• 제목/요약/키워드: Rapid detection kit

검색결과 95건 처리시간 0.038초

Development of cellulose nano beads based a rapid detection kit to detect staphylococcal enterotoxin B

  • Kim, Giyoung;Yoo, Jinyoung;Park, Saetbyeol
    • 농업과학연구
    • /
    • 제46권3호
    • /
    • pp.549-557
    • /
    • 2019
  • Staphylococcal enterotoxin is a very common cause of food poisoning. Conventional detection methods for the toxin including enzyme-linked immunosorbent assays (ELISAs), chemiluminescence (ECL), and polymerase chain reaction (PCR) assays require a lot of time, efforts, and expert technicians. Lateral flow strip kits have shown great potential for the rapid detection of foodborne pathogens. The lateral flow strip kit is widely used in clinical settings because it is easy to use, fast, and cost effective. A typical lateral flow strip kit uses colloidal gold to generate a visual signal. However, the lateral flow strip kit based on colloidal gold has limited sensitivity to fulfill food safety regulation requirements. This study was performed to develop a rapid test kit for pathogenic staphylococcal enterotoxin B (SEB) in food samples. The rapid detection kit was fabricated based on a nitrocellulose lateral-flow strip. Cellulose nano beads and SEB antibodies were used as the tag and receptor, respectively, to improve the detection performance. Manually spotted SEB antibody and anti-rabbit antibody on the surface of the nitrocellulose membrane were used as test and control spots, respectively. The feasibility of the rapid test kit to detect SEB in samples was evaluated. The sensitivity of the kit was 10 ng/mL SEB spiked in PBS. Additionally, the rapid test kit could detect 1 ng/mL of SEB in chicken meat extract.

중환자실에 근무하는 의료인의 전비강에서 PBP2a Rapid Kit와 직접 Coagulase 검사를 이용한 Methicillin-resistant Staphylococcus aureus의 검출 (Detection of Methicillin-resistant Staphylococcs aureus from the Anterior Nares of Healthcare Workers in a Intensive Care Unit by Using PBP2a Rapid Kit and Direct Coagulase Test)

  • 홍승복;신경아;손재철;신경섭
    • 대한임상검사과학회지
    • /
    • 제42권2호
    • /
    • pp.86-91
    • /
    • 2010
  • We evaluated the performance of a novel screening test, PBP2a MRSA rapid kit (Dinona Inc., Iksan, Korea), for methicillin-resistant Staphylococcus aureus (MRSA) based on a immunochromatographic assay. The test is able to detect penicillin-binding protein 2a (PBP2a) using the nasal specimens from health care workers. The nasal specimens were obtained from 69 healthcare workers and were incubated in enrichment broth followed eight hours incubatin in BHI with cefoxitin $4{\mu}g/mL$. These broth were tested by PBP2a Rapid Kit. The enrichment broths were also directly tested for tube coagulase using the conventional identification method. 19 of 22 MRSA showed positive results by PBP2a rapid test and direct coagulase test (the sensitivity for detection of MRSA, 86.36%). While, 8 of 47 non-MRSA showed false positive results for the two tests. All of the 8 non-MRSA which showed false positive were co-colonizing isolates with MRCNS and MSSA. In addition, 46 of 49 methicillin-resistant staphylococci (MRS) showed positive results for PBP2a MRSA rapid kit (the sensitivity for detection of MRS, 93.8%), and all of 20 non-MRS showed negative results (specificity, 100%). The combination of PBP2a MRSA rapid kit and direct coagulase test showed the good sensitivity for detection of MRSA from anterior nares but frequently showed false positive results from the co-colonizing carrier with MRCNS and MSSA.

  • PDF

살모넬라 식중독균 신속 검출용 간이 진단키트 (Rapid Detection Kit for Salmonella typhimurium)

  • 김기영;양길모;박샛별;김용훈;이강진;손재용;김혁주;이새롬
    • Journal of Biosystems Engineering
    • /
    • 제36권2호
    • /
    • pp.140-146
    • /
    • 2011
  • This study was performed to develop a rapid test kit for pathogenic Salmonella in various samples. The rapid detection kit has been fabricated based on nitrocellulose lateral-flow strip. Colloidal gold and biotin conjugated Salmonella antibodies were used as a tag and a receptor, respectively. Manually spotted Salmonella antibody and Neutravidin on nitrocellulose membrane were used as test and control lines, respectively. Feasibility of the rapid kit to detect Salmonella typhimurium in samples were evaluated. The intensity of the color of the test line started to increase with the samples in which higher concentration of the cells were contained. The sensitivity of the sensor was $10^6$ cfu/mL Salmonella spiked in PBS. Also, the rapid test kit could detect $10^6$ cfu/mL of Salmonella in chicken meat extract.

황색포도상구균 신속 검출용 간이 진단키트 (Rapid Detection Kit for Staphylococcus aureus)

  • 김기영;박샛별;문지혜;이상대;이새롬;장윤정
    • 농업과학연구
    • /
    • 제40권2호
    • /
    • pp.139-146
    • /
    • 2013
  • This study was performed to develop a rapid test kit for pathogenic Staphylococcus in various samples. The rapid detection kit has been fabricated based on nitrocellulose lateral-flow strip. Colloidal gold and Staphylococcus antibodies were used as a tag and a receptor, respectively. Manually spotted Staphylococcus antibody and anti-mouse antibody on the surface of nitrocellulose membrane were used as test and control lines, respectively. Feasibility of the rapid kit to detect Staphylococcus aureus in samples were evaluated. The intensity of the color of the test line started to increase with the samples in which higher concentration of the cells were contained. The sensitivity of the sensor was $10^6$ cfu/mL Staphylococcus spiked in PBS. Also, the rapid test kit could detect $10^5$ cfu/mL of Staphylococcus in chicken meat extract.

Hepatitis B Surface Antigen을 신속히 검출하기 위한 Immunochromatographic Assay kit의 성능 평가 (The Evaluation of Immunochromatographic Assay kit for Rapid Detection of Hepatitis B Surface Antigen)

  • 신형순;김영봉;신정우;김창규;이왕식;김한겸;신광순
    • 대한바이러스학회지
    • /
    • 제27권2호
    • /
    • pp.137-141
    • /
    • 1997
  • We evaluated Immunochromatographic assay kit to screen HBsAg in human serum. When the reference HBsAg was applyed to ICA, HA and EIA kits, the limit of detection for HBsAg were found out to be 4, 2 and 0.25 ng/ml respectively. But ICA kit required 5 minutes to read the result whereas HA and EIA kit more than one hour. The sensitivity was 97% (29 of 30 samples) and the specificity 100% (45 samples) compared with conventional EIA. The ICA kit needs no instrument or machine to perform the test contrary to the conventional methods. Therefore, this rapid and sensitive ICA kit can be used for HBsAg-screening, especially in the emergency room and in the scene of the accident.

  • PDF

Development of Rapid Immune-gold Strip Kit for On-Site Diagnosis of Tomato spotted wilt virus

  • Yoon, Ju-Yeon;Choi, Gug-Seoun;Cho, In-Sook;Choi, Seung-Kook
    • 식물병연구
    • /
    • 제20권1호
    • /
    • pp.15-20
    • /
    • 2014
  • A rapid, user-friendly and simple immune-chromatographic dipstick kit named 'rapid immune-gold strip' (RIGS) kit was developed in a novel single strip format to detect on-site detection of Tomato spotted wilt virus (TSWV). Immunoglobulin G (IgG) from polyclonal antisera raised in rabbits against TSWV was purified through protein-A affinity chromatography and then the purified TSWV-IgG was conjugated to colloidal gold nano-particles which served as a test line on nitrocellulose membrane. Protein A that non-specifically binds to TSWV antibody was used as a control line on the same strip. The diagnosis process with the TSWV-RIGS involves simply grinding the suspect plant sample in a bag that contains the extraction buffer and inserting the strip the bag. Results can be seen in 2-5 minutes. The flow of the complexes of gold particles coated with TSWV-IgG and a crude sap from TSWV-infected pepper, tobacco and tomato plants resulted in intensive color formed on the test lines proportional to the concentrations of TSWV. The RIGS-TSWV kit did not show any cross-reactions against other tomato-infecting viruses unrelated to TSWV. These results indicate that the TSWV-RIGS kit is highly sensitive and is not required for laboratory training and experience prior to testing. The TSWV-RIGS kit is suitable for on-site detection of suspect TSWV-infected plants as well as for laboratory diagnosis.

생물학작용제 검출 키트 개발 및 성능시험 연구 (Development and Validation Study of Biological Agent Detection Kit)

  • 조혜은
    • 한국군사과학기술학회지
    • /
    • 제22권4호
    • /
    • pp.575-580
    • /
    • 2019
  • In biological warfare, it is important to identify biological agents for proper treatment. We focused on developing a real-time RT-PCR kit that can detect multiple species of biological agents. AccuPower(R) Biothreat Real-Time RT-PCR Kit(v3.0) could detect Bacillus anthracis, Yersinia pestis, Vibrio cholerae, Francisella tularensis, Salmonella typhi, Rickettsia prowazekii, Variola virus, Hantaan virus, Yellow fever virus, Brucella spp., Shigella dysenteriae in a single reaction. The results showed that the kit was verified to be able to detect at least 0.005 ng of nucleotide and 10,000 CFU/ml of bacteria. Therefore, the kit is expected to be used as a rapid and sensitive detection kit for 11 species of biological agents within 2 hours.

Development of Rapid Diagnostic Technology for Pig Disease (2) - Rapid detection of PPE in the pig feces -

  • Kim, Hyuck-Joo;Hong, Jong-Tae;Yu, Byeong-Kee;Kim, Giyoung;Kim, Suk
    • Journal of Biosystems Engineering
    • /
    • 제38권2호
    • /
    • pp.121-128
    • /
    • 2013
  • Purpose: Porcine proliferative enteropathy (PPE), caused by the obligate intracellular bacterium Lawsonia intracellularis, is a widely distributed disease throughout the world causing substantial economic loss. In order to diagnose PPE rapidly, the rapid kit was developed and tested. Methods: In this study, a rapid kit was developed to screen the PPE rapidly at the pig farm. Also, occult blood test with fecal occult blood (FOB) kit was done for detecting the blood in pig feces which might be the evident of hemorrhagic PPE. For developing the kit, we tested fecal samples of PPE infected pigs diagnosed by polymerase chain reaction (PCR) method. Results: With the developed rapid kit, Lawsonia intracellularis was detected in high density emulsion of ileum. On the other hand, the test result of detecting Lawsonia in feces showed too high non-specific response. In addition, nevertheless the FOB test result showed that blood evident could be founded in pig feces, the diagnosing result was not fit to PCR test result, which shows blood in pig feces could be from not only hemorrhagic PPE but also many reasons. Conclusions: To deal with the PPE effectively, it will be better for farmers to screen the PPE in earlier stage with easy and rapid diagnosing tool on farm. This study found out that the rapid kit could detect the Lawsonia intracellularis and hemoglobin in pig feces. However, the non-specific response to negative samples of PPE was too high to use at a pig farm. Further research is needed for lowering the non-specific response with the rapid kit.

Development of a ladder-shape melting temperature isothermal amplification (LMTIA) assay for detection of African swine fever virus (ASFV)

  • Wang, Yongzhen;Wang, Borui;Xu, Dandan;Zhang, Meng;Zhang, Xiaohua;Wang, Deguo
    • Journal of Veterinary Science
    • /
    • 제23권4호
    • /
    • pp.51.1-51.10
    • /
    • 2022
  • Background: Due to the unavailability of an effective vaccine or antiviral drug against the African swine fever virus (ASFV), rapid diagnosis methods are needed to prevent highly contagious African swine fever. Objectives: The objective of this study was to establish the ladder-shape melting temperature isothermal amplification (LMTIA) assay for the detection of ASFV. Methods: LMTIA primers were designed with the p72 gene of ASFV as the target, and plasmid pUC57 was used to clone the gene. The LMTIA reaction system was optimized with the plasmid as the positive control, and the performance of the LMTIA assay was compared with that of the commercial real-time polymerase chain reaction (PCR) kit in terms of sensitivity and detection rate using 200 serum samples. Results: Our results showed that the LMTIA assay could detect the 104 dilution of DNA extracted from the positive reference serum sample, which was the same as that of the commercial real-time PCR kit. The coincidence rate between the two assays was 100%. Conclusions: The LMTIA assay had high sensitivity, good detection, and simple operation. Thus, it is suitable for facilitating preliminary and cost-effective surveillance for the prevention and control of ASFV.

면역크로마토그래피를 이용한 E. coli O157: H7 신속검출 키트의 유효성 평가 (Evaluation of the Efficiency of E. coli O157: H7 Rapid Detection Kit using Immunochromatography)

  • 곽효선;이동하;문희숙;박종석;우건조;김창민
    • 한국식품위생안전성학회지
    • /
    • 제18권3호
    • /
    • pp.118-124
    • /
    • 2003
  • 식품으로부터 다양한 병원 미생물을 신속 검출하기 위하여 다양한 검출 원리를 이요한 키트들이 개발 시판되고 있다. 검사키트는 신속, 정확하고 간단하게 사용할 수 있으므로 검사기관이나 실험실 뿐 아니라 식품회사에서 QC 또는 QA를 수행하기 위하여 사용이 증가되고 있는 추세이다. 이에 본 연구에서는 E. coli 0157:H7의 단클론항체를 이용하여 면역크로마토글래피법에 의해 개발된 E. coli 0157:H7 검출 키트(Donga Co, Korea, D-kit)에 대한 검출감도 및 특이성을 확인하고 식품 시료에 적용 가능성을 평가하였다. 면역크로마토그래피법에 의하여 개발 시판되고 있는 Reveal E. coli 0157:H7 kit (Neogen Co., USA. R-kit)와 VIP EHEC kit(Biocontro Inc., USA. V-kit)를 비교 키트로 사용하였다. E. coli 0157:H7 표준균주를 사용하여 실시한 검출감도 확인시험 결과 R-kit 및 D-kit는 104/m/의 농도에서 양성으로 확인되었고 $10^3$/ml에서도 약한 양성 반응을 보였으나, V-lit는 $10^5$/ml농도로 검출감도가 낮았다. 또한, 배양액을 가열하여 kit에 적용하는 것이 가열하지 않은 경우보다 검출감도를 높일 수 있었다. E. coli 0157:H7 분리 22주, verotoxin 생성 E. coli 7주 E. coli 분리주 40주 중 3주를 제외한 모든 균에서 음성의 결과를 보여 특이성을 확인하였다. 세 키트에 위양성 반응을 보인 것은 E. coli 0157:H19, E. coli 0148:H18 및 Salmonella gallinarium으로 이들 혈청형과 0157:H7 사이에는 유사한 혈청학적 특성이 존재하는 것으로 추정되었다. 이상의 실험결과로 D-kit는 E. coli 0157:H7을 검출하는데 감도 및 특이성 면에서 기존 키트인 R-kit 및 V-kit와 같이 이용한 것으로 확인되었다.