• Title/Summary/Keyword: Sampling Device

Search Result 273, Processing Time 0.029 seconds

Analysis of 12 chlorophenols in waste-water using automated liquid phase microextracion (LPME) device (자동화된 Liquid Phase Microextraction(LPME)를 이용한 폐수 중 12종의 클로로페놀 분석)

  • Kim, Seok-Jung;Cho, Hyun-Woo;Myung, Seung-Woon
    • Analytical Science and Technology
    • /
    • v.20 no.1
    • /
    • pp.70-77
    • /
    • 2007
  • Twelve chlorophenols (CPs) were extracted by liquid phase microextraction (LPME) from the industrial waste-water and analyzed by GC/MS. To establish the optimal conditions, species of extraction solvent, sample amount, pH of sample, salting out effect, a number of sampling and plunger movement speed were investigated. As a result, the linearities of calibaration curves ranged from 0.9913 to 0.9999, while LODs and LOQs were from 0.05 to 10.0 ng/mL except 2,3,4,5-tetrachlorophenol and pentachlorophenol. Using this method, 4-chloro-3-methylphenol confirmed from waste water at the concentration of 784 ng/mL. The method can be applicable to detect chlorophenols from industrial waste-water.

A 10b 25MS/s $0.8mm^2$ 4.8mW 0.13um CMOS ADC for Digital Multimedia Broadcasting applications (DMB 응용을 위한 10b 25MS/s $0.8mm^2$ 4.8mW 0.13um CMOS A/D 변환기)

  • Cho, Young-Jae;Kim, Yong-Woo;Lee, Seung-Hoon
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.43 no.11 s.353
    • /
    • pp.37-47
    • /
    • 2006
  • This work proposes a 10b 25MS/s $0.8mm^2$ 4.8mW 0.13um CMOS A/D Converter (ADC) for high-performance wireless communication systems such as DVB, DAB and DMB simultaneously requiring low voltage, low power, and small area. A two-stage pipeline architecture minimizes the overall chip area and power dissipation of the proposed ADC at the target resolution and sampling rate while switched-bias power reduction techniques reduce the power consumption of analog amplifiers. A low-power sample-and-hold amplifier maintains 10b resolution for input frequencies up to 60MHz based on a single-stage amplifier and nominal CMOS sampling switches using low threshold-voltage transistors. A signal insensitive 3-D fully symmetric layout reduces the capacitor and device mismatch of a multiplying D/A converter while low-noise reference currents and voltages are implemented on chip with optional off-chip voltage references. The employed down-sampling clock signal selects the sampling rate of 25MS/s or 10MS/s with a reduced power depending on applications. The prototype ADC in a 0.13um 1P8M CMOS technology demonstrates the measured DNL and INL within 0.42LSB and 0.91LSB and shows a maximum SNDR and SFDR of 56dB and 65dB at all sampling frequencies up to 2SMS/s, respectively. The ADC with an active die area if $0.8mm^2$ consumes 4.8mW at 25MS/s and 2.4mW at 10MS/s at a 1.2V supply.

Adaptation of Intravenous Infusion Nursing Practice Guideline (정맥주입요법 간호실무지침 수용개작)

  • Gu, Mee Ock;Cho, YoungAe;Cho, Myung Sook;Eun, Young;Jeong, Jae Sim;Jung, Ihn Sook;Lee, Young Geun;Kim, Mi Kyung;Kim, Eun Hyun;Kim, Ji Haei;Lee, Sun Hee;Kim, Hyun Lim;Yun, Hee Sook
    • Journal of Korean Clinical Nursing Research
    • /
    • v.19 no.1
    • /
    • pp.128-142
    • /
    • 2013
  • Purpose: This study was conducted to adapt the previously developed intravenous infusion guidelines with good quality for development of the evidence-based intravenous infusion nursing practice guideline in Korea. Methods: Guideline adaptation process was conducted according to guideline adaptation manual version 2.0 developed by NECA (Kim, Kim et al., 2011) which consisted of three main phases, 9 modules including a total of 24 steps. Results: Adapted intravenous infusion nursing practice guideline was consisted of 19 domains and 180 recommendations. The domains and number of recommendations in each domain were: general guide, 4; assessment, 1; vascular access device selection, 4;site selection, 14;site preparation, 5;site care, 29; maintaining patency, 11; blood sampling via vascular access, 4; vascular access device exchange and removal, 9; add-on device selection, 27; infusion related complications, 63; education, 7; and documentation and report, 2. There were 11.9% of A, 28.4% of B, 58.7% of C in grade of recommendations. Conclusion: Adapted intravenous infusion nursing practice guideline is expected to contribute providing an evidence based practice guides for intravenous infusion. The guideline is recommended to be disseminated to nurses nationwide to improve the efficiency of intravenous infusion practice.

Stability of Haptic System with consideration for Sample-and-Hold Methods and Properties of Haptic Device (샘플-홀드 방식과 햅틱 장치 물성치에 따른 햅틱 시스템의 안정성 분석)

  • Lee, Kyungno
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.11
    • /
    • pp.5338-5343
    • /
    • 2013
  • In a haptic system, a virtual wall is modeled as a virtual spring. The larger the stiffness of the virtual spring is, the more improved the reality of the virtual wall is, but the more unstable the haptic system becomes. This paper shows how to increase the stiffness of the virtual spring while the stability of the haptic system is guaranteed and shows the effects of a mass (Md) and a damper (Bd) of a haptic device on the stability when first-order hold method is applied and a virtual wall is modeled as a virtual spring (Kw). The simulation results show the boundary of the virtual spring is proportional to the square root of the mass (Md) and the damper (Bd) while maintaining the stability. The relation among the virtual spring (Kw), the mass (Md) and the damper (Bd) of the haptic device, and sampling time (T) is inferred as $K_w{\leq}{1.611M_d}^{0.50}{B_d}^{0.50}T^{-1.51}$, by using the simulation results. The maximum available stiffness of the virtual spring in first-order hold method is larger than in zero-order hold method. So the reality of the virtual wall can be improved.

Development of Multi-channel Detector of X-ray Backscatter Imaging (후방산란 엑스선 영상획득을 위한 다채널 검출기 개발)

  • Lee, Jeonghee;Park, Jongwon;Choi, Yungchul;Lim, Chang Hwy;Lee, Sangheon;Park, Jaeheung
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2022.10a
    • /
    • pp.245-247
    • /
    • 2022
  • Backscattered x-ray imaging is a technology capable of acquiring an image inside an irradiated object by measuring X-rays scattered from an object. For image acquisition, the system must include an X-ray generator and a detection system for measuring scattered x-rays. The imaging device must acquire a real-time signal at sampling intervals for x-rays generated by passing through a high-speed rotating collimator, and for this purpose, a high-speed signal acquisition device is required. We developed a high-speed multi-channel signal acquisition device for converting and transmitting signals generated by the sensor unit composed of a large-area plastic scintillator and a photomultiplier tube. The developed detector is a system capable of acquiring signals at intervals of at least 15u seconds and converting and transmitting signals of up to 6 channels. And a system includes remote control functions such as high voltage, signal gain, and low level discrimination for individual calibration of each sensor. Currently, we are conducting an application test for image acquisition under various conditions.

  • PDF

A 12b 200KHz 0.52mA $0.47mm^2$ Algorithmic A/D Converter for MEMS Applications (마이크로 전자 기계 시스템 응용을 위한 12비트 200KHz 0.52mA $0.47mm^2$ 알고리즈믹 A/D 변환기)

  • Kim, Young-Ju;Chae, Hee-Sung;Koo, Yong-Seo;Lim, Shin-Il;Lee, Seung-Hoon
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.43 no.11 s.353
    • /
    • pp.48-57
    • /
    • 2006
  • This work describes a 12b 200KHz 0.52mA $0.47mm^2$ algorithmic ADC for sensor applications such as motor controls, 3-phase power controls, and CMOS image sensors simultaneously requiring ultra-low power and small size. The proposed ADC is based on the conventional algorithmic architecture with recycling techniques to optimize sampling rate, resolution, chip area, and power consumption. The input SHA with eight input channels for high integration employs a folded-cascode architecture to achieve a required DC gain and a sufficient phase margin. A signal insensitive 3-D fully symmetrical layout with critical signal lines shielded reduces the capacitor and device mismatch of the MDAC. The improved switched bias power-reduction techniques reduce the power consumption of analog amplifiers. Current and voltage references are integrated on the chip with optional off-chip voltage references for low glitch noise. The employed down-sampling clock signal selects the sampling rate of 200KS/s or 10KS/s with a reduced power depending on applications. The prototype ADC in a 0.18um n-well 1P6M CMOS technology demonstrates the measured DNL and INL within 0.76LSB and 2.47LSB. The ADC shows a maximum SNDR and SFDR of 55dB and 70dB at all sampling frequencies up to 200KS/s, respectively. The active die area is $0.47mm^2$ and the chip consumes 0.94mW at 200KS/s and 0.63mW at 10KS/s at a 1.8V supply.

A 10b 100 MSample/s $1.4\;mm^2$ 56 mW 0.18 urn CMOS A/D Converter for Low-Power Multimedia Applications (저전력 멀티미디어 응용을 위한 10b 100 MSample/s $1.4\;mm^2$ 56 mW 0.18 um CMOS A/D 변환기)

  • Min Byoung-Han;Park Hee-Won;Chae Hee-Sung;Sa Doo-Hwan;Lee Seung-Hoon
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.42 no.12
    • /
    • pp.53-60
    • /
    • 2005
  • This work proposes a 10b 100 MS/s $1.4\;mm^2$ CMOS ADC for low-power multimedia applications. The proposed two-step pipeline ADC minimizes chip area and power dissipation at the target resolution and sampling rate. The wide-band SHA employs a gate-bootstrapping circuit to handle both single-ended and differential inputs with 1.2 Vp-p at 10b accuracy while the second-stage flash ADC employs open-loop offset sampling techniques to achieve 6b resolution. A 3-D fully symmetrical layout reduces the capacitor and device mismatch of the first-stage MDAC. The low-noise references are integrated on chip with optional off-chip voltage references. The prototype 10b ADC implemented in a 0.18 um CMOS shows the maximum measured DNL and INL of 0.59 LSB and 0.77 LSB, respectively. The ADC demonstrates the SNDR of 54 dB, the SFDR of 62 dB, and the power dissipation of 56 mW at 100 MS/s.

A Study on the Quantitative Measurement of Oil Carry-over in Natural Gas Vehicle fueling Station Using A Gravimetric Method (무게측정법을 이용한 천연가스 자동차 충전소 오일전이 정량 분석에 대한 연구)

  • Hwang, Sung-Soo;Oh, Jun-Seok;Kim, Ki-Dong;Oh, Young-Sam;Choi, Kyung-Sik;Kim, Hack-Eun
    • Journal of the Korean Institute of Gas
    • /
    • v.19 no.1
    • /
    • pp.12-17
    • /
    • 2015
  • The core of the CNG fueling station is the compressor and most of CNG compressors in Korea require lubrication. Lubrication oil of CNG compressor that can be transferred into the pressure regulators and the engines of fueling system can cause a negative effect on NGV(Nature Gas Vehicle) performance during refueling due to oil Carry-over. In order to avoid the problem, it is necessary to enhance the quality of the compressed natural gas by measuring quantitatively the amount of the transferred oil. In this research, a sampling device and sampling tube were developed, which can be used with a gravimetric method of detection to measure CNG oil Carry-over. In addition, CNG samples were taken at 6 pre-selected CNG fueling stations and analysed for their trace oil Carry-over. The measured total oil Carry-over ranged from 2.569 to 6.509 ppm. This test measurements were compared with those of previous studies to verify the results.

Effect of field location and spray device on pesticide residue in chilli peppers (농약 살포조건이 고추열매 중 잔류에 미치는 영향)

  • Son, Kyeong-Ae;Kang, Tae-Kyeong;Park, Byeong-Jun;Kim, Taek-Kyum;Gil, Geun-Hwan;Kim, Chan-Sub;Kim, Jin-Bae;Im, Geon-Jae;Lee, Key-Woon
    • The Korean Journal of Pesticide Science
    • /
    • v.16 no.3
    • /
    • pp.230-235
    • /
    • 2012
  • This study was carried out to clarify effects of field location and sprayer on the level of pesticide residue in chilli peppers. As confirmed by statistical analysis, the residue levels in green pepper among three greenhouses did not show significant difference at the first day after spraying with the same engine sprayer and nozzle. But the residue levels in green peppers collected from the exposed outside of crop were 2 times higher than those from the hidden inside. The sampling site was one of variation elements of pesticide residue. The residue levels after application by knapsack engine powered sprayer were 1.7 times higher than those by manual compressed sprayer. As the spraying pressure of the engine power sprayer is 2 times higher than the commonly used pressure of the manual compressed sprayer, the pressure of the sprayer and nozzles were considered to affect on the residue levels in peppers.

Characteristics of Heavy Metals in the Industrial Complex Area of Pocheon City (포천시 공단지역 미세먼지 중 중금속농도 특성)

  • Shin, Hyung-Soon;Jung, Yeon-Hoon;Kim, Jin-gil;Jung, Jong-Pil;Lee, Sang-Soo;You, Han-Jo;Oh, Jo-Kyo
    • Journal of Environmental Health Sciences
    • /
    • v.45 no.6
    • /
    • pp.577-582
    • /
    • 2019
  • Objectives: The purpose of this survey was to assess the concentrations of heavy metals in the atmosphere of Pocheon City by measuring heavy metals in the industrial complex area and at the city air measuring station, and also to assess the degree of impact that the industrial area has on urban air quality. Methods: Sampling was carried out between February 2018 and November 2018 at two sites in the industrial complex and in the city air monitoring stations. Results: At the industrial complex in Pocheon City, air pollutant emitting businesses were emitting concentrations of fine dust (PM10) between 45 and 60 ㎍/㎥ higher than in the city air. The daily maximum concentrations of lead (Pb), manganese (Mn), and cadmium (Cd) in the industrial complex are below the WHO recommendation standard (annual average), and the impact on the urban atmosphere is judged to be insignificant. Three to five percent of fine dust (PM10) consists of metallic materials, and as the fine dust increased, metals were detected proportionally. Although cadmium (Cd) and beryllium (Be) were not detected in the city air in Pocheon and chromium (Cr), copper (Cu), and arsenic (As) were found to be 50 percent or less, it is deemed that copper (Cu) was detected at unusually high levels due to unknown air pollutants, which requires regular heavy metal measurement and cause verification. Conclusions: An analysis of the heavy metals in the industrial zone and the urban atmosphere in Pocheon City in this study showed that the linear relationship of heavy metals in the industrial zone, or the direct impact relationship, on the heavy metals in the urban atmosphere could not be estimated. The sampling device for equivalent assessment of particulate matter installed at air pollution monitoring stations is highly likely to be used for analysis of fine dust and heavy metals.