• 제목/요약/키워드: Resin matrix

검색결과 457건 처리시간 0.028초

Accurate Measurement of Isotope Amount Ratios of Lead in Bronze with Multicollector Inductively Coupled Plasma Mass Spectrometry

  • Lee, Kyoung-Seok;Kim, Jin-Il;Yim, Yong-Hyeon;Hwang, Euijin;Kim, Tae Kyu
    • Mass Spectrometry Letters
    • /
    • 제4권4호
    • /
    • pp.87-90
    • /
    • 2013
  • Isotope amount ratios of lead in a bronze sample have been successfully determined using multicollector inductively coupled plasma mass spectrometry (MC-ICP-MS). Matrix separation conditions were tested and optimized using ion exchange chromatography with anion-exchange resin, AG1-X8, and sequential elution of the 0.5 M HBr and 7 M $HNO_3$ to separate lead from very high contents of copper and tin in bronze matrix. Mercury was also removed efficiently in the optimized separation condition. The instrumental isotope fractionation of lead in the MC-ICP-MS measurement was corrected by the external standard sample bracketing method using an external standard, NIST SRM 981 lead common isotope ratio standard followed by correction of procedure blank to obtain reliable isotope ratios of lead. The isotope ratios, $^{206}Pb/^{204}Pb$, $^{207}Pb/^{204}Pb$, $^{208}Pb/^{204}Pb$, and $^{208}Pb/^{206}Pb$, of lead were determined as $18.0802{\pm}0.0114$, $15.5799{\pm}0.0099$, $38.0853{\pm}0.0241$, and $2.1065{\pm}0.0004$, respectively, and the determined isotope ratios showed good agreement with the reference values of an international comparison for the same sample within the stated uncertainties

산화억제제 첨가에 의한 탄소/탄소 복합재료의 물성에 관한 연구: 9. 복합재료의 충격특성에 관한 연구 (Influence of Oxidation Inhibitor on Carbon-Carbon Composites: 9. Studies on Impact Properties of the Composites)

  • 박수진;서민강;이재락
    • Composites Research
    • /
    • 제16권3호
    • /
    • pp.41-48
    • /
    • 2003
  • 본 연구에서는 고온 산화분위기 하에서 탄소/탄소 복합재료의 내산화 특성 향상을 위해 사용된 이규화 몰리브덴(MoSi$_2$)의 함량(0. 4, 12. 그리고 20 wt%)에 따른 복합재료의 충격특성에 관하여 고찰하였다. 결과로서, MoSi$_2$가 함침된 탄소/탄소 복합재료는 이를 함유하지 않은 것에 비하여 충격특성 향상의 원인이 되는 탄소섬유와 매트릭스 수지간의 계면결합력 증가를 가져왔으며, 특히 12 wt% MoSi$_2$가 현재의 시스템에서 가장 우수한 충격특성을 나타내었다. 이는 복합재료 내의 탄소섬유, 필러, 그리고 매트릭스 수지간의 계면 접착력의 증가를 가져오는 90$0^{\circ}C$ 전후에서 MoSi$_2$의 취성­연성 전이(BDT) 작용 때문이라 사료된다.

Mechanical properties related to the microstructure of seven different fiber reinforced composite posts

  • de la Pena, V?ctor Alonso;Darriba, Iria L;Valea, Martin Caserio;Rivera, Francisco Guitian
    • The Journal of Advanced Prosthodontics
    • /
    • 제8권6호
    • /
    • pp.433-438
    • /
    • 2016
  • PURPOSE. The aim of this in vitro study was to evaluate the mechanical properties (bending strength and hardness) of seven different fiber reinforced composite posts, in relation to their microstructural characteristics. MATERIALS AND METHODS. Two hundred eighty posts were divided into seven groups of 40, one group for each type of post analyzed. Within each group, 15 posts were subjected to three-point bending strength test, 15 to a microhardess meter for the Knoop hardness, and 10 to Scanning Electron Microscope in order to determine the diameter of the fibers and the percentage of fibers embedded in the matrix. To compare the flexural strength in relation to the type of fiber, matrix, and the hardness of the posts, a Kruskal-Wallis H test was used. The Jonckheere-Terpstra test was used to determine if the volume percent of fibers in the post influenced the bending strength. RESULTS. The flexural strength and the hardness depended on the type of fibers that formed the post. The lower flexural strength of a post could be due to deficient bonding between the fiber and the resin matrix. CONCLUSION. According to the results, other factors, besides the microstructural characteristics, may also influence the mechanical properties of the post. The feature that has more influence on the mechanical properties of the posts is the type of fiber.

탄소섬유 강화 에폭시 수지 복합재료의 열안정성 및 기계적 계면특성에 미치는 SiC 표면처리 영향 (Effect of Surface Treated SiC on Thermal Stability and Mechanical Interfacial Properties of Carbon Fiber/Epoxy Resin Composites)

  • 박수진;오진석;이재락;이경엽
    • Composites Research
    • /
    • 제16권3호
    • /
    • pp.25-31
    • /
    • 2003
  • 본 연구에서는 화학적 표면처리에 따른 탄화규소(SiC)의 표면특성 변화가 탄소섬유강화 에폭시 복합재료의 열안정성 및 기계적 계면물성에 미치는 영향을 조사하였다. 표면처리된 탄화규소의 표면특성은 산ㆍ염기도와 접촉각 측정을 통하여 알아보았으며, 열안정성은 TGA를 이용하여 조사하였다. 제조한 복합재료의 기계적 계면물성은 ILSS와 임계세기인자($\textrm{K}_{IC}$), 그리고 critical strain energy release rate($\textrm{G}_{IC}$)를 통하여 고찰하였다. 실험 결과 산 처리된 SiC(A-SiC)는 미처리된 SiC(V-SiC)나 염기처리된 SiC(B-SiC)에 비하여 산도가 증가하였다. 접촉각 측정 결과, 화학적 표면처리는 극성요소의 증가에 기인하는 SiC의 표면자유에너지를 증가시켰다. 이와 같은 물성들은 양극산화로 향상되어졌는데, 이는 좋은 젖음성이 최종 복합재료의 섬유와 매트릭스 사이의 계면결합력을 증가시키는데 중요한 역할을 하기 때문인 것으로 사료된다.

금속-PDC 착물의 음이온교환 수지 상 흡착에 의한 흔적량 코발트와 니켈의 동시 예비농축 및 정량 (Preconcentration and Determination of Trace Cobalt and Nickel by the Adsorption of Metal-PDC Complexes on the Anion-Exchange Resin Suspension)

  • 한철우;인교;최종문;김선태;김영상
    • 분석과학
    • /
    • 제13권5호
    • /
    • pp.608-615
    • /
    • 2000
  • 물 시료에 존재하는 극 미량의 니켈과 코발트를 착물로 형성시켜 이온 교환수지 서스펜션에 흡착시켜 분리 농축하여 정량하는 방법을 연구하였다. 리간드로 APDC (ammonium pyrrolidine dithiocarbamnate)를 사용하여 극 미량 이온들을 착물로 형성시켜 농축한 다음, 전열 원자흡수 분광광도법으로 정량하였다. 이때 착물 형성을 위한 수용액의 pH와 착화제인 APDC의 양, 흡착을 위한 이온교환 수지의 종류 및 저어주는 시간, 역 분산에 사용하는 산의 종류 및 농도, 초음파 진동시간 등의 실험조건들을 최적화 하였다. 시료용액의 pH를 5로 조절하고 APDC의 양을 몰 비로 분석원소 전체의 430배 이상 첨가하여 코발트와 니켈을 정량적으로 착물을 형성시켰다. 이온교환 수지는 음이온 형태의 Dowex 2-X8이 우수하였다. pH를 조절한 시료용액, 리간드 및 수지 서스펜션을 혼합하고 1분간 저어주어 흡착을 완전하게 하였다. 역 분산을 위해서는 0.1 M 염산이 가장 좋았고, 이때 막 필터로 거른 교환 수지를 초음파 진동기에서 7분간 진동하면 충분하였다. 팔라듐을 염산과 함께 사용하면 매트릭스를 개선하여 재현성과 감도가 개선되었다. 바탕흡수 신호표준편차의 세배에 해당하는 검출한계는 Co 0.36 ng/mL, Ni 0.27 ng/mL로 극미량 검출이 가능하였고 시료에 일정량 첨가한 분석원소의 회수율은 각각 99-102%와 100-105% 이었다.

  • PDF

광중합형 수복용 복합레진의 기계적 성질에 미치는 수중침적과 Thermal Cycling의 영향 (Effect of Immersion in Water and Thermal Cycling on the Mechanical Properties of Light-cured Composite Resins)

  • 배태성;김태조;김효성
    • 대한의용생체공학회:의공학회지
    • /
    • 제17권3호
    • /
    • pp.327-336
    • /
    • 1996
  • This study was performed to investigate the effec% of immersion in water and thermal cycling on the mechanical peoperties of light cured restorative composite resins. Five commerically available light-cured composite resins(Photo Clearfil A : CA, Lite-Fil A . LF, Clearril Photo Posterior CP, Prisms AP.H.. PA, 2100 : ZH) were unto The specimens of 12 m in diameter and 0.7 m in thickness were made, and an immersion in $37^{\circ}C$ water for 7 days and a thermal cycling of 1000 cycles at 15 second dwell time each in $5^{\circ}C$ and $55^{\circ}C$ baths were performed. Biaxial flexure test was conducted using the ball-on-three-ball method at the crosshead speed of 0.5mm/min. In order to investigate the deterioration of composite resins during the thermal cycling test, Weibull analysis for the biaxial flexure strengths was done. Fracture surfaces and the surfaces before and after the thermal cycling test were examined by SEM. The highest Weibull modulus value of 10.09 after thermal cycling tests which means the lowest strength variation, was observed in the CP group, and the lowest value of 4.47 was obsered in the LF Group. Biaxial flexure strengths and Knoop hardness numbers significantly decreased due to the thermal cycling ($\textit{p}$< 0.01), however, they recovered when specimens were drie4 The highest biaxial flexure strength of 125.65MPa was observed in the ZH group after the thermal cycling test, and the lowest value of 64.86MPa was observed in the CA group. Biaxial flexure strengths of ZH and CP groups were higher than those of PA, CF, and CA groups after thermal cycling test($\textit{p}$< 0.05). Knoop hardness numbers of CP group after the thermal cycling test was the highest(95.47 $\pm$ 7.35kg/$mm^2$) among the samples, while that of CA group was the lowest(30.73 $\pm$ 2.58kg/$mm^2$). Knoop hardness numbers showed the significant differences between the CP group and others after the thermal cycling test(($\textit{p}$< 0.05). Fracture surfaces showed that the composite resin failure developed along the matrix resin and the filler/resin interface region, and the cracks propagated in the conical shape from the maximum tensile stress zone.

  • PDF

Bulk fill 유동성 복합레진의 변연 누출에서 다른 중합시간의 영향에 대해 마이크로시티를 이용한 평가 (Evaluation of marginal leakage of bulk fill flowable composite resin filling with different curing time using micro-computed tomography technology)

  • 김은지;이규복;진명욱
    • 구강회복응용과학지
    • /
    • 제32권3호
    • /
    • pp.184-193
    • /
    • 2016
  • 목적: 중합 시간이 bulk fill 유동성 복합레진의 미세누출에 미치는 영향을 마이크로시티를 이용하여 평가하고자 하였다. 연구 재료 및 방법: 30개의 발거된 인간 대구치에 변형된 2급 와동인 vertical slot cavity를 형성하였다. SonicFill과 SureFil SDR flow을 단일 충전하였으며, 다른 중합시간(20, 40, 60초)으로 광중합 하였다. 모든 표본은 5000번의 thermal cycle을 시행하였다. 치아는 silver nitrate 용액에 24시간 동안 침전 후 8시간 동안 현상액에 침전하였다. 마이크로시티를 사용하여 시편을 촬영 후 침투된 silver nitrate solution을 3차원적으로 재건하여 그 부피를 측정하였다. 변연 누출 결과값의 통계 처리는 Mann-Whitney test를 사용하였다. 결과: 광중합 시간의 증가는 두 bulk fill 유동성 복합레진에서 변연 누출을 증가시켰다. 두 복합레진 사이 유의한 차이는 없었다. 결론: 중합 시간은 bulk fill 유동성 복합레진의 변연 누출을 증가시킬 수 있는 요인이었다. 또한 마이크로시티를 통해 레진-치아 계면에서 변연 누출의 양을 비파괴적 방법으로 3차원적으로 재건하여 측정할 수 있었다.

CFRP Chip 표면처리에 따른 페놀복합재료의 강화, 내열성 및 난연성 향상 (Reinforcement, Thermal and Fire Retardant Improvement of Phenolic Composites by Surface Treatment of CFRP Chip)

  • 권동준;왕작가;구가영;박종만
    • 접착 및 계면
    • /
    • 제13권2호
    • /
    • pp.58-63
    • /
    • 2012
  • 탄소섬유강화플라스틱(CFRP)의 홀 가공 시 chip이 발생된다. 이때 발생되는 chip은 단순 폐기용 차원이 아닌 미세탄소섬유와 에폭시의 조성으로 이루어져 있다. Chip을 강화재로 활용하기 위해서는 탄소섬유만의 조성을 이루어야 고분자 기지와 계면접착력이 증가될 수 있다. Chip 내 탄소섬유의 길이를 일정하게 하기 위해 막자 사발을 이용한 절단 과정 후 $H_2O_2$를 이용한 표면처리를 하여 탄소섬유에 붙어있는 에폭시를 제거하였다. Chip을 이용하여 페놀수지를 기지로 한 페놀복합재료를 제조하였으며, 내열성 및 난연성 재료로 활용 가능성을 평가하였다. 기존의 페놀보다 표면처리를 한 chip복합재료가 기계적, 열적 물성이 향상됨을 확인하였으며, 젖음성 평가를 이용하여 표면물성에 따른 재료의 물성을 평가하였다. 불균질한 표면 조성에 의해 표면 거칠기가 달라지기 때문에 페놀복합재료의 접촉각이 증가되었다. 난연성 평가는 ASTM D635-06 방법으로 수행하였다. 평가결과, chip의 첨가 및 표면처리의 영향에 의해 난연성이 향상되었다.

Long-term AC Electrical Treeing Behaviors of Epoxy/Layered Silicate Nanocomposites Prepared by a 3-Roll Mill

  • Park, Jae-Jun
    • Transactions on Electrical and Electronic Materials
    • /
    • 제13권2호
    • /
    • pp.85-88
    • /
    • 2012
  • Studies on the effects of layered silicate content on the AC electrical treeing and breakdown behaviors of epoxy/layered silicate nanocomposites were carried out in needle-plate electrode geometry. Wide-angle X-ray diffraction (WAXD) analysis and transmission electron microscopy (TEM) observation showed that 1 wt% of the multilayered silicate was fully exfoliated into nano-sized monolayers in the epoxy matrix however, over 3 wt% of the silicate was in an intercalated state. When 1 wt% layered silicates were incorporated, an electrical tree was initiated in 439 min and propagated at a speed of 2.3 ${\mu}m$/min after applying 781.4 kV/mm, representing a decreased in starting initiation time by a factor of 11.0 and increase in propagation speed by a factor 8.2 in comparison with neat epoxy resin. These values were in great decline after the layered silicate content was increased to 3wt% which implies that the exfoliated silicate blocked the tree initiation and propagation processes effectively. However the effect was largely decreased in the intercalated state.

PWB 기판용 Embedded Capacitor필름 제작에 관한 연구 (Study on the Fabrication of Embedded Capacitor Films for PWB substrate)

  • 이주연;조성동;백경욱
    • 한국마이크로전자및패키징학회:학술대회논문집
    • /
    • 한국마이크로전자및패키징학회 2001년도 추계 기술심포지움
    • /
    • pp.21-27
    • /
    • 2001
  • Epoxy/BaTiO$_3$composite film type capacitors with excellent stability at room temperature, uniform thickness, and electrical properties over a large area were successfully fabricated. We fabricated composite capacitor films with good film formation capability and easy process ability, from ACF-resin as a matrix and two kinds of BaTiO$_3$powders as fillers to increase the dielectric constant of the composite film. The crystal structure of the powders and its effects on dielectric constant of the films were investigated by X-ray diffraction. DSC and dielectric properties tests were conducted to decide the right curing temperature and the optimum amount of the curing agent. As a result, the capacitors of $7{\mu}{\textrm}{m}$ thick film with 10nF/cm2 and low leakage current were successfully demonstrated.

  • PDF