• Title/Summary/Keyword: SCREEN TEST

Search Result 627, Processing Time 0.03 seconds

Design and Test of ASME Strainer for Coolant System of Research Reactor (연구용 원자로 냉각계통의 ASME 스트레이너 설계 및 성능시험)

  • Park, Yong-Chul;Park, Jong-Ho
    • The KSFM Journal of Fluid Machinery
    • /
    • v.2 no.3 s.4
    • /
    • pp.24-29
    • /
    • 1999
  • The ASME strainers have been newly installed at the suction side of each reactor coolant pump to get rid of the foreign materials which may damage the pump impeller or interfere with the coolant path of fuel flow tube or primary plate type heat exchanger. The strainer was designed in accordance with ASME SEC. III, DIV. 1, Class 3 and the structural integrity was verified by seismic analysis. The screen was designed in accordance with the effective void area from the result of flow analysis for T-type strainer. After installation of the strainer, it was confirmed through the field test that the flow characteristics of primary cooling system were not adversely affected. The pressure loss coefficient was calculated by Darcy equation using the pressure difference through each strainer and the flow rate measured during the strainer performance test. And these are useful data to predict flow variations by the pressure difference.

  • PDF

Long-Term Life Test of A Stainless Steel-Sodium Heat Pipe (스테인리스 스틸-나트륨 히트파이프의 장기 수명 시험)

  • Park, S.Y.;Jung, E.G.;Boo, J.H.;Kang, H.K.;Yoo, J.H.;Park, S.H.
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.1058-1062
    • /
    • 2004
  • High-temperature cylindrical stainless steel/sodium heat pipe was manufactured and tested under long-term operation. The container material was stainless steel 316L and the working fluid was sodium. The heat pipe was 25.4 mm in diameter and 1000 mm in length with a two-layer screen mesh wick. The evaporator part was 600 mm and the condenser part was 300 mm in length. Total measurement points on heat pipe were 15 points and 12 points were located in condenser part. The heat pipe was heated for 142 days(3400 hours) at $800^{\circ}C$. In the test period, the maximum temperature difference was increased from $18^{\circ}C$ o $28^{\circ}C$ and the maximum thermal resistance was as low as $0.015^{\circ}CW$.

  • PDF

Micro Scale Mechanical property of Polymeric materials for FPD(Flat Panel display) (FPD에 사용되는 고분자 재료의 기계적 물성특성 연구)

  • Lee N.K.;Lee H.J.;Lee H.W.;Chong E.G.;Choi D.S.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.220-224
    • /
    • 2005
  • The technology trend of Flat Panel Display (FPD) equipments have been demanded that there are compact and multi-function. Therefore, nano/micro scale patterned on polymeric materials of Back Light Unit (BLU) in Liquid Crystal Display (LCD) that has been investigated. This paper describes a series of Horizontal Type Micro Tensile Tester that were carried out to investigate the load strain distance performance of typical polymeric material sheets. The polymeric materials film that micro size shaped specimens for tensile test are used by Cold-Isostatic-Press (CIP). Test equipment is Horizontal type Micro Tensile Tester that is presented to measure the micro scale mechanical property of thin film for FPD. This paper presents which easy testing tools measure for micro patterned on polyethylene (PET) specimens.

  • PDF

Study on the annoyance response of subway station noise using jury evaluation test (청감실험을 통한 도시철도 승강장 소음의 성가심 반응에 대한 연구)

  • Kim, Dong-Jun;Kim, Deuk-Sung;Son, Jin-Hee;Chang, Seo-Il
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2009.04a
    • /
    • pp.670-677
    • /
    • 2009
  • The purpose of this study is to reveal the quantitative dose-response relationship between the noise emitted in the platform of subway station and the public response. The noise measured in the platform of subway station was used for a jury test. In order to find the factors which influence annoyance response due to the platform noise, jurors were examined for the difference of the annoying response, interrelation of sound quality parameter and annoyance response. The platform noise level was 77.2$\sim$83.9 dBA and the most of passengers at the platform were highly annoyed. And screen door contributes to annoyance reduction of platform noise. The results from analyzing sound quality parameters shows that loudness and annoyance response have a high correlation coefficient.

  • PDF

DVB-T PSI(Program Specific Information) Parser using Design of Ali M3330 MPEG-2 decoder processor (ALi M3330 MPEG-2 디코더 프로세서를 이용한 DVB-T PSI(Program Specific Information) 해석기 설계)

  • Jun, Do-Young;Kim, Min-Sung;Kim, Su-Hyun;You, Hong-Yean;Hong, Sung-Hoon
    • Proceedings of the KIEE Conference
    • /
    • 2007.04a
    • /
    • pp.278-280
    • /
    • 2007
  • In this paper, wd design the Program Specific Information (PSI) parser and its On-Screen Display (OSD) on the middleware of ALi M3330 MPEG-2 decoder processor to analyze DVB-T Transport Stream(TS) information. To test the functional operation of the designed parser, we implement the DVB-T test board including the RF-tuner using ALi M3330 MPEP-2 decoder processor and confirm the correct operation using the input TS stream generated by DVB-T stream generator. The developed PSI parser could be used for the test environment, various channel extension, and the development of DVB-T reception module.

  • PDF

A study on Enterotoxigenic Escherichia coli (대장균의 장내 독소 생성 균주에 관한 연구)

  • 이영남
    • Korean Journal of Microbiology
    • /
    • v.16 no.4
    • /
    • pp.161-169
    • /
    • 1978
  • Escherichiae-like organisms were isolated from rectal specimens of 56 children who were either in preschool age or in elementary school. The isolated strains were subjected to tests to screen enteropathogens producing heat-labile enterotoxin and susceptibility test to various antibiotics by disc diffusion method on agar plates. Production of heat-labile enterotoxin by the strains was assyed in the sensitive and reproducible cultured adrenal tumor cell system. The assay was sterodogenesis of the cell in the presence of heat-labile enterotoxin. Among 56 strains, gave positive reaction in the test of toxin production. This meant that about 10% of the children population objected to the study harbored the toxigenic strain of enteropathogenes. Some of these toxigenic strains were resistant to the antibiotics employed in the test. This study suggested that considerable population in Korea may harbor entertoxigenic E. coli as a part of intestinal normal flora. The toxigenic strains which are resistant to antibiotics may bring issue of public health in the future.

  • PDF

Integer Programming Approach to the Convergence Adjustment on Color Display Tube

  • Park, Sungsoo;Kang, Donghan;Lee, Hyohyung;Hong, Cheol-Kee
    • Industrial Engineering and Management Systems
    • /
    • v.3 no.1
    • /
    • pp.63-70
    • /
    • 2004
  • In this paper, we consider the adjustment of convergence on Color Display Tube (CDT). Convergence is a measure of how well the red, green and blue beams are physically aligned with each other to strike the same area on the screen. When misconvergence (convergence error) occurs, one way of compensating it is to attach several ferrite sheets on the inner part of Deflection Yoke (DY). We suggest an optimization model of misconvergence compensation process and report test results for 81 DY samples. As a result, more than 90% of the samples could be made to satisfy the required convergence criteria.

Inlet Distortion Test of Gas Turbine Engine (가스터빈 엔진의 입구 유동 왜곡 시험)

  • Lee, Jin-Kun;Lee, Kyung-Jae
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2007.04a
    • /
    • pp.339-345
    • /
    • 2007
  • Inlet distortion test was performed at Korea Aerospace Research Institute in order to evaluate the degradation of engine performance under the distorted inlet condition. In this paper, only the inlet pressure distortion was taken into consideration. During the development process of the inlet distortion test technique, variable distortion screen was designed and evaluated under various test conditions to establish the experimental database of distortion for engine test. The result of inlet distortion test for engine shows that the operating point was changed toward the worse direction and the degradation of engine performance by inlet distortion was verified.

  • PDF

The Optimal Letter Spacing and Line Spacing of Korean on the Visual Display (VDT 화면에서의 한글 자간간격과 행간간격에 관한 연구)

  • 황우상;부진후;이동춘
    • Proceedings of the ESK Conference
    • /
    • 1998.04a
    • /
    • pp.161-166
    • /
    • 1998
  • In this study, the optimum criteria of space between the lines and the letters which could largely affect the legibility were found by the experiment and were presented as guidelines to design Korean VDT screens. Since the experiment was designed to test the human performance based on the VDT screen design, searching speed (S.S) and error rate (E) were used as the criteria of performance, and CFF value was measured to evaluate user's visual fatigue. The EOG value was also measured for the visual restriction during the experiment for the space between the lines and letters.

  • PDF

광식각 기술을 이용한 미세라인의 형성 및 Series Resonator의 구현

  • 박성대;조현민;이영신;이우성;박종철
    • Proceedings of the International Microelectronics And Packaging Society Conference
    • /
    • 2001.07a
    • /
    • pp.151-156
    • /
    • 2001
  • Using the photoimageable thick film conductors, $25\mu\textrm{m}$ line widths and $25\mu\textrm{m}$ spaces can be obtained. Test patterns are made by green tape lamination, paste printing, exposing to UV light, developing in an aqueous process and cofiring. Postfiring method using alumina substrate can be also applied to fine line formation. Series gap resonator formed by photopatterning process showed the improved signal transmission characteristics compared to that obtained by conventional screen printing.

  • PDF