• Title/Summary/Keyword: Research Efficiency

Search Result 17,263, Processing Time 0.069 seconds

Stabilizing Soil Moisture and Indoor Air Quality Purification in a Wall-typed Botanical Biofiltration System Controlled by Humidifying Cycle (가습 주기에 따른 벽면형 식물바이오필터의 토양 수분 안정화 및 실내공기질 정화)

  • Lee, Chang Hee;Choi, Bom;Chun, Man Young
    • Horticultural Science & Technology
    • /
    • v.33 no.4
    • /
    • pp.605-617
    • /
    • 2015
  • The ultimate goal of this research is to develop a botanical biofiltration system that combines a green interior, biofiltering, and automatic irrigation to purify indoor air pollutants according to indoor space and the size of biofilter. This study was performed to compare the stability of air flow characteristics and removal efficiency (RE) of fine dust within a wall-typed (vertical) botanical biofilter depending on humidifying cycle and to investigate RE of volatile organic compounds (VOCs) by the biofilter. The biofilter used in this experiment was designed as an integral form of water metering pump, water tank, blower, humidifier, and multi-level planting space in order to be suitable for indoor space utilization. As a result, relative humidity, air temperature, and soil moisture content (SMC) within the biofilter showed stable values regardless of three different humidifying cycles operated by the metering pump. In particular, SMCs were consistently maintained in the range of 27.1-29.7% during all humidifying cycles; moreover, a humidifying cycle of operating for 15 min and pausing for 45 min showed the best horizontal linear regression (y = 0.0008x + 29.09) on SMC ($29.0{\pm}0.2%$) during 120 hour. REs for number of fine dust (PM10) and ultra-fine dust (PM2.5) particles passed through the biofilter were in the range of 82.7-89.7% and 65.4-73.0%, respectively. RE for weight of PM10 passed through the biofilter was in the range of 58.1-78.9%, depending on humidifying cycle. REs of xylene, ethyl benzene, total VOCs (TVOCs), and toluene passed through the biofilter were in the range of 71.3-75.5%, while REs of benzene and formaldehyde (HCHO) passed through the biofilter were 39.7% and 44.9%, respectively. Hence, it was confirmed that the wall-typed botanical biofilter suitable for indoor plants was very effective for indoor air purification.

The Weight Analysis of Evaluation Indicators for Assessing Livestock Manure Treatment System and its Technology by AHP (AHP를 활용한 가축분뇨 처리시설 및 관련기술 평가지표 가중치 설정)

  • Kim, J.H.;Cho, S.H.;Kwag, J.H.;Choi, D.Y.;Jeong, K.H.;Cheon, D.W.;Lee, S.H.;Kim, J.H.;So, K.H.;Park, C.H.
    • Journal of Animal Environmental Science
    • /
    • v.17 no.sup
    • /
    • pp.51-60
    • /
    • 2011
  • The objective of this study was to suggest strategies for improving "Livestock Manure Treatment Systems and Related Technologies Assessment Program". Analytic Hierarchy Process (AHP) was used to evaluate reasonableness of applied weight value for assessment and improve program management strategies. Results of mail survey collected from animal manure treatment technology specialists of 30 companies nationwide were used for AHP. Company's ability, technological prowess, facility's convenience, economic feasibility are four important aspects of assessment program evaluation using AHP. More than 70% of the respondents said they were overall satisfied with the objectivity of assessment program regarding above four evaluation aspects. However, only 36% of them answered that they were very satisfied with the objectivity of assessment program in terms of economic feasibility. The evaluation results revealed that the assessment program needs to be made up for the weak points regarding economic feasibility. The AHP weight calculation results showed that the current assessment program overestimates the technological prowess, especially livestock manure treatment efficiency. It suggests that the weight value of current assessment program in terms of technological prowess needs to be determined carefully. The current assessment program combined with AHP weight value determination approach will be very useful to improve objectivity and reliability of assessment.

The Study of Genetic Diversity for Drought Tolerance in Maize (옥수수 한발 내성에 관한 유전적 다양성 조사)

  • Kim, Hyo Chul;Lee, Yong Ho;Kim, Kyung-Hee;Shin, Seungho;Song, Kitae;Moon, Jun-Cheol;Lee, Byung-Moo;Kim, Jae Yoon
    • Korean Journal of Environmental Biology
    • /
    • v.34 no.4
    • /
    • pp.223-232
    • /
    • 2016
  • Drought is one of important environmental stress for plant. Drought has deleterious effect to plant growth including maize (Zea mays L.) such as vegetative and/or reproductive growth, root extension, photosynthesis efficiency, flowering, anthesis-silking interval (ASI), fertilization, and grain filling. In this study, we screened drought tolerant maize in 21 cultivars from different sources, sixteen NAM parent lines (B73, CML103, CML228, CML247, CML277, CML322, CML333, CML69, Ki11, Ki3, Ky21, M37W, Mo18w, NC350, Oh43 and Tx303), four Korean hybrids (Cheongdaok, Gangdaok, Kwangpyeongok and Pyeonganok) and one Southeast Asian genotype (DK9955). Drought stress (DS) index was evaluated with leaf rolling score at seedling stage and ASI at silking date. The leaf rolling scoring of CML228, DK9955 and Ki11 were determined 1.28, 1.85, 1.86, respectively. However, M37W, Kwangpyeongok, B73 and NC350 were determined over the 3. ASI analysis revealed that CML228, CML103, Cheongdaok, NC350, B73, CML322, Kwangpyeongok and Ki11 are represented less than 5 days under DS and less than 3 days of difference between DS and well-watered (WW), but CML69, Ki3, Pyeonganok, M37W, Mo18w and Gangdaok were represented more than 10 days under DS and more than 8 days of difference between DS and WW. Multi-Dimensional Scaling (MDS) analysis determined CML228, Ki11, and CML322 were regarded as drought tolerance cultivars. Eventually, Ki11 showed genetic similarity with Korean cultivars by QTL analysis and MDS analysis. Ki11 has a potential for development of drought tolerance maize with Korean cultivars.

Formulation of Bacillus amyloliquefaciens A-2 and Its Efficacy to Control Tomato Leaf Mold Caused by Fulvia fulva (길항세균 Bacillus amyloliquefaciens A-2를 이용한 토마토 잎곰팡이병 방제용 미생물 제제)

  • Kong, Hyun-Gi;Chun, Ock-Joo;Choi, Ki-Hyuck;Lee, Kwang-Youll;Baek, Joung-Woo;Kim, Hyun-Ju;Murugaiyan, Senthilkumar;Moon, Byung-Ju;Lee, Seon-Woo
    • Research in Plant Disease
    • /
    • v.16 no.1
    • /
    • pp.27-34
    • /
    • 2010
  • This study was performed to develop a formulation using an antagonistic bacterium Bacillus amyloliquefaciens A-2 to control tomato leaf mold caused by Fulvia fulva. B. amyloliquefaciens A-2 was grown in a medium with rice oil and mixed with various carrier and additives. One of the formulations, A2-MP, showed the best disease control value among the tested formulations. The disease control value of A2-MP at 100-fold and 500-fold diluted treatment was not significantly different from that of chemical fungicide triflumizole in a growth chamber. Although disease control effect was decreased by serial diluted treatment of the prepared A2-MP, 1,000-fold diluted treatment of A2-MP still showed high disease control value of 72.0%. For the green house experiments, the disease control values of A2-MP was indicated as 79.4% which is similar to that of chemical fungicide, triflumizole showing 79.6%. When the disease control activity of the formulation A2-MP was compared in tomato production conditions, disease control values of 100-fold diluted A2-MP and 3,000 fold diluted triflumizole exhibited 60%, 81.6%, respectively. The disease control efficiency by A-2MP was 73% of the disease control value of chemical fungicide. The formulation A-2MP maintained the stable bacterial viability and disease control activity when stored at $4^{\circ}C$. This result suggested that A-2MP develped from B. amyloliquefaciens A-2 could be used to control tomato leaf mold.

Analysis of Dose Reduction Rate with Dose Modulation Technic Depending on BMI (PET/CT검사에서 Dose Modulation Technic 적용시 BMI에 따른 선량 감소율 분석)

  • Kim, Jung Wook;Park, Se Yun;Jo, Young Jun;Park, Jong Yeop
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.25-28
    • /
    • 2012
  • Purpose : It is important to reduce radiation dose associated with computed tomography (CT) scanning to as low as reasonably achievable (ALARA). With Dose Modulation Technic, user select a desired image quality and the system adapts tube current to obtain the desired image quality with greater radiation dose efficiency. In this paper, we presents a comprehensive description of fundamentals, clinical applications and radiation dose benefits of Dose Modulation Technic depending on Body Mass Index(BMI). Materials and Methods : In this study, 149 patients were examined(The mean age : $58{\pm}12.4$ years old). Biograph True Point 40 (Siemens, USA) and Gemini TF 64 (Philips. Cleveland) were used for equipment. When we used Care Dose 4D (Siemens, USA) and D-dom (Philips, Cleveland), we measured dose reduction and Computed Tomography Dose Index (CTDI) depending on BMI. Then we analyze data using SPSS Ver.18. Results : When we used Care Dose 4D, p-value is considered statistically significant by groups with the result that we compared Care Dose 4D with D-dom. On the other hand, p-value isn't considered statistically significant by groups using D-dom. Conclusion : Dose modulation based on the projection angle didn't affect degree of obesity. And When using Care Dose 4D, dose reduction rate in the normal patients were higher than the obese. In this study, there are errors on somato type. So I think more research have to be done. Then application of Dose Modulation technic can help in maintaining acceptable image quality while reducing radiation dose by 20-60% in most instances.

  • PDF

The Study on Risk Factors Analysis and Improvement of VDT Syndrome in Nuclear Medicine (핵의학과 Video Display Terminals Syndrome 유해 요인 조사 및 개선에 관한 연구)

  • Kim, Jung-Soo;Kim, Seung-Jeong;Lee, Hong-Jae;Kim, Jin-Eui;Kim, Hyun-Joo;Han, In-Im;Joo, Yung-Soo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.61-66
    • /
    • 2010
  • Purpose: Recently, Department of Nuclear Medicine have an interest in Video Display Terminals (VDT) syndrome including musculoskeletal disorders, ophthalmologic disorders, trouble of electromagnetic waves and stress disorders occur to VDT workers as the growing number of users and rapid pace of service period supply in large amount. This study research on the actual condition for VDT syndrome in Nuclear Medicine, Seoul National University Hospital (SNUH), discover the problem and draw a plan of upcoming improvement. The aim of this study establish awareness about VDT syndrome and is to prevent for it in the long run. Materials and Methods: Department of Nuclear Medicine, SNUH is composed Principle part, Pediatric part and PET center. We estimated risk factors visit in each part directly. Estimation method use "Check list for VDT work" of Wonjin working environment health laboratory and check list is condition of VDT work, condition of work tables, condition of chairs, condition of keyboards, condition of monitors, working position, character of health management and other working environment. Analysis result is verified in Department of Occupational and Environment, Hallym University Sacred Heard Hospital. Results: As a result of analysis, VDT condition of Department of Nuclear Medicine, SNUH is rule good. In case of work tables, recent of things are suitable to users upon the ergonomical planning, but 15% of existing work tables are below the standard value. In case of chairs are suitable, but 5% of theirs lost optimum capacity become superannuated. The keyboards are suitable for 98% of standard value. In case of monitors, angle control of screen is possible of all, but positioning control is impossible for 38%. In case of working position, 10% is fixed positioning for long time and some of the items researched unsuitable things for standard. At health management point, needed capable of improvement. Also, other working condition as lighting, temperature, noise and ventilation, discovered the problem, but is sufficient to advice value. Conclusion: VDT syndrome is occurrences of possibility continuously, come economical expensive about improvement, is inherent in various causes and originate without your knowledge. So, there is need systematic management system. In Nuclear Medicine, VDT syndrome make it better that constant interest and effort as improvement of ergonomical working environment, improvement of working procedure, regular exercise and steady stretching, and can be prevented fairly. This promote physical and mental condition of worker in top form in comfortable working environment, so this is judged by enlargement of operations efficiency and rising of satisfaction ratings of the inside client.

  • PDF

The Research about the Classification System Improvement and Cord Development of Korean Classification of Disease on Oriental Internal Medicine (한국표준질병사인분류중 한방내과영역의 분류체계 개선 및 진단명 구성에 관한 연구)

  • Lee, Won-Chul
    • The Journal of Internal Korean Medicine
    • /
    • v.31 no.1
    • /
    • pp.1-10
    • /
    • 2010
  • Objectives : It is necessary that the international classification of diseases (ICD) be examined in order to comprise the third revision of the Korean Classification of Disease on Oriental Medicine (KCD-OM) and disease classification in the oriental internal medicine field. It is essential that the selection, classification and definition of disease and pattern names of oriental concepts in internal medicine be clear. Since 2008, the fifth revision of the Korean Classification of Disease (KCD-5) has been used in Korea. It was required to use the reference classification from the Oriental medicine area based on the ICD-10. Methods : In this review, the necessity for, meaning of and content of the third revision are briefly described. The ICD system was reviewed and KCD-OM was reconstructed. How diagnosis in the oriental internal medicine area had changed is discussed. Review and Results : In 1973, the disease classification of oriental medicine was established the basis on the contents of Dongeuibogam. It was irrespective of the ICD. As to the classification system in the Oriental internal medicine field, systemic disease was comprised of wind, cold, warm, wet, dryness, heat, spirit, ki, blood, phlegm and retained fluid, consumptive disease, etc. Diseases of internal medicine comprised a system according to the five viscera and the six internal organs and followed the classification system of Dongeuibogam. The first and second revisions were of the classification system based on the curriculum in 1979 and 1995. In 1979, in the first revision, geriatric disease and idiopathic types of disease were deleted, and skin disease was included among surgery diseases. This classification was expanded to 792 small classification items and 1,535 detailed classification items to the dozen disease classes. In 1995, in the second revision, it was adjusted to 644 small classes and 1,784 detailed classification items in the dozen disease classes. KCD-OM3 did KCD from this basis. It added and comprised the oriental medical doctor's concept names of diseases considering the special conditions in Korea. KCD-OM3 examined the KCD-OMsecond revised edition (1994). It improved the duplex classification, improper classifications, etc. It is difficult for us to separate the disease names and pattern names in oriental medicine. We added to the U code and made one classification system. By considering the special conditions in Korea, 169 codes (83 disease name codes, 86 pattern name codes) became the pre-existence classification and links among 306 U codes of KCD-OM3. 137 codes were newly added in the third revision. U code added 3 domains. These are composed of the disease name (U20-U33, 97 codes), the disease pattern name (U50-U79, 191 codes) and the constitution pattern name of each disease (U95-U98, 18 codes). Conclusion : The introduction of KCD-OM3 conforms to the diagnostic system by which oriental medical doctors examine classes used with the basic structure of the reference classification of WHO and raises the clinical study and academic activity of the Korean oriental medicine and makes the production of all kinds of nation statistical indices possible. The introduction of KCD-OM3 promotes the diagnostic system by which doctors of Oriental medicine examine classes using the association with KCD-5. It will raise the smoothness and efficiency of oriental medical treatment payments in the health insurance, automobile insurance, industrial accident compensation insurance, etc. In addition, internationally, the eleventh revision work of the ICD has been initiated. It needs to consider incorporating into the International Classification of Diseases some of every country's traditional medicine.

Effect of Perforated PVC Underdrainage Pipe on Desalting of Plastic Film House Soils (시설재배지 유공관 암거배수에 의한 염류집적 경감효과)

  • Kim, Dae-Su;Yang, Jae E.;Ok, Yong-Sik;Yoo, Kyung-Yoal
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.39 no.2
    • /
    • pp.65-72
    • /
    • 2006
  • Objective of this research was to remove the accumulated salts in the plastic film house soils by installing the perforated PVC (${\phi}10cm$) underdrainage pipes at 50 cm depth of soils with cultivating vegetables. Efficiency of the underdrainage pipes was assessed based on the changes of soil chemical properties such as pH, EC, and cations, and growth and yield parameters of the vegetables between the two treatments; the control and the underdrainage pipe treatments. The EC of the underdrainage pipes installed soils after two growing seasons were in the ranges of $1.42-2.88dS\;m^{-1}$ but those of the control were in the ranges of $3.86-4.53dS\;m^{-1}$, indication the underdrainage pipes effectively removed the accumulated salts in soils. The pHs of the control soils and the underdrainage pipe installed soil were in the ranges of 7.2-7.5 and 6.9-7.3, respectively. There was a significant correlation between pH and cation exchange capacity (CEC) of the soils ($CEC=17.107{\times}pH-106.2$, $r^2=0.759$, P < 0.05). The ECs of the soils at different depths were compared between the two treatments after cultivating vegetables with lettuce-lettuce-garland chrysanthemum rotation systems. The ECs of the control soils at depths of 0-10, 10-20, 20-30, 30-40, and 40-50 cm were 3.45, 3.47, 3.03, 2.03, and $2.28dS\;m^{-1}$, respectively, with decreasing with soil depths. On the other hand, the respective ECs of the underdrainage pipes installed soils were 2.43, 2.52, 2.28, 4.00, and $4.23dS\;m^{-1}$ with increasing with soil depths. This might be derived from the salts moved downward with the draining water into the subsoil. The order of cations moved downward was Mg > Ca > K, based on the ratios of cations at specific depth over those at the surface soil. The survival rates of lettuce after 15 days of transplanting in the underdrainage pipe installed soils were 98.2% as compared to 86.6% of the control. The underdrainage pipe treatment also increased the diameter of the lettuce stalk from 12.9mm of the control to 13.7mm. Overall results demonstrated that the installment of the underdrainage pipes in the subsoils of the salt accumulated plastic film house soil effectively removed the salts by leaching downward,resulting in lowering soil EC and enhancing the growth and yield of vegetables.

Development and Animal Tests of Prototype Oxygen Concentrator (국산 산소 농축기의 개발 및 동물실험)

  • 변정욱;성숙환;이태수
    • Journal of Chest Surgery
    • /
    • v.31 no.7
    • /
    • pp.643-649
    • /
    • 1998
  • Background: For the patient with chronic obstructive pulmonary disease requiring long-term oxygen therapy, oxygen concentrator machines are already widely available for use in home. In this study, we used mongrel dogs as test subjects to compare the functional efficiency and safety of the oxygen concentrator developed by our own research team with those of the imported FORLIFE(TM) machine made by AIRSEP Corp. Method and method: To test mechanical reliability, the concentrations of oxygen delivered were measured after 4 hours of continuous operation. Sixteen mongrel dogs were divided into two equal groups. Mongrel dogs in group A were given oxygen using the imported oxygen concentrator, and those in group B using the machine developed. 5 l/min of oxygen were given, after which vital signs were analyzed, arterial blood gases measured, and blood chemistry tests carried out. Results: After 4 hours of continuous operation, the imported model performed better, giving 98${\pm}$3% oxygen, compared to our model, which gave 91${\pm}$1%. In the animal experiments, oxygen concentrations were measured at the inlet of face mask 1, 2, 3, and 4 hours after continuous administration, and there was no statistically significant difference(repeated measures of analysis of variance p=0.70) between the values of 70.6${\pm}$2.5%, 67.1${\pm}$2.9%, 68.2${\pm}$2.6%, and 64.9${\pm}$3.9% that were measured from group A, and the values of 65.1${\pm}$4.8%, 65.2${\pm}$3.6%, 68.7${\pm}$4.3%, and 66.0${\pm}$5.0% measured from group B. Before oxygen administration, and at 1, 2, 3, and 4 hours after oxygen administration, arterial blood partial pressure of oxygen 87.2${\pm}$2.5 mmHg, 347.4${\pm}$29.3 mmHg, 353.4${\pm}$21.2 mmHg, 343.0${\pm}$28.8 mmHg, and 321.6${\pm}$24.4 mmHg, respectively, were read from group A, which were not statistically different (p=0.24) to the values of 102.5${\pm}$9.6 mmHg, 300.3${\pm}$17.1 mmHg, 321.6${\pm}$23.7 mmHg, 303.4${\pm}$27.4 mmHg, and 273.5${\pm}$25.9 mmHg read from group B. Nonetheless, the arterial blood partial pressure of oxygen values appear to be somewhat higher in dogs that were given oxygen using the imported oxygen concentrator. Conclusions: From these results the prototype oxygen concentrator developed appears to function relatively satisfactorily compared to the imported, established model, but may be criticized for the excessive noise generated and poor long-term endurance or consistency, which need improvement.

  • PDF

A Validation Study for the Practical Use of Screening Scale for Potential Drug-use Adolescents(SPDA) (청소년 약물사용 잠재군 선별척도(SPDA) 활용을 위한 타당화 연구)

  • Lee, Ki-Young;Kim, Young-Mi;Im, Hyuk;Park, Mi-Jin;Park, Sun-Hee
    • Korean Journal of Social Welfare
    • /
    • v.57 no.3
    • /
    • pp.305-335
    • /
    • 2005
  • This paper is a result from validation study for SPDA(A Screening Scale For Potential Drug-use Adolescents) created in 2003 and newly developed during 2004. SPDA aims to screen adolescents in their early stage of drug-use and to help practitioners make a preventive approach for the adolescents. 4307 junior and senior high school students were selected as primary research subjects by stratified and quota sampling methods. 305 adolescents on probation were also selected as a comparison group and asked to answer the same questionnaire. Reliability for SPDA recorded 0.914, which proved to be better than previous year's (0.898). Exploratory and confirmatory factor analyses to test construct validity proved that SPDA could be divided into 7 factors and that each factor structure of SPDA could be a proper measurement model with high level of fitness and factor loadings. Discriminant analysis to test predictive validity confirmed that SPDA could classify the adolescents excellently by the frequency of drug-use, with hit ratio of 86.6 percent(78.8% and 87.4% for junior and senior high school students respectively). For concurrent validity test, Hare Home Self-Esteem Scale, Hare School Self-Esteem, Zuckerman-Kuhlman Sensation-seeking Scale were employed to find correlation with SPDA and all the three scales had significant Pearson correlation coefficients with SPDA. Known-groups validity test indicated that SPDA had an adequate power to classify out adolescents on probation from those in schooling, with a hit ratio of 71.8 percent. Cut-off point to detect adolescents with high risk of substance use was 77, which indicated approximately T score, 55 (0.5 SD), satisfying sensitivity, specificity, and efficiency criteria.

  • PDF