DOI QR코드

DOI QR Code

Fabrication of functionally customized fixed prosthesis in a hemimandibulectomy patient with fibular graft using double scan technique: A case report

비골이식을 받은 하악골절제술 환자에서 스캔중첩법을 이용한 기능적 고정성 보철물 제작: 증례 보고

  • Win, Thaw Thaw (Department of Prosthodontics, School of Dentistry, Kyungpook National University) ;
  • Lee, Du-Hyeong (Department of Prosthodontics, School of Dentistry, Kyungpook National University)
  • Received : 2021.10.25
  • Accepted : 2021.12.21
  • Published : 2022.04.30

Abstract

Hemimandibulectomy and free fibular flap (FFF) in patients with squamous cell carcinoma could disturb the functional movement of the mandible. The muscular function in the sectioned side was compromised because of the incompetency of the muscle attachment to the mandible, leading to the unstable occlusal contact in the centric and eccentric occlusion. In this report, we present a case of a 63-year-old male who underwent cancer surgery and reconstruction with fibular graft, and he needed a fixed dental prosthesis to restore tooth loss in the anterior region. Occlusal contact change and instability were found according to the bite force in the centric relation and eccentric movement. This case report aimed to present the prosthetic procedure for fabricating the functionally optimized fixed prosthesis wherein the functionally generated path (FGP) technique and digital imaging method were applied to replicate mandibular movement and vertical dimension of the patient.

편평세포암으로 하악골 절제술과 비골 피판 이식을 받은 경우 하악의 기능적 움직임이 저해될 수 있다. 하악골이 절제된 측은 근육부착의 소실로 인해 근기능이 약화되어 중심교합 및 편심교합에서 불안정한 교합접촉을 초래한다. 본 증례는 하악골절제술과 비골이식 재건술을 받은 63세 남성에서 전치부의 상실된 치아를 수복하기 위해 고정성 보철물이 필요했던 경우이다. 중심 및 편심교합에서 교합력의 크기에 따라 교합접촉 양상의 변화가 관찰되었다. Functionally generated path 기법과 디지털 영상기술을 적용하여 환자의 하악운동과 조화되고 적절한 수직고경이 있는 기능적으로 최적화된 고정성 보철물을 제작할 수 있었기에 보고하고자 한다.

Keywords

Acknowledgement

This work was supported by the Korea Medical Device Development Fund grant funded by the Korea government (the Ministry of Science and ICT, the Ministry of Trade, Industry and Energy, the Ministry of Health & Welfare, Republic of Korea, the Ministry of Food and Drug Safety) (202011A02).

References

  1. Zheng K, Liao Z, Yoda N, Fang J, Chen J, Zhang Z, Zhong J, Peck C, Sasaki K, Swain MV, Li Q. Investigation on masticatory muscular functionality following oral reconstruction - An inverse identification approach. J Biomech 2019;90:1-8. https://doi.org/10.1016/j.jbiomech.2019.04.007
  2. Schunke M, Schulte E, Schumacher U. Head and neck anatomy for dental medicine. Pap/Psc ed. New York; Thieme; 2010. p. 30-5.
  3. Parviz Janfaza, Joseph B. Nadol J, Robert Galla, Richard L. Fabian, William W. Montgomery. Surgical anatomy of the head and neck. 1st ed., Harvard University Press; 2011. p. 519-28.
  4. Curtis DA, Plesh O, Hannam AG, Sharma A, Curtis TA. Modeling of jaw biomechanics in the reconstructed mandibulectomy patient. J Prosthet Dent 1999;81:167-73. https://doi.org/10.1016/S0022-3913(99)70244-1
  5. Arce K, Waris S, Alexander AE, Ettinger KS. Novel patient-specific 3-dimensional printed fixation tray for mandibular reconstruction with fibular free flaps. J Oral Maxillofac Surg 2018;76:2211-9. https://doi.org/10.1016/j.joms.2018.04.028
  6. Serra JM, Paloma V, Mesa F, Ballesteros A. The vascularized fibula graft in mandibular reconstruction. J Oral Maxillofac Surg 1991;49:244-50. https://doi.org/10.1016/0278-2391(91)90213-6
  7. Marunick MT, Mathog RH. Mastication in patients treated for head and neck cancer: a pilot study. J Prosthet Dent 1990;63:566-73. https://doi.org/10.1016/0022-3913(90)90078-Q
  8. Marunick MT, Mathes BE, Klein BB. Masticatory function in hemimandibulectomy patients. J Oral Rehabil 1992;19:289-95. https://doi.org/10.1111/j.1365-2842.1992.tb01104.x
  9. Desjardins RP. Occlusal considerations for the partial mandibulectomy patient. J Prosthet Dent 1979;41:308-15. https://doi.org/10.1016/0022-3913(79)90014-3
  10. Stephen F. Rosenstiel MFL. Contemporary fixed prosthodontics. 5th ed., St. Louis, Missouri; Mosby; 2015. p. 37-49.
  11. DuVall NB, Rogers PM. Application of the functionally generated path technique to restore mandibular molars in bilateral group function occlusion. J Prosthodont 2013;22:226-32. https://doi.org/10.1111/j.1532-849X.2012.00944.x
  12. Meyer FS. The generated path technique in reconstruction dentistry: Part II. Fixed partial dentures. J Prosthet Dent 1959;9:432-40. https://doi.org/10.1016/0022-3913(59)90075-7
  13. Re GJ, Nelson SJ. Custom incisal guide table fabrication. J Prosthet Dent 1997;77:454. https://doi.org/10.1016/S0022-3913(97)70173-2
  14. Lo Russo L, Salamini A. Single-arch digital removable complete denture: a workflow that starts from the intraoral scan. J Prosthet Dent 2018;120:20-24. https://doi.org/10.1016/j.prosdent.2017.09.004
  15. Davidowitz G, Kotick PG. The use of CAD/CAM in dentistry. Dent Clin North Am 2011;55:559-70, ix. https://doi.org/10.1016/j.cden.2011.02.011
  16. Quaas S, Rudolph H, Luthardt RG. Direct mechanical data acquisition of dental impressions for the manufacturing of CAD/CAM restorations. J Dent 2007;35:903-8. https://doi.org/10.1016/j.jdent.2007.08.008
  17. Joo HS, Park SW, Yun KD, Lim HP. Complete-mouth rehabilitation using a 3D printing technique and the CAD/CAM double scanning method: a clinical report. J Prosthet Dent 2016;116:3-7. https://doi.org/10.1016/j.prosdent.2016.01.007
  18. Choi YD, Lee KE, Mai HN, Lee DH. Effects of scan body exposure and operator on the accuracy of image matching of implant impressions with scan bodies. J Prosthet Dent 2020;124:379.