• Title/Summary/Keyword: Remaining service time

Search Result 86, Processing Time 0.034 seconds

An Analysis of Fire Area in Jinju City Based on Fire Mobilization Time (화재 출동시간에 근거한 진주시 소방권역 분석)

  • Koo, Seul;Yoo, Hwan Hee
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.20 no.4
    • /
    • pp.127-134
    • /
    • 2012
  • This study analyzed the present status of services by fire-suppression mobilization time of fire station where is located in Jinju city, by using network analysis of GIS targeting fire station(five 119 safety centers, one 119 division) in Jinju city area. As a result, it was indicated to be 15.9% in the ratio with less than 5 minutes of mobilization time, 34.7% in the ratio with less than 8 minutes, 94% in the ratio with less than 20 minutes out of the whole fire service area in Jinju city. Even districts with more than 20 minutes were analyzed to reach 6%. Especially, to solve vulnerability to approach the fire service in uptown districts(Jinseong, Jisu, Sabong, Ilbanseong, the whole area of Ibanseong), the 119 division is installed more to be operated. However, accessibility is still remaining in low level. Also, in case of 119 safety center of Cheonjeon, the national industrial complex and the general industrial complex are being formed on a large scale. However, analyzing the fire service level in the corresponding area, the districts with more than 8 minutes and less than 20 minutes were existing broadly. In consequence of analyzing the fire service area in Jinju city with the fire-suppression mobilization time as the above, the fire service level is failing to escape largely from the status prior to the urban-rural consolidation compared to what the jurisdictional area was largely expanded by which the administrative districts were integrated by the urban-rural consolidation in locally small-and medium-sized city. Thus, there is a need of a measure for improving this.

Turn signal lamp jacket to prevent accident of bicycles

  • Saxena, Tarika
    • Korean Journal of Artificial Intelligence
    • /
    • v.4 no.1
    • /
    • pp.4-7
    • /
    • 2016
  • These days, citizens have made change of food life to take Western style food and to suffer from diabetes because of excessive nutrition taking, less exercise, stress and other environmental factors. They may suffer from diabetes because of genetic defect, surgery of pancreas, disinfection and medicine and others. One of ten Koreans may have symptom of diabetes to be popular. The diabetes that is a kind of metabolic disease has high blood sugar at disorder of hyper insulinism and/or defect of insulin action. Long time high blood sugar may produce chronic disease of kidney, eyes, nerve, heart and blood vessel and others. The purpose of health care of diabetes patient was to reach target blood sugar by diet, physical exercise and medicine and to prevent and delay complication. Diabetes patient shall control blood sugar to keep healthy. The blood sugar control requires time and effort, and all of the patients are difficult to make effort and to spend time. You can control blood sugar by the application. The application allows patients to control blood sugar and to save time and efforts and to make small sized input and automation of remaining area. The service was limited to blood sugar graph, and user carries smart phone to conduct test and to have difficulty. Further study needs to solve the problems and to investigate blood sugar testing not carrying smart phone and to make application of easy control of blood sugar.

Blue-tooth based blood sugar control application

  • Kelly, Raymond
    • Korean Journal of Artificial Intelligence
    • /
    • v.3 no.1
    • /
    • pp.4-6
    • /
    • 2015
  • These days, citizens have made change of food life to take Western style food and to suffer from diabetes because of excessive nutrition taking, less exercise, stress and other environmental factors. They may suffer from diabetes because of genetic defect, surgery of pancreas, disinfection and medicine and others. One of ten Koreans may have symptom of diabetes to be popular. The diabetes that is a kind of metabolic disease has high blood sugar at disorder of hyper insulinism and/or defect of insulin action. Long time high blood sugar may produce chronic disease of kidney, eyes, nerve, heart and blood vessel and others. The purpose of health care of diabetes patient was to reach target blood sugar by diet, physical exercise and medicine and to prevent and delay complication. Diabetes patient shall control blood sugar to keep healthy. The blood sugar control requires time and effort, and all of the patients are difficult to make effort and to spend time. You can control blood sugar by the application. The application allows patients to control blood sugar and to save time and efforts and to make small sized input and automation of remaining area. The service was limited to blood sugar graph, and user carries smart phone to conduct test and to have difficulty. Further study needs to solve the problems and to investigate blood sugar testing not carrying smart phone and to make application of easy control of blood sugar.

Implementation of Efficient Network Selection System for Mobile IPTV (Mobile IPTV를 위한 효율적 네트워크 선택 시스템 구현)

  • Jeon, Min-Ho;Kang, Chul-Gyu;Oh, Chang-Heon
    • Journal of Advanced Navigation Technology
    • /
    • v.14 no.6
    • /
    • pp.996-1001
    • /
    • 2010
  • In this paper, network selection algorithm for services of mobile IPTV(internet protocol television) and implementation of a hierarchical processing system for reducing overload by terminal with low speed is proposed. This algorithm selects the network according to the following priorities derived from formulas; value that uses remaining bandwidth, network cost, signal strength. If terminal has a low processing power for using selected network and TV service, quality of service declines due to the system overloading. Hence, we implemented system which processes selected network and TV services accomplished by layer divided. Through experiments results, the method of direct user network selection waits for bandwidth assignment. However, on the one hand, that waiting time in exhausted situation will be very long. On the other hand, if we consider the priority plot of used networks, we should select the network with the best state. Therefore, data transmission rate will keep on average and the waiting time will be low.

A Case Study on Implementing Microservice Architecture in Steel Manufacturing MES (철강 제조 MES의 마이크로서비스 아키텍처 적용 구축사례 연구)

  • Hoon Jeong;Jaekyoung Ahn
    • Journal of Information Technology Services
    • /
    • v.23 no.1
    • /
    • pp.37-53
    • /
    • 2024
  • Recently, the application of microservice architecture has been increasing as information systems have shifted to cloud environments. The purpose of this paper was to analyze the case of applying microservice architecture to MES in the manufacturing field, summarize the results of how it was applied in practice, and find out the effects of the application. Based on the improvement project by applying microservice architecture to the existing steel manufacturing MES, 11 principles of microservice application were derived through literature research, and the implementation process and results were summarized according to these principles. In addition, through a comparison of systems in the service industry and the manufacturing industry, we investigated why the application of microservices was more active in the service industry and whether the application in the manufacturing industry can be expected to have the same effect. We also evaluated the results and changes in the overall system after implementation. In particular, we analyzed the SR (Service Request) processing status of users' requests for system changes and operators' requests to see how much the lead time was reduced. The results showed that 8 out of 11 microservice application principles were properly implemented according to the principles, but the remaining 3 were not applicable due to practical difficulties and organizational circumstances. Despite not following all of the principles, the project was able to be implemented without any problems, and the most noticeable change as a result of the microservices architecture was that the lead time was reduced by 9 days compared to the previous system. This proves that it is possible to quickly adapt to customer requirements, and it also proves that the system is more flexible and scalable than the existing monolithic system.

Performance Analysis of Enhanced MAC Protocol to Improve Utilization in Multimedia Service (멀티미디어 서비스 이용률 향상을 위한 진보된 MAC 프로토콜 성능분석)

  • Park, Byung-Joo;Yoo, Hwan-Souk;Kim, Sang-Ha
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.9 no.5
    • /
    • pp.15-21
    • /
    • 2009
  • An Ethernet passive optical network (EPON) is an economical and efficient access network that received significant research attention in recent year. A MAC protocol of the PON, the next generation access network, is based primarily on TDMA (Time Division Multiple Access). In this paper, we addressed the problems of a dynamic bandwidth allocation (DBA) in Fairness and QoS Performance. We augmented the advanced bandwidth allocation algorithms to support efficient resource utilization by reducing the unused remaining bandwidth made by idle state ONUs. Our new proposed advanced bandwidth allocation algorithm can allocate effectively and fairly the bandwidths between end-users.

  • PDF

A Comparative Study on the Process of Hospital Visits according to the Characteristics of the Elderly Visiting to Emergency Medical Centers (권역응급의료센터에 내원한 노인의 제 특성에 따른 내원과정 비교)

  • Yu, Su-Jeong;Gang, In-Sun
    • The Korean Journal of Health Service Management
    • /
    • v.8 no.1
    • /
    • pp.27-39
    • /
    • 2014
  • The purpose of this study is to compare and analyze the process of hospital visits according to the characteristics of the elderly visiting to emergency medical centers. The subject of study was 571 patients over the age of 65 who agreed to participate in the study of emergency medical centers from May 1 to 31, 2010. The frequency, percentage and ${\chi}^2$ test of collected data were conducted with SPSS WIN 12.0. As a result, the frequency of the aged with or without urgency revisiting emergency rooms due to chronic degenerative diseases was high. In addition, there were many cases that the aged living only with a spouse or remaining single. It was obscure to classify them into a urgent or non-emergent group which made it longer time to visit a hospital. It may be necessary that the care for urgent elderly patients considering the characteristics of the family environment functions to care the elderly were weakened.

Residual Life Assessment on Cast Iron Pipes of Water Distribution System (상수도관로중 주철관종의 잔존수명 평가에 관한 연구)

  • Lee, Hyun-Dong;Bae, Chul-Ho;Hong, Seong-Ho;Hwang, Jae-Woon;Kwak, Phill-Jae
    • Journal of Korean Society on Water Environment
    • /
    • v.20 no.3
    • /
    • pp.206-214
    • /
    • 2004
  • Residual wall thicknesses, corrosion rates, and residual life of thirty four samples of cast iron pipes(CIPs) and ductile cast iron pipes(DCIPs) collected from water mains of B city were studied to estimate their remaining service life or optimum time of rehabilitation. The internal maximum corrosion depths of samples measured using a dial gauge after shot blasting were twice higher than the external in most cases. Therefore corrosion of water pipes was much more affected by internal water quality than soil. Residual wall thicknesses of DCIPs were higher than those of CIPs. That reason was thought to be that DCIPs have been protected from internal corrosion by lining cement mortar. Residual life calculated by maximum corrosion rate was ranged up to 44 years with 12.40 years average. Since most CIPs were much deteriorated, rehabilitation plan should be established soon in B city. Residual life of DCIP was 33.52 years average. When cement mortar lining is used up by neutralization of DCIPs. DCIP also should be rehabilitated.

DC Potential Drop Method for Evaluating Material Degradation

  • Seok, Chang-Sung;Bae, Bong-Kook;Koo, Jae-Mean
    • Journal of Mechanical Science and Technology
    • /
    • v.18 no.8
    • /
    • pp.1368-1374
    • /
    • 2004
  • The remaining life estimation for the aged components in power plants as well as chemical plants are very important because mechanical properties of the components are degraded with in-service exposure time in high temperatures. Since it is difficult to take specimens from the operating components to evaluate mechanical properties of components, nondestructive techniques are needed to evaluate the degradation. In this study, test materials with several different degradation levels were prepared by isothermal aging heat treatment at $630^{\circ}C$. The DC potential drop method and destructive methods such as tensile and fracture toughness were used in order to evaluate the degradation of 1Cr-1Mo-0.25V steels. In this result, we can see that tensile strength and fracture toughness can be calculated from resistivity and it is possible to evaluate material degradation using DC potential drop method, non-destructive method.

Evaluation of Material Degradation Using Electrical Resistivity Method (전기비저항법을 이용한 재료열화 평가)

  • Kim, Jeong-Pyo;Bae, Bong-Kook;Kim, Dong-Joong;Seok, Chang-Sung
    • Proceedings of the KSME Conference
    • /
    • 2001.11a
    • /
    • pp.129-136
    • /
    • 2001
  • The remaining life estimation for the aged components in power plants as well as chemical plants are very important beacuse mechanical properties of the components are degraded with time of service exposure in high temperature. Since it is difficult to take specimens from the operating components to evaluate mechanical properties of components, nondestructive techniques are needed to estimate the degradation. In this study, test materials with 4 different degradation levels were prepared by isothermal aging heat treatment at $630^{\circ}C$. And the DC potential drop method and destructive methods such as tensile, $K_{IC}$ and hardness tests were used in order to evaluate the degradation of 1Cr-1Mo-0.25V steels. The objective of this study is to investigate the possibility of the application of DCPD method to estimate the material degradation, and to analyse the relationship between the electrical resistivity and the degree of material degradation.

  • PDF