention screw loosening, but the effect is decreased with increasing load.

  • PDF

치과용 임플란트 지대주 나사 구조에 관한 연구 (Characteristics of Abutment Screw Structure for Dental Implant)

  • 송종법;최일경;정효경;권순홍;권순구;박종민;김종순;정성원;최원식
    • 한국산업융합학회 논문집
    • /
    • 제20권2호
    • /
    • pp.169-176
    • /
    • 2017
  • Dental implants are required to have biomechanical functions and biostability in order to perform authoring, pronunciation, and aesthetic functions in the oral cavity. In terms of biostability, pure titanium for medical have good biostability and no rejection in the alveolar bone. with appropriate strength in terms of strength as well as biocompatibility. In recent years, various surgical methods and devices have been developed to improve the convenience and safety of the procedure. However, as the number of procedures increases, the screw loosening of the abutment screw connecting the artificial root and the abutment There are many reports of artificial root and abutment fracture. Fig. 1 is an example of a case where the upper part of the abutment screw is arbitrarily modified to remove the abutment by the abutment fracture due to the loosening of the abutment screw. The fundamental cause of abduction of the abutment screw is caused by the slight movement due to the lowering of the retention force of the abutment screw. It is necessary to minimize loosening of the abutment screw to avoid problems such as fracture during the period of using the implant. The purpose of this study is to investigate the structure of the abutment screw to prevent the loosening of the abutment screw by forming 0.5mm slot.

Extrusion Puffing of Pork Meat-Defatted Soy Flour-Corn Starch Blends to Produce Snack-like Products

  • Jennifer J. Jamora;Rhee, Ki-Soon;Rhee, Khee-Choon
    • Preventive Nutrition and Food Science
    • /
    • 제6권3호
    • /
    • pp.163-169
    • /
    • 2001
  • To produce expanded, minimally hard extrudates from blends of raw pork meat (20%), defatted soy flour (25%), and corn starch using a single-screw extruder, various combinations of feed moisture, process temperature, and screw speed were evaluated. First series of extrusion runs were conducted according to a central composite rotatable design/response surface methodology (RSM). Upon assessing the full model for each response, insignificant terms were eliminated to determine final response surface models. Screw speed within the range evaluated was found to have no significant effect on expansion ratio (ER) or shear force (SF) of extrudates. Since examinations of the response surfaces and their generated grids of predicted values indicated that maximum ER and minimum SF were likely to be attained with a moisture-temperature combination outside the RSM experimental range, the second series of extrusion runs were conducted with several selected combinations of moisture and temperature to determine a practical optimum extrusion condition. The combination of 22.78% feed moisture, 16$0^{\circ}C$ process temperature, and 170 rpm screw speed was chosen as such a condition, and used in the final extrusion. The final product required less force to break than did commercial pretzel sticks.

  • PDF

지대주와 고정체의 체결방법에 따른 임플란트의 풀림거동에 관한 연구 (Effect of connection type on the screw loosening of implant system)

  • 최재민;전흥재;한종현;이수홍
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.486-491
    • /
    • 2004
  • A comparative study on the implant screw loosening under the initial clamping force and cyclic loads was conducted. The experiments were performed to evaluate the screw loosening behavior of the internal and external implant systems. It was found that the screw loosening torques of implant systems were significantly affected by the way how the abutment and fixture were connected due to the difference in the load transfer mechanism between abutment and fixture.

  • PDF

힘 반향 원격제어 모의시험기 개발에 관한 연구 (On the Development of a Testbed for Force-Teflecting Teleoperation)

  • 김상범;최용제;김승호
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1997년도 한국자동제어학술회의논문집; 한국전력공사 서울연수원; 17-18 Oct. 1997
    • /
    • pp.1708-1713
    • /
    • 1997
  • In teleoperation of a manipulator, kinesthetic feedback can take an essential role in the sense that it provides an operator with more realistic information. In this paper, in order to implement the concept of kinesthetic feedback, force mapping algorithms based on screw theory have been presented. In the development of such algorithms, the virtual environment has been modeled usign a spring and dampers, and the forces caused by hitting the joint limits of a conrtolled manipulator were considered. Finally, some experimental results of force mapping algorithm have been presented.

  • PDF

탄소섬유/Epoxy 샌드위치 복합재판넬의 기계적 취부특성평가 (Properties of Mechanical Joint by Carbon Fiber/Epoxy Sandwich Composite Panels)

  • 오경원;이상진;정종철;조세현;김정석
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2005년도 춘계학술발표대회 논문집
    • /
    • pp.121-124
    • /
    • 2005
  • This paper was about experimental test properties by mechnical joint of CF1263/Epoxy Al honeycomb panels. In case of mechanical joint using screw, nut shall be secured over than minimize third screw pitch. In case of insert backsheet for increase of joint force, increase weight for assemble by screw pitch. In case of insert backsheet with CF1263/Epoxy, predominant save weight and minimazer of displacement by tensile weight moreover predominant strength. In case of mechanical joint by rivet, rivet of Monobolt has over-hole in hole of CF1263/Epoxy but rivet of PROTRUDING has predominant of mechanical joint.

  • PDF

VCR Drum 조립체의 고정나사 체결 Torque 결정에 관한 연구 (A Study on the determination of the initial torque in tightening set screw of the drum assembly in VCR)

  • 손영갑;김재중;백승준;장석원;유동수
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집A
    • /
    • pp.333-338
    • /
    • 2000
  • This paper presents an experimental study and numerical thermal deformation analysis in the home appliance, Video Cassette Recorder. Analyzing the change axial force of a set screw according to the change of temperature in the drum assembly, we can determine the initial torque in tightening set screw. The torque will have the preload boss not be separated from the bearing. Also we conduct the fundamental experiment to constitute a boundary condition of the numerical analysis. With the result of this study, we can change the material of preload boss, copper, for aluminum.

  • PDF

잠김 금속판(LCP-DF)을 이용한 대퇴골 원위부의 관절외 복합골절 치료시 나사못 배열에 따른 생체역학적 안정성 분석 (Effects of Screw Configuration on Biomechanical Stability during Extra-articular Complex Fracture Fixation of the Distal Femur Treated with Locking Compression Plate)

  • 권경제;조명래;오종건;이성재
    • 대한의용생체공학회:의공학회지
    • /
    • 제31권3호
    • /
    • pp.199-209
    • /
    • 2010
  • The locking compression plates-distal femur(LCP-DF) are being widely used for surgical management of the extra-articular complex fractures of the distal femur. They feature locking mechanism between the screws and the screw holes of the plate to provide stronger fixation force with less number of screws than conventional compression bone plate. However, their biomechanical efficacies are not fully understood, especially regarding the number of the screws inserted and their optimal configurations. In this study, we investigated effects of various screw configurations in the shaft and the condylar regions of the femur in relation to structural stability of LCP-DF system. For this purpose, a baseline 3-D finite element (FE) model of the femur was constructed from CT-scan images of a normal healthy male and was validated. The extra-articular complex fracture of the distal femur was made with a 4-cm defect. Surgical reduction with LCP-DF and bone screws were added laterally. To simulate various cases of post-op screw configurations, screws were inserted in the shaft (3~5 screws) and the condylar (4~6 screws) regions. Particular attention was paid at the shaft region where screws were inserted either in clustered or evenly-spaced fashion. Tied-contact conditions were assigned at the bone screws-plate whereas general contact condition was assumed at the interfaces between LCP-DF and bone screws. Axial compressive load of 1,610N(2.3 BW) was applied on the femoral head to reflect joint reaction force. An average of 5% increase in stiffness was found with increase in screw numbers (from 4 to 6) in the condylar region, as compared to negligible increase (less than 1%) at the shaft regardless of the number of screws inserted or its distribution, whether clustered or evenly-spaced. At the condylar region, screw insertion at the holes near the fracture interface and posterior locations contributed greater increase in stiffness (9~13%) than any other locations. Our results suggested that the screw insertion at the condylar region can be more effective than at the shaft during surgical treatment of fracture of the distal femur with LCP-DF. In addition, screw insertion at the holes close to the fracture interface should be accompanied to ensure better fracture healing.

DC 모터 전류 신호를 이용한 자동나사체결기 토크의 간접 측정 (Indirect Measurement of Torque of the Auto Screw Drive to using the Current Signals of DC Motor)

  • 이정윤;이정우;이준호
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2003년도 춘계학술대회 논문집
    • /
    • pp.299-304
    • /
    • 2003
  • This paper proposes an algorithm to estimate the screw torque from parameters of induction motor and current of DC motor without strain gage and torque cell. The parameters of friction torque search for damping ratio and electromotive force constant use the motor torque and angula speed signals be generated in the induction motor, make use of oscilloscope and stroboscope for precise measured of experimental data, measured physical parameters through experimental. In addition the screw torque estimated use of measured current signals from induction moor. The results, theory and simulation recognized well coincidence.

  • PDF