• 제목/요약/키워드: Saving energy rate

검색결과 325건 처리시간 0.028초

가로수 조성 유형에 따른 비용편익 비교 분석 (Cost-Benefit Analysis for Planting Type of Street Trees)

  • 김준순;이동근
    • 한국환경복원기술학회지
    • /
    • 제17권6호
    • /
    • pp.29-37
    • /
    • 2014
  • The objective of this study is to estimate the cost and benefits of street trees for their planting types, specifically, single row, single row+bottom, double row, double row+bottom. Different planting types are compared and analyzed by using Net Present Value (NPV) and benefit-cost ratio (BCR). Existing data are collected from the literature reviews for the use of meta-analysis method for estimating cost and benefit. The elements for analyzing costs are management and planting costs, and benefits are air purification, energy saving and landscape view. The discount rate is applied at a minimum of 3% and a maximum of 5.5%. The unit used in this calculation is km/year. The result shows that the net benefit is highest in double row, followed by single row, double row+bottom, and single row+bottom. The BCR is the highest in double row, followed by single row, double row+bottom, and single row+bottom. The BCR reaches the break-even point from 9 to 17 years depending on the planting types.

pH와 탄소원이 Chlorella sorokiniana의 heterotrophic 배양 및 하폐수고도처리능에 미치는 영향 (Effects of pH on the growth, total nitrogen, total phosphorus and organic compound removal in heterotrophic culture of Chlorella sorokiniana applied wastewater treatment)

  • 박정은;조용범;장산;황선진
    • 상하수도학회지
    • /
    • 제27권6호
    • /
    • pp.703-709
    • /
    • 2013
  • Among many microalgae cultivation types, heterotrophic culture with low cost carbon sources and energy saving culture method is crucial. A result of estimating the effects of pH on wastewater treatment using heterotrophic growing microalgae Chlorella sorokiniana shows that there was no difference in microalgae growth amount and nitrogen, phosphorus removal rate by wide range of pH(5 ~ 9). From pH 5 to 9, total nitrogen, phosphorous and glucose removal rates were 10.5 mg-N/L/d, 2 mg-P/L/d, 800 ~ 1000 mg/L respectively. This study reveals that C. sorokiniana cannot metabolite glycerol heterotrophically, however, glucose and acetate were proper carbon sources for growth and T-N, T-P and TOC removal. This research highlights the potential of heterotrophic microalgal growth with wastewater treatment plant with wide range of pH and carbon sources.

순환골재의 강제 탄산화 개질 기술 개발을 위한 기초적 연구 (A Study on the Development of Forced Carbonation Reforming Technology for Recycled Aggregates)

  • 임명관;박원준;이혁;김도윤
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2016년도 춘계 학술논문 발표대회
    • /
    • pp.207-208
    • /
    • 2016
  • The most important things for the production of recycled aggregates are saving energy, suppressing the generation of by-product fine particles and sustaining the performance of concrete. As solutions, this study proposes this technology of improving the performance of recycled aggregates through forced carbonation.1) It is to stimulate and carbonate the bond paste part that causes the deterioration of recycled aggregates. Particularly, the purpose of this technology is to fill and chemically stabilize pores inside the bond paste, further improving the quality of recycled aggregates with a decreased absorption rate and an enhanced aggregate strength. Ultimately, it is possible to obtain a carbonation model, depending on the paste ratio and particle-size distribution of recycled aggregates. Moreover, by calculating the optimum carbonation period through the verification of this carbonation model, it is possible to examine how much the strength is improved by the reformation of recycled aggregated.

  • PDF

스위칭 엑티비티를 최소화한 저전력 DCT 아키텍쳐 구현 (Design and Implementation of Low-Power DCT Architecture by Minimizing Switching Activity)

  • 김산;박종수;이용주;이용석
    • 한국통신학회논문지
    • /
    • 제31권6C호
    • /
    • pp.603-613
    • /
    • 2006
  • 저전력 설계는 시스템의 소모전력을 줄임으로써 에너지 절약과 함께 휴대용 장치의 배터리 수명을 극대화시킴에 있어 직면한 가장 중요한 문제이다. 본 논문에서는 개량형 CSHM을 이용하여 저전력 DCT 구조를 제안하였다. 제안된 구조는 Computation Sharing Multiplication 연산 과정 중 불필요한 비트에 대한 연산을 수행하지 않는다. 실험 결과, 기존의 DCT 알고리즘과 동일한 연산 결과를 보이면서도 최대 약 9%의 소모전력이 감소하였다. 따라서 제안된 저전력 DCT 구조는 저전력 및 고성능으로 DCT 알고리즘을 처리해야하는 휴대용 멀티미디어 시스템에 적용이 가능하다.

공동주택 하이브리드(Hybrid) 환기시스템의 성능예측 (A Prediction of Hybrid Ventilation System Performance in Apartment House)

  • 황지현;오창용;최홍원;김무현
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2005년도 동계학술발표대회 논문집
    • /
    • pp.33-38
    • /
    • 2005
  • A hybrid ventilation system was introduced to predict the ventilation performance of the apartments. This ventilation system was composed of the natural supply-air inlet and the forced exhaust-air outlet. Analysis was conducted by CFD technique and was performed on three ventilating flow rates; 30, 60, 120 $m^3/h$. As the results, residents feel comfortable thermally and in air flow conditions for 60 $m^3/h$. But the case of 30 $m^3/h$ shows 1100ppm of $CO_2$ concentration due to the deficient of air flow rate. In the case of 120 $m^3/h$, however, residents feel uncomfortable thermally and in air currents. In this study the energy saving for space heating is also an important factor. A detailed prediction for more complicated whole apartment space will be investigated in the future.

  • PDF

골심지의 흡습제 함침에 의한 종이 재질 판형 전열교환 소자의 성능 향상 (Performance Improvement of a Paper Enthalpy Exchange Element by Impregnation of the Spacer)

  • 김내현
    • 설비공학논문집
    • /
    • 제29권3호
    • /
    • pp.142-147
    • /
    • 2017
  • Improvement of the enthalpy exchange element's energy efficiency is of current interest from anenergy-saving viewpoint. In this study, a LiCl-impregnated spacer was devised as a means to improve the performance of the enthalpy exchange element. Two samples were tested : one with and one without impregnated spacers of $338{\times}338{\times}380mm$ sizes with 2.0 mm channel spacing. The results showed that the temperature efficiencies of the two samples were approximately the same. The humidity efficiency, however, was strongly affected by the LiCl impregnation. The impregnated sample yielded a 9% higher humidity efficiency under cooling and the difference increased to 14% under aheating condition. It was anticipated that more moisture would beadsorbed on the LiCl-impregnated spacers, which was delivered to their roots and eventually to the air in neighboring channels. Separate moisture adsorption tests revealed that both the adsorption rate and the amount of the adsorbed moisture are higher for the LiCl-impregnated specimen.

LED통신기반 PC-PC 전송시스템 (LED Communication-based PC-PC Transmission System)

  • 심규성;리데덩;안병구;박인정
    • 한국인터넷방송통신학회논문지
    • /
    • 제12권1호
    • /
    • pp.181-187
    • /
    • 2012
  • LED는 빛을 내는 반도체 이다. 최근 친환경적 산업이 발전함에 따라 LED조명의 연구가 활발하게 진행되어 가고 있다. 특히 LED를 이용한 통신기법인 LED 통신에 대한 활발한 연구가 진행 중이다. 본 논문에서는 LED 통신을 이용한 PC-PC 전송시스템을 구현하였다. LED를 이용한 송신부 회로구성 및 PD와 OP-Amp를 이용한 수신부 회로를 구성하였다. 실험은 다음처럼 진행되었다. 송 수신부 양 끝단에 컴퓨터를 연결한 다음, 텍스트 전송프로그램을 이용하여 텍스트를 전송하였다. 이때 보드 레이트(baud rate), LED 색깔, 전송거리 등 다양한 변화를 주면서 실험을 진행하였다.

다기능온돌시스템을 이용한 자연환기성능 평가 (Evaluation of Natural Ventilation Performance using the Multi-Functional Floor Heating System)

  • 조동우;유기형;유정연;정해권
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2007년도 동계학술발표대회 논문집
    • /
    • pp.105-112
    • /
    • 2007
  • Recently developed raised floor heating system is not only capable of basic function to reduce noise between floors, but also is a multi-functional floor heating system enabling natural ventilation. The procedure of this system for natural ventilation is to import outdoor air through bottom space of the floor heating system, circulate indoor space and discharge it out of ceiling. In winter, powerless natural ventilation is possible with buoyancy effect caused by temperature difference between outdoor and indoor. And it also allows saving of energy by importing pre-heated air in bottom space of the floor heating system. To evaluate ventilation performance of this system, on-site measurement was conducted in 2 test laboratories, and the nominal air change rate was satisfied as 0.4$\sim$0.8 h-1 under the condition of outdoor temperature $5^{\circ}C{\sim}-5^{\circ}C$, which was evaluated as highly possible to be applied as a natural ventilation system in multi-family houses.

  • PDF

아파트의 전력부하밀도 및 전력소비 실태 분석 연구 (A Study on the Analysis of Power Load Density and Electric Power Consumption in Apartment Housing)

  • 이기홍;성세진
    • 조명전기설비학회논문지
    • /
    • 제15권1호
    • /
    • pp.118-124
    • /
    • 2001
  • 아파트에서의 전력수요예측과 에너지 절약을 유도하기 위하여 본 연구에서는 1,080아파트 단지의 전력소비실태를 설문조사하여 전력부하밀도, 전력소비량, 설비의 현황 등을 분석·제시하였다. 분석 결과 연면적 대비 전력 부하밀도는 최대 7.70[VA/m2], 평균 6.0[VA/m2] 등으로 분석되었으며, 평균 부하율은 64[%]인 것으로 나타났다. 그리고 전국 아파트에서 년간 소비되는 전력량은 국내 총 소비전력량의 7[%]에 해당되는 14,008[GWh/년]으로 분석되었다.

  • PDF

수중 음향 센서 망에서의 코드 분할 다중 접속 기법에 대한 성능 해석 (Performance Analysis on Code-Division Multiple Access in Underwater Acoustic Sensor Network)

  • 서보민;조호신
    • 한국통신학회논문지
    • /
    • 제35권9A호
    • /
    • pp.874-881
    • /
    • 2010
  • 수중 통신에서 사용되는 음향 신호의 감쇠는 노드 사이의 거리는 물론 사용 주파수 대역에도 크게 영향을 받는다. 또한 음향 신호는 긴 전송 지연을 가지므로 복잡한 절차와 많은 제어 메시지를 필요로 하는 매체 접속 기법은 사용하기에 적합하지 않다. 본 논문은 이처럼 열악한 수중 환경에서 코드 분할 다중 접속 기법의 적용 방법을 제시하고 그 성능을 분석한다. 수중 음향 센서망 구조는 데이터 수집형 트리 구조를 가정하며 에너지 절약을 위해 트리 구조에서 계층간 엇갈림 깨어남 패턴을 사용한다. 성능 분석을 위해 다양한 사용 주파수 대역에서 계층별 데이터 전송률을 수학적으로 도출한다.