• Title/Summary/Keyword: Reflection Coefficient Measurement

Search Result 99, Processing Time 0.021 seconds

A study on a Measurement Method of the Circular-to-Rectangular Waveguide Transition characteristics. (원형-구형 도파관 변환부의 특성 측정 방법 연구)

  • 최병철;신동숙;방재훈;안병철
    • Proceedings of the IEEK Conference
    • /
    • 2002.06a
    • /
    • pp.211-214
    • /
    • 2002
  • In this paper, we present a simple method for characterizing a rectangular waveguide to circular waveguide transition Three standard loads consisting of a short circuit, an offset short circuit 1, and an offset short circuit 2 are sequentially connected to the circular waveguide port and the reflection coefficient at port 1 Is measured for each case. From known reflection coefficients, of standard loads and measured reflection coefficients, the scattering matrix of the transition Is obtained. The proposed method Is verified by the numerical experiment using a commercial software HFSS and by measurments of a actual rectangular-to-circular waveguide transition.

  • PDF

Analysis of the Spectro-ellipsometric Data with Backside Reflection from Semi-transparent Substrate by Using a Rotating Polarizer Ellipsometer (반투명 기층에 의한 후면반사를 고려한 회전검광자 방식의 타원측정 및 분석)

  • Seo, Yeong-Jin;Park, Sang-Uk;Yang, Seong-Mo;Kim, Sang-Youl
    • Korean Journal of Optics and Photonics
    • /
    • v.22 no.4
    • /
    • pp.170-178
    • /
    • 2011
  • The spectroscopic ellipsometric constants are analyzed to determine the thickness and the complex refractive index of a film coated on a semi-transparent substrate, with the reflection from the backside of the substrate properly considered. Expressions representing the effect of the backside reflection on ellipsometric constants are derived using the thickness and the complex refractive index of the substrate. The thickness and the complex refractive of an ITO thin film coated on a glass substrate are obtained by using this method. The results agree quite well with the ones obtained by following the conventional modeling procedure where the backside reflection is neglected during ellipsometric measurement and analysis.

The Design of a Broadband E-plane H Sectoral Horn Phased Array Antenna Using Mutual Coupling (상호 결합을 이용한 광대역 E-면 H 섹터 혼 위상 배열 안테나 설계)

  • Lee, Cheol-Soo;Pack, Jeong-Ki
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.18 no.6 s.121
    • /
    • pp.620-628
    • /
    • 2007
  • An H-sector horn antenna has a constant beam coverage characteristic and it can be useful for application to a wide band phased array antenna system. In this paper, we designed a broadband E-plane H-sector horn phased-array antenna, which has a 3:1 bandwidth and ${\pm}60^{\circ}$ beam steering capability. An H-sector hem antenna was designed to have $30{\sim}50^{\circ}$ half-power beam width in the principal H-plane. The active reflection coefficient including mutual coupling was calculated using a waveguide simulator, and the active reflection characteristic was improved by mutual coupling over wide frequency range. Using these results, an $8{\times}1$ H-sector phased array antenna was fabricated. The measurement results for the half-power beam width in the principal H-plane and the active reflection coefficient showed a good agreement with the simulation results. The peak-value pattern in the steered radiation beams also agreed well with the active element pattern. The measured active reflection coefficients within the beam steering range are mostly less than 0.3 over the 3:1 frequency range.

Measurement of the planar substrate dielectric constant using a microstrip line (마이크로스트립 선로를 이용한 기판의 유전율 측정)

  • Han, Dae-Hyun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.15 no.1
    • /
    • pp.9-15
    • /
    • 2011
  • This paper suggested the fast and easy method of the dielectric constant measurement for planar dielectrics using a microstrip line. The complex permittivity and permeability were presented by the first reflection and transmission coefficient which were derived from the scattering parameters. This method was verified by the measurement of a known planar dielectric using a microstrip line. This method can be applied to the dielectric constant measurement of unknown planar dielectric.

A Coaxial Waveguide-based Spatial Combiner Using Finline-to-Microstrip Transitions (핀라인-마이크로스트립 변환을 이용한 동축선로 도파관 형태의 공간 결합기)

  • Kim, Bo-Ki;Lee, Su-Hyun;Kim, Hyoung-Jong;Shin, Suk-Woo;Kim, Sang-Hoon;Kim, Jae-Duk;Choi, Jin-Joo;Kim, Seon-Joo
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.10 no.5
    • /
    • pp.79-86
    • /
    • 2011
  • In this paper, a S-band coaxial waveguide-based spatial combiner is proposed. The proposed combiner consists of coaxial waveguide, impedance transformer, and finline-to-microstrip transformer. The coaxial waveguide is used as the host of the combining circuits for higher output power and better uniformity by equally distributing the input power to each element. The finline-to-microstrip transformer is designed by using antipodal antenna, and obtained low reflection coefficient by applying the small reflection theorem. The measurement results show the coaxial waveguide combiner has a maximum combining efficiency of 95%.

A Study on AESA Antenna Performance Advancement for Seeker (탐색기용 AESA 안테나 성능 고도화 연구)

  • Youngwan Kim;Jong-Kyun Back;Hee-Duck Chae;Ji-Han Joo
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.23 no.5
    • /
    • pp.103-108
    • /
    • 2023
  • In this paper, a performance enhancement study of an AESA antenna that can be applied to a seeker that serves as the eye of a missile was conducted, and the performance of the antenna was verified through actual measurement. When designing an AESA antenna, the optimization of the active reflection coefficient must be considered during transmission due to the mutual coupling between radiators that inevitably occurs, and the selection of a radiator that can overcome the space limitation of the seeker with a small size/light weight is an important design consideration. Accordingly, optimization in terms of electrical performance and low-profile structure is required through research on array antennas for application to the AESA structure. The radiator designed and measured in this paper was designed as an SFN that can satisfy the low-profile structure while enhancing the performance of a general vivaldi antenna. Through this paper, it was confirmed that SFN has the same broadband characteristics as general vivaldi antennas and has optimized characteristics required for AESA antennas. The structure optimized through simulation confirmed the pattern characteristics and active reflection coefficient characteristics through the fabrication of actual proto-type antennas.

3.5 mm Coaxial One Port Vector Network Analysis Using Time Domain Reflectometry (반사 펄스의 주파수 해석을 이용한 광대역 3.5 mm 동축형 단일 포트 벡터 회로망 분석법)

  • Lee, Dong-Joon;Kwon, Jae-Yong;So, Joon-Ho;Kang, No-Weon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.23 no.8
    • /
    • pp.967-975
    • /
    • 2012
  • This paper presents a method to measure reflection coefficients of microwave devices or antennas based on time domain analysis with sampling oscilloscopes. The reflection coefficients were extracted by the Fourier transformation of echo pulses from devices with respect to the 20 GHz incident pulse signals. The three-error terms, which are commonly used for the correction of a microwave network, were determined using a 3.5 mm calibration kit. In addition, a modified error-correction model associated with a directional coupler for reflection coefficient measurements is introduced. The results were compared with those of measured with a commercial vector network analyzer.

Study on Non-contact Detection of Surface Cracks of the Metals Using an Open-Ended Coaxial Line Sensor at X-band (마이크로파 X-밴드에서의 종단 개방 동축선 센서를 이용한 금속표면균열의 비접촉 검출 연구)

  • Yang, Seung-Hwan;Kim, Dong-Seok;Kim, Ki-Bok;Kim, Jong-Heon;Kang, Jin-Seob
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.32 no.2
    • /
    • pp.192-197
    • /
    • 2012
  • In this paper, a non-contact microwave technique was presented to detect the surface crack of the metals. An open-ended coaxial cable line was used as a sensor at 11 GHz, and the reflection coefficients were measured by scanning along the metal surface including artificial surface cracks. A parameter, the K value which was defined as the difference between maximum and minimum reflection coefficients, was measured and used to estimate the crack depth. A linear relationship between the K value and crack depth was found. This study showed that non-contact detection of the surface cracks of metals is possible using the open-ended coaxial line sensor at X-band.

A Basic Study on the Variation of Temperature Characteristics for Attenuation Coefficient and Sound Velocity in Biological Tissues

  • Park, Heung-Ho
    • Journal of Biomedical Engineering Research
    • /
    • v.14 no.3
    • /
    • pp.273-282
    • /
    • 1993
  • This study is concerned with the temperature dependence characteristics of ultrasound parameters in biological tissues, which are basic on the noninvasive deep body temperature estimation. Used parameters are ultrasonic attenuation coefficient and sound velocity In order to accomplishment our purpose, several signal processing methods were used. Attenua4iorl coefficient was estimated by spectral difference method and sound velocity was estimated by P-P method. And we also examined these methods through a series of IN VITRO experi mentis that used tissue-mimicking phantom samples and biological tissue samples. In order to imitate the biological soft tissue two kinds of phantom samples are used, one is agar phantom sample which is composed of agar, graphite, N-propyl alcohol and distilled water, and the other is fat phantom sample which is composed of pure animal fat. And the ultrasound transmission mode and reflection mode experiments are performed on the pig's spleen, kidney and fat. As a result, it is found that the temperature characteristics are uniform in case of phan- tom samples but not in biological tissues because of complicate wave propagation within them. Consequently, the possibility of temperature measurement using ultrasound on biological tissue is confirmed and its results may contribute to the establishment of reference values of internal temperature measurement of biological tissues.

  • PDF

Long Range UHF RFID Tag with a Rectangular Metallic Cavity Structure

  • Yeo, Jun-Ho
    • Journal of electromagnetic engineering and science
    • /
    • v.10 no.3
    • /
    • pp.121-126
    • /
    • 2010
  • A long range UHF RFID tag with a rectangular metallic cavity structure is proposed for various applications with metallic objects. The proposed tag consists of a rectangular metallic cavity structure and a folded dipole antenna which is located on top of the cavity. The tag is designed for Korean UHF RFID band(910~914 MHz) and the bandwidth, which satisfies the -10 dB input reflection coefficient requirement, is approximately 1.3 %(904~916 MHz). Measurement demonstrates that the proposed tag shows long reading range up to 15 m when it is placed on a metallic plate.