Operation and Configurgation of Superconducting Machines and Devices in Utility System (초전도전력설비의 구성 및 운전)

  • 홍원표;이원규;곽희로
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 1996.11a
    • /
    • pp.116-121
    • /
    • 1996
  • An image of future power system which has introduced superconducting generator, cable, transformer, fault current limiter, SMES and so on is presented. Conceptual designs of each SC machines and devices are carried out. The SC cable and SFCL utilize the high Tc superconductor(HTS) cooled by liquid $N_2$Other devices use low temperature superconducting cooled by He. The SC power system models are proposed detailedly. In viewpoint of the operation and control SC power system, The concrete design direction and effective role of each SC apparatus are investigated. In this paper, it is pointed that superconducting fault limiters(SFCLs) should play an important part of the quenching current level coordination to prevent the other SC devices from quenching. Finially, SFCL are also expected to he very effective to introduce flexibility of power system configuration and operation due to their possibility to enhance transient stability and reduce short circuit current.

  • PDF

The Operating Method of Superconducting Fault Current Limiter for Total Superconducting Power System (초전도전류제한기의 초전도 전력시스템에서의 운전방안)

  • Hong, Won-Pyo
    • Proceedings of the KIEE Conference
    • /
    • 1996.07b
    • /
    • pp.764-767
    • /
    • 1996
  • Design & operation of power system for meeting increase of electric power demands is becoming more difficult and complex. One of reasons is increase of fault current. As one of the most effective methods for suppressing the fault currents, installation of SFCL are expected. An image of future hybrid & total SC power system which have introduced SC generator cable transformer, fault current limiter, SMES & shunt reactor, etc. are presented. In the SC power system, it is pointed that a SFCL should play an, important part of quenching current level coordination to prevent the other SC devices from quench.

  • PDF

The Development of the Turbo Generator System with Direct Driving High Speed Generator (고속 발전기 직접 구동 방식의 터보 제너레이터 시스템 개발)

  • 노민식;박승엽
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.40 no.6
    • /
    • pp.87-94
    • /
    • 2003
  • This paper presents results of the development of the turbo generator system with structure which is HSG(High Speed Generator) installed directly to gas-turbine engine. Turbo generator with a high speed motor-generator directly has many advantages aspects of weight, size, lubrication system and complexity of the system compared of conventional turbo generator system with a gear box. But because of direct high speed operation of the high speed generator, we have to need stable high speed motor driving algorithm for perfect engine ignition when engine start. Also we have to need the design of the Power conditioning unit(PCU) for converting high speed AC output power to conventional AC power or needed DC power.

Research on Fault Diagnosis of Wind Power Generator Blade Based on SC-SMOTE and kNN

  • Peng, Cheng;Chen, Qing;Zhang, Longxin;Wan, Lanjun;Yuan, Xinpan
    • Journal of Information Processing Systems
    • /
    • v.16 no.4
    • /
    • pp.870-881
    • /
    • 2020
  • Because SCADA monitoring data of wind turbines are large and fast changing, the unbalanced proportion of data in various working conditions makes it difficult to process fault feature data. The existing methods mainly introduce new and non-repeating instances by interpolating adjacent minority samples. In order to overcome the shortcomings of these methods which does not consider boundary conditions in balancing data, an improved over-sampling balancing algorithm SC-SMOTE (safe circle synthetic minority oversampling technology) is proposed to optimize data sets. Then, for the balanced data sets, a fault diagnosis method based on improved k-nearest neighbors (kNN) classification for wind turbine blade icing is adopted. Compared with the SMOTE algorithm, the experimental results show that the method is effective in the diagnosis of fan blade icing fault and improves the accuracy of diagnosis.

A Study of Wind Energy Conversion System by a Secondary Control Hydrostatic Transmission (2차측 제어 정유압 변속기를 이용한 풍력발전시스템에 관한 연구)

  • Do, H.T.;Ahn, K.K.
    • Journal of Drive and Control
    • /
    • v.10 no.1
    • /
    • pp.21-28
    • /
    • 2013
  • Wind energy has been more and more important and contributive in the energy utilization of the world. This paper proposed a novel method for Wind Energy Conversion System (WECS), in which a secondary control hydrostatic transmission (SC-HST) with two hydraulic accumulators, were employed for wind energy conversion system. This approach can absorb the excessive power of turbine, keep the generator from over-speed and maintain the speed of generator in low speed of turbine. A PID controller was designed for speed control to track a predefined speed. The simulation results indicated that the speed of the generator was ensured with the relative error less than 2%; and the efficiency of the proposed system was 70.4%.

60 GHz Optical Carrier Generator using Quasi-Velocity-Matching Technique (Quasi-Velocity-Matching물 이용한 60 GHz 광캐리어 발생기)

  • Kim, W.K.;Yang, W.S.;Lee, H.M.;Lee, H.Y.;Jeong, W.J.;Kwon, S.W.
    • Korean Journal of Optics and Photonics
    • /
    • v.17 no.2
    • /
    • pp.181-185
    • /
    • 2006
  • A novel 60GHz optical carrier generator with a polarization domain-inverted structure is suggested and is demonstrated. The two arms of the Mach-Zehnder optical waveguide are periodically poled for quasi-phase velocity matching between the optical wave at 1550nm and the RF wave at 30 GHz. The center frequency of band-pass modulation and the 3 dB bandwidth of the fabricated modulator were measured to be 30.3 GHz and 5.1 GHz, respectively. Sub-carriers with the frequency difference of 60GHz waeregenerated under appropriate DC biac voltage application while the carrier was suppressed to lead to the power ratio between the modulated sub-carrier and the suppressed fundamental carrier of 28 dB, which proves that double sideband- suppressed carrier(DSB-SC) operation can be realized by the suggested single device.

Regenerative Energy Characteristics of Battery and Supercapacitor in a PEMFC Hybrid System

  • Kim, Byeong Heon;Wei, Qingsheng;Oh, Byeong Soo
    • Journal of Power System Engineering
    • /
    • v.21 no.4
    • /
    • pp.5-17
    • /
    • 2017
  • This study focuses on the application of the PEM Fuel Cell(PEMFC) hybrid system, which includes a regenerative braking system with supercapacitor(SC) and battery. The purpose of this study is to evaluate the characteristics of regenerative energy and to propose solutions to increase regenerative energy via vehicle simulation. To achieve this target, we set the rated motor speed to 3,000/2,500/2,000 rpm. Because the flywheel is directly connected to the motor, the generator activates regenerative braking by using the rotational momentum of the flywheel when the flywheel reaches the set speed after the motor stops. We could then measure the characteristics of regenerative braking of voltage, current, power, energy change, etc. Meanwhile, we calculate the storage efficiency of the SC or the battery. Our results show that the SC stores 18% of the regenerative energy, while battery stores 15% of the energy. Since the regenerative energy decreases with the decrease of the motor rotating speed that 5,027 J and 2,915 J are restored at 3,000 and 2,500 rpm, respectively. The experimental results also prove that regenerative braking energy is able to be obtained if and only if the speed of flywheel is over 2,500 PRM, and the efficiency of the system can be further improved.

A Configuration of Superconducting Power System Considering the Current Level & Electric Insulation Coordination of Superconducting Apparatus (초전도기기 전류레벨협조와 절연협조를 고려한 초전도전력시스템구성을 위한 기초연구)

  • Hong, W.P.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07c
    • /
    • pp.1208-1210
    • /
    • 1999
  • Design & operation power systems for meeting increase of electric power demand is becoming more difficult and complex. Some of limitations of conventional technology can be broken through by the application of superconductivity technology. This paper presents a new concept & image for the configuration of superconducting power system which has introduced superconducting(SC) generator, cable, transformer, fault current limiter(SFCL), SMES, etc. Engineering evaluation of each power apparatus and its assessment of application to power system were conducted. Futhermore, it is pointed that superconducting power system require a new operating condition. This is, SFCL should play a important part of quenching current level coordination to prevent the other superconducting devices from quenching. Its designing & operating condition including SFCL was discussed in viewpoint of quenching current level and insulation coordination of SC coil.

  • PDF

Development of Frequency Weighing Sensor and Single Crystal Growth (새로운 무게센서 재발과 단결정성장(1))

  • Jang Y.N.;Sung N.H.;Chae S.C.;Bae I.K.;Kim I.J.
    • Korean Journal of Crystallography
    • /
    • v.8 no.1
    • /
    • pp.38-47
    • /
    • 1997
  • A new weighing sensor for the automatic diameter control system of the crystal growth is developed in this study. This weighing sensor measures the frequency of the vibrating element which is lineally changing with respect to weight. The signal and the power of this system are transmitted without any physical contact, so that this sensor offers high accuracy and resolution. This system consists of a string, a sinusoidal wave generator, an automatic amplification adjusting circuit, signal transformers and a PCB. 4 kinds of programs are developed for checking DAC, weight calibration and controlling growth process. The measurements of the standard deviation and the resolution show $\pm0.10g$(measured at every second) and $5{\times}10^{-5}$, respectively, This weighing sensor is effective under high pres-sure of 200 atm, high temperature and vacuum condition. The weighing system can control the temperature in the accuracy of $\pm0.025^{\circ}C$ with the 'signal divider'. The optical quality single crystals of $(YGd)_3Sc_2Ga_3O_{12},\;Er-Y_3Sc_2Al_3O_{12},\;and\;Bi_{12}GeO_{20}$ have been grown by Czo-chralski method using this auto-diameter control system.

  • PDF

Linearity Improvement of Doherty Amplifier Using Analog Predistorter with Phase-Controlled Error Generator (위상조절 왜곡발생기를 가진 아날로그 전치왜곡기를 이용한 Doherty Amplifier의 선형성 개선)

  • Lee, Yong-Sub;Jeong, Yoon-Ha
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.44 no.2 s.314
    • /
    • pp.32-38
    • /
    • 2007
  • This paper represents a Doherty amplifier (DPA) with analog predistorter (PD) to improve the linearity of the DPA while preserving the high efficiency. A third-order PD cancels fifth-order intermodulation (IM5) as well as third-order intermodulation (IM3) components by their same phase difference in the PD and DPA. This is accomplished by independently controlling their phase by using the phase-controlled error generator in the PD. Also, we confirm the phase-control ability of the error generator experimentally with a simple and accurate phase measurement setup. For experimental verification, a third-order PD has been implemented and tested in a 180-W DPA at the wide-band code division multiple access (WCDMA) band of 2.11-2.17 GHz. Two-tone test results show that significant cancellation of IM3 and IM5 components can be obtained. For four-carrier WCDMA applications, significant adjacent channel leakage ratio (ACLR) improvement is achieved over a wide range of output power levels. This technique is cost-effective and convenient due to its simple structure, compact size, and three control parameters.