• Title/Summary/Keyword: Safety Equipment

Search Result 2,946, Processing Time 0.033 seconds

A Study on Protective Purposes and Intents of Use of Safety Helmets as for Reduction of Falls (추락사고 감소를 위한 안전모의 보호목적과 사용의도에 대한 고찰)

  • Kim, Jin Hyun
    • Journal of the Korean Society of Safety
    • /
    • v.28 no.5
    • /
    • pp.83-89
    • /
    • 2013
  • Occupational Safety and Health Act provides that industrial safety helmets are personal protective equipment(PPE) to protect heads against falls from a height. Relevant domestic regulations are distinguished and different from other countries' cases. This study investigated industrial safety helmet's protective purposes and characteristics related to falls and the notion of fall prevention. A comparative analysis of regulations on safety helmets and fall prevention as well as standards on safety helmet's impact test requirements is followed by a literature review. It is also suggested that the term "fall" related to safety helmets should be changed to "impact on the upper part of head" in domestic regulations and standards.

Revaluation of Inelastic Structural Response Factor for Seismic Fragility Evaluation of Equipment (기기의 지진취약도 평가를 위한 구조물 비탄성구조응답계수의 재평가)

  • Park, Junhee;Choi, In-Kil
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.28 no.3
    • /
    • pp.241-248
    • /
    • 2015
  • There are a lot of equipment related to safety and electric power production in nuclear power plants. The structure and equipment in NPPs were generally designed considering a high safety factor to remain in the elastic zone under earthquake load. However it is needed to revaluate the seismic capacity of the structure and equipment as the magnitude of earthquake was recently increased. In this study the floor response due to the nonlinear behaviors of structure was analyzed and the inelastic structural response factor was calculated by the nonlinear time history analysis. The inelastic structural response factor was calculated by the EPRI method and the nonlinear analysis method to realistically evaluate the seismic fragility for the equipment. According to the analysis result, it was represented that the inelastic structural response factor was affected by the natural frequency of equipment, the location of equipment and the dynamic property of structure.

Development of Real-time Process Management System for improving safety of Shop Floor (생산현장의 안전성 향상을 위한 실시간 공정관리 시스템 개발)

  • Lee, Seung Woo;Nam, So Jeong;Lee, Jai Kyung;Lee, Hwa Ki
    • Journal of the Korea Safety Management & Science
    • /
    • v.15 no.4
    • /
    • pp.171-178
    • /
    • 2013
  • Workers are avoiding production/manufacturing sites due to the poor working environment and concern over safety. Small and medium-sized businesses introduce new equipment to secure safety in the production site or ensure effective process management by introducing the real-time monitoring technique for existing equipment. The importance of real-time monitoring of equipment and process in the production site can also be found in the ANSI/ISA-195 model. Note, however, that most production sites still use paper-based work slip as a process management technique. Data reliability may deteriorate because information on the present condition of the production site cannot be collected/analyzed properly due to manual data writing by the worker. This paper introduces the monitoring and process management technique based on a direct facility interface to secure safety in the field by improving the poor working environment and enhance there liability and real-time characteristics of the production data. Since the data is collected from equipment in real-time directly through the SIB-based interface and PLC-based interface, problems associated with workers' manual data input are expected to be solved; safety can also be improved by enhancing workers' attention to work by minimizing workers' injuries and disruption.

Development of Railway Platform Safety Equipment using Laser Radar Sensor (레이저 레이더 센서를 이용한 철도 승강장 안전설비의 개발)

  • Kim, Yoo-Ho;Hwang, Jong-Gyu;Jo, Hyun-Jeong;Baek, Jong-Hyun;Kim, Baek-Hyun;Ko, Tae-Kuk
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.62 no.2
    • /
    • pp.57-64
    • /
    • 2013
  • Many accidents are being occurred due to many missteps, etc. at the railway platform. Recently in Korea, efforts to prevent casualties fundamentally are being made by installing and operating the PSD(Platform Screen Door) with underground station building as its center to prevent these casualties of passengers. Although this PSD can solve the problem of public casualties at platform fundamentally, it is impossible to install it at whole station buildings since its installation cost is high, and in case of the ground station building of general railway whose operation speed is higher, installation of PSD is impossible due to the characteristics of railway system. This paper proposes the novel safety equipment using Laser radar sensors for the prevention against casualties of passengers at station buildings where the PSDs are not installed like this. The safety equipment using Laser radar sensors is the safety equipment making an approaching train stopped if the falling object is a person by detecting the obstacle at platform through, and it has the merit possible to apply it to station buildings not only in the underground section but also in the ground section since it may detect accurately under ambient environmental elements such as the snow, rain and yellow dust, etc. also. We developed the prototype of the safety equipment to reduce public casualties at platform by using Laser radar sensors and carried out its performance test, and the result is presented in this paper.

A Study of Explosion Hazard Proof Modeling for Risk Minimization to Semiconductor & FPD Manufature Equipment and Clean Room (반도체·FPD 제조설비와 클린룸의 RISK 최소화를 위한 폭발위험장소 설정 모델링에 관한 연구)

  • Noh, HyunSeok;Woo, InSung;Hwang, MyungHwan;Woo, JungHwan
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.1
    • /
    • pp.78-85
    • /
    • 2018
  • In this study, we analyzed risks of the fabrication process equipment and cleanroom for semiconductor/flat panel display (FPD) manufacturing facilities and studied the fundamental safety measures for the risk factors. We examined the explosion proof design models considering the specificity of equipment and environment, and planned to utilize the findings to provide technical standards and grounds for designing and manufacturing related equipment. We believe that this study will contribute to the establishment of technical standards for semiconductor/FPD industry and businesses in many different ways by providing optimized modeling of high-risk explosion site detection, developing safety standards and hazard countermeasures and voluntary activation of safety certification system for operation of fabrication process equipment.

Development of Composite Examination Equipment for Improvement of Fire Detectors Checking Technology (감지기의 점검 기술향상을 위한 복합시험기의 개발)

  • Kong, Ha-Sung;Lee, Jong-Hwa
    • Journal of the Korea Safety Management & Science
    • /
    • v.10 no.4
    • /
    • pp.135-143
    • /
    • 2008
  • Recently as the testing of fire detector used the testing device for fire detector, there are something the matter in the perception function loss of fire detector, structure and form of the testing device for fire detector. The problem at oxidation of emitting smoke ashes hazardous article part and so on that checking person absorbs be. In this paper the problem or the conventional the examination equipment of fire detectors is analysed and researched. To solve these problems after the theoretical study and design and paint drawing of equipment the prototype of composite examination equipment of fire detectors was made. After compared with the conventional, part that improve of composite examination equipment of fire detectors are verified through the examination. In the future it will be useful the operation state and correct operation time of the fire detectors are measured after the research about the quality of the material and transparency of bellows cover is done.

The analysis for flooding prevention countermeasures of Electrical facility and Transformer Vault on Foreign (국외 수변전실 및 지상 전력기기 침수방지 대책에 관한 조사연구)

  • Kim, Gi-Hyun;Lee, Sang-Ick;Jean, Hyun-Jae;Bae, Suk-Myong;Lee, Jae-Young
    • Proceedings of the KIEE Conference
    • /
    • 2008.09a
    • /
    • pp.305-307
    • /
    • 2008
  • Inundation of substation and ground power equipment breaks out every summer season in low-lying downtown and low-tying shore by heavy rain, typhoon and tidal wave. In case inundation excluding the exchanging cost of equipment, it occurs a great economic and social loss owing to recovery time and events of electric shock occur by inundation electrical equipment (Pad-mounted Transformer and Switch). So we research the flooding prevention countermeasures of electrical facility and Transformer Vault on Foreign. We conform the site facility and related regulation for flooding prevention on Foreign.

  • PDF

Facility Layout Planning for the Safety 7th Curriculum of Technology Laboratory in a Middle School (제7차 교육과정을 고려한 중학교(中學校) 기술실(技術室)의 안전.시설.설비(安全.施設.設備) 배치(配置) 계획(計劃))

  • Kim, Jong-Bok;Lee, Sang-Hyuk
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.10 no.3
    • /
    • pp.15-26
    • /
    • 2003
  • The purpose of this study is to describe the planning and applied safety facility layout for a technology laboratory in a middle school. A technological teaching facility has its essential purpose in meeting students' needs and achieving educational objectives efficiently and effectively. Practice-related appliances were selected through investigation of the current middle school laboratory, and analysis of the technology textbooks of the 7th curriculum. Laboratory layout was achieved with consideration of the teacher's and students need of safety and close proximity to laboratory facilities and equipment. Our recommendation takes the SLP survey results into consideration. The results of this study are as follows: The following floor plan is recommended. The facility layout will insure that students are able to work safely, in full view of academic instructors. Students will have easy access to all equipment due to the efficient floor plan and logical sequencing of equipment.