Browse > Article
http://dx.doi.org/10.3807/JOSK.2013.17.4.296

LDL Cholesterol Testing Device using Serial Reflected Face-to-Face Mirror System  

Choi, Min-Seong (School of Information and Communication Engineering, Sungkyunkwan University)
Yoo, Jae-Chern (School of Information and Communication Engineering, Sungkyunkwan University)
Publication Information
Journal of the Optical Society of Korea / v.17, no.4, 2013 , pp. 296-299 More about this Journal
Abstract
A low density lipoprotein (LDL) cholesterol testing device, structured with serial reflected face-to-face mirror (SRM) allowing spectrophotometry measurements, is presented. The spectrophotometry has been employed to measure the amount of light that a sample absorbs, but it generally should have had path length longer than 10 mm to secure enough sensitivity. Such requirement of path length has often been problematic in implementing a thin type of lab on a disc (LOD). We developed the SRM system which was implemented in a detection chamber with 1.4mm thickness, providing path length longer than 10mm, and thus straightforwardly being applicable to LOD as thin as a compact disc. The experimental results show that the SRM system gives not only a much thinner design compared to the conventional spectrophotometry-based LOD but also a comparable performance to already commercialized spectrometers.
Keywords
Lab-on-a-disc; Serial reflection; Optical sensing device; Optical path length;
Citations & Related Records
연도 인용수 순위
  • Reference
1 J. R. Crouse, J. S. Parks, H. M. Schey, and F. R. Kahl, "Studies of low density lipoprotein molecular weight in human beings with coronary artery disease," Journal of Lipid Research 26, 566-574 (1985).
2 Z. Matharu, G. Sumana, M. K. Pandey, V. Gupta, and B. D. Malhotra, "Low density lipoprotein sensor based on surface plasmon resonance," Thin Solid Films 518, 719-723 (2009).   DOI   ScienceOn
3 Z. Matharu, A. J. Bandodkar, G. Sumana, P. R. Solanki, E. M. I. M. Ekanayake, K. Kaneto, V. Gupta, and B. D. Malhotra, "Low density lipoprotein detection based on antibody immobilized self-assembled monolayer: Investigations of kinetic and thermodynamic properties," J. Phys. Chem. B 113, 14405-14412 (2009).   DOI   ScienceOn
4 M. Grumann, I. Moser, J. steigert, L. Riegger, A. Geipel, C. Kohn, G. Urban, R. Zengele, and J. ducree, "Optical beam guidance in monolithic polymer chips for miniaturized colorimetric assays," in Proc. Micro Electro Mechanical Systems, MEMS 2005 (Miami, FL, USA, 2005), pp. 108-111.
5 D. D. Nolte, "Invited review article: review of centrifugal microfluidic and bio-optical disks," Review of Scientific Instruments 80, 101101 (2009).   DOI   ScienceOn
6 K. Z. Liu, R. A. Shaw, A. Man, T. C. Dembinski, and H. H. Hantsch, "Reagent-free, simultaneous determination of serum cholesterol in HDL and LDL by infrared spectroscopy," Clinical Chemistry 48, 499-506 (2002).
7 B. S. Lee, Y. U. Lee, H. S. Kim, T. H. Kim, J. Park, J. G. Lee, J. T. Kim, H. S. Kim, W. G. Lee, and Y. K. Cho, "Fully integrated lab-on-a-disc for simultaneous analysis of biochemistry and immunoassay from whole blood," Lab Chip 11, 70-78 (2011).   DOI   ScienceOn
8 D. C. Duffy, H. L. Gillis, J. Lin, N. F. Sheppard, Jr., and G. J. Kellogg, "Microfabricated centrifugal microfluidic systems: characterization and multiple enzymatic assays," Anal. Chem. 71, 4669-4678 (1999).   DOI   ScienceOn
9 R. Corkin, M. Czugala, C. Rovira-Borras, J. Ducree, D. Diamond, and F. B. Lopez, "A wireless paired emitter detector diode device as an optical sensor for lab-on-a-disc applications," in Proc. Transducers'11 (Beijing, China, June 2011), pp. 2526-2529.
10 T. O. Tiffany, C. A. Burtls, J. C. Mailen, and L. H. Thacker, "Dynamic multicuvette fluorometer-spectrophotometer based on the GeMSAEC face analyzer principle," Anal. Chem. 45, 1716-1723 (1973).   DOI
11 M. Situmorang, P. W. Alexander, and D. B. Hibbert, "Flow injection potentiometry for enzymatic assay of cholesterol woth a tungsten electrode sensor," Talanta 49, 639-679 (1999).   DOI   ScienceOn
12 J. Steigert, M. Grumann, T. Brenner, L. Riegger, J. Harter, R. Zengerle, and J. Ducree, "Fully integrated whole blood testing by real-time absorption measurement on a centrifugal platform," Lab chip 6, 1040-1044 (2006).   DOI   ScienceOn
13 L. Charpentier and N. E. Murr, "Amperometric determination of cholesterol in serum with use of a renewable surface peroxidase electrode," Analytica Chimica Acta 318, 89-93 (1995).   DOI   ScienceOn
14 T. Nakaminami, S. Ito, S. Kuwabata, and H. Yoneyama, "Amperometric determination of total cholesterol at gold electrodes covalently modified with cholesterol oxidase and cholesterol esterase with use of thionin as an electron mediator," Anal. Chem. 71, 1068-1076 (1999).   DOI   ScienceOn
15 T. Nakaminami, S. Kuwabata, and H. Yoneyama, "Electrochemical oxidation of cholesterol catalyzed by cholesterol oxidase with use of an artificial electron mediator," Anal. Chem. 69, 2367-2372 (1997).   DOI   ScienceOn
16 M. A. T. Gilmartin and J. P. Hart, "Fabrication and characterization of a screen-printed, disposable, amperometric cholesterol biosensor," Analyst 119, 2331-2336 (1994).   DOI   ScienceOn
17 E. Koller, O. Quehenberger, G. Jurgens, O. S. Wolfbeis, and H. Esterbauser, "Investigation of human plasma low density lipoprotein by three-dimensional fluorescence spectroscopy," FEBS letters 198, 229-234 (1986).   DOI   ScienceOn