This study analyzed the present status of services by fire-suppression mobilization time of fire station where is located in Jinju city, by using network analysis of GIS targeting fire station(five 119 safety centers, one 119 division) in Jinju city area. As a result, it was indicated to be 15.9% in the ratio with less than 5 minutes of mobilization time, 34.7% in the ratio with less than 8 minutes, 94% in the ratio with less than 20 minutes out of the whole fire service area in Jinju city. Even districts with more than 20 minutes were analyzed to reach 6%. Especially, to solve vulnerability to approach the fire service in uptown districts(Jinseong, Jisu, Sabong, Ilbanseong, the whole area of Ibanseong), the 119 division is installed more to be operated. However, accessibility is still remaining in low level. Also, in case of 119 safety center of Cheonjeon, the national industrial complex and the general industrial complex are being formed on a large scale. However, analyzing the fire service level in the corresponding area, the districts with more than 8 minutes and less than 20 minutes were existing broadly. In consequence of analyzing the fire service area in Jinju city with the fire-suppression mobilization time as the above, the fire service level is failing to escape largely from the status prior to the urban-rural consolidation compared to what the jurisdictional area was largely expanded by which the administrative districts were integrated by the urban-rural consolidation in locally small-and medium-sized city. Thus, there is a need of a measure for improving this.
Keywords
Fire Station; 119 center; Network analysis; Fire suppression mobilization time; Analysis of fire service area;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Choi, U hyeok, 1999, Study on city fire disaster using gis - using gangnam district as an example -, master's thesis, Seoul National University.
2 Cutter, S. L. and Solecki, W.D, 1989, The national pattern of airborne toxic releases. The professional geographer, Willey Blackwell, Vol.41, pp.149-161.
3 Hewitt. K. and I. Burton, 1971, The hazardousness of a place: a regional ecology of damaging events, University of Toronto.
4 Je, Jin ju, 2008, Study on the fire fighting resources allocation system for the operation efficiency improvement in korea, Ph.D. dissertation , University of Seoul.
5 Jinju fire station, http://jinju.gnfire.go.kr/
6 Jo, Mun seok, 2012, Reliability and validity of performance measurement in the public sector: the case of the national emergency management agency's 'battle against fire', researches in korea's public administration Vol.22, No.4.
7 Jung, Gyu dong, 2012, Study on deriving vulnerable area and its reformation way from accessibility analysis of jurisdiction of daegu city fire & rescue stations, master's thesis, Kyungpook National University.
8 Mark Swanson, 2010, Service area analysis for fire stations in evanston, Illinois, GES 392 GIS II
9 Kain, J ,1968, Housing segregation, Negro employment, and metropolitan decentralization, The quarterly Journal of Economics, JSTOR, Vol.82, NO.2, pp. 175-197.   DOI
10 Kim, Hwng Bae, Kim, Dong Moon, 2002, Study on boundary setting of disaster ares according to explosion of gas & oil station in residental area that apply to gis spatial analysis techniques, Journal of the Korean Society of Civil Engineers, Vol.22, No.5, pp.863-870.
11 Nam, Gwang u, Kim, Jeong geon, 2007, Temporal and spatial distributions of emergency medical services: Busan, Journal of the Korea Association of Geographic Information Studies, Vol.10, No.1.
12 Toronto, ON, Canada, p.154.