• Title/Summary/Keyword: Rapid detection kit

Search Result 95, Processing Time 0.03 seconds

Development of cellulose nano beads based a rapid detection kit to detect staphylococcal enterotoxin B

  • Kim, Giyoung;Yoo, Jinyoung;Park, Saetbyeol
    • Korean Journal of Agricultural Science
    • /
    • v.46 no.3
    • /
    • pp.549-557
    • /
    • 2019
  • Staphylococcal enterotoxin is a very common cause of food poisoning. Conventional detection methods for the toxin including enzyme-linked immunosorbent assays (ELISAs), chemiluminescence (ECL), and polymerase chain reaction (PCR) assays require a lot of time, efforts, and expert technicians. Lateral flow strip kits have shown great potential for the rapid detection of foodborne pathogens. The lateral flow strip kit is widely used in clinical settings because it is easy to use, fast, and cost effective. A typical lateral flow strip kit uses colloidal gold to generate a visual signal. However, the lateral flow strip kit based on colloidal gold has limited sensitivity to fulfill food safety regulation requirements. This study was performed to develop a rapid test kit for pathogenic staphylococcal enterotoxin B (SEB) in food samples. The rapid detection kit was fabricated based on a nitrocellulose lateral-flow strip. Cellulose nano beads and SEB antibodies were used as the tag and receptor, respectively, to improve the detection performance. Manually spotted SEB antibody and anti-rabbit antibody on the surface of the nitrocellulose membrane were used as test and control spots, respectively. The feasibility of the rapid test kit to detect SEB in samples was evaluated. The sensitivity of the kit was 10 ng/mL SEB spiked in PBS. Additionally, the rapid test kit could detect 1 ng/mL of SEB in chicken meat extract.

Detection of Methicillin-resistant Staphylococcs aureus from the Anterior Nares of Healthcare Workers in a Intensive Care Unit by Using PBP2a Rapid Kit and Direct Coagulase Test (중환자실에 근무하는 의료인의 전비강에서 PBP2a Rapid Kit와 직접 Coagulase 검사를 이용한 Methicillin-resistant Staphylococcus aureus의 검출)

  • Hong, Seung-Bok;Shin, Kyung-A;Son, Jae-Cheol;Shin, Seob-Kyeong
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.42 no.2
    • /
    • pp.86-91
    • /
    • 2010
  • We evaluated the performance of a novel screening test, PBP2a MRSA rapid kit (Dinona Inc., Iksan, Korea), for methicillin-resistant Staphylococcus aureus (MRSA) based on a immunochromatographic assay. The test is able to detect penicillin-binding protein 2a (PBP2a) using the nasal specimens from health care workers. The nasal specimens were obtained from 69 healthcare workers and were incubated in enrichment broth followed eight hours incubatin in BHI with cefoxitin $4{\mu}g/mL$. These broth were tested by PBP2a Rapid Kit. The enrichment broths were also directly tested for tube coagulase using the conventional identification method. 19 of 22 MRSA showed positive results by PBP2a rapid test and direct coagulase test (the sensitivity for detection of MRSA, 86.36%). While, 8 of 47 non-MRSA showed false positive results for the two tests. All of the 8 non-MRSA which showed false positive were co-colonizing isolates with MRCNS and MSSA. In addition, 46 of 49 methicillin-resistant staphylococci (MRS) showed positive results for PBP2a MRSA rapid kit (the sensitivity for detection of MRS, 93.8%), and all of 20 non-MRS showed negative results (specificity, 100%). The combination of PBP2a MRSA rapid kit and direct coagulase test showed the good sensitivity for detection of MRSA from anterior nares but frequently showed false positive results from the co-colonizing carrier with MRCNS and MSSA.

  • PDF

Rapid Detection Kit for Salmonella typhimurium (살모넬라 식중독균 신속 검출용 간이 진단키트)

  • Kim, Gi-Young;Yang, Gil-Mo;Park, Saet-Byeol;Kim, Yung-Hwun;Lee, Kang-Jin;Son, Jae-Yong;Kim, Hyuck-Joo;Lee, Sae-Rom
    • Journal of Biosystems Engineering
    • /
    • v.36 no.2
    • /
    • pp.140-146
    • /
    • 2011
  • This study was performed to develop a rapid test kit for pathogenic Salmonella in various samples. The rapid detection kit has been fabricated based on nitrocellulose lateral-flow strip. Colloidal gold and biotin conjugated Salmonella antibodies were used as a tag and a receptor, respectively. Manually spotted Salmonella antibody and Neutravidin on nitrocellulose membrane were used as test and control lines, respectively. Feasibility of the rapid kit to detect Salmonella typhimurium in samples were evaluated. The intensity of the color of the test line started to increase with the samples in which higher concentration of the cells were contained. The sensitivity of the sensor was $10^6$ cfu/mL Salmonella spiked in PBS. Also, the rapid test kit could detect $10^6$ cfu/mL of Salmonella in chicken meat extract.

Rapid Detection Kit for Staphylococcus aureus (황색포도상구균 신속 검출용 간이 진단키트)

  • Kim, Gi-Young;Park, Saet-Byeol;Moon, Ji-Hea;Lee, Sang-Dae;Lee, Sea-Rom;Jang, Youn-Jung
    • Korean Journal of Agricultural Science
    • /
    • v.40 no.2
    • /
    • pp.139-146
    • /
    • 2013
  • This study was performed to develop a rapid test kit for pathogenic Staphylococcus in various samples. The rapid detection kit has been fabricated based on nitrocellulose lateral-flow strip. Colloidal gold and Staphylococcus antibodies were used as a tag and a receptor, respectively. Manually spotted Staphylococcus antibody and anti-mouse antibody on the surface of nitrocellulose membrane were used as test and control lines, respectively. Feasibility of the rapid kit to detect Staphylococcus aureus in samples were evaluated. The intensity of the color of the test line started to increase with the samples in which higher concentration of the cells were contained. The sensitivity of the sensor was $10^6$ cfu/mL Staphylococcus spiked in PBS. Also, the rapid test kit could detect $10^5$ cfu/mL of Staphylococcus in chicken meat extract.

The Evaluation of Immunochromatographic Assay kit for Rapid Detection of Hepatitis B Surface Antigen (Hepatitis B Surface Antigen을 신속히 검출하기 위한 Immunochromatographic Assay kit의 성능 평가)

  • Shin, Hyeong-Soon;Kim, Young-Bong;Shin, Jung-Woo;Kim, Chang-Kyu;Lee, Wang-Sik;Kim, Han-Kyeom;Shin, Kwang-Soon
    • The Journal of Korean Society of Virology
    • /
    • v.27 no.2
    • /
    • pp.137-141
    • /
    • 1997
  • We evaluated Immunochromatographic assay kit to screen HBsAg in human serum. When the reference HBsAg was applyed to ICA, HA and EIA kits, the limit of detection for HBsAg were found out to be 4, 2 and 0.25 ng/ml respectively. But ICA kit required 5 minutes to read the result whereas HA and EIA kit more than one hour. The sensitivity was 97% (29 of 30 samples) and the specificity 100% (45 samples) compared with conventional EIA. The ICA kit needs no instrument or machine to perform the test contrary to the conventional methods. Therefore, this rapid and sensitive ICA kit can be used for HBsAg-screening, especially in the emergency room and in the scene of the accident.

  • PDF

Development of Rapid Immune-gold Strip Kit for On-Site Diagnosis of Tomato spotted wilt virus

  • Yoon, Ju-Yeon;Choi, Gug-Seoun;Cho, In-Sook;Choi, Seung-Kook
    • Research in Plant Disease
    • /
    • v.20 no.1
    • /
    • pp.15-20
    • /
    • 2014
  • A rapid, user-friendly and simple immune-chromatographic dipstick kit named 'rapid immune-gold strip' (RIGS) kit was developed in a novel single strip format to detect on-site detection of Tomato spotted wilt virus (TSWV). Immunoglobulin G (IgG) from polyclonal antisera raised in rabbits against TSWV was purified through protein-A affinity chromatography and then the purified TSWV-IgG was conjugated to colloidal gold nano-particles which served as a test line on nitrocellulose membrane. Protein A that non-specifically binds to TSWV antibody was used as a control line on the same strip. The diagnosis process with the TSWV-RIGS involves simply grinding the suspect plant sample in a bag that contains the extraction buffer and inserting the strip the bag. Results can be seen in 2-5 minutes. The flow of the complexes of gold particles coated with TSWV-IgG and a crude sap from TSWV-infected pepper, tobacco and tomato plants resulted in intensive color formed on the test lines proportional to the concentrations of TSWV. The RIGS-TSWV kit did not show any cross-reactions against other tomato-infecting viruses unrelated to TSWV. These results indicate that the TSWV-RIGS kit is highly sensitive and is not required for laboratory training and experience prior to testing. The TSWV-RIGS kit is suitable for on-site detection of suspect TSWV-infected plants as well as for laboratory diagnosis.

Development and Validation Study of Biological Agent Detection Kit (생물학작용제 검출 키트 개발 및 성능시험 연구)

  • Joe, Hae Eun
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.22 no.4
    • /
    • pp.575-580
    • /
    • 2019
  • In biological warfare, it is important to identify biological agents for proper treatment. We focused on developing a real-time RT-PCR kit that can detect multiple species of biological agents. AccuPower(R) Biothreat Real-Time RT-PCR Kit(v3.0) could detect Bacillus anthracis, Yersinia pestis, Vibrio cholerae, Francisella tularensis, Salmonella typhi, Rickettsia prowazekii, Variola virus, Hantaan virus, Yellow fever virus, Brucella spp., Shigella dysenteriae in a single reaction. The results showed that the kit was verified to be able to detect at least 0.005 ng of nucleotide and 10,000 CFU/ml of bacteria. Therefore, the kit is expected to be used as a rapid and sensitive detection kit for 11 species of biological agents within 2 hours.

Development of Rapid Diagnostic Technology for Pig Disease (2) - Rapid detection of PPE in the pig feces -

  • Kim, Hyuck-Joo;Hong, Jong-Tae;Yu, Byeong-Kee;Kim, Giyoung;Kim, Suk
    • Journal of Biosystems Engineering
    • /
    • v.38 no.2
    • /
    • pp.121-128
    • /
    • 2013
  • Purpose: Porcine proliferative enteropathy (PPE), caused by the obligate intracellular bacterium Lawsonia intracellularis, is a widely distributed disease throughout the world causing substantial economic loss. In order to diagnose PPE rapidly, the rapid kit was developed and tested. Methods: In this study, a rapid kit was developed to screen the PPE rapidly at the pig farm. Also, occult blood test with fecal occult blood (FOB) kit was done for detecting the blood in pig feces which might be the evident of hemorrhagic PPE. For developing the kit, we tested fecal samples of PPE infected pigs diagnosed by polymerase chain reaction (PCR) method. Results: With the developed rapid kit, Lawsonia intracellularis was detected in high density emulsion of ileum. On the other hand, the test result of detecting Lawsonia in feces showed too high non-specific response. In addition, nevertheless the FOB test result showed that blood evident could be founded in pig feces, the diagnosing result was not fit to PCR test result, which shows blood in pig feces could be from not only hemorrhagic PPE but also many reasons. Conclusions: To deal with the PPE effectively, it will be better for farmers to screen the PPE in earlier stage with easy and rapid diagnosing tool on farm. This study found out that the rapid kit could detect the Lawsonia intracellularis and hemoglobin in pig feces. However, the non-specific response to negative samples of PPE was too high to use at a pig farm. Further research is needed for lowering the non-specific response with the rapid kit.

Development of a ladder-shape melting temperature isothermal amplification (LMTIA) assay for detection of African swine fever virus (ASFV)

  • Wang, Yongzhen;Wang, Borui;Xu, Dandan;Zhang, Meng;Zhang, Xiaohua;Wang, Deguo
    • Journal of Veterinary Science
    • /
    • v.23 no.4
    • /
    • pp.51.1-51.10
    • /
    • 2022
  • Background: Due to the unavailability of an effective vaccine or antiviral drug against the African swine fever virus (ASFV), rapid diagnosis methods are needed to prevent highly contagious African swine fever. Objectives: The objective of this study was to establish the ladder-shape melting temperature isothermal amplification (LMTIA) assay for the detection of ASFV. Methods: LMTIA primers were designed with the p72 gene of ASFV as the target, and plasmid pUC57 was used to clone the gene. The LMTIA reaction system was optimized with the plasmid as the positive control, and the performance of the LMTIA assay was compared with that of the commercial real-time polymerase chain reaction (PCR) kit in terms of sensitivity and detection rate using 200 serum samples. Results: Our results showed that the LMTIA assay could detect the 104 dilution of DNA extracted from the positive reference serum sample, which was the same as that of the commercial real-time PCR kit. The coincidence rate between the two assays was 100%. Conclusions: The LMTIA assay had high sensitivity, good detection, and simple operation. Thus, it is suitable for facilitating preliminary and cost-effective surveillance for the prevention and control of ASFV.

Evaluation of the Efficiency of E. coli O157: H7 Rapid Detection Kit using Immunochromatography (면역크로마토그래피를 이용한 E. coli O157: H7 신속검출 키트의 유효성 평가)

  • Kwak, Hyo-Sun;Lee, Dong-Ha;Moon, Hee-Sook;Park, Jong-Seok;Woo, Gun-Jo;Kim, Chang-Min
    • Journal of Food Hygiene and Safety
    • /
    • v.18 no.3
    • /
    • pp.118-124
    • /
    • 2003
  • For the rapid detection of various pathogenic microorganisms from food sample, various kinds of kits have been developed and commercially available in the markets. With the advantages of speed, accuracy and easiness, the market of these kits has gradually increased for the QC and QA field of food company as well as testing facilities or laboratories. In this study, the characteristics such as the detection limit and the sensitivity of immunochromatographic type of rapid detection kit (Donga Co, Korea, D-kit) for E. coli 0157:H7 developed by monoclonal antibody were examined and also the possibility of application of the kit to food samples was evaluated. The reference kits used for comparison study were Reveal E. coli 0157:H7 (Neogen Co., USA, R-kit) and VIP EHEC kit (Biocontrol Inc., USA, V-kit) occupying major market share. In the detection limit test with the E. coli 0157:H7 reference, both R-kit and D-kit showed a distinct positive reaction in $10^4$/ml and weak positive reaction in $10^3$/ml, whereas V-kit showed a same reaction in 105/ml. Also, it was identified that the culture treated with heat showed more sensitivity than no heat treated culture. The sensitivity test was conducted against 22 isolates of E. coli 0157:H7, 7 strains of non-O157:H7 verotoxin-producing E. coli, 40 strains of E. coli with different O and H antigen type, and 38 strains of non-E. coli Enterobacteriaceae, and all of the test strains except three were showed exactly three were showed exactly the same reaction against three kinds of the tested kits. All the three kinds of kits showed a positive reaction against E. coli O157:H19, E. coli O148:H18 and Salmonella galinarium. We suppose that there might be a similarity in serological property between these three strains and O157:H7. From the test results, it can be concluded that there is (was) no difference between the D-kit developed in this study and R-kit or V-kit based on the detection limit and sensitivity.