• Title/Summary/Keyword: Results

Search Result 426,272, Processing Time 0.33 seconds

EFFECT OF CROSS-SECTIONAL AREA OF 6 NICKEL-TITANIUM ROTARY INSTRUMENTS ON THE FATIGUE FRACTURE UNDER CYCLIC FLEXURAL STRESS: A FRACTOGRAPHIC ANALYSIS (반복 굽힘 스트레스 하에서 전동식 니켈-티타늄 파일의 단면적의 크기가 피로파절에 미치는 영향 : 파절역학 분석)

  • Hwang, Soo-Youn;Oh, So-Ram;Lee, Yoon;Lim, Sang-Min;Kum, Kee-Yeon
    • Restorative Dentistry and Endodontics
    • /
    • v.34 no.5
    • /
    • pp.424-429
    • /
    • 2009
  • This study aimed to assess the influence of different cross-sectional area on the cyclic fatigue fracture of Ni-Ti rotary files using a fatigue tester incorporating cyclical axial movement. Six brands of Ni-Ti rotary files (ISO 30 size with. 04 taper) of 10 each were tested: Alpha system (KOMET), HeroShaper (MicroMega), K3 (SybronEndo), Mtwo (VDW), NRT (Mani), and ProFile (Dentsply). A fatigue-tester (Denbotix) was designed to allow cyclic tension and compressive stress on the tip of the instrument. Each file was mounted on a torque controlled motor (Aseptico) using a 1:20 reduction contra-angle and was rotated at 300 rpm with a continuous, 6 mm axial oscillating motion inside an artificial steel canal. The canal had a $60^{\circ}$ angle and a 5 mm radius of curvature. Instrument fracture was visually detected and the time until fracture was recorded by a digital stop watch. The data were analyzed statistically. Fractographic analysis of all fractured surfaces was performed to determine the fracture modes using a scanning electron microscope. Cross-sectional area at 3 mm from the tip of 3 unused Ni-Ti instruments for each group was calculated using Image-Pro Plus (Imagej 1.34n, NIH). Results showed that NRT and ProFile had significantly longer time to fracture compared to the other groups (p < .05). The cross-sectional area was not significantly associated with fatigue resistance. Fractographycally, all fractured surfaces demonstrated a combination of ductile and brittle fracture. In conclusion, there was no significant relationship between fatigue resistance and the cross-sectional area of Ni-Ti instruments under experimental conditions.

EFFECT OF FILM THICKNESS OF RESIN CEMENT ON BONDING EFFICIENCY IN INDIRECT COMPOSITE RESTORATION (레진 시멘트의 film thickness가 간접 복합 레진 수복물의 접착 효율에 미치는 영향에 관한 연구)

  • Lee, Sang-Hyuck;Choi, Gi-Woon;Choi, Kyung-Kyu
    • Restorative Dentistry and Endodontics
    • /
    • v.35 no.2
    • /
    • pp.69-79
    • /
    • 2010
  • The purpose of this study was to evaluate the effect of film thickness of various resin cements on bonding efficiency in indirect composite restoration by measurement of microtensile bond strength, polymerization shrinkage, flexural strength and modulus, fractographic FE-SEM analysis. Experimental groups were divided according to film thickness (< $50\;{\mu}m$-control, $50\;{\mu}m$-T50, $100\;{\mu}m$-T100, $150\;{\mu}m$-T150) using composite- based resin cements (Variolink II, Duo-Link) and adhesive-based resin cements (Panavia F, Rely X Unicem). The data was analyzed using ANOVA and Duncan's multiple comparison test (p < 0.05). The results were as follows ; 1. Variolink II showed higher microtensile bond strength than that of adhesive-based resin cements in all film thickness (p < 0.05) but Duo-Link did not show significant difference except control group (p > 0.05). 2. Microtensile bond strength of composite-based resin cements were decreased significantly according to increasing film thickness (p < 0.05) but adhesive-based resin cements did not show significant difference among film thickness (p > 0.05). 3. Panavia F showed significantly lower polymerization shrinkage than other resin cements (p < 0.05). 4. Composite-based resin cements showed significantly higher flexural strength and modulus than adhesive-based resin cements (p < 0.05). 5. FE-SEM examination showed uniform adhesive layer and well developed resin tags in composite-based resin cements but unclear adhesive layer and poorly developed resin tags in adhesive-based resin cements. In debonded surface examination, composite-based resin cements showed mixed failures but adhesive-based resin cements showed adhesive failures.

FRACTURE RESISTANCE OF CROWN-ROOT FRACTURED TEETH REPAIRED WITH DUAL-CURED COMPOSITE RESIN AND HORIZONTAL POSTS (수평 포스트와 이중중합 복합레진으로 수복된 치관-치근 복합파절 치아의 파절 저항성에 관한 연구)

  • Chang, Seok-Woo;Lee, Yong-Keun;Kyung, Seung-Hyun;Yoo, Hyun-Mi;Oh, Tae-Seok;Park, Dong-Sung
    • Restorative Dentistry and Endodontics
    • /
    • v.34 no.5
    • /
    • pp.383-389
    • /
    • 2009
  • The purpose of this study was to investigate the fracture resistance of crown-root fractured teeth repaired with dual-cured composite resin and horizontal posts. 48 extracted human premolars were assigned to control group and three experimental groups. Complete crown-root fractures were experimentally induced in all control and experimental teeth. In the control group. the teeth (n=12) were bonded with resin cement and endodontically treated. Thereafter, the access cavities were sealed with dual-cured composite resin. In composite resin core-post group (n=12), the teeth were endodontically treated and access cavities were sealed with dual-cured composite resin. In addition, the fractured segments in this group were fixed using horizontal posts. In composite resin core group (n=12), the teeth were endodontically treated and the access cavities were filled with dual-cured composite resin without horizontal posts. In bonded amalgam group (n = 12), the teeth were endodontically treated and the access cavities were sealed with bonded amalgam. Experimental complete crown-root fractures were induced again on repaired control and experimental teeth. The ratio of fracture resistance to original fracture resistance was analyzed with Kruskal-Wallis test. The results showed that teeth in control and composite resin core-post group showed significantly higher resistance to re-fracture than those in amalgam core group (p < 0.05). The resistance to refracture was high in the order of composite resin - post group, control group, composite resin group and bonded amalgam group. Within the scope of this study, the use of horizontal post could be beneficial in increasing the fracture resistance of previously fractured teeth.

THE BONDING DURABILITY OF RESIN CEMENTS (레진시멘트의 접착 내구성에 관한 연구)

  • Cho, Min-Woo;Park, Sang-Hyuk;Kim, Jong-Ryul;Choi, Kyoung-Kyu
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.4
    • /
    • pp.343-355
    • /
    • 2007
  • The objectives of this study was to evaluate the durability of 4 resin cements by means of microtensile bond strength test combined with thermocycling method and fractographic FE-SEM analysis. Experimental groups were prepared according to thermocycling (0, 1,000, 5,000) and the kind of resin cements, those were Variolink II, Multilink, Panavia F 2.0, Rely X Unicem. Flat dentin surfaces were created on mid-coronal dentin of extracted third molars. Then fresh dentin surface was grounded with 320-grit silicon carbide abrasive papers to create uniform smear layers. Indirect composite block (Tescera, Bisco Inc., Schaumburg, IL, USA) was fabricated ($12\;{\times}\;12\;{\times}\;6\;mm^3$). It's surface for bonding to tooth was grounded with silicon carbide abrasive papers from 180- to 600-grit serially, then sandblasted witk $20\;-\;50\;{\mu}m$ alumina oxide. According to each manufacturer's instruction, dentin surface was treated and indirect composite block was luted on it using each resin cement. For Rely X Unicem, dentin surface was not treated. The bonded tooth-resin block were stored in distilled water at $37^{\circ}C$ for 24 hours. After thermocycling, the bonded tooth-resin block was sectioned occluso-gingivally to 1.0 mm thick serial slabs using all Isomet slow-speed saw (Isomet, Buehler Ltd, Lake Bluff, IL, USA). These sectioned slabs were further sectioned to $1.0\;{\times}\;1.0\;mm^2$ composite-dentin beams. The specimens were tested with universal testing machine (EZ-Test, Shimadzu, Japan) at a crosshead speed of 1.0 mm/min with maximum load of 500 N. The data was analyzed using one-way ANOVA and Duncan's multiple comparison test at $p\;{\leq}\;0.05$ level. Within the limited results, we conclude as follows; 1. The bond strength of Variolink II was evaluated the highest among experimental groups and was significantly decreased after 1,000 thermocycling (p < 0.05). 2. The bond strength of Multilink was more affected by thermocycling than the other experimental groups and significantly decreased after 1,000 thermocycling (p < 0.05). 3. Panavia F 2.0 and Rely X Unicem showed the gradually decreased tendency of microtensile bond strength according to thermocycling but there was no significant difference (p > 0.05). 4. Adhesive based-resin cements showed lower bond strength with or without thermocycling than composite based-resin cements. 5. Variolink II & Multilink showed high bond strength and mixed failure, which was occurred with a thin layer of luting resin cement before thermocycling and gradually increased adhesive failure along the dentin surface after thermocycling. The bonding performance of resin cement can be affected by application procedure and chemical composition. Composite based-resin cement showed higher bond strength and durability than adhesive based-resin cement.

MICROLEAKAGE OF COMPOSITE RESIN RESTORATION ACCORDING TO THE NUMBER OF THERMOCYCLING (열순환 횟수에 따른 복합레진의 미세누출)

  • Kim, Chang-Youn;Shin, Dong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.4
    • /
    • pp.377-384
    • /
    • 2007
  • Present tooth bonding system can be categorized into total etching bonding system (TE) and self-etching boding system (SE) based on their way of smear layer treatment. The purposes of this study were to compare the effectiveness between these two systems and to evaluate the effect of number of themocycling on microleakage of class V composite resin restorations. Total forty class V cavities were prepared on the single-rooted bovine teeth and were randomly divided into four experimental groups: two kinds of bonding system and another two kinds of thermocycling groups. Half of the cavities were filed with Z250 following the use of TE system, Single Bond and another twenty cavities were filled with Metafil and AQ Bond, SE system. All composite restoratives were cured using light curing unit (XL2500, 3M ESPE, St. Paul, MN, USA) for 40 seconds with a light intensity of $600mW/cm^2$. Teeth were stored in distilled water for one day at room temperature and were finished and polished with Sof-Lex system. Half of teeth were thermocycled 500 times and the other half were thermocycled 5,000 times between $5^{\circ}C$ and $55^{\circ}C$ for 30 second at each temperature. Teeth were isolated with two layers of nail varnish except the restoration surface and 1 mm surrounding margins. Electrical conductivity (${\mu}A$) was recorded in distilled water by electrochemical method. Microleakage scores were compared and analyzed using two-way ANOVA at 95% level. From this study, following results were obtained: There was no interaction between variables of bonding system and number of thermocycling (p = 0.485). Microleakage was not affected by the number of thermocycling either (p = 0.814). However, Composite restoration of Metafil and AQ Bond, SE bond system showed less microleakage than composite restoration of Z250 and Single Bond, TE bond system (p = 0.005).

THE INFLUENCE OF CAVITY CONFIGURATION ON THE MICROTENSILE BOND STRENGTH BETWEEN COMPOSITE RESIN AND DENTIN (와동의 형태가 상아질과 복합레진 사이의 미세인장결합강도에 미치는 영향)

  • Kim, Ye-Mi;Park, Jeong-Won;Lee, Chan-Young;Song, Yoon-Jung;Seo, Deok-Kyu;Roh, Byoung-Duck
    • Restorative Dentistry and Endodontics
    • /
    • v.33 no.5
    • /
    • pp.472-480
    • /
    • 2008
  • This study was conducted to evaluate the influence of the C-factor on the bond strength of a 6th generation self-etching system by measuring the microtensile bond strength of four types of restorations classified by different C-factors with an identical depth of dentin. Eighty human molars were divided into four experimental groups, each of which had a C-factor of 0.25, 2, 3 or 4. Each group was then further divided into four subgroups based on the adhesive and composite resin used. The adhesives used for this study were AQ Bond Plus (Sun Medical, Japan) and XenoIII (DENTSPLY, Germany). And composite resins used were fantasists (Sun Medical, Japan) and Ceram-X mono (DENTSPLY, Germany). The results were then analyzed using one-way ANOVA, a Tukey's test, and a Pearson's correlation test and were as follows. 1. There was no significant difference among C-factor groups with the exception of groups of Xeno III and Ceram-X mono (p<0.05). 2. There was no significant difference between any of the adhesives and composite resins in groups with C-factor 0.25, 2 and 4. 3. There was no correlation between the change in C-factor and microtensile bond strength in the Fantasista groups. It was concluded that the C-factor of cavities does not have a significant effect on the microtensile bond strength of the restorations when cavities of the same depth of dentin are restored using composite resin in conjunction with the 6th generation self-etching system.

Selection of Cultivars with Vigorous Growth Habit for Street Tree, Dwarf Tree Form for Pot Plants, and Spreading Branches for Groundcovers in the Recently Developed Cultivars of Rose of Sharon (Hibiscus spp.) for Landscape Uses (나라꽃 무궁화 품종중 가로수용, 분화용 및 지피용으로 조경적 활용도가 높은 품종 선정)

  • Kang, Ho-Chul;Kim, Dong-Yeob;Ha, Yoo-Mi
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.34 no.2
    • /
    • pp.87-99
    • /
    • 2016
  • This study was carried out to characterize 127 recently developed cultivars of Rose of Sharon (Hibiscus spp.) in Korea and foreign Countries for landscape uses. The examined factors were growth characteristics such as tree height of a 1-year grafted plant(cm), plant type, growth habit, leaf characteristics such as shape and size, flower characteristics such as color, shape, size, and red eye during 2014 and 2015 for landscape uses. The results are obtained as follows; Hibiscus hybrid 'Daewangchun', 'Daeil', 'Lohengrin', 'Yeonam', 'Joomong', 'Jina', and H. syriacus 'Honggarosu' had vigorous shoot growth and tall tree size of 100cm. New Hibiscus cultivars, Hibiscus hybrid 'Daewangchun' and 'Daeil', having vigorous growth, uniform plant habit, upright, and compact branches were developed through interspecific crosses between H. syriacus 'Samchully' (♀) and H. sinosyriacus 'Seobong' (♂). This newly developed cultivar 'Daewangchun', 'Daeil', 'Lohengrin', 'Yeonam', 'Joomong', 'Jina', and H. syriacus 'Honggarosu' having tall vigorous growth d unique flower with long red eye can be used as street tree or specimen plant in landscape. Otherwise, H. syriacus 'Tamla', 'Melrose', 'Bidan', 'Hi Lea', 'Byeollee', 'Byunghwa', 'Mibak', 'Hanyang', 'Chungam', 'Lil Kim Violet', 'Jongmoo', 'Eunhasu', Hibiscus hybrid 'Saehanseo', and Hibiscus hybrid 'Yousoon' were selected as small tree of 30~39cm. They had dwarf form in tree seemed to be suitable for pot or flower bed planting on both indoor and outdoor conditions. H. syriacus 'Antong', 'Chungjo', and 'Lil Kim' were less than 30 cm of tree size. H. syriacus 'Antong', 'Chungjo', and 'Lil Kim', characterized by its compact, upright and outwardly spreading plant habit; freely branching habit; dark green-colored leaves; good garden performance. Therefore, the new cultivars with tall and small tree size were a promising cultivar as a ground covers or pot planting as woody landscape plant.

Typological Characteristics of Waterscape Elements from the Chapter 「Sancheon」 of the Volumes Gyeongsang-province in 『Sinjeung Donggukyeojiseungram』 (『신증동국여지승람』의 경상도편 「산천(山川)」 항목에 수록된 수경(水景) 요소의 특징)

  • Lim, Eui-Je;So, Hyun-Su
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.34 no.2
    • /
    • pp.1-15
    • /
    • 2016
  • This study aims at the consideration of the usages of traditional waterscape elements, which are difficult to define their concepts and their differences and it has been proceeded mainly with analysis of literature. It elicited various waterscape types by extracting the place names associated with the watersacpe elements from the chapter "Sancheon" of the volumes Gyeongsang-province in "Sinjeung Donggukyeojiseungram", which is a government-compiled geography book in the early period of Joseon Dynasty, and drew the features of each waterscape element by interpreting the dictionary definition and the original text and studying the similar examples. The results of study are drawn as follows. 1. The chapter "Sancheon" includes 22 types of waterscape elements and they are classified by means of locations and water-flow forms: River Landscape, Lake & Pond Landscape, Coast landscape. 2. River landscape maintaining constant natural water-flow constitutes the linear type, related to the class of stream, which includes 'Su(water)', 'Gang(river)', 'Cheon(stream)' and 'Gye(brook)' and the dotty type, created by the nature of trenched meander rivers, which includes 'Tan(beach)', 'Roe(rapids)', 'Pok(waterfall)' and 'Jeo(sandbank)'. 3. Lake & Pond Landscape forming water collected in a certain area constitutes 'Ho(lake)', which is a broad and calm spot created around mid and down stream of river, 'Yeon(pool)', 'Dam(pond)', 'Chu(small pond)', which are naturally created on the water path around mid and down stream of river, 'Ji(pond)', 'Dang(pond)', 'Taek(swamp)', which is collected on a flatland and 'Cheon(spring)', 'Jeong(spring)' which means gushing out naturally. 4. Coast Landscape includes 'Ryang', 'Hang', which are the space between land and an island or islands, 'Got(headland)' which sticks out from the coast into the sea, 'Jeong(sandbank)' which forms sandy beaches and 'Do' which shows high appearance frequency by reflecting the geographical importance of islands. This study comprehended the diversity of traditional waterscape elements and drew the fact that they are the concept reflecting the differentiated locational, scenic and functional features. That way, it understood the aesthetic sense on nature, which ancestors had formed with the interests in natural landscape and the keen observation on it, became the basic idea elucidating the characteristic on Korean traditional gardens, which minimize the artificiality and make nature the subject.

A Study on Growth Condition and Management of Protected Trees in Kimpo (김포시 보호수의 생육실태와 관리방안 연구)

  • Doo, Chul-Eon;Lee, Jong-Bum;Lee, Jae-Keun
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.30 no.1
    • /
    • pp.125-134
    • /
    • 2012
  • This study is determined by tree vigor of analyzing of each object's growth condition in Locational Characteristics and compare the result with impediment extent rate in crown area to provide the management Study about the influence of man-made structures in numbers of protected trees. 68 places where are in the list of Kimpo protected trees were researched in Natural environments, vital degree of trees, number of trees. Crown area was calculated surveying it around the directions of North, East, South and West branching out. Impediment in the area was analyzed after classified into artificial impediment like paved surface(ascon, concrete, block, etc.), a building and a breast wall and natural impediment like soil, stonework and gravel and conclusions are as follow. In analyzing of natural environments, he ground where protected trees have located is consist of 72.05 of manmade structure and artificial in all. There are many protected trees which have less space than crown area for growth suggested by Woo-kyung Sim and Se-kyun Shin in 1992. And it was analyzed that making growth space for protected trees and management of impediment are urgently needed because of that the proportion of impediment covering the crown area has increased as cities are becoming more urbanized results in transforming of trees and weakness of tree vigor. This research shows that under 20% of in crown area is tree vigor determination 1-2 grade 21-50% under is 2-3 grade, higher than 50% is 3-5 grade. More impediment have more difficulty for growing, with the management of root system of protected trees need to be under 20% of rate of land is necessary was improved. As follows are suggested about the standard of management in artificial impediment which influence the number of trees. Firstly, impediment in crown area must be restricted under 20%, but in case outside of the area is not artificial the rate could be higher considerable. Secondly, protected trees growth space secured as much as crown area and impediment must be installed outside the crown area. Thirdly, to move the protected trees, condition of growth space secure must be considered. Fourthly, to develope land, the area around protected trees should be utilized in a park, the area of impediment installation in crown area should be limited as well. Fifthly, As many shown in previous research, for the improvement of old big trees and protected trees, need the tax favor of landowner and purchase of around land, to manage, it needs the budget of local government and advice of expert. Also the study on how various kind of impediment nearby protected trees influence on them has to be continued.

Basic Studies on the Location and Spatial Organization Characteristics of the Seoul Sajikdan (서울 사직단(社稷壇)의 입지(立地)와 공간구성특성(空間構成特性)에 관한 기초연구(基礎硏究))

  • Choi, Seung-Sik;Shim, Woo-Kyung;Yoo, Jong-Ho;Jeon, Hye-Won;Choi, Jong-Hee
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.30 no.1
    • /
    • pp.146-158
    • /
    • 2012
  • This study aims to discussion the characteristics of location and spatial organization of the Seoul Sajikdan that has significance as one of national ceremonial place in Joseon Dynasty to understand its landscape architectural characteristics. To do this, we studied in two ways; review of historical documents and analysis of the present conditions and photographing, research materials about the form of physical structure. Through these ways, the results are as follows. First, in case of construction, Sajikdan took fundamental shape in Tae-jong 16 year(1416), since then it had been changed during Imjin War, reign of Suk-jong, and Japanese Colonial Era. It took present shape through restoration of Seoul Sajikdan in 1998. Second, in case of location, Sajikdan abuts onto southeastern range of Mt. Inwang that is Wubaekho(右白虎) of inner four mountain(內四山) of Hanyang, and it has a topography of west-high-east-low type. Also its territory is up to Maedong elementary school, the office of Sajik-dong, and a Dangun shrine. Third, in case of spatial organization, Sadan and Jikdan are in harmony of Yin-Yang(陰陽) and arranged in the center. As making Yumun and Sinmun(神門) at the center of four side of Yuwon and Juwon(周垣), they show organization of the Five Elements. And subsidiary buildings are thought that its arrangement was considered functional similarity and use convenience. Finally, in case of spatial component, Danyu structures are Sadan and Jikdan that hold a Sajikdaeje(社稷大祭), Yuwon that surround two altars, and Juwon that is outer fence of Yuwon. Architectures are Sajikdan Jeongmun, Sinsil, and Anhyangcheong. Also Prunus yedoensis, Zelkova serrata, Acer palmatum, are planted, but Pinus densiflora was main species and there needs to be replanted suitably to the site.