• Title/Summary/Keyword: Rapid detection kit

Search Result 95, Processing Time 0.034 seconds

Norovirus Targeted Bioreceptor Screening Method based on Lateral Flow Immunoassay (LFIA) (노로바이러스 검출을 위한 측면유동면역분석법 기반의 바이오리셉터 선별기법 개발)

  • Huisoo, Jang;Hyeonji, Cho;Tae-Joon, Jeon;Sun Min, Kim
    • Journal of the Korean Society of Visualization
    • /
    • v.20 no.3
    • /
    • pp.136-145
    • /
    • 2022
  • Later flow immunoassay (LFIA) is a protein analytical method based on immunoreaction. On the LFIA based protein analytical method, bioreceptor molecule plays a key role, and so a system that evaluates and manages the binding affinity of bioreceptor is needed to secure detection reliability. In this study, Lateral Flow Immunoassay based rapid Bioreceptor Screening Method (rBSM) is presented that provide a simple and quick evaluating method for the binding affinity to the target protein of the antibody as model bioreceptor. To verify this evaluation method, Virus-like particles (VLP) and anti-VLP antibodies are selected as a model norovirus, which is target protein, and the candidate bioreceptors respectively. Among the 5 different candidate antibodies, appropriate antibody could be sorted out within 30 minutes through rBSM. In addition, selected antibodies were applied to two representative LFIA based techniques, sandwich assay and competitive assay. Among these methods, sandwich assay showed more effective VLP detection method. Through applying selected antibodies and techniques to the commercialized mass production lines, an VLP detecting LFIA kit was developed with a detection limit of 1012 copies/g of VLPs in real samples. Since this proposed method in this study could be easily transformable into other combinations with bioreceptors, it is expected that this technique would be applied to LFIA kit development system and bioreceptor quality management.

Intrusion Detection Using Log Server and Support Vector Machines

  • Donghai Guan;Donggyu Yeo;Lee, Juwan;Dukwhan Oh
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2003.10a
    • /
    • pp.682-684
    • /
    • 2003
  • With the explosive rapid expansion of computer using during the past few years, security has become a crucial issue for modem computer systems. Today, there are many intrusion detection systems (IDS) on the Internet. A variety of intrusion detection techniques and tools exist in the computer security community such as enterprise security management system (ESM) and system integrity checking tools. However, there is a potential problem involved with intrusion detection systems that are installed locally on the machines to be monitored. If the system being monitored is compromised, it is quite likely that the intruder will after the system logs and the intrusion logs while the intrusion remains undetected. In this project KIT-I, we adopt remote logging server (RLS) mechanism, which is used to backup the log files to the server. Taking into account security, we make use of the function of SSL of Java and certificate authority (CA) based key management. Furthermore, Support Vector Machine (SVM) is applied in our project to detect the intrusion activities.

  • PDF

Fusion Analytical Sensitivity of Rapid Influenza Antigen Limit of Detection Tests for Human Influenza virus (인플루엔자 바이러스에 대한 신속 항원 검출 검사 검출한계의 융합적 분석)

  • Song, Chang-Sub;Sung, Hyun-Ho;Kim, Jung-Hyun;Kim, Dae-Eun;Park, Chang-Eun;Yoon, Joong-Soo
    • Journal of the Korea Convergence Society
    • /
    • v.9 no.3
    • /
    • pp.165-171
    • /
    • 2018
  • In this study, to analyze the detection of limit for sensitivity of the influenza rapid antigen test kit, the positive detection of limits were analyzed by serial dilution of influenza virus A and B type for five influenza rapid antigen test kits in Korea. As a result of analysis, visual measurement of type A were up to 1:8192 for the Wellsbio product and up to 1:4096 for the II product, up to 1:512 for the I and III products, and only 1:128 for the IV product, and type B were positive for up to 1:8192 for the Wellsbio product, up to 1: 4096 for the II product and up to 1:1024 for the I, III and IV products. For instrument readings with the same specimen, both A and B types were found to be positive for up to 1:8192 for the Wellsbio product, up to 1: 4096 for the II product, and up to 1:2048 for the I product. The sensitivity of the rapid antigen test for influenza differs greatly depending on the sampling area of the patient, infection period, specimen volume, etc. Therefore, it is necessary to observe exactly the collection timing and method of the specimen. And it is necessary further study to improve the sensitivity for influenza rapid antigen test.

Comparison of Upgraded Methods for Detecting Pathogenic Escherichia coli in Foods Using Centrifugation or Filtration

  • Choi, Yukyung;Lee, Heeyoung;Lee, Soomin;Kim, Sejeong;Lee, Jeeyeon;Ha, Jimyeong;Oh, Hyemin;Yoon, Yohan
    • Food Science of Animal Resources
    • /
    • v.37 no.6
    • /
    • pp.799-803
    • /
    • 2017
  • In the present study, centrifugation and filtration pretreatments were evaluated to decrease sample preparation time and to improve the sensitivity and specificity of multiplex polymerase chain reaction (PCR) for the detection of low levels of pathogenic Escherichia coli in various foods. Pathogenic E. coli (E. coli NCCP11142, E. coli NCCP14037, E. coli NCCP 14038, E. coli NCCP14039, and E. coli NCCP15661) was inoculated into pork, beef, and baby leafy vegetables at 1, 2, and 3 Log CFU/g. The samples were shaken 30 times (control), then centrifuged or filtered. DNA extracts from the samples were subjected to PCR using the $Powerchek^{TM}$ Diarrheal E. coli 8-plex Detection Kit. In the pork samples, no E. coli was detected in the control samples, while E. coli were detected in 100% of 3-Log CFU/g inoculated and centrifuged samples, and in 100% of 2 and 3-Log CFU/g inoculated, and filtered samples. In the beef samples, all control samples appeared to be E. coli-negative, while E. coli was detected in 50-75% of centrifuged samples, regardless of inoculated level, and in 100% of 2 and 3-Log CFU/g inoculated, and filtered samples. In baby leafy vegetables, E. coli were not detected in 25-50% of the control samples, while E. coli were detected in 0-25% of the centrifuged samples, and 75-100% of the filtered samples, depending on the inoculum amount. In conclusion, filtration pretreatment can be used to minimize sample preparation time, and improve the sensitivity and specificity of rapid detection of pathogenic E. coli in various foods.

A Simple, Rapid, and Automatic Centrifugal Microfluidic System for Influenza A H1N1 Viral RNA Purification

  • Park, Byung Hyun;Jung, Jae Hwan;Oh, Seung Jun;Seo, Tae Seok
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.277.1-277.1
    • /
    • 2013
  • Molecular diagnostics consists of three processes, which are a sample pretreatment, a nucleic acid amplification, and an amplicon detection. Among three components, sample pretreatment is an important process in that it can increase the limit of detection by purifying nucleic acid in biological sample from contaminants that may interfere with the downstream genetic analysis such as nucleic acid amplification and detection. To achieve point-of-care virus detection system, the sample pretreatment process needs to be simple, rapid, and automatic. However, the commercial RNA extraction kits such as Rneasy (Qiagen) or MagnaPure (Roche) kit are highly labor-intensive and time-consuming due to numerous manual steps, and so it is not adequate for the on-site sample preparation. Herein, we have developed a rotary microfluidic system to extract and purify the RNA without necessity of external mechanical syringe pumps to allow flow control using microfluidic technology. We designed three reservoirs for sample, washing buffer, and elution buffer which were connected with different dimensional microfluidic channels. By controlling RPM, we could dispense a RNA sample solution, a washing buffer, and an elution buffer successively, so that the RNA was captured in the sol-gel solid phase, purified, and eluted in the downstream. Such a novel rotary sample preparation system eliminates some complicated hardwares and human intervention providing the opportunity to construct a fully integrated genetic analysis microsystem.

  • PDF

Comparison of the Performance of MiSeq and HiSeq 2500 in a Microbiome Study

  • Na, Hee Sam;Yu, Yeuni;Kim, Si Yeong;Lee, Jae-Hyung;Chung, Jin
    • Microbiology and Biotechnology Letters
    • /
    • v.48 no.4
    • /
    • pp.574-581
    • /
    • 2020
  • Next generation sequencing is commonly used to characterize the microbiome structure. MiSeq is commonly used to analyze the microbiome due to its relatively long read length. However, recently, Illumina introduced the 250x2 chip for HiSeq 2500. The purpose of this study was to compare the performance of MiSeq and HiSeq in the context of oral microbiome samples. The MiSeq Reagent Kit V3 and the HiSeq Rapid SBS Kit V2 were used for MiSeq and HiSeq 2500 analyses, respectively. Total read count, read quality score, relative bacterial abundance, community diversity, and relative abundance correlation were analyzed. HiSeq produced significantly more read sequences and assigned taxa compared to MiSeq. Conversely, community diversity was similar in the context of MiSeq and HiSeq. However, depending on the relative abundance, the correlation between the two platforms differed. The correlation between HiSeq and MiSeq sequencing data for highly abundant taxa (> 2%), low abundant taxa (2-0.2%), and rare taxa (0.2% >) was 0.994, 0.860, and 0.416, respectively. Therefore, HiSeq 2500 may also be compatible for microbiome studies. Importantly, the HiSeq platform may allow a high-resolution massive parallel sequencing for the detection of rare taxa.

A Simultaneous Analytical Method for Duplex Identification of Porcine and Horse in the Meat Products by EvaGreen based Real-time PCR

  • Sakalar, Ergun;Ergun, Seyma Ozcirak;Akar, Emine
    • Food Science of Animal Resources
    • /
    • v.35 no.3
    • /
    • pp.382-388
    • /
    • 2015
  • A duplex real-time polymerase chain reaction (PCR) based assay for the detection of porcine and horse meat in sausages was designed by using EvaGreen fluorescent dye. Primers were selected from mitochondrial 12S rRNA and 16S rRNA genes which are powerful regions for identification of horse and porcine meat. DNA from reference samples and industrial products was successfully extracted using the GIDAGEN® Multi-Fast DNA Isolation Kit. Genomes were identified based on their specific melting peaks (Mp) which are 82.5℃ and 78℃ for horse and porcine, respectively. The assay used in this study allowed the detection of as little as 0.0001% level of horse meat and 0.001% level of porcine meat in the experimental admixtures. These findings indicate that EvaGreen based duplex realtime PCR is a potentially sensitive, reliable, rapid and accurate assay for the detection of meat species adulterated with porcine and horse meats.

Development and Evaluation of an Immunochromatographic Assay for Screening Listeria spp. in Pork and Milk

  • Kim, Seong-Hee;Kim, Jin-Young;Han, Woong;Jung, Byeong-Yeal;Chuong, Pham-Due;Joo, Hae-Jin;Ba, Hoa-Van;Son, Won-Geun;Jee, Young-Heun;Yoon, Byoung-Su;Lee, Yong-Soon;Lim, Yoon-Kyu
    • Food Science and Biotechnology
    • /
    • v.16 no.4
    • /
    • pp.515-519
    • /
    • 2007
  • Rapid immunochromatographic assay (ICA) kits were developed using flagella-specific monoclonal antibodies (MAbs) and rabbit polyclonal antibodies for screening Listeria spp. in food. The establishment of different formats, MAb 2B1 as capture antibody and MAb 7A3 or rabbit polyclonal antibodies as detector antibody, was compared. The 2 formats of the ICA kit were shown to have specific reactions with Listeria and no cross-reactivity with any of the non-Listeria including Escherichia coli O157:H7 and Salmonella enteritidis. The detection limits of the ICA kit using the combination of gold-labeled MAb 7A3 and MAb 2B1 showed $1{\times}10^5$ and $1{\times}10^6\;CFU/0.1\;mL$ at 22 and $30^{\circ}C$, respectively. The other format of the ICA kit using the combination of gold-labeled rabbit polyclonal antibodies and MAb 2B1 showed $1{\times}10^6\;CFU/0.1\;mL$ at $22^{\circ}C$ but weak signal at 30 culture. The format utilizing MAb was more sensitive than the one using polyclonal antibodies for capture antibody. Samples contaminated with L. monocytogenes 4b culture (9-10, 5-6, and 1-2 CFU/mL) on pork and pasteurized milk were confirmed as positive results. Current data suggests that this ICA kit is a rapid, simple and effective tool to screen for Listeria spp. in food.

Evaluation of a rapid diagnostic kit "BIOLINE RSVTM" for the detection of respiratory syncytial virus (Respiratory Syncytial Virus 감염의 조기 진단 kit "바이오라인 알에스브이TM"의 평가)

  • Kim, So-Hee;Sung, Ji-Yeon;Yang, Mi-Ae;Eun, Byung-Wook;Lee, Jin-A;Choi, Eun-Hwa;Lee, Hoan-Jong
    • Pediatric Infection and Vaccine
    • /
    • v.14 no.1
    • /
    • pp.91-96
    • /
    • 2007
  • Purpose : This study was performed to evaluate a new rapid diagnostic kit (BIOLINE $RSV^{TM}$; Standard Diagnostics Inc., Yongin, Korea), a lateral-flow immunoassay, in the detection of respiratory syncytial virus (RSV) from the nasopharyngeal aspirates (NPA) of children with lower respiratory tract infections (LRTIs) in comparison with other diagnostic methods. Methods : Three hundred and nineteen NPAs were selected from a large pool of NPAs that had been obtained from children with LRTIs. All specimens had already been tested for RSV by culture and immunofluorescent (IF) test, and had been kept frozen. Tests with BIOLINE $RSV^{TM}$ were performed at least twice. All who conducted the experiments or interpreted the test results were blinded to the results of both culture and IF tests. Results : One hundred seven (97.3%) of 110 specimens that were positive for RSV by both culture and IF test, 29 (87.9%) of 33 that were positive by IF test only, 20 (76.9%) of 26 that were positive by culture only, and 140 (93.3%) of 150 that were negative by both methods were negative for RSV by BIOLINE $RSV^{TM}$. By combining the above results, the following 5 diagnostic values of BIOLINE $RSV^{TM}$ were determined in comparison with viral culture or IF test; sensitivity, 92.3% (156/169, 95% confidence interval [CI], 87.1-97.5%); specificity, 93.3% (140/150, 95% CI, 88.4-98.2%); positive predictive value, 94.0% (156/166, 95% CI, 89.5-98.5%); negative predictive value, 91.5% (140/143, 95% CI, 86.0-97.0%); and agreement, 95.9% (306/319, 95% CI, 92.1-99.7%), respectively. Conclusion : This study revealed that BIOLINE $RSV^{TM}$ demonstrated good sensitivity and specificity for the detection of RSV antigen from NPAs of children with LRTIs. Because of simple methods and quick results, this test may be useful for the diagnosis of RSV infection during the epidemic periods.

  • PDF

Development of a One-Step PCR Assay with Nine Primer Pairs for the Detection of Five Diarrheagenic Escherichia coli Types

  • Oh, Kyung-Hwan;Kim, Soo-Bok;Park, Mi-Sun;Cho, Seung-Hak
    • Journal of Microbiology and Biotechnology
    • /
    • v.24 no.6
    • /
    • pp.862-868
    • /
    • 2014
  • Certain Escherichia coli (E. coli) strains have the ability to cause diarrheal disease. Five types of diarrheagenic E. coli have been identified, including EHEC, ETEC, EPEC, EAEC, and EIEC. To detect these five diarrheagenic types rapidly, we developed a one-step multiplex PCR (MP-PCR) assay using nine primer pairs to amplify nine virulence genes specific to the different virotypes, with each group being represented (i.e., stx1 and stx2 for EHEC, lt, sth, and stp for ETEC, eaeA and bfpA for EPEC, aggR for EAEC, and ipaH for EIEC). The PCR primers were constructed using MultAlin. The sensitivity and specificity of the constructed multiplex PCR primers were measured using DNA isolated from diarrheagenic E. coli strains representing each group. The limits of detection were as follows: $5{\times}10^1CFU/ml$ for EHEC, $5{\times}10^3CFU/ml$ for ETEC expressing lt and sth, $5{\times}10^4CFU/ml$ for ETEC expressing stp, $5{\times}10^2CFU/ml$ for EPEC, $5{\times}10^4CFU/ml$ for EAEC, and $5{\times}10^2CFU/ml$ for EIEC. To confirm the specificity, C. jejuni, C. perfringens, S. Typhimurium, V. parahaemolyticus, L. monocytogenes, Y. enterocolitica, B. cereus, and S. aureus were used as negative controls, and no amplification was obtained for these. Moreover, this kit was validated using 100 fecal samples from patients with diarrhea and 150 diarrheagenic E. coli strains isolated in Korea. In conclusion, the multiplex PCR assay developed in this study is very useful for the rapid and specific detection of five diarrheagenic E. coli types. This single-step assay will be useful as a rapid and economical method, as it reduces the cost and time required for the identification of diarrheagenic E. coli.