• Title/Summary/Keyword: Residential Architectural

Search Result 535, Processing Time 0.026 seconds

Evaluating the Wind-induced Response of Tall Building Changed by Arrangements of the Buildings (건물배치변화에 따른 고층건축물의 풍응답 평가)

  • Cho, Sang Kyu;Ha, Young Cheol;Kim, Jong Rak;Kim, Kyu Suk
    • Journal of Korean Society of Steel Construction
    • /
    • v.16 no.3 s.70
    • /
    • pp.305-314
    • /
    • 2004
  • Many residential buildings and mixed-use (i.e., residential and commercial) buildings that are currently under construction in the country mainly consist of building clusters rather than single structures. Recent trends show single buildings that actually consist of two houses. The lower part of the building consists of a single dwelling space. However, the upper part of the building is split into two dwellings, considering the aspects of commercialism and appearance, such as ventilation and lighting. These tall and complex buildings not only have low mass and damping. They also depend on wind loads for their structural stability and serviceability, due to the interaction between the building groups and the wind. In architectural design, however, the interaction effects among neighboring houses within a building group have yet to be identified. In addition, it is difficult to predict these interaction effects. In this regard, this thesis aims to model patterns of architecture, which consist of two houses that are existing or under construction. Current structures are investigated by comparing their wind-reduced response interaction effects, based on the measured distance between two buildings, and the acceleration response through the wind tunnel test. The results of this study are expected to provide basic data for wind-induced response interaction effects of building groups. Furthermore, the outcomes are also intended to be used as data for more rational and economical structure design.

A Study on the Improvement of District Unit Plan in Apartment Housing with the Increase of 1~2 person Households (소가구 증가에 대응한 공동주택지 지구단위계획 개선방안)

  • Yoon, Jeong-Joong;Choi, Sang-Hee
    • Journal of the Korean Regional Science Association
    • /
    • v.34 no.3
    • /
    • pp.29-42
    • /
    • 2018
  • Population growth in Korea is slowing down, and the ratio of 1~2 person households has exceeded 53.3% of the total. And in the future, it is becoming more important how to accommodate as proper planning in residential areas. In this paper, we examine whether the existing district unit plans respond appropriately to the trend of the increase in small-sized housing, and we propose improvement plans for elements of the district unit plan and measures to enhance its applicability in response to small-sized housing. To do this, we analyzed the guidelines and contents of the district unit plans related to small-sized housing in recent 6 residential sites, and derived problems and improvements through literature review and expert consultation. As a result of the study, we proposed the items that need to be reflected in the district unit plan related to various housing type for one person household. And planning elements related to households, housing site, building layout, and architectural shape and appearance were also proposed, which were suitable for single-person households, such as small-sized communal housing, share-house, and single-person housing. It also suggested that single-person households should be considered for housing characteristics, including introduction of auxiliary welfare facilities such as unmanned delivery box and guest houses, and exclusion of low-demand auxiliary welfare facilities such as kindergartens. The suggested content can be used to make guidelines for small-sized housing in district unit plan.

Fragility Analysis of RC Moment Resisting Frame with Masonry Infill Walls (비내력벽을 가진 RC모멘트저항골조의 취약도 해석)

  • Ko, Hyun;Park, Yong-Koo;Lee, Dong-Guen
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.22 no.4
    • /
    • pp.355-362
    • /
    • 2009
  • Many of residential buildings, which have pilotis in lower stories to meet the architectural needs, are recently constructed in Korea. Usually, infill walls located in the upper stories of these buildings may cause a soft first story, which is very weak from the earthquake resistance. In the design of the buildings, the infill walls of upper stories are usually considered as non-structural elements and thus they are not included in the analytical model. However, the infill walls may affect the seismic behavior of the residential buildings. Therefore, the differences in seismic behaviors of RC buildings with and without masonry infill walls are required to be investigated. In this study, seismic fragility analyses were performed for masonry infilled low-rise RC moment-resisting frames. And seismic behaviors of RC moment-resisting frame with/without masonry infill walls were evaluated. Two types of structural system with the same frame and different allocation of infill walls are used to evaluate the influence of masonry infill walls on seismic behavior of RC moment-resisting frames. The infill walls were modeled as bi-equivalent diagonal struts. The fragility analyses show that the seismic performance of RC moment-resisting frames with soft story is below the desirable building seismic performance level recommended by current seismic codes, indicating high vulnerability of RC moment-resisting frames with soft story.

An Empirical Study on the Thermal Performance and Dynamic Behavior of Wall Integrated Thermosiphon Solar Water Heater (벽체일체형 자연순환 태양열온수기의 동적거동과 열성능에 관한 실증연구)

  • Baek, Nam-Choon;Kim, Sung-Bum;Shin, U-Cheul
    • Journal of the Korean Solar Energy Society
    • /
    • v.36 no.6
    • /
    • pp.25-35
    • /
    • 2016
  • In this study, the evaluation of the dynamic behavior and thermal performance of the "Façade integrated Natural circulation Solar Water Heating System" installed in the residential house was carried out. Experimental tests were performed during the all year around in the rural houses of $166m^2$ in size. Facade integrated solar collector of $5m^2$ were installed on the south-facing. Electrical heater of 1 kW capacity as an auxiliary heater was installed at the upper part of the heat storage tank. The analyzing results are as follows. (1) Monthly average solar fraction was 51 to 87% and yearly average value is 64%. (2) Hot water supply temperature in December which has the lowest solar altitude is 37 to $76^{\circ}C$. The highest working fluid temperature of solar collector in this period was below $84^{\circ}C$. The temperature difference of working fluid between the collector inlet and outlet has been shown to be around 9 to $26^{\circ}C$. (3) Overheating which is one of the biggest problems during summer did not appear at all, but rather had hot water supply temperature is rather low as $30{\sim}47^{\circ}C$ in summer than winter, which is supplied by a small solar load. The solar collecting temperature has been shown to maintain below $55^{\circ}C$. (5) The thermal performance of Facade integrated solar collector can be increase due to the reduction of heat loss to the back of the collector wall integration of the collector is reduced. As a conclusion, Facade integrated natural circulation type Solar Water Heating System is a well-functioning without any pumps or controllers, and it was found that the disadvantages of conventional solar water heaters, hot water or hot water system can be greatly improved.

A Probabilistic Risk-based Cost Estimation Model for Initial-Stage Decision Making on Apartment Remolding Projects (공동주택 리모델링 초기 단계 의사결정을 위한 확률론적 리스크 기반 비용 예측 모델 개발)

  • Lee, Dong-gun;Cha, Heesung
    • Korean Journal of Construction Engineering and Management
    • /
    • v.17 no.2
    • /
    • pp.70-79
    • /
    • 2016
  • The current remodeling cost estimation process is not only dependent on the historical data of new building construction, but it also has a poor linkage with risk-based estimation approach. As such, there is a high risk of falling short of initial budget. To overcome this, a risk-based estimation approach is necessary by providing a probabilistic estimation in consideration of the potential risk factors in conducting the remodeling projects. In addition, the decision-making process should be linked with the risk-based estimation results in stead of intuitive and/or experience-based estimation. This study provides a probabilistic estimation process for residential remodeling projects by developing a detailed methodology in which a step-by-step approach can be achieved. The new proposed estimation approach can help in decision-making for remodeling projects in terms of whether to proceed or not, by effectively reflecting the potential risk factors in the early stage of the project. In addition, the study can enhance the reliability of the estimation results by developing a sustainable estimation process model where a risk-based evaluation can be accomplished by setting up the cost-risk relationship database structure.

A study on the Changes in form and spatial uses of Urban Hanok in Bukchon, Seoul (서울 북촌한옥의 변화양상에 관한 연구 - 북촌 가꾸기 사업에 따른 2002~2007 한옥 대수선 사례를 대상으로 -)

  • Song, In-Ho;Kim, Young-Soo;Cho, Eun-Joo
    • Journal of architectural history
    • /
    • v.18 no.2
    • /
    • pp.47-63
    • /
    • 2009
  • This study focused on changes in form and spatial uses of Urban Hanok in Bukchon, Seoul. There are 10 representative cases which have been renovated through the policy of 'Preservation & Regeneration of Bukchon' by Seoul metropolitan government and other experts. Changes in form and spatial uses of Urban Hanok in Buckon are as follows. First, Changes of scale. Trough removing extension parts, facade of renovated Hanoks are 'transformed' into recovering their identity. Using basements or lofts, intensive application of spaces is transformation which promotes the vitality of Hanoks. Second, changes of space organization. As Hanok changes its function from residence to commercial or cultural use, il a1so changes space character or reorganizes space organization. It is important that deciding function of Hanok has to adjust its scale and organization. Third, changes of construction performance. Through introducing new material and constructing method, performance of wall has been changed respecting its wooden structure and interior-exterior figure. However, technical studies must back it up not to destroy its value of eco-friendly architecture. Fourth, changes of facility systems, like floor heating system. They changes floor level of Hanok equally, and then sections of Hanok have became simple. Furthermore, inserting new facility space, such as boiler room, stand-up kitchen, bathroom and toilet, organization of space also changed. It is necessary that wise alternative proposal through the method of transformation or mutation must be presented. These four changes can be classification into method of 'transformation' and 'mutation'. Changes of scale are method of transformation and changes of space organization are method of mutation. Also, while changes of construction performance are mutation, changes of facility systems are transformation. Recently, as price of lots have been increased, a lot of Hanoks have been commercialized. Thc commercial energy threat 'the identity of Bukchon as residential area'. From now on, to operate 'identity' and 'vitality' complementary, it is necessary to make up for the preservation policy of Hanok and consolidate renovating standards of Hanok which correspond to character of particular region and building usage.

  • PDF

Evaluation of Seismic Capacity and Estimation of Earthquake Damage for Existing Unreinforced Masonry Building in Korea (국내 조적조 건물의 내진성능평가 및 지진피해율 상정)

  • Kang, Dae-Eon;Yi, Waon-Ho
    • Journal of the Korea Concrete Institute
    • /
    • v.18 no.4 s.94
    • /
    • pp.535-542
    • /
    • 2006
  • In Seoul, more than 80 percent of residential buildings are constructed with unreinforced masonry(URM) buildings in early 1970 to 1990. In general, URM buildings have the advantages of reducing the construction time and easy to construction. However, URM buildings do not have enough strength against the lateral force. Moreover, low rise buildings have not adopted seismic designs, and for that reason a critical damage is expected with an earthquake. And also, the necessity of the seismic performance evaluation of existing building structures is raised through the Taiwan earthquake in 1999. The purpose of this study is to provide basic information for unreinforced masonry building in Korea by application of the proposed seismic evaluation method. In this study, seismic capacities of 50 existing unreinforced masonry buildings are evaluated based on the proposed method. Also, relationships of seismic capacities between Korean earthquake damage ratios of korean unreinforced masonry buildings are estimated. Results of this study were as follows; 1)Seismic retrofit was needed $8{\sim}48%$ in Korean unreinforced masonry buildings. 2)Korean unreinforced masonry buildings were expected to have severe damage under the earthquake intensity level experienced in Japan.

Investigation of Disputes for Nominated Sub-contractor(NSC) -Focused on the Judicial Precedent of NSC issues in Singapore, Malaysia and Hong Kong- (아시아 건설 시장에서의 지정하도급자(NSC)문제에 관한 연구 - 싱가포르, 말레이시아 그리고 홍콩의 판례를 중심으로 -)

  • Cho, Jaeyong;Kim, Junggon;Park, Hyeonggeun;Kim, Youngsuk;Lee, Boknam
    • Korean Journal of Construction Engineering and Management
    • /
    • v.16 no.6
    • /
    • pp.112-123
    • /
    • 2015
  • Many disputes are happened with various causes in overseas construction projects. One of major disputes is closely related with nominated subcontractors (NSC). This paper investigates 30 judical precedents for Singapore, Malaysia and Hongkong to analyze the detailed disputes related with the NSC, and then the judical precedents are classified into 6 categories: Delay and Defect Trouble (T1), Contract Relation (T2), Payment Trouble (T3), Set-off (T4), Liquidation (T5) and so forth (T6). According to the analytical results, the frequency of occurrence of disputes is considerably related with social and economical changes, and the dispute between NSC and employer for residential and commercial building projects is the most frequently happened case. As the results of analysis, therefore, it is concluded that the employer needs to response aggressively to the problems related with NSC, and it is also important to make the council for communication among related bodies. Furthermore, the institutional reform that make the role and the responsibility of employer consistent under considering contract terms and conditions is considered as the most important and fundamental issue.

An Study of Pedestrian Efficiency in Apartment Complexes - Focused on Pedestrian Path in Apartment Complexes - (아파트 단지의 보행효율성에 관한 연구 - 단지 내 보행로를 중심으로 -)

  • Yang, Dongwoo;Yu, Sang-Gyun
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.34 no.11
    • /
    • pp.85-94
    • /
    • 2018
  • This study aims to investigate how easy pedestrians get around within/through the "Apartment Complexes (AC), " a common style of high-rise multi-family housing in Korea. Over the past six decades, the AC has been the most conventional way to provide standardized housing efficiently to address the problems of the shortage of housing and the substandard housing, due to the explosion of urban population with the rapid industrialization. The AC is a huge chunk of homeogenous multi-family housing, mostly condos with decent infrastructure, including parks, pedestrian passages, schools, ect. Both in the new town development and urban renewal programs have utilized the advantages of the AC. Since the design principals of AC tend to adopt the "protective design" to prevent cars and pedestrians coming outside from passing it, it has been criticised for dissecting the continuity of socioeconomic context in neighborhoods. The neo-traditional planning urbanists, including Jane Jacobs, emphasize that smaller blocks and grid road newtworks are the key in improving social, cultural, and economic vitality of the neighborhoods, because these design concepts allow more pedestrians and different types of people to be mixed in a neighborhood. In this study, we first adopted objective measures for pedestrian accessibility and pedestrian efficiency. These measures were used to calculate the lengths of shortest paths from residential buildings to the edges of AC. We tested the difference in shortest paths between the current pedestrian networks of AC and hypothetical grid networks on the AC, and the relative difference is considered as the pedestrian efficiency, using the network analysis function of Geographic Information Systems (GIS) and Python programming. We found from the randomly selected 30 ACs that the existing non-grid road networks in ACs are worse than the hypothesized grid networks, in terms of pedestrian efficiency. In average, pedestrians in AC with the conventional road networks have to walk than 25%, 26%, and 27% longer than the networks of $125{\times}45m$, $100{\times}45m$, and $75{\times}45m$, respectively. With the t-test analysis, we found the pedestrian efficiency of AC with the conventional network is lower than grid-networks. Many new urbanists stress, easiness of walking is one of the most import elements for community building and social bonds. With the findings from the objective measures of pedestrian accessibility and efficiency, the AC would have limitations to attract people outside into the AC itself, which would increase dis-connectivity with adjacent areas.

A Study on the Publicness of Brooklyn Navy Yard Industrial Business Zone - Focus on Policy, Managerial Responses - (브루클린 네이비 야드 산업단지의 공공성에 대한 연구- 정책·운영적 대응을 중심으로 -)

  • Yun, Jun-hyuk;Lee, Kang-jun
    • Journal of Urban Science
    • /
    • v.11 no.1
    • /
    • pp.49-57
    • /
    • 2022
  • Semi-industrial zone is the area where manufacturing, residential, commercial zones are mixed. Despite of their potentials in that proximity to city and convenient transportation infrastructure, a lot of semi-industrial zones in Korea have converted to other uses due to many issues such as change of industry, increasing land price, real estate speculations. Recently, local government is trying to solve their existing issues and develop them through a restoration of publicness. Now publicness is thought of as a key factor of regeneration in semi-industrial areas. In this regard, this study aims to examine the way of restoring publicness revealed in Brooklyn Navy Yard mainly focus on their urban contexts and architectural ways. Brooklyn Navy Yard, an exemplary case, is an industrial complex that has grown economically, socially and culturally through emphasizing publicness and it is evaluated as an advanced example of public industrial complex. Through the analysis of Navy Yard, this study was trying to emphasize the importance of publicness in the regeneration of semi-industrial areas and to provide implications for the Seoul Government's solutions, which are still in the conceptual stage. To analyze the publicness of the study subjects, framework and elements were derived by examining related theories and prior researches. Depending on this frame, the results of the publicness of the Navy Yard were as follows. First of all, the 'Publicness as an officiality' was identified at the characteristic of the site and Navy Yard development corporation. Second, the 'Publicness as a public interest' of the Navy Yard Development Corporation was identified in various ways of its operation methods. Finally, the 'Publicness as an accessibility' was identified in the opening of urban and architectural spaces in Navy Yard. These publicness were analyzed with seven Navy Yard's success factors. Thus, it can be interpreted that the publicness of the semi-industrial areas can contribute significantly to their success. The publicness restoring methods of Navy Yard could be used as a basic data in semi-industrial areas in the future in Korea. However they are limited to be applied directly, so extensive and in-depth research in terms of their applicability should be conducted.