• Title/Summary/Keyword: Resonance Type

Search Result 1,085, Processing Time 0.026 seconds

Accessory Belly of the Piriformis Muscle as a Cause of Piriformis Syndrome: a Case Report with Magnetic Resonance Imaging and Magnetic Resonance Neurography Imaging Findings

  • Kim, Hae-Jung;Lee, So-Yeon;Park, Hee-Jin;Kim, Kun-Woo;Lee, Young-Tak
    • Investigative Magnetic Resonance Imaging
    • /
    • v.23 no.2
    • /
    • pp.142-147
    • /
    • 2019
  • Piriformis syndrome caused by an accessory belly of the piriformis muscle is very rare. Only a few cases have been reported. Here, we report a case of piriformis syndrome resulting from an extremely rare type of accessory belly of the piriformis muscle originated at the proximal third portion of the main piriformis muscle and attached separately to the greater trochanter inferior to the insertion of the main piriformis muscle. A definitive diagnosis of piriformis syndrome was made based on magnetic resonance imaging and magnetic resonance neurography findings that were consistent with results of nerve conduction study and needle electromyography.

Finite Element Analysis of Step-down Piezoelectric Transformer with Various Shape (형태의 변화에 따른 강압용 압전변압기의 유한요소해석)

  • Chong, Hyon-Ho;Park, Tae-Gone;Kwon, Oh-Young
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07b
    • /
    • pp.697-700
    • /
    • 2003
  • This paper presents design and analysis of step-down piezoelectric transformer for application to AC-adapters. These transformers are consist of rectangular type and disk type multilayered piezoelectric ceramic plate. This piezoelectric transformer operated in third thickness resonance vibration mode. Finite element methode(FEM) was used for analysing transformer. Vibration mode and electric field of piezoelectric transformer were simulated at resonance frequency. As results, rectangular type transformer's output voltage was higher than the disk type. But disk type transformer's current was lagger than rectangular type. These results are assumed that disk type transformer's mixed vibration mode influence transformer's output characteristics. From these results, we expect that disk type piezoelectric transformer is more adoptable than rectangular plate type piezoelectric transformer for AC adapters.

  • PDF

Study on Performances of the Lever Type Anti-resonance Vibration Isolator (레버형 반공진 진동 절연기의 진동 특성 연구)

  • Yun, Jong-Hwan;Kim, Gi-Woo;Lee, Hyeongill
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.26 no.2
    • /
    • pp.187-194
    • /
    • 2016
  • Parametric study on the lever type dynamic anti-resonance vibration isolator (DAVI) is executed to introduce the system in the path of vibration transmission for the vibratory response attenuation. The effects of inertia and location of the lever on the system performances are investigated using FEA. The effects of other parameters such as ratio of lever lengths, ratio of masses and the location of pivot are studied with analytical approach. According to the results, all the parameters except lever location affect the system response in their own ways. Consequently, the optimal lever type DAVI for translational or rotational system can be efficiently designed by selecting system parameters using the procedure introduced in this study.

Design of the Protection circuit for Electric ballast with $LC_SC_P$ resonance type Half-bridge Inverter ($LC_SC_P$ 공진 타입의 하프 브리지 인버터 구조를 가지는 전자식 안정기 보호회로 설계)

  • Choe, Hyeon-Hui;Park, Chong-Yun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.8
    • /
    • pp.1538-1543
    • /
    • 2009
  • The electric ballast for ceramic metal halide lamp needs a protection circuit to prevent from over voltage and over current in the case that the lamp or the electric ballast are in faults. In this paper, cost-effective and high performance protection circuit is proposed for the electric ballast. The proposed protection circuit is adapted to the electric ballast with $LC_SC_P$ resonance type half bridge inverter. The experimental results demonstrate that the proposed circuit can protect effectively under open and short fault conditions.

Non-submerged type implant stability analysis during initial healing period by resonance frequency analysis (Resonance frequency analysis를 이용한 non-submerged type 임플란트의 초기 안정성 분석)

  • Kim, Deug-Han;Pang, Eun-Kyoung;Kim, Chang-Sung;Choi, Seong-Ho;Cho, Kyoo-Sung
    • Journal of Periodontal and Implant Science
    • /
    • v.39 no.3
    • /
    • pp.339-348
    • /
    • 2009
  • Purpose: The purpose of the present study was to analyze the implant stability quotient(ISQ) values for Korean non-submerged type implant and determine the factors that affect implant stability. Methods: A total of 49 Korean non-submerged type implants were installed in 24 patients, and their stability was measured by resonance frequency analysis(RFA) at the time of surgery, and 1, 2, 3, 4, 8, 12 weeks postoperatively. The data for implant site, age, sex, implant length and diameter, graft performing, bone type, and insertion torque were analyzed. Results: The lowest mean stability measurement was at 3 weeks. There was significant difference between implant placement and 12 weeks. There was significant difference between implant placement and 12 weeks in diameters of 4.1 mm and 4.8 mm. Also, there were significant differences between diameters of 4.1 mm and 4.8 mm at implant placement and 12 weeks after surgery. This result suggests that the factor related to implant diameter may affect the level of implant stability. No statistically significant relationship was found between the resonance frequency analysis and the variables of maxilla/mandible, sex, anterior/posterior, implant length, age of patient, graft performing, bone type, insertion torque during initial healing period. Conclusions: These findings suggest that the factor related to implant diameter may affect the variance of implant stability, and ISQ value of implant was stable enough for proved stability level during initial healing period.

Preoperative Gadolinium-enhanced Magnetic Resonance Images on Infectious Spondylitis

  • Kim, Seok-Won;Lee, Seung-Myoung;Shin, Ho
    • Journal of Korean Neurosurgical Society
    • /
    • v.38 no.5
    • /
    • pp.355-358
    • /
    • 2005
  • Objective : The purpose of this study is to analyze the patterns of intervertebral disc enhancement seen in infectious spondylitis, differentiate between two groups[tuberculous vs pyogenic spondylitis]. Methods : Between January 1994 and December 2002, 83patients underwent operative procedure with confirmed to histopathologic evaluation. Magnetic resonance[MR] images were obtained in all patients and were analyzed retrospectively. 57patients had tuberculosis and 26patients were infected by pyogens. The patterns of gadolinium enhancement of disc were classified into 4 types[post's classification] : Type I, non-enhancing; Type II, enhancement of the peripheral rim; Type III, Type II with central area and partial endplate; Type IV, general enhancement. Results : The enhancement patterns observed were as follows : Common pattern of tuberculous spondylitis was Type II, and pyogenic spondylitis was Type III. [p < 0.01] This difference may result from pathophysiologic varieties of organisms. Conclusion : Careful preoperative MR analysis of the patterns of disc enhancement occuring in infectious spondylitis can be useful for differentiating between the tuberculous and pyogenic spondylitis.

Backbone NMR assignments of the anti-CRISPR AcrIIA5 from phages infecting Streptococcus thermophilus

  • An, So Young;Kim, Eun-Hee;Bae, Euiyoung;Suh, Jeong-Yong
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.24 no.3
    • /
    • pp.70-76
    • /
    • 2020
  • The CRISPR-Cas system provides an adaptive immunity for bacteria and archaea against invading phages or foreign plasmids. In the type II CRISPR-Cas system, a single effector protein Cas9 and a guide RNA form an RNA-guided endonuclease complex that can degrade DNA targets of foreign origin. To avoid the Cas9-mediated destruction, phages evolved anti-CRISPR (Acr) proteins that neutralize the host bacterial immunity by inactivating the CRISPR-Cas system. Here we report the backbone 1H, 15N, and 13C resonance assignments of AcrIIA5 that inhibits the endonuclease activity of type II-A Streptococcus thermophilus Cas9 and also Streptococcus pyogenesis Cas9 using triple resonance nuclear magnetic resonance spectroscopy. The backbone chemical shifts of AcrIIA5 predict a disordered region at the N-terminus, followed by an αββββαβββ fold.

The Electronic Ballast Design of Acoustic Resonance Free and Transient Over Current Limit for High Power MHL (음향 공명 제거 및 과도 상태 전류를 제한시킨 고출력 메탈 헬라이드 램프용 전자식 안정기 설계)

  • Kim, Ki-Nam;Park, Jong-Yun;Choi, Young-Min
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.5
    • /
    • pp.904-911
    • /
    • 2010
  • This paper presents the design of acoustic resonance free and over current limit during transient state consideration electronic ballast for 1.5kW Metal-Halide Lamp(MHL) that employs frequency modulation (FM) technique. The proposed ballast consists of a Full-Bridge(FB) rectifier, a passive power factor correction (PFC) circuit, a full-bridge inverter, an ignitor using LC resonance and a control circuit for frequency modulation. The frequency modulation technique is the most effective solution to eliminate acoustic resonance among other technique. It spreads power spectrum of lamp to reduce the supplied power spectrum under the energy level of eigen-value frequency. Moreover, the proposed ballast is simple and cost effective above conventional ballast. A new PFC circuit is proposed which combines with LCD type and PCSR filter. A new PFC circuit has higher PF and lower THD than conventional LCD type and secure high reliability. Finally, to protected switching components in transient state, the surge current into ballast is limited by increase the switching frequency. Performance of the proposed ballast was validated through computer simulation using Pspice, experimentation and by applying it to an electronic ballast for a prototype 1.5kW MHL.

Characteristics of Wireless Power Transmission applying the superconducting coil (초전도 코일을 적용한 WPT 특성)

  • Jeong, In-Sung;Choi, Hyo-Sang
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.6
    • /
    • pp.762-766
    • /
    • 2013
  • Interest in Wireless Power Transmission (WPT) technology has been increasing worldwide recently. This trend is proved by commercialized products such as electric toothbrush, wireless razor, and wireless charger for mobile phone battery. Studies for enhancing the applicability of the technology have been continuously conducted. Currently the WPT technology is based on the technologies using microwave, inductively coupling, and magnetic resonance. In the meantime, development of the microwave-based WPT faces difficulty due to health hazards involved in the technology, and application of the WPT technology using inductively coupling is restricted by area due to the problem of transmission length. In comparison, the WPT technology using magnetic resonance draws attention in terms of efficiency and transmission length. In this study, the sending coil based on the WPT technology using magnetic resonance system was replaced with an HTS coil to enhance transmission efficiency. Since the HTS coil has a zero resistance, power transmission loss can be minimized. At the same time, size of the current density could be increased to 100 times or more than typical coils. In addition, through impedance matching of LC device, maximal resonance properties were induced and consequently, frequency selection quality characteristics or Q was enhanced. As a result, the WPT type using the HTS coil showed a longer transmission length and better transmission efficiency compared with the WPT type using typical coils.