• 제목/요약/키워드: Sample testing

검색결과 986건 처리시간 0.027초

A Moment Inequality on New Renewal Better Than Used in Expectation Class of Life Distributions with Hypothesis Testing Application

  • Abu-Youssef, S.E.
    • International Journal of Reliability and Applications
    • /
    • 제4권4호
    • /
    • pp.191-199
    • /
    • 2003
  • In the present work, a moment inequality is derived for new renewal better (worse) than used in expectation(NRBUE) (NRWUE) distributions. This inequality demonstrates that if the mean life is finite then all higher order moments exist. A new test statistics for testing exponentiality against NRBUE (NRWUE) is introduced based on this inequality. It is shown that the proposed test is simple and has high relative efficiency for some commonly used alternatives. Critical values are tabulated for sample sizes n = 5(1)30. A set of real data is used as an example to elucidate the use of the proposed test statistics for practical reliability analysis.

  • PDF

LDL Cholesterol Testing Device using Serial Reflected Face-to-Face Mirror System

  • Choi, Min-Seong;Yoo, Jae-Chern
    • Journal of the Optical Society of Korea
    • /
    • 제17권4호
    • /
    • pp.296-299
    • /
    • 2013
  • A low density lipoprotein (LDL) cholesterol testing device, structured with serial reflected face-to-face mirror (SRM) allowing spectrophotometry measurements, is presented. The spectrophotometry has been employed to measure the amount of light that a sample absorbs, but it generally should have had path length longer than 10 mm to secure enough sensitivity. Such requirement of path length has often been problematic in implementing a thin type of lab on a disc (LOD). We developed the SRM system which was implemented in a detection chamber with 1.4mm thickness, providing path length longer than 10mm, and thus straightforwardly being applicable to LOD as thin as a compact disc. The experimental results show that the SRM system gives not only a much thinner design compared to the conventional spectrophotometry-based LOD but also a comparable performance to already commercialized spectrometers.

Modified information criterion for testing changes in generalized lambda distribution model based on confidence distribution

  • Ratnasingam, Suthakaran;Buzaianu, Elena;Ning, Wei
    • Communications for Statistical Applications and Methods
    • /
    • 제29권3호
    • /
    • pp.301-317
    • /
    • 2022
  • In this paper, we propose a change point detection procedure based on the modified information criterion in a generalized lambda distribution (GLD) model. Simulations are conducted to obtain empirical critical values of the proposed test statistic. We have also conducted simulations to evaluate the performance of the proposed methods comparing to the log-likelihood method in terms of power, coverage probability, and confidence sets. Our results indicate that, under various conditions, the proposed method modified information criterion (MIC) approach shows good finite sample properties. Furthermore, we propose a new goodness-of-fit testing procedure based on the energy distance to evaluate the asymptotic null distribution of our test statistic. Two real data applications are provided to illustrate the use of the proposed method.

모형명세화 오류와 소표본에서 구조방정식모형 모수추정 방법들 비교: 모수추정 정확도와 이론모형 검정력을 중심으로 (A study on the performance of three methods of estimation in SEM under conditions of misspecification and small sample sizes)

  • 서동기;정선호
    • Journal of the Korean Data and Information Science Society
    • /
    • 제28권5호
    • /
    • pp.1153-1165
    • /
    • 2017
  • 구조방정식모형은 사회과학 및 행동과학 연구 분야에서 이론검정을 위해 주로 사용되는 통계방법이다. 최근 이 통계기법에 대한 방법론적 이슈로서 모형명세화 오류와 소표본 문제가 부각되고 있다. 그런데 이 문제들이 구조방정식모형의 대표 추정 방법인 최대우도법에 위한 이론검정에 어떤 영향을 주는지에 대해 여전히 명확하지 않다. 따라서 본 연구에서 최대우도법 그러고 이에 대한 대안으로 개발된 2단계최소자승법과 2단계능형최소자승법을 정확도와 검정력 관점에서 시뮬레이션을 통해 체계적으로 비교해 본다. 이 실험 결과에 따르면, 모형이 정확하게 설정된 경우, 정확도 기준에서 추정방법들 간의 차이는 미미했다. 하지만 모형오류가 발생한 경우, 2단계능형최소자승법은 다른 방법들보다 표본 크기가 작을 때 훨씬 더 정확한 모수추정치를 산출해 내었다. 그러고 이 방법은 명세화 오류에 관계없이 표본 크기가 작을 때에도 제 2종 오류 (Type II error) 수준이 상대적으로 작거나 만족할만한 수준의 검정력을 보여주었다. 이에 반해 다른 두 방법들은 표본이 작은 경우 또는 명세화 오류가 있는 경우 상당히 높은 수준의 제 2종 오류를 나타내었다.

추백리-가금티푸스의 혈청학적 모니터링 계획수립을 위한 표본크기 (Determination of sample size to serological surveillance plan for pullorum disease and fowl typhoid)

  • 박선일;박최규
    • 대한수의학회지
    • /
    • 제48권4호
    • /
    • pp.457-462
    • /
    • 2008
  • The objective of this study was to determine appropriate sample size that simulated different assumptions for diagnostic test characteristics and true prevalences when designing serological surveillance plan for pullorum disease and fowl typhoid in domestic poultry production. The number of flocks and total number of chickens to be sampled was obtained to provide 95% confidence of detecting at least one infected flock, taking imperfect diagnostic tests into account. Due to lack of reliable data, within infected flock prevalence (WFP) was assumed to follow minimum 1%, most likely 5% and maximum 9% and true flock prevalence of 0.1%, 0.5% and 1% in order. Sensitivity were modeled using the Pert distribution: minimum 75%, most likely 80% and maximum 90% for plate agglutination test and 80%, 85%, and 90% for ELISA test. Similarly, the specificity was modeled 85%, 90%, 95% for plate agglutination test and 90%, 95%, 99% for ELISA test. In accordance with the current regulation, flock-level test characteristics calculated assuming that 30 samples are taken from per flock. The model showed that the current 112,000 annual number of testing plan which is based on random selection of flocks is far beyond the sample size estimated in this study. The sample size was further reduced with increased sensitivity and specificity of the test and decreased WFP. The effect of increasing samples per flock on total sample size to be sampled and optimal combination of sensitivity and specificity of the test for the purpose of the surveillance is discussed regarding cost.

닭 전염성 기관지염 바이러스의 혈청 유병률 연구에서 개별혈청과 합병혈청의 비교 (Comparison of pooled Versus Individual Sera in Avian Infectious Bronchitis Virus Seroprevalence Study)

  • 김사림;권혁무;성환우;박선일
    • 한국임상수의학회지
    • /
    • 제23권4권
    • /
    • pp.416-420
    • /
    • 2006
  • Compare to testing sera individually, pooled-serum testing has considered as a cost-effective method, particularly on a large population-based seroprevalence studies. This study was to determine the relationship between individual sera and pooled sera titers for detection of avian infectious bronchitis virus (IBV) and to evaluate suitability of pooled sera by comparing prevalences estimated from both samples. A total of 5,000 individual samples were collected from 500 flocks in Chungcheong, Gyunsgi, and Kangwon provinces between January 2005 and February 2006. Ten samples were randomly selected from each flock. Five-hundred pooled sera were prepared by mixing equal amount of each 10 individual serum from the original samples. IBV antibody titers were measured by hemagglutination inhibition (HI) test. The least squares regression analysis was performed to construct equation between pooled and mean individual titers. To determine whether the flock is infected 4 arbitrary criteria were used: detection of at least 1 chicken with HI titer ${\ge}$ 9 (criterion 1), detection of at least 2 samples with HI titer ${\ge}$9 (criterion 2), detection of at least 1 sample with HI titer ${\ge}$ 10 (criterion 3), and filially detection of at least 1 sample with HI titer ${\ge}$ 11 (criterion 4). The receiver operating characteristic (ROC) curve was used to examine the cut-off points of pooled titers showing optimal diagnostic accuracy. The area under the curve (AUC), sensitivities (Se), specificities (Sp), and positive (PPV) and negative (NPV) predictive values were calculated. The regression equation between pooled titers (pool) and mean individual titers (mean) was: $pool= 1.2498+0.8952{\times}mean$, with coefficient of determination of 87% (p< 0.0001). The optimal cut-off points of pooled titers were titer 8 for criterion 1 (AUC=0.975, Se=0.883, Sp=0.959, PPV=0.985, NPV=0.728), titer 8 for criterion 2 (AUC=0.969, Se=0.954, Sp=0.855, PPV=0.926, NPV=0.907), titer 9 for criterion 3 (AUC=0.970, Se=0.836, Sp=0.967, PPV=0.978, NPV=0.772), and titer 9 for criterion 4 (AUC= 0.946, Se=0.928, Sp=0.843, PPV=0.857, NPV=0.921). The difference of 'prevalence estimated by individual and pooled sample showed a minimum of 2% for criteria 2 and a maximum of 9.1:% for criteria 3. These results indicate that the use of pooled sera in HI test for screening IBV infection in laying hen flocks is considered as a cost-effective method of testing large numbers of samples with high diagnostic accuracy.

수질분야 총유기탄소 분석방법에 따른 장비별 특성 비교 (Comparison of Instrument Characteristics on the Total Organic Carbon Analysis Method in Water Samples)

  • 김혜성;황은태;이찬근;조영철
    • 환경영향평가
    • /
    • 제32권5호
    • /
    • pp.353-362
    • /
    • 2023
  • TOC는 수중에 있는 유기물질의 90% 이상을 측정할 수 있으며 신속하고 용이하게 측정할 수 있기 때문에 기존에 사용된 유기오염물질의 지표인 BOD와 COD를 대체하고 있다. 수질오염공정시험기준에 따라 TOC를 측정할 때, 시료의 총탄소 중 무기탄소 비율이 50% 이상일 경우 NPOC법으로 분석하고, 휘발성유기화합물이 수 mg/L 이상일 경우 가감(TC-IC)법으로 분석하도록 규정되어 있다. 이러한 분석조건의 제한성을 검증하기 위해 정제수에 총유기탄소와 무기성 탄소의 비율이 다르게 하여 시험용액에서 총유기 탄소 농도결과를 확인하였는데 가감법과 NPOC법에서 큰 차이가 나타나지 않았다. 휘발성유기화합물 표준 용액을 첨가한 시료를 측정한 결과, NPOC법으로 분석할 때에 퍼징으로 인해 유실되는 탄소량은 크지 않은 것으로 나타나 시료에 휘발성유기화합물이 존재 시 분석방법에 따른 차이는 크지 않은 것으로 판단된다. 수질오염공정시험기준과 환경측정기기의 형식승인·정도검사 등에 관한 고시의 기준에 의한 판정 결과가 달라지는 경우를 판단하기 위해 국내에서 널리 사용하고 있는 2종류의 총유기탄소분석기의 현장시료 농도값 차를 비교한 결과, 제조사에 따라 NPOC법과 가감법에서 0.02~0.83 mg/L 차이가 있었으며, 이에 따라 기기 선정시 주의가 필요할 것으로 판단되었다.

진공급탕식 다이캐스팅법을 이용한 자동차 콤프레서용 하우징 부품 개발 (Development of a Housing Component for an Auto-compressor Using Vacuum Ladling Die Casting)

  • 이항수;박정식
    • 소성∙가공
    • /
    • 제21권3호
    • /
    • pp.195-201
    • /
    • 2012
  • A vacuum ladling die casting system is suggested as a means to obtain a high vacuum level. A high vacuum of 17.8 mmHg is obtained by sealing the inner space of the mould. The sample product is a rear-head housing for an auto-compressor, and the die-casting with 6-cavities was conducted. The flow analysis shows that the filling speed during vacuum ladling is faster than for a non-vacuum system. The air holes in the sample product were too small to be seen with the naked eye in X-ray films. Density tests show that the high vacuum ladling system reduces the internal porosity as much as 57.8% when compared to the non-vacuum system. A defective rate of only 0.17% was found from leak testing. The results of this research prove that the high vacuum die-casting process is useful for manufacturing of aluminium components under high internal pressure.

Order-Restricted Inference with Linear Rank Statistics in Microarray Data

  • Kang, Moon-Su
    • 응용통계연구
    • /
    • 제24권1호
    • /
    • pp.137-143
    • /
    • 2011
  • The classification of subjects with unknown distribution in a small sample size often involves order-restricted constraints in multivariate parameter setups. Those problems make the optimality of a conventional likelihood ratio based statistical inferences not feasible. Fortunately, Roy (1953) introduced union-intersection principle(UIP) which provides an alternative avenue. Multivariate linear rank statistics along with that principle, yield a considerably appropriate robust testing procedure. Furthermore, conditionally distribution-free test based upon exact permutation theory is used to generate p-values, even in a small sample. Applications of this method are illustrated in a real microarray data example (Lobenhofer et al., 2002).

Utilization of Vitrified Glass as an Aggregate Source in Asphalt Concrete Mixtures

  • Min, Jeong-Ki
    • 한국농공학회지
    • /
    • 제39권2호
    • /
    • pp.51-56
    • /
    • 1997
  • Abstract Over 4.1 billion tons of non-hazardous solid wastes are generated in the United States annually. This equals to about 16 tons of wastes per person, per year. Disposal of the wastes is a national concern due to many factors such as environmental issues, costs, and public views. South Carolina, like many other states, had a home of many military bases which were ordered to be closed. The contaminated soil was vitrified and tested for suitability in the asphalt mixes. For mix design purposes, a total of 75 specimens were made and tested. For moisture susceptibility testing, a total of 32 samples were made and tested. The results indicate that the mixtures made with sample B produced dry and wet that were comparable with the controlled mixture. At this point and with in this limited study, use of 5% of sample B in asphalt mixture is recommended in several applications such as parking lots, walking paths and drive ways.