References
- S. Y. Kim, Ellipsometry (Ajou University, Korea, 2000), Chapter 3.
- R. A. Synowicki, "Suppression of backside reflections from transparent substrates," Phys. Stat. Sol. C 5, 1085-1088 (2008). https://doi.org/10.1002/pssc.200777873
- H. Fujiwara, Spectroscopic Ellipsometry: Principles and Applications (John Wiley & Sons, Ibaraki, Japan, 2007), Chapter 5.
- Y. H. Yang and J. R. Abelson, "Spectroscopic ellipsometry of thin films on transparent substrate: a formalism for data interpretation," J. Vac. Sci. Technol. A 13, 1145 (1995). https://doi.org/10.1116/1.579601
- M. Kildemo, R. Ossikovski, and M. Stchakovsky, "Measurement of the absorption edge of thick transparent substrate using the incoherent reflection model and spectroscopic UV-visible-near IR ellipsometry," Thin Solid Films 313-314, 108-113 (1988).
- K. Forcht, A. Gombert, R. Joerger, and M. Kohl, "Incoherent superposition in ellipsometric measurement," Thin Solid Films 302, 43-50 (1997). https://doi.org/10.1016/S0040-6090(96)09555-7
- A. R. Forouhi and I. Bloomer, Handbook of Optical Constants of Solids II, E. D. Palik, ed. (Academic Press, Inc., Toronto, Canada, 1991), Chapter 7.
- S. Y. Kim and K. Vedam, "Proper choice of the error function in modelling spectroscopic ellipsometric data," Appl. Opt. 25, 2013 (1986). https://doi.org/10.1364/AO.25.002013
-
H. J. Kim, H. Y. Pang, and S. Y. Kim, "Determination of the refractive index and the extinction coefficient of
$TiO_{2}$ thin films by using optical methods and of the packing density variation with growth technique," Sae Mulli 37, 45-52 (1997). - R. A. Synowichi, "Spectroscopic ellipsometry characterization of indium tin oxide film microstructure and optical constants," Thin Solid Films 313-314, 394-397 (1998). https://doi.org/10.1016/S0040-6090(97)00853-5
- G. R. Fowles, Introduction to Modern Optics (Dover Publications, New York, USA, 1968), Chapter 6.
- F. Wooten, Optical Properties of Solids (Academic Press, New York, USA, 1972), Chapter 3.
Cited by
- Expressions for Ellipsometric Constants of Samples Covered with Two Thick Incoherent Films vol.24, pp.2, 2013, https://doi.org/10.3807/KJOP.2013.24.2.092
- Precise Measurement of the Ultrasmall Optical Anisotropy of Rubbed Polyimide Using an Improved Reflection Ellipsometer vol.26, pp.4, 2015, https://doi.org/10.3807/KJOP.2015.26.4.195
- Comparison of Misalignment and Retardation Errors of Dual Rotating Quarter-Wave Plates in Muller-Matrix Ellipsometry vol.25, pp.5, 2014, https://doi.org/10.3807/KJOP.2014.25.5.262
- Systematic Error Correction in Dual-Rotating Quarter-Wave Plate Ellipsometry using Overestimated Optimization Method vol.25, pp.1, 2014, https://doi.org/10.3807/KJOP.2014.25.1.029