• Title/Summary/Keyword: SOGI-PLL

Search Result 11, Processing Time 0.021 seconds

Analysis and experiment of SOGI-PLL technique (SOGI-PLL기법 분석 및 실험)

  • Mun, Byeongho;Jo, Hyunsik;Cha, Hanju
    • Proceedings of the KIPE Conference
    • /
    • 2012.07a
    • /
    • pp.162-163
    • /
    • 2012
  • 계통연계 인버터에서 계통전압과 위상을 일치시키기 위한 PLL은 필수이다. 기존의 PLL의 경우 계통전압에 불평형이 발생하면 계통의 위상을 정확하게 추종할 수 없기 때문에 제어를 할 수 없게 되고 이는 시스템에 심각한 영향을 미칠 수 있다. 따라서 불평형 전압이 발생하여도 정확하게 위상을 추종할 수 있는 기법의 필요하다. 본 논문에서는 SOGI(Second - Order Generalized Intergrator)를 소개하고 시뮬레이션과 실험을 통해 그 타당성을 검증한다.

  • PDF

Design of a High-performance High-pass Generalized Integrator Based Single-phase PLL

  • Kulkarni, Abhijit;John, Vinod
    • Journal of Power Electronics
    • /
    • v.17 no.5
    • /
    • pp.1231-1243
    • /
    • 2017
  • Grid-interactive power converters are normally synchronized with the grid using phase-locked loops (PLLs). The performance of the PLLs is affected by the non-ideal conditions in the sensed grid voltage such as harmonics, frequency deviations and the dc offsets in single-phase systems. In this paper, a single-phase PLL is presented to mitigate the effects of these non-idealities. This PLL is based on the popular second order generalized integrator (SOGI) structure. The SOGI structure is modified to eliminate the effects of input dc offsets. The resulting SOGI structure has a high-pass filtering property. Hence, this PLL is termed as a high-pass generalized integrator based PLL (HGI-PLL). It has fixed parameters which reduces the implementation complexity and aids in the implementation in low-end digital controllers. The HGI-PLL is shown to have the lowest resource utilization among the SOGI based PLLs with dc cancelling capability. Systematic design methods are evolved leading to a design that limits the unit vector THD to within 1% for given non-ideal input conditions in terms of frequency deviation and harmonic distortion. The proposed designs achieve the fastest transient response. The performance of this PLL has been verified experimentally. The results agree with the theoretical prediction.

A Frequency-Tracking Method Based on a SOGI-PLL for Wireless Power Transfer Systems to Assure Operation in the Resonant State

  • Tan, Ping-an;He, Haibing;Gao, Xieping
    • Journal of Power Electronics
    • /
    • v.16 no.3
    • /
    • pp.1056-1066
    • /
    • 2016
  • Wireless power transfer (WPT) technology is now recognized as an efficient means of transferring power without physical contact. However, frequency detuning will greatly reduce the transmission power and efficiency of a WPT system. To overcome the difficulties associated with the traditional frequency-tracking methods, this paper proposes a Direct Phase Control (DPC) approach, based on the Second-Order Generalized Integrator Phase-Locked Loop (SOGI-PLL), to provide accurate frequency-tracking for WPT systems. The DPC determines the phase difference between the output voltage and current of the inverter in WPT systems, and the SOGI-PLL provides the phase of the resonant current for dynamically adjusting the output voltage frequency of the inverter. Further, the stability of this control method is analyzed using the linear system theory. The performance of the proposed frequency-tracking method is investigated under various operating conditions. Simulation and experimental results convincingly demonstrate that the proposed technique will track the quasi-resonant frequency automatically, and that the ZVS operation can be achieved.

SOGI-PLL-Based Frequency-Adaptive Current Controller for an LCL-Filtered Grid-Connected Inverter under Distorted Grid Environment (SOGI-PLL 기반 계통연계 LCL 인버터의 주파수 적응형 전류 제어기)

  • Kim, Yu-Bin
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2020.11a
    • /
    • pp.542-544
    • /
    • 2020
  • 최근 분산전원 시스템의 증가로 인해 계통연계 인버터의 사용이 꾸준하게 증가해 왔다. 계통연계 인버터의 제어를 위해 많이 사용되는 PI 제어기는 구조가 간단하여 제어기 구성이 쉽다는 장점이 있지만 계통 전압에 예상치 못한 전압 외란이 발생할 경우 전류 품질이 떨어지는 단점을 가지고 있다. 이를 극복하기 위해 본 논문에서는 LCL 필터를 사용하는 계통연계 인버터의 상태공간 모델을 이용하여 공진제어기와 적분제어기가 결합된 전 상태궤환 제어기법을 제시한다. 또한 계통외란과 주파수 변동으로 인해 발생하는 주파수 검출성능 향상을 위해 SOGI-PLL을 사용하여 시스템의 안정성을 보장한다. 제안된 기법의 타당성과 성능이 PSIM 시뮬레이션을 통하여 입증된다.

Performance Evaluation of Various PLL Techniques for Single Phase Grids (단상 계통연계 운전을 위한 다양한 PLL 기법의 성능 평가)

  • Das, Partha Sarati;Kim, Kyeong-Hwa
    • Proceedings of the KIPE Conference
    • /
    • 2013.07a
    • /
    • pp.47-48
    • /
    • 2013
  • In order to evaluate the response of the grid-connected systems, Phase lock technology is widely used in power electronic devices to obtain the phase angle, amplitude, and frequency of the grid voltage because phase locked loop (PLL) algorithms are very important for grid synchronization and monitoring in the grid connected power electronic devices. This paper presents a performance evaluation in tracking grid angular frequency through single phase synchronization techniques which are an enhanced PLL (EPLL), second-order generalized integrator-PLL (SOGI-PLL), and second-order generalized integrator-frequency locked loop (SOGI-FLL). These techniques are properly analyzed through several steps to get the best technique which can track the frequency accurately and smoothly.

  • PDF

A Robust PLL Technique Based on the Digital Lock-in Amplifier under the Non-Sinusoidal Grid Conditions (디지털 록인앰프를 이용한 비정현 계통하에서 강인한 PLL 방법)

  • Ashraf, Muhammad Noman;Khan, Reyyan Ahmad;Choi, Woojin
    • Proceedings of the KIPE Conference
    • /
    • 2018.11a
    • /
    • pp.104-106
    • /
    • 2018
  • The harmonics and the DC offset in the grid can cause serious synchronization problems for grid connected inverters (GCIs) which leads not able to satisfy the IEEE 519 and p1547 standards in terms of phase and frequency variations. In order to guarantee the smooth and reliable synchronization of GCIs with the grid, Phase Locked Loop (PLL) is the crucial element. Typically, the performance of the PLL is assessed to limit the grid disturbances e.g. grid harmonics, DC Offset and voltage sag etc. To ensure the quality of GCI, the PLL should be precise in estimating the grid amplitude, frequency and phase. Therefore, in this paper a novel Robust PLL technique called Digital Lock-in Amplifier (DLA) PLL is proposed. The proposed PLL estimate the frequency variations and phase errors accurately even in the highly distorted grid voltage conditions like grid voltage harmonics, DC offsets and grid voltage sag. To verify the performance of proposed method, it is compared with other six conventional used PLLs (CCF PLL, SOGI PLL, SOGI LPF PLL, APF PLL, dqDSC PLL, MAF PLL). The comparison is done by simulations on MATLAB Simulink. Finally, the experimental results are verified with Single Phase GCI Prototype.

  • PDF

PLL Control Strategy for ZVRT(Zero Voltage Ride Through) of a Grid-connected Single-phase Inverter (계통연계형 단상 인버터의 ZVRT(Zero Voltage Ride Through)를 위한 PLL 제어 전략)

  • Lee, Taeil;Lee, KyungSoo
    • Proceedings of the KIPE Conference
    • /
    • 2018.07a
    • /
    • pp.150-152
    • /
    • 2018
  • 계통 사고 시 계통연계형 인버터에 대한 각국의 계통 규정(Grid Code)이 더욱 엄격해 지고 있다. 계통 규정은 특히, 계통 내 저전압 사고로 인한 인버터 운전계속성(Low Voltage Ride Through, LVRT)뿐만 아니라 0 전압 사고 시 운전계속성(Zero Voltage Ride Through, ZVRT)을 통해 인버터가 계통 안정화에 기여할 것을 요구하고 있다. 계통연계형 인버터는 계통전압과 인버터 출력 위상을 일치시키는 PLL제어가 적용되며 본 논문에서는 위상 추종이 어려운 0 전압 상황에서도 안정적인 위상 추종 및 인버터 출력이 가능한 PLL 방법을 제안한다. 단상 인버터에 Notch filter-PLL, APF를 이용한 dq-PLL, 및 SOGI-PLL(Second-order Generalized Intergrator)을 적용하고 독일, 미국, 및 일본의 0 전압 상황에 대해 시뮬레이션과 실험을 진행하여 제안한 PLL 기법의 ZVRT 유효성을 확인하였다.

  • PDF

Single-Phase Inverter for Grid-Connected and Intentional Islanding Operations in Electric Utility Systems

  • Lidozzi, Alessandro;Lo Calzo, Giovanni;Solero, Luca;Crescimbini, Fabio
    • Journal of Power Electronics
    • /
    • v.16 no.2
    • /
    • pp.704-716
    • /
    • 2016
  • Small distributed generation units are usually connected to the main electric grid through single-phase voltage source inverters. Grid operating conditions such as voltage and frequency are not constant and can fluctuate within the range values established by international standards. Furthermore, the requirements in terms of power factor correction, total harmonic distortion, and reliability are getting tighter day by day. As a result, the implementation of reliable and efficient control algorithms, which are able to adjust their control parameters in response to changeable grid operating conditions, is essential. This paper investigates the configuration topology and control algorithm of a single-phase inverter with the purpose of achieving high performance in terms of efficiency as well as total harmonic distortion of the output current. Accordingly, a Second Order Generalized Integrator with a suitable Phase Locked Loop (SOGI-PLL) is the basis of the proposed current and voltage regulation. Some practical issues related to the control algorithm are addressed, and a solution for the control architecture is proposed, based on resonant controllers that are continuously tuned on the basis of the actual grid frequency. Further, intentional islanding operation is investigated and a possible procedure for switching from grid-tied to islanding operation and vice-versa is proposed.

New PLL Control for Gird Cynchronization f Distributed Power System under Faulty Grid Conditions (계통 사고시 분산전원의 계통 동기화를 위한 새로운 PLL 제어)

  • Jang, Mi-Geum;Song, Sung-Geun;Oh, Seung-Yeol;Choi, Jung-Sik;Chung, Dong-Hwa
    • Proceedings of the KIPE Conference
    • /
    • 2011.11a
    • /
    • pp.271-272
    • /
    • 2011
  • 본 논문은 SOGI를 이용한 정상분 전압 검출을 기반으로 하는 SRF(synchronous reference frame)-PLL(phase locked loop) 시스템을 제안한다. 일반화된 2차 적분기의 이중으로 사용하여 QSG(Quadrature-signals generator)의 성능을 개선하여 전압 불평형, 고조파 왜곡 등으로 인한 오차 발생 시에도 빠르고 정확한 위상 검출이 가능하도록 하였으며 본 논문에서 제시한 알고리즘은 PSIM 프로그램 결과를 통하여 타당성을 입증한다.

  • PDF

High-Performance Control of Three-Phase Four-Wire DVR Systems using Feedback Linearization

  • Jeong, Seon-Yeong;Nguyen, Thanh Hai;Le, Quoc Anh;Lee, Dong-Choon
    • Journal of Power Electronics
    • /
    • v.16 no.1
    • /
    • pp.351-361
    • /
    • 2016
  • Power quality is a critical issue in distribution systems, where a dynamic voltage restorer (DVR) is commonly used to mitigate the voltage disturbances for loads. This paper deals with a nonlinear control for the three-phase four-wire (3P-4W) DVR under a grid voltage unbalance and nonlinear loads in the distribution system, where a novel control scheme based on the feedback linearization technique is proposed. Through feedback linearization, a nonlinear model of a DVR with a PWM voltage-source inverter (VSI) and LC filters is linearized. Then, the controller design of the linearized model is performed by applying the linear control theory, where the load voltages are kept constant by controlling the d-q-0 axis components of the DVR output voltages. To keep the load voltage unchanged, an in-phase compensation strategy is employed, where the load voltages are recovered to be the same as the previous voltage without a change in the magnitude. With this strategy, the performance of the DVR becomes faster and more stable even under unbalanced source voltages and nonlinear loads. The validity of the proposed control strategy has been verified by simulation and experimental results.