• 제목/요약/키워드: Rotational angle

검색결과 434건 처리시간 0.024초

Study on transient performance of tilting-pad thrust bearings in nuclear pump considering fluid-structure interaction

  • Qiang Li;Bin Li;Xiuwei Li;Quntao Xie;Qinglei Liu;Weiwei Xu
    • Nuclear Engineering and Technology
    • /
    • 제55권6호
    • /
    • pp.2325-2334
    • /
    • 2023
  • To study the lubrication performance of tilting-pad thrust bearing (TPTBs) during start-up in nuclear pump, a hydrodynamic lubrication model of TPTBs was established based on the computational fluid dynamics (CFD) method and the fluid-structure interaction (FSI) technique. Further, a mesh motion algorithm for the transient calculation of thrust bearings was developed based on the user defined function (UDF). The result demonstrated that minimum film thickness increases first and then decreases with the rotational speed under start-up condition. The influence of pad tilt on minimum film thickness is greater than that of collar movement at low speed, and the establishment of dynamic pressure mainly depends on pad tilt and minimum film thickness increases. As the increase of rotational speed, the influence of pad tilt was abated, where the influence of the moving of the collar dominated gradually, and minimum film thickness decreases. For TPTBs, the circumferential angle of the pad is always greater than the radial angle. When the rotational speed is constant, the change rate of radial angle is greater than that of circumferential angle with the increase of loading forces. This study can provide reference for improving bearing wear resistance.

2축 안정화 시스템에서 zero-crossing을 이용한 영상 안정화 (Digital Image Stabilization in the 2-axes Stabilization System using Zero-crossing of the Rotational Motion)

  • 김동노;김기홍;정태연;권영도;김덕규
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 학술회의 논문집 정보 및 제어부문 B
    • /
    • pp.396-399
    • /
    • 2003
  • This paper proposes a simple digital image stabilization(DIS) algorithm for roll motion, which has not been compensated in the 2-axes mechanical stabilization system, using aero-crossing of the rotational motion vectors. The 2-axes stabilization system cannot stabilize rolled images, which causes the deteriorated performance of the object detection and recognition. In this paper, we propose the rotational motion stabilization algorithm which estimates and compensates global motion in terms of rotational center and rotational angle. Both the synthetic images with undesirable rotational disturbance and the real images from 2-axes stabilization system are used to evaluate the proposed algorithm. The results show that our proposed algorithm suppresses the undesirable rotational disturbance effectively.

  • PDF

비원형기어를 이용한 부등속 회전기구의 설계 변수에 관한 연구 (Determination of Designing Condition for a Velocity of Inequality Rotatonal Equipment with Non-Circular Gears.)

  • 차철웅;최상훈
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1996년도 추계학술대회 논문집
    • /
    • pp.861-866
    • /
    • 1996
  • The Non-Circular Gears is more advantage than other machinery using link and cam in the automation equipment. We designed Non-Circular Gears for a velocity of inequalty rotational equipment according to the variation of pressure angle, radius of curvature etc., and studied about pitch curve.

  • PDF

반복사인격자에서 동시에 생기는 두 가지 무아레 무늬를 이용한 회전변위의 가시적 측정 (Visual Measurement of Rotational Displacements by Using Two Different Moire Fringes Simultaneously Generated by Repeated Sinusoidal Gratings)

  • 정연홍;오정효;조재흥
    • 한국광학회지
    • /
    • 제19권4호
    • /
    • pp.302-309
    • /
    • 2008
  • 컴퓨터 전산모의와 회전자를 이용한 실험을 통하여 회전변위에 따른 반복사인격자 한 쌍이 만드는 무아레 무늬의 변화를 세밀하게 조사하여 반복사인격자가 겹쳐서 동시에 생기는 두 가지의 서로 다른 무아레 무늬를 사용하는 작은 회전변위를 측정하는 가시적 방법을 보여준다. 이 무아레 무늬는12도 이상의 큰 각도 측정에 유용한 장주기의 넓고 긴 직선무늬와 12도 이하의 작은 각도 측정에 유리한 좁고 짧은 복잡한 직선무늬로 이루어져 있다. 그리고 무아레 무늬의 회전방향에 따라 회전변위의 회전방향도 동시에 가시적으로 판별할 수 있다.

Rotational State Distribution of NO after Collisions with Fast Hydrogen Atom

  • 김유항
    • Bulletin of the Korean Chemical Society
    • /
    • 제16권5호
    • /
    • pp.436-438
    • /
    • 1995
  • Based on the collisional time-correlation function approach a general analytical expression has been derived for the double differential cross-section with respect to the scattering angle and the final rotational energy, which can be applied to molecules with non-zero electronic orbital angular momentum after collision with fast hydrogen atoms. By integrating this expression another very simple expression, which gives the final rotational distribution as a function of the rotational quantum number, has also been derived. When this expression is applied to NO(2Π1/2, v'=1) and NO(2Π3/2, v'=1, 2, 3), it can reproduce the experimental rotational distribution after collision with fast H atom very well. The average rotational quantum number and average rotational energy using this expression are also in good agreement with those deduced from the experimental distributions.

하악운동 회전량과 과로의 형태에 관한 연구 (A Study on the Amount of Mandibular Rotation and Pattern of Condylar Path)

  • Kyung-Soo Han;You-Me Lee
    • Journal of Oral Medicine and Pain
    • /
    • 제21권2호
    • /
    • pp.369-382
    • /
    • 1996
  • The author performed this study to investige the relationship between condylar movements recorded with Pantronicⓡ and mandibular rotational torque movements with BioEGNⓡ. For this study 56 patients with Temporomandibular disorders(TMD) and 30 dental students without any masticatory signs and symptoms were selected as patients group and control group, respectively. The items recorded with Pantronicⓡ(Denar Corp., USA) were immediate side-shift, progressive side-shift, angle of orbiting path, protrusive path and PRI. BioEGNⓡ(Bioelectric gnathography, Bioresearch Inc., USA) were used to measure the amounts of mandibular rotational torque movements in frontal and horizontal plane, and the distance of mandibular translation at incisal area. Amount of mandibular rotational torque movement depicted between the condyles was automatically analysed by angle and difference in frontal and horizontal plane. The obtained data were processed with SAS program and the conclusion of this study were as follows : 1. Mean values of items between patients group and control group in Pantronic measurements were not significantly different except in left protrusive path and in Pantronic Reproducibility Index(PRI). There were no significant difference of condylar paths by preferred chewing side and affected side between the two groups. 2. The amount of mandibular rotational torque movements were differed in frontal angle and difference on protrusion, and in frontal and in horizontal difference on left excursion between the two groups. But the amounts of translatory movements were actually same on all eccentric movements. 3. The amount of mandibular rotational torque movements with splint mere almost not changed from those without splint, with the exception of in horizontal measurements on protrusion. 4. The correlations of items between in Pantronic measurements and in BioEGN measurements wert not consistently, significant, however, generally the ISS related significantly with horizontal torque movement positively, and with frontal torque movement negatively on the contrary, the PSS showed positive correlation with frontal torque movement, and negative correlation with horizontal torque movement.

  • PDF

저전압 대회전을 위한 분리된 압전 구동기에 의한 미소거울 (Micromirrors Driven by Detached Piezoelectric Microactuators For Low-voltage and Wide-angle Rotation)

  • 김성진;진영현;이원철;남효진;부종욱;조영호
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제55권3호
    • /
    • pp.149-155
    • /
    • 2006
  • This paper presents a torsional micromirror detached from PZT actuators (TMD), whose rotational motion is achieved by push bars in the PZT actuators detached from the micromirror. The push bar mechanism is intended to reduce the bending, tensile and torsional constraints generated by the conventional bending bar mechanism, where the torsional micromirror is attached to the PZT actuators (TMA). We have designed, fabricated and tested prototypes of TMDs for single-axis and dual-axis rotation, respectively. The single-axis TMD generates the static rotational angle of $6.1^{\circ}$ at 16 VDC, which is 6 times larger than that of single-axis TMA, $0.9^{\circ}$. However, the rotational response curve of TMD shows hysteresis due to the static friction between the cover and the push bar in the PZT actuator. We have shown that 63.2% of the hysteresis is due to the static friction caused by the initial contact force of the PZT actuaor. Without the initial contact force, the rotational response curve of TMD shows linear voltage-angle characteristics. The dual-axis TMD generates the static rotational angles of $5.5^{\circ}$ and $4.7^{\circ}$ in x-axis and y-axis, respectively at 16 VDC. The measured resonant frequencies of dual-axis TMD are $2.1\pm0.1$ kHz in x-axis and $1.7\pm0.1$ kHz in y-axis. The dual-axis TMD shows stable operation without severe wear for 21.6 million cycles driven by 16 Vp-p sinusoidal wave signal at room temperature.

비선형 점탄성 부싱모델의 회전방향모드에 대한 실험적 연구 (An Experimental Study of Nonlinear Viscoelastic Bushing Model for Torsional Mode)

  • 이성범;이성재;전성철;송동률;정재영;박찬석;이우현
    • Elastomers and Composites
    • /
    • 제43권1호
    • /
    • pp.25-30
    • /
    • 2008
  • 자동차 부싱은 차체로 전달되는 하중을 줄여주는 역할을 하는 자동차 현가장치의 주요 부품으로 바깥쪽 슬리브와 안쪽의 축 사이에서 가운데가 비어 있는 실린더의 형상을 가진다. 차축에 작용되는 힘과 모멘트에 대한 부싱의 상대변위 및 변형각도는 점탄성 성질을 나타내며, 부싱에서 힘과 모멘트와 이에 대한 변위와 변형각도의 관계는 다물체 동역학 시뮬레이션에 매우 중요하다. 본 연구는 자동차 부싱의 회전방향 모드에 대한 모멘트와 변형각도의 점탄성 관계를 변형각도에 의존하는 모멘트 완화함수를 통하여 부싱모델을 완성하였으며, 완성된 점탄성 부싱 모델은 회전방향 모드에 대한 실험값과 비교하여 검증하였다.

Experimental and analytical behavior of stiffened angle joints

  • Wang, Peng;Pan, Jianrong;Wang, Zhan;Chen, Shizhe
    • Steel and Composite Structures
    • /
    • 제26권1호
    • /
    • pp.67-78
    • /
    • 2018
  • The application of rib stiffeners is common on steel connections, with regard to the stiffened angle connection, experimental results about the influence of stiffeners under monotonic and cyclic loading are very limited. Consequently, this paper presents the experimental investigation on four types angle connections with or without stiffener under static loading and another four type stiffened angle connections subjected to cyclic loading. The static experimental result showed that the rib stiffener weld in tension zone of the connection greatly enhanced its initial rotational stiffness and flexural strength. While a stiffener was applied to the compression zone of the connection, it had not obvious influences on the initial rotational stiffness, but increased its flexural strength. The moment-rotation curves, skeleton curves, ductility, energy dissipation and rigidity were evaluated under cyclic loading. Stiffened top-and-seat angle connections behaved as semi-rigid and partial strength, and rotation of all stiffened angle connections exceeded 0.04rad. The failure modes between monotonic and cyclic loading test were completely different and indicated certain robustness.

직접 구동형 밸브 트레인 시스템의 태핏 회전에 관한 실험적 연구 (An Experimental Study on the Tappet Spin for a Direct Acting Valve Train System)

  • 조명래;김형준;문태선;한동철
    • 대한기계학회논문집A
    • /
    • 제27권7호
    • /
    • pp.1179-1184
    • /
    • 2003
  • The technique for measuring the rotational speed of tappet in direct acting type valve train system has been developed. The optic signal monitoring system with laser and optic fiber was designed to follow the signal of tappet rotation. The system was based on ON/OFF signal generation from the additional encoder teeth under the tappet with optic fibers attached photo transistor. The data showed that tappet rotation was affected by offset, oil temperature and cam shaft operating speed. Also it was found that tappet rotation increases with oil temperature. Tappet spin was delayed 10∼s20$^{\circ}$ cam angle after valve opening. The instantaneous rotational speed of tappet was reciprocal to cam shaft speed and the tappet and the cam angle ratio was located in the range of 0.1∼0.3.