• Title/Summary/Keyword: Scan path

Search Result 97, Processing Time 0.032 seconds

Common-path Optical Coherence Tomography for Biomedical Imaging and Sensing

  • Kang, Jin-U.;Han, Jae-Ho;Liu, Xuan;Zhang, Kang
    • Journal of the Optical Society of Korea
    • /
    • v.14 no.1
    • /
    • pp.1-13
    • /
    • 2010
  • This paper describes a development of a fiber optic common-path optical coherence tomography (OCT) based imaging and guided system that possess ability to reliably identify optically transparent targets that are on the micron scale; ability to maintain a precise and safe position from the target; ability to provide spectroscopic imaging; ability to imaging biological target in 3-D. The system is based on a high resolution fiber optic Common-Path OCT (CP-OCT) that can be integrated into various mini-probes and tools. The system is capable of obtaining >70K A-scan per second with a resolution better than $3\;{\mu}m$. We have demonstrated that the system is capable of one-dimensional real-time depth tracking, tool motion limiting and motion compensation, oxygen-saturation level imaging, and high resolution 3-D images for various biomedical applications.

The Scan-Based BIST Architecture for Considering 2-Pattern Test (2-패턴 테스트를 고려한 스캔 기반 BIST 구조)

  • 손윤식;정정화
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.40 no.10
    • /
    • pp.45-51
    • /
    • 2003
  • In this paper, a scan-based low power BIST (Built-In Self-Test) architecture is proposed. The proposed architecture is based on STUMPS, which uses a LFSR (Linear Feedback Shift Register) as the test generator, a MISR(Multiple Input Shift Register) as the reponse compactor, and SRL(Shift Register Latch) channels as multiple scan paths. In the proposed BIST a degenerate MISR structure is used for every SRL channel; this offers reduced area overheads and has less impact on performance than the STUMPS techniques. The proposed BIST is designed to support both test-per-clock and test-per-scan techniques, and in test-per-scan the total power consumption of the circuit can be reduced dramatically by suppressing the effects of scan data on the circuits. Results of the experiments on ISCAS 89 benchmark circuits show that this architecture is also suitable for detecting path delay faults, when the hamming distance of the data in the SRL channel is considered.

Side-scan sonar survey in the Pechora Sea, Russian Arctic (북극 페초라해의 Side-scan Sonar 해저면 음향영상)

  • Jin, Young-Keun;Chung, Kyung-Ho;Kim, Yea-Dong;Lee, Joo-Han
    • Journal of the Korean Geophysical Society
    • /
    • v.8 no.4
    • /
    • pp.187-194
    • /
    • 2005
  • As a study of Arctic marine survey project, Side-scan sonar survey was carried out in the Pechora Sea belonging to the southeaster part of Barents Sea. The study area is a shallow sea 11 m-16 m deep with recent sediments of rich organic carbon. Side-scan sonar profiles show large-scale marine plant communities 2-3 m wide covering the southeastern area. A lot of lineaments are traced on the seafloor in the central and northern area. The major trends of the lineaments are 220°and 290°(WSW-ENE and WNW-ESE). This trends is thought to be a main path of icebergs. Pockmarks on the seafloor are locally distributed in the area, which are formed by fluid and/or gas discharge. These would be related with petroleum/gas system well developed around the study area. Dut to weak appearances and limited distribution of the pockmarks, more detailed studies are necessary to examine their nature and structure.

  • PDF

Fabrication of functionally customized fixed prosthesis in a hemimandibulectomy patient with fibular graft using double scan technique: A case report (비골이식을 받은 하악골절제술 환자에서 스캔중첩법을 이용한 기능적 고정성 보철물 제작: 증례 보고)

  • Win, Thaw Thaw;Lee, Du-Hyeong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.60 no.2
    • /
    • pp.195-201
    • /
    • 2022
  • Hemimandibulectomy and free fibular flap (FFF) in patients with squamous cell carcinoma could disturb the functional movement of the mandible. The muscular function in the sectioned side was compromised because of the incompetency of the muscle attachment to the mandible, leading to the unstable occlusal contact in the centric and eccentric occlusion. In this report, we present a case of a 63-year-old male who underwent cancer surgery and reconstruction with fibular graft, and he needed a fixed dental prosthesis to restore tooth loss in the anterior region. Occlusal contact change and instability were found according to the bite force in the centric relation and eccentric movement. This case report aimed to present the prosthetic procedure for fabricating the functionally optimized fixed prosthesis wherein the functionally generated path (FGP) technique and digital imaging method were applied to replicate mandibular movement and vertical dimension of the patient.

Spiral scanning imaging and quantitative calculation of the 3-dimensional screw-shaped bone-implant interface on micro-computed tomography

  • Choi, Jung-Yoo Chesaria;Choi, Cham Albert;Yeo, In-Sung Luke
    • Journal of Periodontal and Implant Science
    • /
    • v.48 no.4
    • /
    • pp.202-212
    • /
    • 2018
  • Purpose: Bone-to-implant contact (BIC) is difficult to measure on micro-computed tomography (CT) because of artifacts that hinder accurate differentiation of the bone and implant. This study presents an advanced algorithm for measuring BIC in micro-CT acquisitions using a spiral scanning technique, with improved differentiation of bone and implant materials. Methods: Five sandblasted, large-grit, acid-etched implants were used. Three implants were subjected to surface analysis, and 2 were inserted into a New Zealand white rabbit, with each tibia receiving 1 implant. The rabbit was sacrificed after 28 days. The en bloc specimens were subjected to spiral (SkyScan 1275, Bruker) and round (SkyScan 1172, SkyScan 1275) micro-CT scanning to evaluate differences in the images resulting from the different scanning techniques. The partial volume effect (PVE) was optimized as much as possible. BIC was measured with both round and spiral scanning on the SkyScan 1275, and the results were compared. Results: Compared with the round micro-CT scanning, the spiral scanning showed much clearer images. In addition, the PVE was optimized, which allowed accurate BIC measurements to be made. Round scanning on the SkyScan 1275 resulted in higher BIC measurements than spiral scanning on the same machine; however, the higher measurements on round scanning were confirmed to be false, and were found to be the result of artifacts in the void, rather than bone. Conclusions: The results of this study indicate that spiral scanning can reduce metal artifacts, thereby allowing clear differentiation of bone and implant. Moreover, the PVE, which is a factor that inevitably hinders accurate BIC measurements, was optimized through an advanced algorithm.

A Study on Design of Visual Sensor Using Scanning Beam for Shape Recognition of Weld Joint. (용접접합부의 형상계측을 위한 주사형 시각센서의 설계에 관한 연구)

  • 배강열
    • Journal of Welding and Joining
    • /
    • v.21 no.2
    • /
    • pp.102-110
    • /
    • 2003
  • A visual sensor consisted of polygonal mirror, laser, and CCD camera was proposed to measure the distance to the weld joint for recognizing the joint shape. To scan the laser beam of the sensor onto an object, 8-facet polygonal mirror was used as the rotating mirror. By locating the laser and the camera at axi-symmetrical positions around the mirror, the synchronized-scan condition could be satisfied even when the mirror was set to rotate through one direction continuously, which could remove the inertia effect of the conventional oscillating-mirror methods. The mathematical modelling of the proposed sensor with the optical triangulation method made it possible to derive the relation between the position of an image on the camera and the one of a laser light on the object. Through the geometrical simulation of the proposed sensor with the principal of reflection and virtual image, the optical path of a laser light could be predicted. The position and direction of the CCD camera were determined based on the Scheimpflug's condition to fit the focus of any image reflected from an object within the field of view. The results of modelling and simulation revealed that the proposed visual sensor could be used to recognize the weld joint and its vicinity located within the range of the field of view and the resolution. (Received February 19, 2003)

Cure depth control using photopolymerization inhibitor in microstereolithography and fabrication of three dimensional microstructures (액속주사법을 이용한 마이크로 광조형시 광폴리머에 대한 중합억제제의 영향분석 및 삼차원 미세구조물 제조)

  • 김성훈;주재영;정성호
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.714-719
    • /
    • 2004
  • Controlling the cure depth of the Fa1260T photopolymer enhances the quality of a microstructure and minimizes its size in microstereolithography. In this work, variation of cure depth of the Fa1260T photopolymer is investigated while the concentration of a photopolymerization inhibitor as a radical quencher was varied. The energy source inducing photopolymerization was a He-Cd laser and a motorized stage controled the laser beam path accurately. The effects of process variables such as laser beam power and scan speed on the cure depth were examined. Optimum conditions for the minimum cure depth were determined as laser power of 230 W and scan speed of 40-50 m/s at the concentration of the radical quencher of 5%. The minimum cure depth at the optimal condition was 14 m. The feasibility of the fabrication of microstructures such as a microcup, microfunnel, and microgrid of 100 m size is demonstrated using Super IH process.

  • PDF

A Study on Reducing Errors in Scanning Object and Registration using a Laser Scanner (레이저 스캐너를 이용한 측정 및 레지스트레이션시 오차감소에 관한 연구)

  • 홍성균;김연술;이희관;김형찬;양균의
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.20 no.9
    • /
    • pp.197-204
    • /
    • 2003
  • This study proposes a method to reduce errors in scanning object and registration using a laser scanner. The method consists of 3 stages. First, there is an error induced by the difference of the distance between the probe and the object. It is possible to reduce the error by planning a scanning strategy: object setting, scan path. Second, the scan data of the tooling ball affects calculating the tooling ball center. A z-direction compensation is given to calculate more accurate registration points. Third, three points are used to determine a coordinate transformation on each frame. The maximum error usually lies on the third tooling ball in the conventional merging method. LSM (Least Square Method) is applied to a coordinate transformation to reduce the registration error.

Fixed prosthodontic rehabilitation of maxillary posterior teeth using functionally generated path technique and intraoral digital scan: Case report (Functionally generated path technique 및 구내 디지털 스캔을 이용한 상악 구치부의 고정성 보철 수복 증례)

  • Kim, Sung-Ho;Lee, Jonghyuk;Choi, Yu-Sung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.58 no.3
    • /
    • pp.228-238
    • /
    • 2020
  • In order to deliver fixed partial denture to a patient successfully, dentist must take into many considerations beforehand. Patient's occlusal pattern should be fully understood before delivering any type of prosthesis, whether it's canine guidance or group function occlusion. In order to do so, movement of mandible should be recorded precisely. Introduced by Meyers in 1933, functionally generated path technique (FGP) has been successfully used to record mandibular movement with various materials, such as wax, and utilize it in fabricating precise prosthesis. In the following cases, patients showed secondary caries or endodontic-periodontic lesion on maxillary molars. Root canal treatment and subgingival curettage were done for each patient. Since the long term prognosis of each tooth was questionable, lateral force should be minimized. In order to do so, FGP technique was used to record mandibular movements precisely. Instead of using conventional plaster impression, intra-oral scanning of wax tracing was done to fabricate prosthesis efficiently. After delivery of fixed partial denture, favorable outcome was obtained.

Development and Sintering test of Industrial SFF system using SLS process (SLS 공정을 이용한 산업용 SFF 시스템의 개발 및 소결실험)

  • Jo, Hong-Seok;Cho, Hyun-Taek;Baek, Yung-Jong;Kim, Dong-Soo
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.1389-1393
    • /
    • 2007
  • Selective Laser Sintering (SLS) is currently recognized as a leading process in the new field of solid freeform fabrication (SFF). It is used to fabricate in a short time any 3 dimensional shapes by layer-by-layer sintering of polymer, ceramic or metal powder. To develop this SFF system, it needs effective laser scanning path, temperature and z-axis control for lamination. Therefore, in this study, through the application of control algorithm for sintering process have performed, temperature evaluation for sintering process has performed and the manufacturing sample using SLS process.

  • PDF