• Title/Summary/Keyword: SI combustion

Search Result 399, Processing Time 0.027 seconds

Surface Characteristics and Spontaneous Combustibility of Coal Treated with Non-polar Solvent under Room Temperature (상온에서의 용매 처리를 통한 저등급 석탄의 표면물성 및 자연발화 특성 변화)

  • Jo, Wan Taek;Choi, Ho Kyung;Kim, Sang Do;Yoo, Ji Ho;Chun, Dong Hyuk;Rhim, Young Joon;Lim, Jeong Hwan;Lee, Si Hyun
    • Korean Chemical Engineering Research
    • /
    • v.51 no.5
    • /
    • pp.609-614
    • /
    • 2013
  • This study investigated the spontaneous combustion behavior of solvent-treated low rank coals. Indonesian lignite (a KBB and SM coal) and sub-bituminous (a Roto coal) were mixed with non-polar 1-methyl naphthalene (1MN) either by mechanical agitation or ultrasonication. The property change associated with 1MN treatment was then analyzed using proximate analysis, calorific value analysis, Fourier transform infrared (FT-IR), X-ray photoelectron spectroscopy and moisture re-adsorption test. Susceptibility to spontaneous combustion was evaluated using crossingpoint temperature (CPT) measurement along with gas analysis by GC. A FT-IR profile showed that oxygen functional groups and C-H bonding became weaker when treated by 1 MN. XPS results also indicated a decrease of the oxygen groups (C-O-, C=O and COO-). Increased hydrophobicity was found in the 1MN treated coals during moisture readsorption test. A CPT of the treated coals was ${\sim}20^{\circ}C$ higher than that of the corresponding raw coals and the ultrasonication was more effective way to enhance the stability against spontaneous combustion than the agitation. In the gas analysis less CO and $CO_2$ were emitted from 1MN treated coals, also indicating inhibition of pyrophoric behavior. The surface functional groups participating in the oxidation reaction seemed to be removed by the ultrasonication more effectively than by the simple mechanical agitation.

A Study on Chemical Composition of Fine Particles in the Sungdong Area, Seoul, Korea (서울 성동구 지역 미세먼지의 화학적 조성에 관한 연구)

  • 조용성;이홍석;김윤신;이종태;박진수
    • Journal of Environmental Science International
    • /
    • v.12 no.6
    • /
    • pp.665-676
    • /
    • 2003
  • To investigate the chemical characteristics of PM$\_$2.5/ in Seoul, Korea, atmospheric particulate matters were collected using a PM$\_$10/ dichotomous sampler including PM$\_$10/ and PM$\_$2.5/ inlet during the period of October 2000 to September 2001. The Inductively Coupled Plasma-Mass Spectromety (ICP-MS), ion Chromatography (IC) methods were used to determine the concentration of both metal and ionic species. A statistical analysis was performed for the heavy metals data set using a principal component analysis (PCA) to derived important factors inherent in the interactions among the variables. The mean concentrations of ambient PM$\_$2.5/ and PM/sub10/ were 24.47 and 45.27 $\mu\textrm{g}$/㎥, respectively. PM$\_$2.5/ masses also showed temporal variations both yearly and seasonally. The ratios of PM$\_$2.5/PM$\_$10/ was 0.54, which similar to the value of 0.60 in North America. Soil-related chemical components (such as Al, Ca, Fe, Si, and Mn) were abundant in PM$\_$10/, while anthropogenic components (such as As, Cd, Cr, V, Zn and Pb) were abundant in PM2s. Total water soluble ions constituted 30∼50 % of PM$\_$2.5/ mass, and sulfate, nitrate and ammonium were main components in water soluble ions. Reactive farms of NH$_4$$\^$+/were considered as NH$_4$NO$_3$ and (NH$_4$)$_2$SO$_4$ during the sampling periods. In the results of PCA for PM$\_$2.5/, we identified three principal components. Major contribution to PM$\_$2.5/ seemed to be soil, oil combustion, unidentified source. Further study, the detailed interpretation of these data will need efforts in order to identify emission sources.

Fabrication of Gd2O2S:Tb fine scintillator film and evaluation of image quality for resolution improvement of X-ray imaging based on CMOS (CMOS 기반 X선 영상의 해상력 향상을 위한 Gd2O2S:Tb 미세형광체 필름 제작 및 영상 질 평가)

  • Kang, Sang-Sik;Choi, Young-Zoon;Jung, Bong-Jae;No, Si-Cheul;Cho, Chan-Hoon;Yoon, In-Chan;Park, Ji-Koon
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.5
    • /
    • pp.283-287
    • /
    • 2011
  • In this study, fine $Gd_2O_2S$:Tb powder was synthesized by using a low temperature solution-combustion method for a high-resolution digital x-ray imaging detector. From the fabricated phosphor power, the fine scintillator films was fabricated by particle sedimentation method and was investigated the luminescent property. From the experimental results of relative light output as a function of terbium concentration, the highest luminescent efficiency has at 5 wt% Tb concentration, and luminescent intensity decreased rapidly according to quenching effect about higher Tb concentration. Also, the relative light output of $270{\mu}m$-$Gd_2O_2S$:Tb film has 2945 pC/$cm^2$/mR. And light intensity was saturated at higher film thickness. Finally, to evaluate an image acquisition performance of fabricated phosphor, images were obtained by using commercial CMOS sensor and measured the MTF, NPS, and DQE. DQE(0 lp/mm) of fine phosphor film has 37%. But, DQE improvement of fine phosphor film is possible by resolving problem of film fabrication process and has a significant potential in the application of digital radiation imaging system later.

Characteristics of Ambient Particulate Matter in Gwangju (광주지역 먼지 특성에 관한 연구)

  • Seo, Gwang-Yeob;Kim, Seung-Ho;Lee, Kyoung-Seok;Min, Kyoung-Woo;Seo, Hee-Jeong;Kang, Yeong-Ju;Paik, Ke-Jin;Moon, Young-Woon;Shin, Dae-Yewn
    • Journal of Environmental Health Sciences
    • /
    • v.36 no.2
    • /
    • pp.108-117
    • /
    • 2010
  • In this study, ambient particulate matter ($PM_{2.5}$ and $PM_{10}$) levels were measured and their chemical and physical properties were characterized. Two sites in Gwangju were sampled once a month from December 2008 to November 2009. The annual mean concentrations of $PM_{2.5}$ and $PM_{10}$ were $26.9\;{\mu}g/m^3$ and $46.3\;{\mu}g/m^3$, respectively, in Nongseongdong and $26.1\;{\mu}g/m^3$ and $44.8\;{\mu}g/m^3$, respectively, in Duam-dong. $PM_{2.5}$ levels were 1.8 times higher than the USA Environmental Protection Agency (EPA) national ambient air quality standard for $PM_{2.5}$ ($15\;{\mu}g/m^3$). The average $PM_{2.5}/PM_{10}$ ratio of 0.58 suggested that $PM_{2.5}$ is a significant component of the ambient particle pollution. The order of concentration of metallic elements in $PM_{2.5}$ and $PM_{10}$ was Si > Al > Fe > Zn > Pb > Cu > Mn. Cd was not detected. The earth crustal enrichment factors for Cr, Cu, Pb and Zn in $PM_{2.5}$ were higher than those in $PM_{10}$. When the earth crustal enrichment factors for Cr, Cu, Pb and Zn were higher than 10, this suggested influence from anthropogenic sources. The soil contribution ratios for $PM_{2.5}$ and $PM_{10}$ were 11.3% and 16.4%, respectively, and were higher in the fall and winter. Anions (${SO_4}^{-2}$, ${NO_3}^-$, and $Cl^-$) comprise 28.7% of $PM_{2.5}$ and 21.4% of $PM_{10}$. The correlation coefficient of Zn-Fe, Mn-Cu, Fe-Cu and Fe-Mn in $PM_{2.5}$ was high in the sampling sites, and metallic elements were primarily from anthropogenic sources such as fuel combustion and vehicle emissions.

Energetic Thermoplastic Elastomers from Azidated Polyepichlorohydrin Rubber (Az-PECH)/ Styrene Acrylonitrile Copolymer (SAN) Blends (아지드화 폴리에피클로로히드린 고무/스티렌-아크릴로니트릴 공중합체 블렌드로부터 에너지함유열가소성탄성체 제조)

  • Choi, Myung-Chan;Chang, Young-Wook;Noh, Si-Tae;Kwon, Jung-Ok;Kim, Dong-Kook;Kwon, Soon-Kil
    • Applied Chemistry for Engineering
    • /
    • v.20 no.4
    • /
    • pp.375-380
    • /
    • 2009
  • Polyepichlorohydrin rubber was treated with sodium azide (Na$N_3$) to replace its chlorine by azide ($N_3$). Then, the azidated polyepichlorohydrin rubber (Az-PECH) was blended with thermoplastic styrene-acrylonitrile copolymer with the rubber/plastic ratio of 80/20, 70/30 and 60/40 (wt/wt). The miscibility, mechanical and dynamic mechanical properties as well as elastic recovery properties of the blends were evaluated by DMA (Dynamic Mechanical Analyzer) and tensile tests. When azidation level in azidated PECH was upto 50%, the blends exhibited excellent miscibility, manifested by a single $T_g$, and fairly good elastic recovery. When azidation level was 75%, the blends showed phase separation. The miscible Az-PECH/SAN blends exhibited typical thermoplastic elastomer like properties, ie. melt processibility and high extensibility as well as good elastic recovery rate. It was also observed from combustion test that higher energy is released with the increase in the azidation level of the Az-PECH in the blends.

A Comparative Study on PM10 Source Contributions in a Seoul Metropolitan Subway Station Before/After Installing Platform Screen Doors (서울시 지하철 승강장의 스크린도어 설치 전·후 PM10 오염원의 기여도 비교 연구)

  • Lee, Tae-Jung;Jeon, Jae-Sik;Kim, Shin-Do;Kim, Dong-Sool
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.26 no.5
    • /
    • pp.543-553
    • /
    • 2010
  • Almost five million citizens a day are using subways as a means of traffic communication in the Seoul metropolitan. As the subway system is typically a closed environment, indoor air pollution problems frequently occurs and passengers complain of mal-health impact. Especially $PM_{10}$ is well known as one of the major pollutants in subway indoor environments. The purpose of this study was to compare the indoor air quality in terms of $PM_{10}$ and to quantitatively compare its source contributions in a Seoul subway platform before and after installing platform screen doors (PSD). $PM_{10}$ samples were collected on the J station platform of Subway Line 7 in Seoul metropolitan area from Jun. 12, 2008 to Jan. 12, 2009. The samples collected on membrane filters using $PM_{10}$ mini-volume portable samplers were then analyzed for trace metals and soluble ions. A total of 18 chemical species (Ba, Mn, Cr, Cd, Si, Fe, Ni, Al, Cu, Pb, Ti, $Na^+$, $NH_4^+$, $K^+$, $Mg^{2+}$, $Ca^{2+}$, $Cl^-$, and ${SO_4}^{2-}$) were analyzed by using an ICP-AES and an IC after performing proper pre-treatments of each sample filter. Based on the chemical information, positive matrix factorization (PMF) model was applied to identify the source of particulate matters. $PM_{10}$ for the station was characterized by three sources such as ferrous related source, soil and road dust related source, and fine secondary aerosol source. After installing PSD, the average $PM_{10}$ concentration was decreased by 20.5% during the study periods. Especially the contribution of the ferrous related source emitted during train service in a tunnel route was decreased from 59.1% to 43.8% since both platform and tunnel areas were completely blocked by screen doors. However, the contribution of the fine secondary aerosol source emitted from various outside combustion activities was increased from 14.8% to 29.9% presumably due to ill-managed ventilation system and confined platform space.

Evaluating Possibility of Heavy Metal Accumulation by Fly Ash Application in Rice Paddy Soils (논토양에서 석탄회시용에 따른 중금속 축적가능성 평가)

  • Hong, Chang-Oh;Lee, Chang-Hoon;Lee, Hyup;Lee, Yong-Bok;Kim, Pil-Joo
    • Korean Journal of Environmental Agriculture
    • /
    • v.25 no.4
    • /
    • pp.331-338
    • /
    • 2006
  • Coal combustion fly ash, which has a high available Si content and alkaline pH, was selected as a potential source of soil amendment in this study. Two field experiments were carried out to evaluate the possibility of heavy metal accumulation in silt loam (Pyeongtaeg series) and loamy sand (Nagdong series) of rice (Oryza sativa) paddy soils to which 0, 40, 80, and $120Mg\;ha^{-1}$ of fly ash were added. Rice yields increased significantly with fly ash application and the highest rice yields were achieved following the addition of around $90Mg\;ha^{-1}$ fly ash. Fly ash increased the soil pH but did not increase heavy metal uptakes of rice and heavy metal concentration in soils, due to very low concentration of heavy metals in the selected fly ash. Labile fraction of heavy metals (exchangeable + acidic fraction) was scarcely contained and most of them were stable and unavailable form (oxidizable and residual fraction). In conclusion fly ash could be a good supplement to an inorganic soil amendments without heavy metal contamination in paddy soils.

Design and Construction Study of an Injection Facility for CO2 Offshore Storage (CO2 해상 지중저장을 위한 주입설비 설계 및 구축 연구)

  • Moon, Hung-Man;Kim, Hyo-Joon;Shin, Se-Jin;Lee, Yong-Il;Kwon, Si-Hyun;Kwon, Yi-Kyun
    • The Journal of Engineering Geology
    • /
    • v.28 no.2
    • /
    • pp.207-215
    • /
    • 2018
  • Almost all countries of the world have recently made great efforts to reduce green-house gases to alleviate the global warming threatening human survival, because a huge amount of carbon dioxide as one of the main green-house gases has been emitted from the combustion processes of fossil fuels such as coal and oil. $CO_2$ capture and storage (CCS) technology is a representative method to diminish the green-house gases, and actively investigated by many countries. This study focuses on the design and construction of a high pressure $CO_2$ injection facility to store it to underground, which is the first $CO_2$ injection in Korea following the steps of the $CO_2$ capture from large $CO_2$ emission sources and transportation to the sea. Injection tests of $CO_2$ on the platform on the sea were carried out in Yeongil Bay of Pohang city in the early 2017. Thus, we were able to perceive the necessary operating conditions of the injection facility, injection characteristic, and knowhow of the injection facility. The results obtained from the injection test shall be utilized for facility upgrades and scale-ups.

Identification of Atmospheric PM10 Sources and Estimating Their Contributions to the Yongin-Suwon Bordering Area by Using PMF (PMF모델을 이용한 용인.수원 경계지역에서 PM10 오염원의 확인과 상대적 기여도의 추정)

  • Lee, Hyung-Woo;Lee, Tae-Jung;Yang, Sung-Su;Kim, Dong-Sool
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.24 no.4
    • /
    • pp.439-454
    • /
    • 2008
  • The purpose of this study was to extensively identify $PM_{10}$ sources and to estimate their contributions to the study area, based on the analysis of the $PM_{10}$ mass concentration and the associated inorganic elements, ions, and total carbon. The contribution of $PM_{10}$ sources was estimated by applying a receptor method because identifying air emission sources were effective way to control the ambient air quality. $PM_{10}$ particles were collected from May to November 2007 in the Yongin-Suwon bordering area. $PM_{10}$ samples were collected on quartz filters by a $PM_{10}$ high-volume air sampler. The inorganic elements (Al, Mn, V, Cr, Fe, Ni, Cu, Zn, Cd, Pb, Si, Ba, Ti and Ag) were analyzed by an ICP-AES after proper pre-treatments of each sample. The ionic components of these $PM_{10}$ samples ($Cl^_$, $NO_3^-$, $SO_4^{2-}$, $Na^+$, $NH_4^+$, $K^+$, $Ca^{2+}$, and $Mg^{2+}$) were analyzed by an IC. The carbon components (OC1, OC2, OC3, OC4, OP, EC1, EC2 and EC3) were also analyzed by DRI/OGC analyzer. Source apportionment of $PM_{10}$ was performed using a positive matrix factorization (PMF) model. After performing PMF modeling, a total of 8 sources were identified and their contribution were estimated. Contributions from each emission source were as follows: 13.8% from oil combustion and industrial related source, 25.4% from soil source, 22.1% from secondary sulfate, 12.3% from secondary nitrate, 17.7% from auto emission including diesel (12.1%) and gasoline (5.6%), 3.1% from waste incineration and 5.6% from Na-rich source. This study provides information on the major sources affecting air quality in the receptor site, and therefore it will help us maintain and manage the ambient air quality in the Yongin-Suwon bordering area by establishing reliable control strategies for the related sources.

A Study on the Design Concept & Construction Method of Office Building with Stacks at Thermal Power Plant (화력발전소 연돌통합형 종합사무동의 설계개념과 시공공법 연구)

  • Kim, Si-Hyun;Choi, Jang-Soon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.7
    • /
    • pp.677-686
    • /
    • 2016
  • A thermal power plant is the first CFBC (Circulating Fluidized Bed Combustion) power plant consisting of 2 boilers-1 turbine. The optimal height of a stack needs to be approximately 156 meters in the case of this thermal power plant; however, the thermal power plant sites satisfy a function and reduce the construction cost by using mountains in the sites after cutting the ground and locating an integrated office and chimney at an altitude of 70 meters thereby lowering the height of the stack to 86 meters. In addition, the integrated office, which has a combined stack style with a unique design, is constructed by connecting with 2 stacks and disposing the office and an observatory in the space between them. Therefore, this study examined the design concept that fulfils the structural, functional, and aesthetic factors, harmoniously by joining the integrated office and the stack, which are disparate, and investigated special construction methods (Slip Form, Steel Inner Flue & Lift-up) through which heterogeneous architectures are structurally, functionally, and aesthetically constructed.