• Title/Summary/Keyword: S-Parameter Measurement

Search Result 379, Processing Time 0.028 seconds

A Simple and Accurate Parameter Extraction Method for Substrate Modeling of RF MOSFET (간단하고 정확한 RF MOSFET의 기판효과 모델링과 파라미터 추출방법)

  • 심용석;양진모
    • Proceedings of the Korea Society of Information Technology Applications Conference
    • /
    • 2002.11a
    • /
    • pp.363-370
    • /
    • 2002
  • A substrate network model characterizing substrate effect of submicron MOS transistors for RF operation and its parameter extraction with physically meaningful values are presented. The proposed substrate network model includes a single resistance and inductance originated from ring-type substrate contacts around active devices. Model parameters are extracted from S-parameter data measured from common-bulk configured MOS transistors with floating gate and use where needed with out any optimization. The proposed modeling technique has been applied to various-sized MOS transistors. Excellent agreement the measurement data and the simulation results using extracted substrate network model up to 30GHz.

  • PDF

A Simple and Accurate Parameter Extraction Method for Substrate Modeling of RF MOSFET (간단하고 정확한 RF MOSFET의 기판효과 모델링과 파라미터 추출방법)

  • 심용석;양진모
    • Proceedings of the Korea Society for Industrial Systems Conference
    • /
    • 2002.11a
    • /
    • pp.363-370
    • /
    • 2002
  • A substrate network model characterizing substrate effect of submicron MOS transistors for RF operation and its parameter extraction with physically meaningful values are presented. The proposed substrate network model includes a single resistance and inductance originated from ring-type substrate contacts around active devices. Model parameters are extracted from S-parameter data measured from common-bulk configured MOS transistors with floating gate and use where needed with out any optimization. The proposed modeling technique has been applied to various-sized MOS transistors. Excellent agreement the measurement data and the simulation results using extracted substrate network model up to 30㎓

  • PDF

On the Surface Moisture Availability Parameters to Estimate the Surface Evaporation (증발량 추정을 위한 지표면 가용 수분 계수)

  • 황병화;황수진
    • Journal of Environmental Science International
    • /
    • v.4 no.5
    • /
    • pp.427-435
    • /
    • 1995
  • In order to discuss the differences among the SMP(Surface Moisture Availability Parameter), by previous researchers on the basis of their own theoretical and empirical background, we assessed the SMP according to the soil types and volumetric soil water contents. The results are as follows. There are differences among all the five SMAPs. There's a tendency that the larger grain size, the higher value of parameters. And they divided into two groups for their value: one group has parameters with exponential function and the other with cosine and linear function. The maximum difference between the two groups appears when the volumetric soil water contents are 0.07m3m-3 for sand, 0.l1m3m-3 for loam, 0.12 for clay, and 0.13m3m-3 for silt loam. So, these differences must be considered when we estimate the surface evaporation rate. From field data, the paddy field soil around Junam reservoir is classified as a silt has high wetness, 0.56. So, the parameter obtained from the field measurement is much higher than that of Clapp and Hornberger(1978)'s Table. This study treated the SMP for a certain point of time in winter season. But if we measured the soil water contents continuously, we could obtain better time-dependent parameter. Key words : SMAP(Surface Moisture Availability Parameter), Paddy field, Volumetric soil water content, Evaporation, Capillary potential.

  • PDF

Quality Level Classification of ECG Measured using Non-Constraint Approach (무구속적 방법으로 측정된 심전도의 신뢰도 판별)

  • Kim, Y.J.;Heo, J.;Park, K.S.;Kim, S.
    • Journal of Biomedical Engineering Research
    • /
    • v.37 no.5
    • /
    • pp.161-167
    • /
    • 2016
  • Recent technological advances in sensor fabrication and bio-signal processing enabled non-constraint and non-intrusive measurement of human bio-signals. Especially, non-constraint measurement of ECG makes it available to estimate various human health parameters such as heart rate. Additionally, non-constraint ECG measurement of wheelchair user provides real-time health parameter information for emergency response. For accurate emergency response with low false alarm rate, it is necessary to discriminate quality levels of ECG measured using non-constraint approach. Health parameters acquired from low quality ECG results in inaccurate information. Thus, in this study, a machine learning based approach for three-class classification of ECG quality level is suggested. Three sensors are embedded in the back seat, chest belt, and handle of automatic wheelchair. For the two sensors embedded in back seat and chest belt, capacitively coupled electrodes were used. The accuracy of quality level classification was estimated using Monte Carlo cross validation. The proposed approach demonstrated accuracy of 94.01%, 95.57%, and 96.94% for each channel of three sensors. Furthermore, the implemented algorithm enables classification of user posture by detection of contacted electrodes. The accuracy for posture estimation was 94.57%. The proposed algorithm will contribute to non-constraint and robust estimation of health parameter of wheelchair users.

VBIC Model Application and Parameter Extraction and Optimization for SiGe HBT

  • Lee, Sang-Heung;Park, Chan-Woo;Lee, Seung-Yun;Lee, Ja-Yol;Kang, Jin-Yeong
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.28 no.8A
    • /
    • pp.650-656
    • /
    • 2003
  • In 1995, a group of representatives from the integrated circuits and computer-aided design industries presented a industry standard bipolar model called the VBIC model. The VBIC model includes the improved Early effect, quasi-saturation, substrate parasitic, avalanche multiplication, and self-heating which are not available in the conventional SGP model. This paper applies VBIC model for SiGe HBT device and develops an accurate and efficient methodology to extract all the DC and AC parameters of the VBIC model for SiGe HBT device at room temperature. Simulated results by the extracted VBIC model parameter are compared with the measurement data and show very good agreement in both DC and s-parameters prediction.

Meter Optimal Placement in Measurement System with Phasor Measurement Unit (페이저 측정 시스템의 측정기 최적배치)

  • Kim, Jae-Hoon;Cho, Ki-Seon;Kim, Hoi-Cheol;Shin, Joong-Rin
    • Proceedings of the KIEE Conference
    • /
    • 1999.07c
    • /
    • pp.1195-1198
    • /
    • 1999
  • This paper presents optimal placement of minimal set of phasor measurement units(PMU's) and observability of measurement system with PMU. By using the incidence matrix symbolic method which directly assigns measurement and pseudo-measurement to incidence matrix, it is much simpler and easier to analyze observability. The optimal PMU set is found through the simulated-annealing(SA) and the direct combinational method. The cooling schedule parameter which is suitable to the property of problem to solve is specified and optimal placement is proven by presented direct combinational method. Search spaces are limited within reasonable feasible solution region to reduce a unnecessary one in the SA implementation based on global search. The proposed method presents to save CPU time and estimate state vectors based on optimal PMU set.

  • PDF

Gate Capacitance Measurement on the Small-Geometry MOSFET's with Bias (Small-Geometry MOSFET에서 Bias에 따른 게이트 Capacitance 측정)

  • 김천수;김광수;김여환;이진효
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.24 no.5
    • /
    • pp.818-822
    • /
    • 1987
  • Gate capacitances have been measured directly on small-geometry MOSFET's with the drain voltage as a parameter for various channel lengths and for p and n channel types and the characteristics have been compared with each other. The influence of 'hot carrier effect' of short channel devices on capaciatance has been compared with long channel devices. The results show that gate capacitance characteristics of short channel device deviate from those of long channel device. The accuracy of the measurement system is less than a few femto Farad, and the minimum geometry (W/L) of device for which reliable measurement can be obtained is 6/3.

  • PDF

Prediction of Settlement for the Highly Plastic and Silty Soft Ground Contained of the Organic Deposits (유기질층을 포함한 고소성 실트질 연약지반의 침하 예측)

  • Yoo, Nam-Jae;Kim, Kyum;Yoo, Chang-Sun
    • Journal of Industrial Technology
    • /
    • v.31 no.B
    • /
    • pp.91-98
    • /
    • 2011
  • In this thesis, from the results of settlement measurement performed at the site where embankment earthwork was carried out on the ground consisting of highly plastic and silty soft soils interlayered with organic deposits, various methods of predicting the embankment settlement such as Hoshino's method, Asaoka's method, hyperbolic method, ${\sqrt{s}}$ method and Monden's method were used to investigate their applicability and the inverse method of finding the soil parameter related to consolidation was used to predict the consolidation behavior in the future. It was confirmed that reliable prediction of consolidation behavior under various conditions could be done to estimate soil parameter related to consolidation such as the consolidation index and consolidation coefficient by the inverse method of comparing the measured settlement with the predicted value by the settlement prediction methods.

  • PDF

Gauge Capability Analysis and Designed Experiments (계측기 능력분석과 실험계획법)

  • Baik, Jaiwook;Jo, Jinnam
    • Journal of Korean Society for Quality Management
    • /
    • v.24 no.3
    • /
    • pp.145-159
    • /
    • 1996
  • In today's organization, measurement plays a crucial role in helping improve process or quality. In this paper, we review the measurement error study, classical gauge repeatability and reproducibility study, and designed experiment suited for the determination of the measurement capability. Measurement error study is very simple to use but is rather crude. Hence, it should be used as a preliminary study to determine whether further study is necessary. Classical gauge repeatability and reproducibility (GR&R) study is the most common technique for evaluation of gauge capability. It calculates a percentage that relates the repeatability, reproducibility, and overall R&R to the specification range for the parameter measured. Hence, the individual repeatability and reproducibility statistics will indicate the area on which to concentrate. However, GR&R study only gives a point estimate of each component, which leaves a room for improvement. It is always good to integrate the use of control charts to ascertain the statistical stability of the measurement process. The tools of statistical experimental design are available for a comprehensive design and analysis of the measurement process. Hence, in this paper, we present gauge capability analysis as an experimental design problem and compare it with the classical GR&R study.

  • PDF

Measurement of Multi-Port S-Parameters using Four-Port Network Analyzer

  • Kim, Jongmin;Luong, Duc Long;Nah, Wansoo;Kim, SoYoung
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.13 no.6
    • /
    • pp.589-593
    • /
    • 2013
  • An efficient measurement methodology is proposed to construct the scattering parameters of a multi-port device using a four-port vector network analyzer (VNA) without the external un-terminated ports. By using the four-port VNA, the reflected waves from the un-terminated ports could be minimized. The proposed method significantly enhances the accuracy of the S-parameters with less number of measurements compared to the results of classical renormalization technique which uses two-port VNA. The proposed method is validated from the measured data with the coupled 8-port micro-strip lines.