Effect of Immersion in Water and Thermal Cycling on the Mechanical Properties of Light-cured Composite Resins

광중합형 수복용 복합레진의 기계적 성질에 미치는 수중침적과 Thermal Cycling의 영향

  • Bae, Tae-Sung (Department of Dental Materials, and Institute of Dental Science, School of Dentistry, Chonbuk National University) ;
  • Kim, Tae-Jo (Department of Dental Materials, and Institute of Dental Science, School of Dentistry, Chonbuk National University) ;
  • Kim, Hyo-Sung (Department of Dental Materials, and Institute of Dental Science, School of Dentistry, Chonbuk National University)
  • 배태성 (전북대학교 치과대학 치과재료학교실 및 치의학 연구소) ;
  • 김태조 (전북대학교 치과대학 치과재료학교실 및 치의학 연구소) ;
  • 김효성 (전북대학교 치과대학 치과재료학교실 및 치의학 연구소)
  • Published : 1996.09.01

Abstract

This study was performed to investigate the effec% of immersion in water and thermal cycling on the mechanical peoperties of light cured restorative composite resins. Five commerically available light-cured composite resins(Photo Clearfil A : CA, Lite-Fil A . LF, Clearril Photo Posterior CP, Prisms AP.H.. PA, 2100 : ZH) were unto The specimens of 12 m in diameter and 0.7 m in thickness were made, and an immersion in $37^{\circ}C$ water for 7 days and a thermal cycling of 1000 cycles at 15 second dwell time each in $5^{\circ}C$ and $55^{\circ}C$ baths were performed. Biaxial flexure test was conducted using the ball-on-three-ball method at the crosshead speed of 0.5mm/min. In order to investigate the deterioration of composite resins during the thermal cycling test, Weibull analysis for the biaxial flexure strengths was done. Fracture surfaces and the surfaces before and after the thermal cycling test were examined by SEM. The highest Weibull modulus value of 10.09 after thermal cycling tests which means the lowest strength variation, was observed in the CP group, and the lowest value of 4.47 was obsered in the LF Group. Biaxial flexure strengths and Knoop hardness numbers significantly decreased due to the thermal cycling ($\textit{p}$< 0.01), however, they recovered when specimens were drie4 The highest biaxial flexure strength of 125.65MPa was observed in the ZH group after the thermal cycling test, and the lowest value of 64.86MPa was observed in the CA group. Biaxial flexure strengths of ZH and CP groups were higher than those of PA, CF, and CA groups after thermal cycling test($\textit{p}$< 0.05). Knoop hardness numbers of CP group after the thermal cycling test was the highest(95.47 $\pm$ 7.35kg/$mm^2$) among the samples, while that of CA group was the lowest(30.73 $\pm$ 2.58kg/$mm^2$). Knoop hardness numbers showed the significant differences between the CP group and others after the thermal cycling test(($\textit{p}$< 0.05). Fracture surfaces showed that the composite resin failure developed along the matrix resin and the filler/resin interface region, and the cracks propagated in the conical shape from the maximum tensile stress zone.

Keywords

References

  1. Ann. Surg. v.178 no.3 Biologic failure of autogenous vein implants as arterial substitutes Szilagyi D.E.;Elliot J.P;Hageman J.H.;Smith R.F.;Dallolomo C.A.
  2. Nato ASI series Synthetic membranes-science, engineering and application Strathmann, H.
  3. J. Vasc. Surg. v.10 no.3 Optimal graft diamete: Effect of wall shear stress on vascular healing Binns, R.L.;Ku D.N.;Stewart, M.T.;Ansley, J.P.;Coyle, K.A.
  4. J. Vasc. Surg. v.10 Effect of compliance mismatch on vascular graft failure Abbot, W.M.;Mergerman, J.E.;Warnock, D.F.
  5. J. of Vasc. Surg. v.3 no.4 Suture technique and para-anastomotic compliance Hasson, J.E.;Mergermann, J.;Abbott, W.M.
  6. Proc. of the 5th Int. Biophy. Congress Axial stress near host artery-synthetic graft anastomosis Passche, P.E.;Marble A.E.;McDonald, A.S.;Cochkanoff, O
  7. J. of Biomech. Eng. v.114 Vascular fluid mechanics, the arterial wall and atherosclerosis Nerem, R.M.
  8. J. Cardiovasc. Surg v.21 Compliance: a continuing problem with vascular grafts Kinley, C.E.;Marble, A.E.
  9. Surgery v.75 Stress at vascular anastomosis in relation to host artery; Synthetic graft diameter Kinley, C.E.;Paasche, P.E.;McDonald, A.S.;Marble, A.E.;Gozna, E.R.
  10. Cir. Res. v.22 Acute vascular endothelial changes associated with increased velocity gradients Fry, D.L.
  11. Biorheology v.17 Hemorheology of turbulence Stein, P.D.;Sabbah, H.N.
  12. J. Biomechanics v.26 Spatial and temporal variations of wall shear stress within an end-to-side arterial anastomosis model Ojha, M.
  13. Advances in Bioengineering v.BME 31 Flow characteristics in tapered vascular grafts Rhee, K.;Lee, D.G.
  14. J. Biomechanics v.27 A study of the wall shear rate distribution near the end-to-end anastomosis of rigid graft and a compliant artery Rhee, K.;Tarbell, J.M.
  15. J. Phys. E: Sci. Instrum. v.21 Development and evaluation of a high resolution photochromic dye method for pulsatile flow studies Ojha, M.;Hummel, R.L.;Cobbolt, R.S.C.;Johnston, K.W.
  16. Atherosclero-sis v.5 Pulsatile flow and atherosclerosis in the human carotid bifurcation : positive correlation between plaque localization and oscillating shear stress Ku, D.N.;Giddens, D.P.;Zarins, C.K.;Gragov, S.
  17. Acta Chir Scand v.142 Hemodynamics in arterial reconstructions of the lower limb: 1. Blood flow Dedichen, H.
  18. Biorheo. v.23 The effects of non-Newtonian viscosity and wall elasticity on flow at a 90° bifurcation Ku, D.N.;Liepsch, D.