• Title/Summary/Keyword: Safety Device

Search Result 1,796, Processing Time 0.035 seconds

Analysis of the Difference on Elementary Students' School Adaptation and Academic Performance by Dependence on Smart Devices

  • Lee, KyungHee;Park, Hye-Young
    • Journal of the Korea Society of Computer and Information
    • /
    • v.27 no.4
    • /
    • pp.213-221
    • /
    • 2022
  • The purpose of this study is to find methods to prevent and improve smart device over-dependence problems by analyzing differences in school life adaptation and academic performance according to children's dependence on smart devices. For this, the data of fifth grade elementary school students in the 12th year were extracted and utilized from Panel Survey of Korean Children. The data were analyzed using non-hierarchical cluster(K-means) analysis, T-test, one-way ANOVA, and Scheffé tests. The results of this study are as follows. First, It has been shown that dependence on smart devices, school adaptation and academic performance have a negative correlation. Second, students in potential and high-risk groups who are highly dependent on smart devices have significantly lower school adaptation compared to those in the safety group. Third, high-risk students showed significantly lower academic performance compared to those in the potential risk group and general group. Based on these findings, it was suggested that for elementary school students who rely on smart devices, various learning support and national efforts such as counseling for school life adaptation are needed.

Design and Function Analysis of Dust Measurement Platform based on IoT protocol (사물인터넷 프로토콜 기반의 미세먼지 측정 플랫폼 설계와 기능해석)

  • Cho, Youngchan;Kim, Jeongho
    • Journal of Platform Technology
    • /
    • v.9 no.4
    • /
    • pp.79-89
    • /
    • 2021
  • In this paper, the fine dust (PM10) and ultrafine dust (PM2.5) measurement platforms are designed to be mobile and fixed using oneM2M, the international standard for IoT. The fine dust measurement platform is composed and designed with a fine dust measurement device, agent, oneM2M platform, oneM2M IPE, and monitoring system. The main difference between mobile and fixed is that the mobile uses the MQTT protocol for interconnection between devices and services without blind spots based on LTE connection, and the fixed uses the LoRaWAN protocol with low power and wide communication range. Not only fine dust, but also temperature, humidity, atmospheric pressure, volatile organic compounds (VOC), carbon monoxide (CO), sulfur dioxide (SO2), nitrogen dioxide (NO2), and noise data related to daily life were collected. The collected sensor values were managed using the common API provided by oneM2M through the agent and oneM2M IPE, and it was designed into four resource types: AE and container. Six functions of operability, flexibility, convenience, safety, reusability, and scalability were analyzed through the fine dust measurement platform design.

Transient simulation and experiment validation on the opening and closing process of a ball valve

  • Han, Yong;Zhou, Ling;Bai, Ling;Xue, Peng;Lv, Wanning;Shi, Weidong;Huang, Gaoyang
    • Nuclear Engineering and Technology
    • /
    • v.54 no.5
    • /
    • pp.1674-1685
    • /
    • 2022
  • The ball valve is an important device in the pipeline transportation system of nuclear power plants. Its operational stability and safety directly affect the normal working of nuclear power plants. In this study, the transient numerical simulation of the opening and closing process of a ball valve was conducted on the basis of the flow interruption capability experiment of the ball valve by using the moving mesh method and inlet and outlet variable boundary conditions. The flow rate and pressure difference with time of the opening and closing process of the ball valve were studied. The internal flow characteristics of the ball valve under different relative openings were analyzed in conjunction with the typical back-step flow structure. Results show that the transient numerical results agree well with the experimental results. The internal flow characteristics of the ball valve are similar at the same opening during opening and closing process. At small opening, the spool and outlet channels easily form a back-step flow structure. The disappearance and generation of backflow vortices during opening and closing occur at 85% opening and 75% opening, respectively. With the decrease in opening degree, the difference in vortex core area in the flow channel of the ball valve spool in the opening and closing process gradually appears. The research results provide some reference value for the design and optimization of ball valves.

Design and implementation of blockchain-based anti-theft protocol in Lora environment (Lora 환경에서 블록체인 기반 도난방지 프로토콜 설계 및 구현)

  • Park, Jung-oh
    • Journal of Convergence for Information Technology
    • /
    • v.12 no.4
    • /
    • pp.1-8
    • /
    • 2022
  • With the development of communication infrastructure, the number of network equipment owned by one person is gradually increasing. General-purpose devices such as smartphones can implement theft/loss prevention function by implementing S/W. However, other small devices lack practicality such as long-distance communication problems due to standard communication technology specifications or H/W limitations, and lack of functions(authentication and security). This study combines the Lora communication protocol in the LPWA standard environment and the blockchain technology. Anti-theft and security functions were added to the protocol, and the PBFT consensus algorithm was applied to build a blockchain network. As a result of the test, the effectiveness of safety(authentication and trust network) and performance(blockchain processing performance) were confirmed. This study aims to contribute to the future development of portable or small device anti-theft products as a 4th industrial convergence research.

A Research on the Promotion of AMI Supply by the Development of 1:N Mounted Remote Meter Reading Device (1:N HUB 기능을 가진 원격검침 단말기 개발에 따른 AMI 보급 추진 방안 연구)

  • Lee, Hyoung-Min;Kim, Min-Gi;Choi, Eun-Il;Yoon, Chan-Sik
    • Journal of the Korean Institute of Gas
    • /
    • v.25 no.6
    • /
    • pp.1-6
    • /
    • 2021
  • In this study, we developed AMI terminals of 1 (reader): N (small transmitter). Currently, the government is focusing on the Gas AMI demonstration project to advance the outdated metering system of the urban gas industry, led by the government-sponsored ministries. The supply of gas AMI meters has the advantage of resolving uncertainties in privacy violations and measurement information and preparing for consumer safety through gas leakage detection. In the case of existing AMI meters, readers and transmitters were 1:1 methods, while this technology can be extended to multiple generations with a 1:N method, and a technology that can extend battery life by implementing a low-power design is applied. We hope that this research will contribute to the gas AMI supply project in the future.

Laser-assisted Delivery of a Combined Antioxidant Formulation Enhances the Clinical Efficacy of Fractional Microneedle Radiofrequency Treatment: A Pilot Study

  • Kim, Jihee;Kim, Soo Min;Jung, Bok Ki;Oh, Sang Ho;Kim, Young-Koo;Lee, Ju Hee
    • Medical Lasers
    • /
    • v.10 no.3
    • /
    • pp.161-169
    • /
    • 2021
  • Background and Objectives Fractional microneedle radiofrequency systems are popular options to increase elasticity in aging skin. Laser-assisted drug delivery is a promising method for the epidermal injection of topically applied drugs and cosmetic ingredients. This study assesses the safety and efficacy of topical delivery of L-ascorbic acid, vitamin E, and ferulic acid after fractional microneedle radiofrequency treatment for reducing photodamage. Materials and Methods In this prospective, single-center, split-face, controlled pilot study, six women (mean age, 48.0 years; range, 35-57 years; Fitzpatrick skin types III and IV) exhibiting mild to moderate photodamage, underwent a single session of fractional microneedle radiofrequency treatment. The patients were instructed to apply the antioxidant formulation to only one side of the face. Patients were evaluated 3 days, 7 days, and 4 weeks thereafter, using three-dimensional imaging and ultrasound. Ex vivo, the full-thickness human skin was used for molecular and histological evaluation. Statistical analysis was achieved by applying t-tests, Mann-Whitney U tests, and one-way analyses of variance. Results Compared to the untreated side, the antioxidant-treated side exhibited a significant increase in dermal thickness (10.32% vs. 17.54%, p < 0.05), but not in skin elasticity (4.76% vs. 4.69%, p > 0.05). The difference in erythema between the sides was statistically not significant (p > 0.05). In the ex vivo model, expression of FGF2 in the skin was significantly increased after application of the antioxidant formulation, as compared to results obtained subsequent to fractional microneedle radiofrequency treatment only (p < 0.01). Conclusion This study demonstrates that for the treatment of photodamaged skin, laser-assisted delivery of the antioxidant formulation is a safe and effective adjuvant modality following fractional microneedle radiofrequency.

Failure probability of tall buildings with TMD in the presence of structural, seismic, and soil uncertainties

  • Sadegh, Etedali;Mohammad, Seifi;Morteza, Akbari
    • Structural Engineering and Mechanics
    • /
    • v.85 no.3
    • /
    • pp.381-391
    • /
    • 2023
  • The seismic performance of the tall building equipped with a tuned mass damper (TMD) considering soil-structure interaction (SSI) effects is well studied in the literature. However, these studies are performed on the nominal model of the seismic-excited structural system with SSI. Hence, the outcomes of the studies may not valid for the actual structural system. To address the study gap, the reliability theory as a useful and powerful method is utilized in the paper. The present study aims to carry out reliability analyses on tall buildings equipped with TMD under near-field pulse-like (NFPL) ground motions considering SSI effects using a subset simulation (SS) method. In the presence of uncertainties of the structural model, TMD device, foundation, soil, and near-field pulse-like ground motions, the numerical studies are performed on a benchmark 40-story building and the failure probabilities of the structures with and without TMD are evaluated. Three types of soils (dense, medium, and soft soils), different earthquake magnitudes (Mw = 7,0. 7,25. 7,5 ), different nearest fault distances (r = 5. 10 and 15 km), and three seismic performance levels of immediate occupancy (IO), life safety (LS), and collapse prevention (CP) are considered in this study. The results show that tall buildings built near faults and on soft soils are more affected by uncertainties of the structural and ground motion models. Hence, ignoring these uncertainties may result in an inaccurate estimation of the maximum seismic responses. Also, it is found the TMD is not able to reduce the failure probabilities of the structure in the IO seismic performance level, especially for high earthquake magnitudes and structures built near the fault. However, TMD is significantly effective in the reduction of failure probability for the LS and CP performance levels. For weak earthquakes and long fault distances, the failure probabilities of both structures with and without TMD are near zero, and the efficiency of the TMD in the reduction of failure probabilities is reduced by increasing earthquake magnitudes and the reduction of fault distance. As soil softness increases, the failure probability of structures both with and without TMD often increases, especially for severe near-fault earthquake motion.

Vehicle control system base on the low power long distance communication technology(NB-IoT)

  • Kim, Sam-Taek
    • Journal of the Korea Society of Computer and Information
    • /
    • v.27 no.6
    • /
    • pp.117-122
    • /
    • 2022
  • In this paper, we developed a vehicle control terminal using IoT and low-power long-distance communication (NB-IoT) technology. This system collects information on the location and status of a parked vehicle, and transmits the vehicle status to the vehicle owner's terminal in real time with low power to prevent vehicle theft, and in the case of a vehicle in motion, When primary information about the vehicle, such as an impact, is collected and transmitted to the server, the server analyzes the relevant data to generate secondary information on traffic congestion, road damage, and safety accidents. By sending it, you can know the exact arrival time of the vehicle at its destination. This terminal device is an IoT gateway for a vehicle and can be connected to various wired and wireless sensors inside the vehicle. In addition, the data collected from vehicle maintenance, efficient operation, and vehicles can be usefully used in the private or public sector.

Development of Thermostat for the Fluxgate Magnetometer in Icheon Geomagnetic Observatory and Stability Evaluation after Installation (이천 지자기 관측소 플럭스게이트 자력계 온도 조절 장치 개발 및 설치 후 안정성 자체 평가 )

  • Dooyoung, Choi;Seunguk, Lee;Joonsung, Kim;Dae-Young, Lee;Kyu-Cheol, Choi;Junghee, Cho
    • Journal of Space Technology and Applications
    • /
    • v.2 no.3
    • /
    • pp.221-229
    • /
    • 2022
  • This paper reports on the design and installation of a thermostat to keep the temperature of the fluxgate magnetometer constant and the data stability evaluation after installation. The thermostat was installed at the Icheon Geomagnetic Observatory operated by the Korean Space Weather Center of National Radio Research Agency. It was designed in consideration of stability of temperature control against safety incident, potential effects on magnetic field measurement, and the temperature control efficiency. After the temperature control device was installed, it was confirmed that the temperature was constantly maintained at the level of 20℃. Delta F and baseline values were used to evaluate geomagnetic data stability, and it was confirmed that delta F and baseline fluctuations were reduced after installation of the thermostat.

The presence of carcinogenic radon in the Padma River water, adjacent to the Rooppur Nuclear Power Plant

  • M.M. Mahfuz Siraz;M.S. Alam;Jubair A.M.;S.C. Das;J. Ferdous;Z. Hossain;S. Das;Mayeen Uddin Khandaker;D.A. Bradley;Shinji Tokonami;S. Yeasmin
    • Nuclear Engineering and Technology
    • /
    • v.55 no.8
    • /
    • pp.3046-3053
    • /
    • 2023
  • Radon is a naturally occurring carcinogenic agent, poses a serious health hazard when inhaled or ingested in significant amounts. The water of the Padma river will be used as a tertiary coolant for the soon-to-be-commissioned 'Rooppur Nuclear Power Plant'. Hence, it is important to assess the radiological status of the river prior to the commission of this power plant. Therefore, for the first time, 25 samples of water were collected from various locations of the Padma River and analyzed for radon concentration using the RAD H2O (DURRIDGE) radon monitoring device. The radon concentrations were found in the range from 0.077 ± 0.036 to 0.494 ± 0.211 Bq/L with a mean of 0.250 ± 0.093 Bq/L. All the concentrations were found to be below the recommended limits of WHO (100 Bq/L) and USEPA (11.1 Bq/L). The mean annual effective dose due to the radon exposure via inhalation and ingestion pathways were 0.638 µSv/y and 0.629 µSv/y, respectively, which were all well below the annual effective dose recommended by WHO (0.1 mSv/y). Since Bangladesh lacks a national safety limit of radon in water, this pioneering study provides baseline data on radon levels for the environment around Rooppur Nuclear Power Plant.